JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3579875Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XAF IS DAMAGED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3579874Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 221XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13579787Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 211XAF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO, B757-5320-9692-HSDR IPXA3579761Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XMF IS DAMAGED. FABRICATE NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579760Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XTF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579759Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XNF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579758Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XPF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579757Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XQF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579755Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XLF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579752Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XBF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579751Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251-XFF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579750Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 251XEF IS DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579749Floorboard · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 252XFF DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR CALA2013080990303Floor Panel · damagedAISLE FLOOR FROM ROW 4 THRU 6 IS SOFT AND SPONGY.SDR IPXA13579784Floor Panel · corrodedINSPECTION TYPE:C8, MAIN CABIN, UNDER FLOOR PANEL, AFT DECK PLATE HAS CORROSION BS 1680, RBL5. REPAIRED AFT DECK PLATE IAW SRM 53-60-51-2R-8.SDR IPXA13579783Deck Plate · corrodedINSPECTION TYPE: C8, MAIN CABIN PRESSURE DECK PLATE IS CORRODED AT NUTPLATE HOLES AT BS 1681, RBL 31-39. REMOVED CORROSION AND CHECKED LIMITS IAW SRM 53-60-51-1A-1, FOUND TO BE WITHIN LIMITS APPLIED PROTECTIVE TREATMENT IAW SRM 51-20-01.SDR IPXA13179792Floor Panel · puncturedINSPECTION TYPE:3C, MAIN DECK CARGO FLOOR PANEL 232RH HAS HOLE THRU IT. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3579734Floor Panel · damagedINSPECTION TYPE:C10, MAIN CABIN FLOOR PANEL 241XGF IS DAMAGED ON EDGES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR DALA13038803137Floor Panel · damagedAFT CARGO FLOOR PANEL 162EF HAS MULTIPLE DENTS & SCRATCHES. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038793137Floor Panel · damagedAFT CARGO FLOOR PANEL 151DE HAS MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038783137Floor Panel · damagedAFT CARGO FLOOR PANEL 162BF HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00 FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038773137Floor Panel · damagedAFT CARGO FLOOR PANEL 151FE HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038763137Floor Panel · damagedAFT CARGO FLOOR PANEL 151TG HAS MULTIPLE DENTS & PUNCTURED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038753137Floor Panel · crackedAFT CARGO FLOOR PANEL 162CF CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038743137Floor Panel · crackedAFT CARGO FLOOR PANEL 161BF CRACKED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209, DWG 3D25-40532 AND INSTALLED.SDR DALA13038733137Floor Panel · damagedAFT CARGO FLOOR PANEL 152TG DAMAGED. FABRICATED IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532 AND INSTALLED.SDR DALA13038723137Floor Panel · dentedAFT CARGO FLOOR PANEL 162FF HAS MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038713137Floor Panel · dentedAFT CARGO FLOOR PANEL 151AE HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038703137Floor Panel · dentedAFT CARGO FLOOR PANEL 161CF HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532. INSTALLED.SDR DALA13038693137Floor Panel · dentedAFT CARGO FLOOR PANEL 152UG HAS PREVIOUS REPAIR & MULTIPLE DENTS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25 40532. INSTALLED.SDR DALA13038683137Floor Panel · damagedAFT CARGO FLOOR PANEL 161EF HAS PREVIOUS REPAIRS & MULTIPLE DENTS. FLOOR PANEL FABRICATED SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038673137Floor Panel · damagedAFT CARGO FLOOR PANEL 161FF HAS PREVIOUS REPAIR & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038663137Floor Panel · damagedFWD CARGO FLOOR PANEL 131CF HAS PREVIOUS REPAIR & MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038653137Floor Panel · damagedFWD CARGO FLOOR PANEL 131BF HAS 3EA PREVIOUS REPAIR & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038643137Floor Panel · dentedAFT CARGO FLOOR PANEL 151BE HAS PREVIOUS REPAIRS, MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038633137Floor Panel · dentedAFT CARGO FLOOR PANEL 151VG HAS PREVIOUS REPAIRS & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038623137Floor Panel · damagedAFT CARGO FLOOR PANEL 151GE HAS MULTIPLE DENTS & PUNCTURED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038613137Floor Panel · damagedAFT CARGO FLOOR PANEL 151HE HAS PREVIOUS REPAIR & DAMAGED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR FDEA201308061795Floor Panel · delaminatedMAIN CARGO FLOOR PANEL 282AF FOUND DELAMINATED. FLOOR PANEL REMOVED IAW AMM 53-21-04, REV 76.1. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J AND SRM 51-90-01, REV 53, AND INSTALLED IAW AMM 53-21-04, REV 76.1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-1SDR CALA2013080890276Floor Panel · damagedSOFT SPOT IN FLOOR UNDER F/A JUMP SEAT AT L2 DOOR. INSTALLED INTERIM REPAIR IAW SRM.SDR IPXA13579684Floor Panel · damagedINSPECTION TYPE: C1S3, MAIN DECK FLOOR PANEL 221XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13B79663Floorboard · damagedFLOORBOARD AT BS 1930 LT NR 5 DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B747-5320-51139-A.SDR DALA13038183137Floor Panel · corrodedAFT CARGO FLOOR PANEL 152YG, HAS SIX FASTENER HOLES & TWELVE FASTENERS CORRODED. REPLACED FLOOR PANEL SCREWS.SDR IPXA13B79639Floor Panel · damagedMAIN CARGO FLOOR PANEL DAMAGED BS 1927 AND 1934. REPAIR IAW EO B747-53-20-51136-A.SDR IPXA13B79662Floorboard · puncturedFLOORBOARD AT BS 1920, PUNCTURED. FABRICATED NEW FLOORBOARD IAW EO B747-5320-511364.SDR IPXA13B79655Floorboard · puncturedFLOOR PANEL AT BS 1930 HAS PUNCTURE. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51139-A.SDR IPXA13B79653Floor Panel · puncturedMAIN CARGO DECK FLOOR PANEL HAS ONE HOLE LBL 33.5 FWD EDGE OF OTBD EDGE. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51567-A.SDR DALA13038173137Floor Panel · damagedFWD CARGO FLOOR PANEL 132DG HAS THREE PREVIOUS REPAIRS & MULTIPLE DENTS. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038163137Floor Panel · damagedFWD CARGO FLOOR PANEL 131CG HAS MULTIPLE DENTS & CRACKED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13038153137Floor Panel · damagedAFT CARGO FLOOR PANEL 151PE HAS MULTIPLE DENTS & PUNCTURED. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.
Back to JASC 5321