JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13043943140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 161PF HAS PREVIOUS REPAIR, MULTIPLE DENTS & EDGE CRACKED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043933140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 161NF HAS THREE PREVIOUS REPAIR, MULTIPLE DENTS, PUNCTURED & EDGE CRACKED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043923140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152WG HAS MULTIPLE DENTS, CRACKED & DEBONDED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043913140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151TG HAS MULTIPLE DENTS. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043903140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 162FF HAS PREVIOUS REPAIR & DENTS. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043893140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151HE HAS MULTIPLE DENTS. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043883140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161EF HAS MULTIPLE DENTS & CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043873140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161CF HAS 2EA PREVIOUS REPAIRS & MULTIPLE DENTS. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043863140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161BF HAS 4EA PREVIOUS REPAIRS, MULTIPLE DENTS & CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043853140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 162CF HAS DENTS, CRACKED & DISBONDED ON THE EDGE OF THE PANEL. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043843140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151BE HAS MULTIPLE DENTS, PREVIOUS REPAIRS & DISBONDED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR IPXA3680210Floor Panel · damagedPOS NR 6, AFT RT BL-4 MCD FLOOR PANEL DAMAGED.SDR IPXA3680175Floor Panel · damagedFLOOR PANEL NR 5 IS DAMAGED. FABRICATED FLOOR PANEL IAW EO B767-5320-9693-H.SDR UHLA2013090700433Doubler · corrodedLEVEL 2 CORROSION ON LT FWD DOUBLER FRAME 13-16. R & R FLOOR DOUBLER.SDR IPXA3580329Floor Panel · damagedINSPECTION C10, MAIN CABIN FLOOR PANEL 242XCF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR SWAA2013092320334Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL NR 140BF CORRODED. R & R PANEL IAW SRM.SDR SWAA2013092320333Floor Panel · corrodedAFT CARGO BAY FLOOR PANEL NR 140AF CORRODED ALONG UPPER EDGES. R & R PANEL IAW MM & SRM.SDR USAA2013091700005Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 251UF BETWEEN FRAMES 58 TO 62 & BETWEEN Y1732 TO Y1292. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209, & IRM 9701, REV G.SDR IPXA3580228Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XJF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580226Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XFF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3580225Floor Panel · damagedC-10 INSPECTION, MAIN CABIN FLOOR PANEL 241XDF DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR SWAA2013091320124Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL NR 120CF CORRODED ALONG UPPER EDGES. R&R PANEL IAW SRM.SDR DALA13043953140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152TG HAS MULTIPLE DENTS & CRACKED.SDR DALA13043833140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151UG HAS MULTIPLE DENTS. DAMAGES EXCEEDED THE ALLOWABLE LIMITS IAW SRM 53-02-00. FABRICATED NEW SLOPE PANEL 151UG IAW SRM 53-02-00 FIG 209 & DWG 3D25-40532.SDR DALA13043823140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151AE HAS MULTIPLE DENTS WITH CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043813140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152XG HAS MULTIPLE DENTS, PUNCTURED & CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043803140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151DE HAS MULTIPLE DENTS & CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00 FIG 209 & DWG 3D25-40532.SDR DALA13043793140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152TG HAS MULTIPLE DENTS & CRACKED. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00 FIG 209 & DWG 3D25-40532.SDR DALA13043783140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 161DF HAS EDGE CRACK & DEBONDED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR IPXA3680181Floorboard · dentedTWO DENTS IN FLOORBOARD 5.5 INCHES FROM RT EDGE. 46 INCHES FROM FWD/EDGE. REPAIR FLOORBOARD IAW SRM 53-00-50-2R.SDR IPXA3680171Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR DALA13043603140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161FF HAS PREVIOUS REPAIR & DENTED. SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13043593140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151FE HAS MULTIPLE DENTS & CRACKED. SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13043583140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152UG HAS MULTIPLE DENTS & CRACKED. SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13043573140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151GE HAS CRACK AND DEBONDED. SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13043563140Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 162EF HAS 3 EA DENTS & DEBONDED. SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13043553140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151ZG HAS MULTIPLE DENTS, PUNCTURED, CRACKED & DEBONDED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043543140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151CE HAS MULTIPLE DENTS AND EDGE CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043533140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151PE HAS MULTIPLE DENTS AND EDGE CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043523140Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151VG HAS THREE PREVIOUS REPAIRS, MULTIPLE DENTS & DEBONDED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13043513140Floor Panel · damagedFWD CARGO BAY FLOOR PANEL 131AF HAS MULTIPLE DENTS, SIX PUNCTURES & ONE CRACK. FOUND OUT OF LIMITS IAW SRM 53-02-00, TABLE 105. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13043503140Floor Panel · dentedFWD CARGO BAY SLOPE PANEL 131CF HAS MULTIPLE DENTS, CRACKED & DELAMINATED. FOUND OUT OF LIMITS IAW SRM 53-02 -00. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13043493140Floor Panel · dentedFWD CARGO BAY SLOPE PANEL 132EG HAS MULTIPLE DENTS AND DEBONDED. FOUND OUT OF LIMITS IAW SRM 53-02-00. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13043483140Floor Panel · dentedFWD CARGO BAY SLOPE PANEL 131DG HAS MULTIPLE DENTS, TWO PLACES OF CRACKED & DEBONDED. FOUND OUT OF LIMITS IAW SRM 53-02-00. FABRICATED NEW SLOPE PANEL 131DG IAW SRM 53-02-00, FIG 209.SDR DALA13043363140Floor Panel · debondedFWD CARGO BAY SLOPE PANEL 131EG HAS MULTIPLE DENTS AND DEBONDED. FOUND OUT OF LIMITS IAW SRM 53-02-00. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00 FIG 209.SDR AALA20130906009Floor Panel · corrodedCORRODED FLOOR PANEL AT STATION 481. REPLACED PANEL.SDR ASOA2013092709108Floor Panel · crackedRT FWD ELECTRIC BAY FLOOR IS CRACKED BY ADG STOW PUMP. REPAIRED IAW GREO 670-53-11-509. REPAIR CLASSIFIED AS MAJOR.SDR FDEA201309052132Deck Plate · corrodedBS 1681 -1720 WL 208, BL 0- LBL 57 UPPER DECK CORRODED SEVERAL AREAS. FOUND OUT OF LIMITS PER SRM 53-00-51 PG 104 FIG 101 DET III, REMOVED AND REPLACED DECK PLATE PER SRM 51-40-02 AND DWG 146N5318. MAJOR REPAIR.SDR USAA2013090900016Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 251PF BETWEEN FR54 TO FR58 & Y1292 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & IRM 9701, REV G.SDR SWAA2013102821447Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222APF DELAMINATED. R & R PANEL IAW SRM.
Back to JASC 5321