JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2013052595361Floor Panel · damagedCABIN FLOOR PANEL UNDER FWD LAV HAS DAMAGED AREA. ACFT GROUNDED. BONDED FLOOR PANEL IAW IAW SRM 53-00-50, PAR 30, PGS 1 & 2.SDR AALA20130621023Floorboard · corrodedAFT CARGO CORROSION AROUND FASTENER HOLES IN TOP OF FLOORBOARD FROM STATIONS 770-887. INSTALLED NEW FLOORBOARD IAW AARD 51-10-5.SDR AALA20130621022Floorboard · corrodedAFT CARGO CORROSION AROUND FASTENER HOLES IN TOP OF FLOORBOARD FROM STATIONS 767-770. INSTALLED NEW FLOORBOARD IAW AARD 51-10-5.SDR FDEA201305251087Floor Panel · delaminatedAIR CONDITIONING COMPARTMENT FWD LT FLOOR PANEL FOUND DELAMINATED. REMOVED FLOOR PANEL AND INSTALLED IAW AMM 20-21-12, REV 55.2 , NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005 REVISION J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 116 .SDR IPXA13578618Floor Panel · puncturedINSPECTION TYPE:S3C7, FLOOR PANEL 211AXF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW EO B757-9320 -9692H.SDR IPXA13578616Floor Panel · puncturedINSPECTION TYPE:S3C7, MAIN DECK FLOOR PANEL 252XUF HAS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-932 0-9692-H.SDR USAA2013052800036Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261DF BETWEEN FR66 TO FR68 & BETWEEN -Y765 TO Y765. REPLACED FLOOR PANEL 261DF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800035Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 262EF BETWEEN FR66 TO FR68 & BETWEEN Y1292 TO Y1732. REPLACED FLOOR PANEL 262EF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800026Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 232DF BETWEEN FR20 TO FR24 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 232DF IAW SRM 53-02-00, FIG. 209.SDR DALA13025823136Floor Panel · corrodedFWD CABIN FLOOR PANEL 221FF CORRODED. REPLACED FLOOR PANEL.SDR UALA2013052403613Floor Panel · delaminatedFLOOR SPONGEY AND CLICKS LOUDLY IN AISLE FLOOR BY 7C-B AND 8C-B MADE INTERIM REPAIR IAW MM 53-21-99, .3" X 2" DELAMINATION IN FLOOR PANEL AT 7CB. REPAIR AT NEXT C CHECK.SDR IPXA3178793Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 251BN LOWER SKIN IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR FDEA201305231076Longeron · corrodedCENTER CARGO, BS 5-123 TO 1541, LONGERON 48R FOUND CORRODED. REPAIRED IAW SRM 51-21-01 REVISION 52 , MATERIAL REMOVED 0.006 INCH, MATERIAL REMAINED 0.064 INCH , ORIGINAL THICKNESS 0.070 INCH AND FOUND WITHIN LIMIT AS PER SRM 53-00-00 FIGURE 202 REVISION 5SDR SWAA2013060616865Floor Panel · corrodedFLOOR PANEL EDGE CORRODED. R & R PANEL IAW SRM.SDR IPXA13178662Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 252AN LOWER SKIN IS DELAMINATED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR SWAA2013060416745Floor Panel · corrodedFLOOR PANEL EDGE CORRODED BETWEEN STA 756 TO STA 794, LBL 44. REPAIRED PANEL IAW SRM.SDR IPXA13178635Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 252EN LOWER SKIN IS TORN AND DELAMINATED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA13178632Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 252CH LOWER SKIN IS DELAMINATED. REPAIRED MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR USAA2013052800037Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261PF BETWEEN FR66 TO FR70 & BETWEEN Y1292 TO Y1292. REPLACED FLOOR PANEL 261PF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800034Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261EF BETWEEN FR66 TO FR68 & BETWEEN Y1232 TO Y1732. REPLACED FLOOR PANEL 261EF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800033Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261HG BETWEEN FR64 TO FR66 & BETWEEN Y765 TO Y1732. REPLACED FLOOR PANEL 261HG IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800032Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 251RF BETWEEN FR57 TO FR62 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 251RF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800031Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL, 251LF BETWEEN FR54 TO FR58 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 251LF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800030Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 241LF BETWEEN FR42 TO FR47 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL 241LF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800028Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232RF BETWEEN FR28 TO FR32 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 232RF IAW SRM 53-02-00, FIG. 209.SDR USAA2013052800027Floor Panel · delaminated2S CHECK, DELAMINATION ON FLOOR PANEL 231KF BETWEEN FR24 TO FR28 & BETWEEN Y254 TO Y254. REPLACED FLOOR PANEL 231KF IAW A321, SRM 53-02-00, FIG. 209.SDR USAA2013052800025Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 231FF BETWEEN FR20 TO FR24 & BETWEEN Y1232 TO Y1732. REPLACED FLOOR PANEL NR 231FF IAW SRM 53-02-00, FIG. 209.SDR DALA13025743136Floor Panel · corrodedFWD CABIN FLOOR PANEL 222FF HAS CORROSION AND DELAMINATED, REPLACED FLOOR PANEL AND INSTALLED.SDR DALA13025703136Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241EF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025693136Floor Panel · crackedCENTER CABIN FLOOR PANEL 242LF CRACKED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025683136Floor Panel · damagedAFT CABIN UTILITY FLOOR PANEL 261BG HAS DAMAGE INSERT HOLE AND DEFORMED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025673136Floor Panel · delaminatedFWD CABIN FLOOR PANEL 232LF IS DELAMINATED DIM. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025663136Floor Panel · damagedFWD CABIN UTILITY FLOOR PANEL 221EF BOTTOM SURFACE HAS DAMAGED HONEYCOMB. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025653136Floor Panel · corrodedAFT CABIN UTILITY FLOOR PANEL 261PF HAS 4 EA CORRODED INSERTS AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025643136Floor Panel · debondedAFT CABIN UTILITY FLOOR PANEL 262BG DEBONDED AROUND INSERT HOLE. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025633136Floor Panel · damagedCENTER CABIN FLOOR PANEL 251FF CORNER EDGE HONEYCOMB DAMAGED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025623136Floor Panel · dentedFWD CARGO BAY FLOOR PANEL 131DG HAS MULTIPLE DENTS, CRACKS AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40632.SDR DALA13025073136Floor Panel · delaminatedAFT CABIN FLOOR PANEL 251LF IS DELAMINATED, DIM. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025063136Floor Panel · damagedFWD CARGO FLOOR PANEL 131EG HAS MULTIPLE DENTS, CRACKS AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40632.SDR DALA13025053136Floor Panel · damagedFWD CARGO FLOOR PANEL 132EG HAS MULTIPLE DENTS, DEEP SCRATCHES & DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40632.SDR DALA13025043136Floor Panel · damagedFWD CARGO FLOOR PANEL 132DG HAS MULTIPLE DENTS AND DELAMINATED. L=1.50" X W=1.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40632.SDR DALA13025033136Floor Panel · damagedFWD CARGO FLOOR PANEL 131BF HAS MULTIPLE DENTS & CRACKS. L=2.5" X W=0.75". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40632.SDR DALA13025023136Floor Panel · damagedFWD CARGO COMPT FLOOR PANEL 131CG HAS MULTIPLE DENTS AND CRACKS. L=2.0" W=0.50". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13025013136Floor Panel · damagedAFT CABIN FLOOR PANEL 262EF HAS DAMAGED HOLE AND DELAMINATED 6" X 2". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13025003136Floor Panel · delaminatedAFT CABIN FLOOR PANEL 261EF DELAMINATED 8" X 6". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13024993136Floor Panel · delaminatedAFT CABIN FLOOR PANEL 261DF DELAMINATED 10" X 4". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR IPXA3178826Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 262DM UPPER SKIN IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR SWAA2013061017054Floor Panel · corrodedFLOOR PANEL CORRODED BETWEEN STA 370 TO STA 389, RBL 44. R & R PANEL IAW SRM.SDR SWAA2013060516795Floor Panel · corrodedFLOOR PANEL CORRODED BETWEEN STA 389 TO STA 465, RBL 44. R & R PANEL IAW SRM.SDR SWAA2013060416765Floor Panel · corrodedFLOOR PANEL CORRODED BETWEEN STA 541 TO STA 636, RBL 44. REPAIRED PANEL IAW SRM.
Back to JASC 5321