JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2575687Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XYF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575686Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 232XWF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR DALA12009350880Floor Panel · crackedMAIN CABIN ALUMINUM FLOOR PANEL 72A FWD EDGE BENT, BUCKLED, CRACKED BS 734. FABRICATED STIFFENER AND FLOOR PANEL 72, IAW SRM 53-23-0, FIG 5.SDR USAA2012101200020Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20 & BETWEEN -Y765 TO -Y1722. REPLACED FLOOR PANEL 222FF IAW A319 SRM 51-72-11.SDR IPXA2575751Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 232XEF MISSING INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575699Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XFF HAS DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR USAA2012100400012Screw · improper partAFTER TAKEOFF, LOST NR 1 GENERATOR WITH STRONG ODOR IN THE FLIGH DECK AND RETURNED TO SJC. ODOR ISOLATED TO FLIGHT DECK AND DISSIPATED. FOUND A FLOORBOARD SCREW OF FORWARD LAV, AFT OF WALL, OUTBOARD OF JUMPSEAT TOO LONG AND WENT THRU THE NR 1 FEEDER CABLE CASDR USAA2012100300005Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 261DF BETWEEN FR66 TO FR68 & BETWEEN -Y765 TO Y765. REPLACED FLOOR PANEL 261DF IAW A319 SRM 53-02-00.SDR USAA2012100300004Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 261BG BETWEEN FR64 TO FR66 & BETWEEN -Y765 TO Y1732. REPLACED FLOOR PANEL 261BG IAW A319 SRM 53-02-00.SDR USAA2012100300003Floor Panel · damagedC11 CHECK - ELONGATED HOLE IN FLOOR PANEL 231CF BETWEEN FR20 TO FR24 & BETWEEN -Y254 TO Y254. REPLACED FLOOR PANEL 231CF IAW A319 SRM 53-02-00.SDR IPXA12175970Floorboard · brokenINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 251DF IS BROKEN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR USAA2012101800013Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 251GF BETWEEN FR51 TO FR54 & BETWEEN Y765 TO Y254. REPLACED FLOOR PANEL 251GF IAW A319 SRM SUPPLEMENTAL INFORMATION 53-02-00-201 & IRM 9701 REV G SRM 53-12-00-201 FIG 209.SDR USAA2012101700015Floor Panel · delaminatedC11 CHECK - DELAMINATION ON AFT CARGO FLOOR PANEL 151CG AT FR58, --Y584.2. REPLACED AFT CARGO FLOOR PANEL 151CG IAW A319 SRM 53-02-00.SDR IPXA12175874Floor Panel · crackedINSPECTION TYPE:10YR, FLOOR PANEL 242TN CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12575651Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 221XCF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575650Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 221XBF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575649Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 221XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR DALA12009103134Floor Panel · damagedDAMAGE ON AFT CARGO FLOOR PANEL 151LF 6 INCHES FROM AFT EDGE & 10 INCHES FROM LEFT OTBD EDGE .500 X .700, .225 DEPTH. PERFORMED PERMANENT REPAIR IAW SRM 53-02-00.SDR USAA2012101800012Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 212EF BETWEEN FR6 TO FR12 & BETWEEN -Y765 TO -Y254. REPLACED FLOOR PANEL 212EF IAW A319 SRM SUPPLEMENTAL INFORMATION 53-02-00-201, IRM 9701 REV G & SRM 53-12-00-201 FIG 206.SDR USAA2012101500023Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 211EF BETWEEN FR6 TO FR9 & BETWEEN Y254 TO Y765. REPLACED FLOOR PANEL 211EF IAW A319 SRM SUPPLEMENTAL INFORMATION 53-02-00-201 & 53-12-00.SDR QMLA2012093012161Floor Panel · crushedTHE CABIN FLOOR HAS MULTIPLE AREAS OF DAMAGE/CRUSHED HONEYCOMB. REMOVED UPPER SKIN FROM DAMAGED AREAS. POTTED THE EXPOSED CORE AREA TO ACHIEVE A FLAT AND SMOOTH SURFACE, TO EVEN WITH THE EXISTING SKIN. FABRICATED A DOUBLER USING 0.032" THICK 2024-T3 ALUMINUM SDR IPXA12175655Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 252XJ IS CRACKED AT 2 PLACES ON LOWER SURFACE. REPAIRED FLOORBOARD IAW EO A300-5320-42721-B, APPENDIX B.SDR IPXA12675605Floor Panel · damagedSMALL HOLE IN FLOOR PANEL 4R. FABRICATED FLOOR PANEL IAW EO B767-5320-9693H AND REPLACED.SDR DALA12010085651Deck Plate · corrodedCORROSION ON MAIN CABIN DECK PLATE FROM STA 1680-1720 BL-0 TO BL-52L. REMOVED CORROSION AT 10 EA. DIFFERENT AREAS ON AFT DECK PLATE FROM STA 1680-1720 BL0 TO BL 52L, FOUND TO BE WITH IN LIMITS IAW SRM 53-60-51, PAGE 201, FIG 201, REPAIR 2. AT THE STA 1681,SDR DALA12010075651Deck Plate · corrodedCORROSION ON MAIN CABIN DECK PLATE FROM STA 1680-1720, BL-0 TO BL-52R (AREAS MARKED). REMOVED CORROSION AT 13 EA DIFFERENCE AREAS ON AFT DECK PLATE FROM STA 1680-1720, BL 0 TO BL 52R, AND FOUND TO BE WITHIN LIMITS IAW SRM 53-60-51, PAGE 201 FIG 201, REPAIR 2SDR FDEA201209293516Floor Panel · crackedFLOOR PANEL 231YG HAS A CRACK ON TOP SKIN. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA2575705Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 212XAF HAS DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575677Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO DECK FLOOR PANEL 222XAF HAS MISSING INSERT. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR USAA2012101100006Floor Panel · delaminatedS2 CHECK - DELAMINATION ON FLOOR PANEL 151ZG BETWEEN FR59 TO FR55 BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151ZG IAW A319 SRM 53-02-00-201 FIG 209 & IRM 9701 REV G.SDR IPXA12575596Floor Panel · crackedINSP TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XPF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12175590Floorboard · crackedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 231NJ HAS LOWER SKIN CRACKED ACCOMPLISHED REPAIR ON FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA12175589Floorboard · brokenINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD NR 231LJ HAS LOWER SKIN BROKEN, UPPER SKIN PUNCTURED AND INSERTS CORRODED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA12175588Floorboard · damagedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 222EG HAS LOWER SKIN TORN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR FDEA201209273468Floorboard · damagedMAIN DECK CARGO FLOORBOARD 242ZJ CRUSHED AT UPPER SIDE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR IPXA12575597Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XHF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575595Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 232XGF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12575594Floor Panel · crackedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 231XLF CRACKED ON EDGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2575565Floorboard · crushedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 251XKF UPPER SURFACE FORWARD OF CORNER AND THE CORNER IS CRUSHED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-969 2-H.SDR IPXA2575564Floor Panel · brokenINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XQF HAS TWO BROKEN INSERTS FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR C77A20120928005Floor Support · corrodedRT FWD FLOOR SUPPORT HAS CORROSION BETWEEN FR13 AND FR14. X=4011.0 - 4270.0, Y=920 TO 1092.2, Z=490.0. R & R FLOOR SUPPORT IAW SRM 51-41-01 AND 51-43-01.SDR FDEA201209263453Floorboard · damagedAFT CARGO BAY FLOORBOARD 151VF HAS 25 SQUARE INCHES OF DAMAGED CORE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201209253439Floor Panel · damagedMAIN DECK CARGO FLOOR PANEL 231VG HAS FOUR AREAS OF IMPACT DAMAGE, FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201209253436Floor Panel · crackedMAIN DECK CARGO FLOOR PANEL 232CF HAS THREE CRACKS FROM 2-4 INCHES. FABRICATED FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR DALA12008813126Floor Panel · damagedAFT CARGO FLOOR PANEL 161NF DAMAGED "2 X 2". FABRICATED FLOOR PANEL IAW DWG 3D25-40532.SDR DALA12008733126Floor Panel · damagedAFT CARGO FLOOR PANEL 151CE DAMAGED MULTIPLE PUNCTURES "2 X 2". FABRICATED FLOOR PANEL IAW DWG 3D25-40532.SDR DALA12008723126Floor Panel · damagedAFT CARGO FLOOR PANEL 151ZG DAMAGED "3 X 3". FABRICATED FLOOR PANEL IAW DWG 3D25-40532.SDR DALA12008703126Floor Panel · damagedFORWARD CARGO FLOOR PANEL 131CG DAMAGED "4 X 4". FABRICATED FLOOR PANEL IAW DWG 3D25-40532.SDR DALA12008673126Floor Panel · puncturedFORWARD CARGO FLOOR PANEL 131AF MULTIPLE PUNCTURES "3 X 3". FABRICATED FLOOR PANEL IAW DWG 3D25-40532.SDR DALA12008623126Floor Panel · damagedAFT CARGO FLOOR PANEL 151VG DAMAGED 3" X 3". FLOOR PANEL FABRICATED NEW IAW DWG 3D25-40532. DAMAGE DIA L=3.0" X W=3.0".SDR IPXA2675485Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL POS 5L DENTED. REPAIRED FLOOR PANEL IAW SRM 53-00-50-2R.
Back to JASC 5321