JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13029543218Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151GF HAS SEVERAL BROKEN INSERTS & DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13029533218Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131AF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13029523218Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131HF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13029513218Floor Panel · damagedDURING INSPECTION, FOUND FORWARD CARGO FLOOR PANEL 131JF DELAMINATED AND DAMAGED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13029503218Floor Panel · damagedDURING INSPECTION, FOUND FORWARD CARGO FLOOR PANEL 132KF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR IPXA13678868Floorboard · damagedMAIN CARGO DECK FLOORBOARD 2R DAMAGED. FABRICATED NEW FLOORBOARD REF EO B767-5320-9693-H.SDR IPXA13B79231Floor Panel · delaminatedINSPECTION TYPE:D, BS 660-760, RBL 33-75 FLOOR PANEL FOUND SEVERAL PUNCTURES DENTS AND SURROUNDING EDGE DELAMINATION. FLOOR PANEL REPLACED IAW DWG 65B38454-16 AND INSTALL IAW AMM 53-21-02.SDR IPXA13B79230Floor Panel · delaminatedINSPECTION TYPE:D, BS 760-860, RBL 33 - 75, FLOOR PANEL FOUND SEVERAL PUNCTURES DENTS AND SURROUNDING EDGE DELAMINATION. FLOOR PANEL REPLACED IAW DWG 65B38459-6 AND INSTALLED IAW AMM 53-21-02.SDR IPXA3678972Floor Panel · crackedINSPECTION TYPE:C08, FOUND CRACK DAMAGE ON M/D CARGO FLOOR PANEL AT BS 750, RBL 52. DIMENSIONS OF CRACK DAMAGE: 2.75" L. REPAIR IAW EO B767-5320-9693-H.SDR DALA1315460683Deck Plate · corrodedCORROSION ON UPPER SURFACE OF DECK PLATE FROM BS 1680-1720, LBL 55, RBL 55 MAIN CABIN. REPAIRED IAW SRM 53-60-51, REPAIR 2.SDR IPXA13M79137Floor Panel · corrodedINSPECTION TYPE:2C, CORROSION ON RCB FLOOR PANEL WSP0789-501, BS 479, LBL48. R & R FLOOR PANEL IAW DWG SP11530078-7005.SDR IPXA3M79079Floor Panel · corrodedINSPECTION TYPE:4C, CORRODED FLOOR PANEL AT BS 482 AND LBL 62. R & R FLOOR PANEL IAW EO MD1 1-5330-27218-D.SDR IPXA13578922Floorboard · brokenINSPECTION TYPE:C-11, MAIN CABIN FLOORBOARD 251XNF EDGE BROKEN. FABRICATED NEW FLOORBOARD SREO B757-5320-9692-H.SDR IPXA13578914Floorboard · delaminatedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 232XPF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578883Floorboard · crackedINSPECTION TYPE:C-11, MAIN CABIN FLOORBOARD 231XMF CENTER AREA CRACKED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578879Floorboard · delaminatedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 231XHF DELAMINATED ON UPPER SURFACE SKIN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578867Floorboard · puncturedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 252XTF PUNCTURED ON THE FWD SIDE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578866Floorboard · delaminatedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 252XBF FWD EDGE IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR DALA13029003218Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261FF HAS CORROSION. REPLACED FLOOR PANEL IAW SRM 51-72-11.SDR DALA13028953216Floorboard · corrodedDURING INSPECTION, FOUND CORROSION ON OTBD UPPER FLOORBOARD SPLICE LOCATED AFT PAX CABIN AT FR.64, LEVEL Y-765, SSI 534147. L=1", W=0.5", D=0.003" APPROX. REPLACED OTBD UPPER FLOORBOARD SPLICE IAW SRM 51-72-11.SDR ASAA2013061295369Floor Panel · dentedPAX CABIN FLOOR PANEL 2378Y TOPSIDE HAS NUMEROUS DENTS AND DAMAGE TO FWD END. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50 PAR 3C, PGS 1 AND 2.SDR IPXA13M79138Floor Panel · corrodedINSPECTION TYPE:2C, RCB AREA FLOOR PANEL CORRODED AT BS 475 LBL 75. R & R RCB FLOOR PANEL IAW DWG SP11530078-7005.SDR ASAA2013061295203Floor Panel · dentedLT INBD CABIN FLOOR PANEL NR 2376 HAS SEVERAL DENTS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR IPXA3M79078Floor Panel · corrodedINSPECTION TYPE:4C, COURIER AREA MACHINED ALUMINUM FLOOR PANEL CORRODED AT GALLEY WATER HOSE CONNECTION. R & R COURIER AREA FLOOR PANEL AT GALLEY WATER HOSE CONNECTION REF EO MD11-5330-27218-D, APPX B.SDR IPXA3M79077Floor Panel · corrodedINSPECTION TYPE:4C, MACHINED ALUMINUM FLOOR PANEL CORRODED IN COURIER AREA AT BS 482 AND LBL 47. R & R COURIER FLOOR PANEL (PN WSP0788-501) AT STA 482 AND LBL47, REF MD11-5330-27218-D, APPX. B.SDR ASAA2013061295300Floor Panel · scratchedPAX CABIN FLOOR PANEL 2469Y TOPSIDE HAS SCRATCHES. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR USAA2013062400036Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 211CF BETWEEN FR6 TO FR12 & BETWEEN -Y254 TO Y254. REPLACED FLOOR PANEL 211CF IAW SRM 53-12-00 & IRM 9701, REV G.SDR ASAA2013061295202Floor Panel · dentedPAX CABIN LT INBD CABIN FLOOR PANEL 2353Y TOPSIDE FWD/AFT HAS NUMEROUS DENTS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295201Floor Panel · delaminatedPAX CABIN FLOOR PANEL 2455Y FWD END IS CRUSHED/DELAMINATION. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50 PAR 3C, PGS 1 AND 2.SDR ASAA2013061295200Floor Panel · dentedPAX CABIN FLOOR PANEL 2466Y TOPSIDE/BOTTOM SIDE HAS NUMEROUS DENTS AND CRUSHED HONEYCOMB ON EDGES. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50 PAR 3C, PGS 1 AND 2.SDR ASAA2013061295199Floor Panel · gougedPAX CABIN RT INBD FLOOR PANEL 2348Y AFT END TOPSIDE HAS CRUSHED HONEYCOMB AND DEEP GOUGES. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295198Floorboard · damagedCABIN FLOORBOARD 2346Y HAS EDGE DAMAGE ON 1 SIDE, TRANS FROM MIG 85, ITEM NR 1 DUE TO RII. ACFT GROUNDED. REPAIRED FLOORBOARD IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295197Floor Panel · delaminatedPAX CABIN FLOOR PANEL 2469Y AFT END HAS DELAMNATION AND DAMAGE TO EDGE/CORNERS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295196Floor Panel · scratchedPAX CABIN FLOOR PANEL 2377 TOP SURFACE HAS SCRATCHES. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295195Floor Panel · dentedPAX CABIN FLOOR PANEL 2444Y TOPSIDE HAS NUMEROUS DENTS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295194Floor Panel · dentedPAX CABIN RT OTBD CABIN FLOOR PANEL NR 2359Y TOPSIDE FWD AFT HAS NUMEROUS DENTS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295193Floor Panel · dentedPAX CABIN FLOOR PANEL 2450Y BOTTOM SIDE HAS NUMEROUS DENTS. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50 PAR 3C, PGS 1 AND 2.SDR ASAA2013061295192Floor Panel · dentedPAX CABIN FLOOR PANEL NR 2373Y TOPSIDE HAS NUMEROUS DENTS AND CRUSHED/MISSING HONEYCOMB CORE. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR ASAA2013061295190Floor Panel · damagedPAX CABIN FLOOR PANEL, 2435Y FWD END HAS DAMAGED, CRUSHED HONEYCOMB CORE. ACFT GROUNDED. REPAIRED FLOOR PANEL IAW SRM 53-00-50, PAR 3C, PGS 1 AND 2.SDR SWAA2013061817226Floor Panel · brokenFLOOR BOARD PANEL 221BF AFT OUTBOARD EDGED BROKEN. REPAIRED PANEL IAW SRM.SDR USAA2013061700034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 251XF UPPER SURFACE BETWEEN FR62 TO FR64, S23L, Z-500 & Y1028. REPLACED FLOOR PANEL NR 251XF IAW IRM 9701, REV G.SDR IPXA13578880Floorboard · puncturedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 222XBF PUNCTURED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578878Floorboard · puncturedINSPECTION TYPE:C-11, MAIN CABIN FLOORBOARD 231XAF PUNCTURED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR DALA13029053218Floor Panel · delaminatedDURING INSPECTION, FOUND MID CABIN FLOOR PANEL 252FF DELAMINATED 1" X 24". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13029043218Floorboard · brokenDURING INSPECTION, FOUND FWD UTILITY FLOORBOARD 221DF SEVERAL INSERTS BROKEN & MISSING. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13029033218Floor Panel · puncturedDURING INSPECTION, FOUND FWD UTILITY FLOOR PANEL 222CF PUNCTURED 1" X 1". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13028983218Floor Panel · damagedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261PF SEVERAL INSERTS MISSING & BROKEN. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13028973218Floorboard · damagedDURING INSPECTION, FOUND MAIN CABIN FLOORBOARD 251MF IS DAMAGED, L=84, W=20. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13028963218Floorboard · damagedDURIING INSPECTION, FOUND MAIN CABIN FLOORBOARD 251JF IS DAMAGED, W=18 L=63. FLOORBOARD FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.SDR DALA13028943218Floor Panel · delaminatedDURING INSPECTION, FOUND MID CABIN FLOOR PANEL 251YF DELAMINATED 1" X 24". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-37498.
Back to JASC 5321