SDR USAA2013071900028Floor Panel · delaminated2S CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL NR 151LF BETWEEN FR56 TO FR58 & BETWEEN Y765 TO -Y765. REPLACED AFT CARGO FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900027Floor Panel · corroded2S CHECK - CORROSION ON AFT CARGO FLOOR PANEL NR 151PF BETWEEN FR58 TO FR59 & BETWEEN Y1292 TO -Y1292. REPLACED AFT CARGO FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR IPXA3B79304Floor Panel · puncturedFLOOR PANEL, BS 1920 PUNCTURED. REPAIRED IAW SRM 53-00-50-2R, REPAIR 1.SDR IPXA3B79303Floor Panel · puncturedFLOOR PANEL, BS 2200, POS 18R PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51432-A.SDR IPXA3B79302Floor Panel · damagedFLOOR PANEL, BS 1740-1840, LBL12-33 HAS TWO AREAS OF DAMAGE, FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51434-A.SDR IPXA3B79301Floor Panel · damagedMCD FLOOR PANEL, BS 2064 DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51435-A.SDR IPXA3B79293Floor Panel · damagedHOLE IN FLOOR PANEL BS 1786. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-51433-A.SDR USAA2013073000014Floor Panel · delaminatedDURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 231CF, FR24 TO FR28 & Y254 TO Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR ASOA2013072308746Floor Panel · crackedFS 193.00, ELECTRICAL BAY FLOOR CRACKED ON RT SIDE UNDER ADG STOW PUMP, FWD OTBD CORNER. REPAIR IS CLASSIFIED AS MAJOR. COMPLIED WITH EC/TC REO 670-53-11-509 AND GREO 670-57-11-509.SDR USAA2013071900042Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261DF BETWEEN FR66 TO FR68 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900037Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 232DF BETWEEN FR24 TO FR28 & BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900036Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 221EF BETWEEN FR20 TO FR24 & BETWEEN Y1292 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR USAA2013071900035Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222EF BETWEEN FR20 TO FR24 & BETWEEN -Y1292 TO -Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222CF BETWEEN FR20 TO FR 24 & BETWEEN -Y254 TO -Y1792. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900031Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 221LF BETWEEN FR16 TO FR20 & BETWEEN Y1292 TO Y1732. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR USAA2013071900030Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 221PF BETWEEN FR 52 TO FR 56 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL IAW SRM 53-02-00, FIG. 209.SDR IPXA3579397Floorboard · brokenINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XYF BROKEN AND INSERT PULLED OUT. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-532 0-18249-E. FABRICATED NEW FLOORBOARD IAW SR EO B757-5320-9692.SDR DALA13035309206Cusp Web · corrodedRIGHT CABIN CUSP WEB CORRODED, BS 522-532. CUTOUT CORROSION. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 51-10-03, 53-00-01, 53-20-02 AND AMM.SDR IPXA3579377Floor Panel · tornINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 232XWF EXTENSION STRIP FASTNER HOLES. FABRICATED NEW FLOOR PANEL IAW SREOB757-5320-9692H.SDR IPXA3579396Floorboard · erodedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD EDGE ERODED BS 1040, STR 24.75L. DAMAGED FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757 -5320-18249-E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3579393Floor Panel · puncturedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 222XCF CRACKED AND PUNCTURED ON LOWER SURFACE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR USAA2013071700031Floor Panel · cracked2S CHECK -CRACK ON FLOOR PANEL NR 252GG BETWEEN FR54 TO FR60, -Z500 & BETWEEN -Y1292 TO -Y1589. REPLACED FLOOR PANEL IAW IRM 9701, REV G.SDR IPXA3579375Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 232XCF DENTED AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579374Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 222XBF PUNCTURED AND DENTED LOWER SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579373Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XAF EDGE IS ERRODED. FABRICATED NEW MAIN CABIN FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA3579372Floor Panel · delaminatedINSPECTION TYPE: C-8, MAIN CABIN FLOOR PANEL 222XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579360Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XWF DAMAGED INSERT. EVALUATED FLOORBOARD DAMAGE AND FOUND TO BE BEYOND ALLOWABLE LIMITS IAW SREO B757-5320-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-19692.SDR IPXA3579359Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XTF DAMAGED INSERT. DAMAGED INSERT AND ADDITIONAL DAMAGE ON BOTTOM OF FLOORBOARD EXCEEDS ALLOWABLE LIMITS OF SREO B757-5320-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3579358Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XQF DAMAGED INSERT. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-53 20-18249-E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3579357Floorboard · damagedINSPECTION TYPE: C-8, MAIN CABIN FLOORBOARD 232XYF DAMAGED. DAMAGE TO FLOORBOARD EXCEEDS ALLOWABLE LIMITS IAW SREO B757-532 0-18249E. FABRICATED FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA3579347Floorboard · delaminatedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 241XHF HAS DAMAGED INSERT/DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA3579346Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 252XEF HAS DAMAGED INSERT/DELAMINATED. FABRICATE NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA3579345Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 231XVF HAS A DAMAGED INSERT/DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692 H.SDR IPXA3579344Floorboard · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XEF DAMAGED INSERT/DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR SWAA2013080118765Floor Panel · crackedFLOOR PANEL 222 ALF CRACKED. REPAIRED PANEL IAW SRM & MM.SDR SWAA2013080118763Floor Panel · crackedFLOOR PANEL 222 NF CRACKED. REPAIRED DOUBLER IAW SRM.SDR SWAA2013080118760Floor Panel · crackedFLOOR PANEL 222 AFF CRACKED. REPAIRED DOUBLER IAW SRM.SDR SWAA2013080118751Floor Panel · crackedFLOOR PANEL 222 ASF CRACKED. REPAIRED PANEL IAW SRM & AMM.SDR IPXA3179489Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231MJ LOWER SKIN IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR SWAA2013072518561Floor Panel · crackedFLOOR PANEL 222 AQF CRACKED. REPAIRED DOUBLER IAW SRM.SDR SWAA2013072518560Floor Panel · corrodedFLOOR PANEL 222 HF CORRODED. R&R PANEL IAW SRM.SDR SWAA2013072418504Floor Panel · crackedFLOOR PANEL 222 XF CRACKED. REPAIRED PANEL IAW SRM.SDR SWAA2013072418503Floor Panel · corrodedFLOOR PANEL 222 SF CORRODED. REPAIRED PANEL IAW SRM.SDR IPXA13179460Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 222EG HAS LOWER SKIN CRACKED FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA13179459Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231QH HAS LOWER SKIN CRACKED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PAR 6A.SDR IPXA13179414Floorboard · puncturedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 232BH LOWER SKIN IS PUNCTURED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA13179411Floorboard · tornINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231SG LOWER SKIN IS TORN. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA13179410Floorboard · puncturedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 232EF HAS LOWER SKIN PUNCTURED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3179391Floorboard · puncturedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231RJ HAS LOWER SKIN PUNCTURED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3179390Floorboard · puncturedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 232NG HAS LOWER SKIN PUNCTURED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.
Back to JASC 5321