JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013102900010Floor Panel · delaminatedDURING C2 CHECK, FOUND DELAMINATION ON FLOOR PANEL 2221AF BETWEEN FRAMES 16 TO 20, -Z500 & BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR USAA2013102900009Floor Panel · delaminatedDURING C2 CHECK, FOUND DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 20 TO 24, -Z500 & BETWEEN Y0 TO -Y254. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR USAA2013103000001Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAMES 16 TO 20 & BETWEEN S23L & 23R. REPLACED FLOOR PANEL IAW AMM 53-12-12.SDR DALA13056220873Floor Panel · damagedFLOOR HAS SOFT SPOT IN FIRST CLASS AT ROW 4 BETWEEN B & C. REMOVED FLOOR PANEL AND FOUND HAT CHANNEL DAMAGE. REMOVED TWO DAMAGED CHANNELS IAW SRM 51-30-02. FABRICATED & DRILLED NEW CHANNELS IAW SRM 51-10. PAINTED AND SECURED NEW CHANNELS TO FLOOR PANEL IASDR ASOA2013111909418Floor Panel · corrodedRT PRESSURE FLOOR PANEL JUST FORWARD OF BS 559 HAS CORROSION AROUND NUTPLATE HOLE. REMOVED CORROSION IAW REO 601R-53-41-666 & SRM 51-21-06. COMPLIED WITH EC/TC REO 601R-53-41-666 AND REO 601R-53-41-666 REV C.SDR DALA13058285639Floor Panel · corrodedAFT CABIN DECK PLATE CORRODED IN MULTIPLE AREAS BS 1681-1720 BL 0- RBL 52. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-51. DECK PLATE REPLACED .SDR DALA13056083142Floor Panel · corrodedAFT UTILITY AREA FLOOR PANEL 261FF CORRODED. INSTALLED NEW FLOOR PANEL.SDR DALA13056113142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241MF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056103142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102.SDR DALA13056073142Floor Panel · corrodedMAIN CABIN FLOOR PANEL 231CF HAS CORRODED INSERTS. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056053142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221DF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056043142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222EF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056033142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221EF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW 3SRM 53-02-00, FIG 209.SDR DALA13056023142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231XG UPPER SURFACE DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056013142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232YG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13056003142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232FF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055993142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231LF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055983142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232YG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055973142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241KF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055963142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241CF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055953142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241JF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG.102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055943142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241HF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055933142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241AF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055923142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 242KF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055913142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 252GF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055903142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251JF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055893142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 252MF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055883142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251LF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG.102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055873141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251UF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055863142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251TF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055853142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013102500013Floor Panel · debondedDISBONDED CABIN FLOOR PANEL UPPER SURFACE BETWEEN FR35 TO FR36 & BETWEEN Y254 TO -Y254. REPLACED CABIN FLOOR PANEL UPPER SURFACE BETWEEN FR35 TO FR36 & BETWEEN Y254 TO -Y254 IAW AMM 53-32-12-040.SDR USAA2013102500012Floor Panel · separatedPILOT REPORTED SEPARATION AT FWD EDGES OF FWD CARGO FLOOR PANEL AT FR31 BETWEEN Y250 TO -Y250. REPLACED FORWARD EDGES OF FWD CARGO FLOOR PANEL IAW AMM 53-22-14.SDR DALA13055053142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251WF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055043142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241BF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055033142Floor Panel · damagedAFT UTILITY FLOOR PANEL 261PF DELAMINATED AND HAS SEVERAL PUNCTURES. FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13055023142Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261HG DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13054913276Floor Panel · corrodedDURING INSPECTION, FOUND CORROSION ON CABIN FLOOR PANEL 261FF. REPLACED FLOOR PANEL.SDR DALA13058275639Floor Panel · corrodedAFT CABIN LT GALLEY DECK PANEL HAS MULTIPLE CORROSION FROM BS 1681-1720, BL 0- LBL 52. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, PG 102-104. REMOVED, FABRICATED. LOCATED AND DRILLED AFT CABIN DECK PLATE IAW DWG 146N5300 AND SRM 51-40-05.SDR DALA13058265639Floor Panel · corrodedAFT CABIN LT GALLEY DECK PANEL HAS MULTIPLE AREAS OF CORROSION FROM BS 1768--1720 BL 0- LBL 52. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51. LOCATED AND DRILLED AFT CABIN DECK PLATE FROM BS 1681 TO 1720.SDR ASAA2013102196295Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120DF CORRODED. REMOVED FLOOR PANEL IAW AMM 25-52-10. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED NEW FLOOR PANEL IAW DWG 453A1610, REV F, INSTALLED NEW FLOOR PANEL IAW AMM 25-52-10-400-801.SDR SWAA2013102821534Floor Panel · delaminatedCABIN FLOOR PANEL 231KF DELAMINATED OF THE UPPER SURFACE AT THE FORWARD LT CORNER. R & R PANEL IAW DRAWING & SRM.SDR IPXA2013102500686Floor Panel · damagedINSPECTION C08, MAIN DECK CARGO FLOOR PANEL 252BFF DAMAGED AT BS 1109 - 1197+22, RBL 33- 54.75 FABRICATED FLOOR PANEL IAW B767-5320-9693-H.SDR DALA13054713276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 151MF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054703276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 152MF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054693276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 151CF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054683276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 151AF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054673276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 161BF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054663276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 151FF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.SDR DALA13054653276Floor Panel · damagedDURING INSPECTION, FOUND PERFORATION ON FLOOR PANEL 151BF IN AFT CARGO BAY. REPAIRED FLOOR PANEL IAW SRM 53-02-00, PAR 8C.
Back to JASC 5321