JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA12175861Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242TN IS CRACKED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12575814Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XLF INSERTS PULLED THROUGH. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575813Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XKF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575805Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 251XBF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12176045Floorboard · damagedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 251LG HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12176018Floorboard · damagedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 261GH HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175990Floorboard · damagedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 261SF HAS DAMAGED EDGE SEALING. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175952Floor Panel · crackedINSPECTION TYPE: 10YR, FLOOR PANEL 262FM CRACKED. REPAIRED IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175951Floor Panel · crackedINSPECTION TYPE: 10YR, MAIN DECK CARGO FLOOR PANEL 261FM CRACKED. REPAIRED IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175949Floor Panel · crackedINSPECTION TYPE:10YR, MAIN DECK CARGO FLOOR PANEL 261AM CRACKED. REPAIRED IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175930Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252YM IS CRACKED AT UPPER CORNER. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175927Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252ZJ IS DELAMINATED AT LOWER SKIN. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175900Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242UM IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175897Floorboard · puncturedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242VM IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175896Floorboard · puncturedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252GF IS PUNCTURED AT LOWER SURFACE. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175893Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252LG IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR IAW EO A300-5320-42721-B, PARA 6A.SDR USAA2012101500016Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151ZG BETWEEN FR56 TO FR59 & BETWEEN S38L TO S38R. REPLACED FLOOR PANEL 151ZG IAW A319 SRM 53-02-00 & IRM 9701 REV G.SDR IPXA12175869Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 251GJ IS DELAMINATED AT LOWER SKIN. ACCOMPLISHED REPAIR ON FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12575823Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XUF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12575822Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XRF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12575812Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XAF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575803Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XSF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12575802Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XHF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12575799Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XJF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12575784Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XNF HAS DELAMINATED CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575781Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XPF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575780Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XTF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575779Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XMF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575778Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XGF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575777Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XCF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575774Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XGF DELAMINATED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR DALA12009943271Floor Panel · corrodedDURING INSPECTION, FOUND MAIN CABIN R1 DOOR ENTRY FLOOR PANEL 222FF CORRODED AROUND BOTTOM EDGES. REPLACED FLOOR PANEL IAW SRM 51-72-11. DAMAGED DIMENSION L=5.0"W=2.0"D=0.030".SDR DALA12009933271Floor Panel · corrodedDURING INSPECTION, FOUND MAIN CABIN L1 DOOR ENTRY FLOOR PANEL 221FF CORRODED AROUND BOTTOM EDGES. REPLACED FLOOR PANEL IAW SRM 51-72-11. DAMAGED DIMENSION L=6.0"W=2.0"D=0.025".SDR USAA2012101100003Floor Panel · delaminatedS2 CHECK - DELAMINATION ON FLOOR PANEL 231YF BETWEEN FR32 TO FR35, S23L, Z-500, Y1497. REPLACED FLOOR PANEL 231YF IAW IRM 9701 REV G.SDR IPXA12176044Floorboard · damagedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242LJ HAS A MISSING INSERT. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12176043Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 251BN IS DELAMINATED AT UPPER AND LOWER SKIN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12176015Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 241NK IS CRACKED AT TWO PLACES ON LOWER SKIN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175992Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252FM LOWER SKIN IS DELAMINATED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175991Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252LM HAS A CRACK ON LOWER SKIN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175989Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 251XJ HAS A CRACK AT LOWER SURFACE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175988Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242NK IS CRACKED AT LOWER SURFACE FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175987Floorboard · brokenINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 231XG HAS A PIECE BROKEN OFF AND LOWER SKIN DAMAGED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175975Floorboard · damagedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242KF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175974Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 241KF IS CRACKED AT LOWER SURFACE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B APPENDIX B.SDR IPXA12175973Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 241BF LOWER SKIN IS DAMAGED IN TWO PLACES. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175972Floorboard · brokenINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242YG CORNER IS BROKEN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175971Floorboard · brokenINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 241AJ IS BROKEN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175969Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 251FJ IS CRACKED AT EDGE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175954Floor Panel · delaminatedINSPECTION TYPE: 10YR, MAIN DECK CARGO FLOOR PANEL 242PK DELAMINATED. REPAIRED IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175934Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242SK IS DELAMINATED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.
Back to JASC 5321