JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12002633128Floor Panel · corrodedAFT CABIN UTILITY FLOOR PANEL 261FF HAS CORROSION. REPLACED FLOOR PANEL 261FF WITH NEW FLOOR PANEL 261FF IAW SRM 51-72-11. FLOOR PANEL INSTALLED ON WORKCARD 2500-6602.SDR USAA2012070500005Floor Panel · delaminated2S CHECK - AFT CARGO FLOOR PANEL DELAMINATED FROM BS 2456 TO BS 2616,Y -765 TO Y 765. REMOVED AND REPLACED FLOOR PANEL.SDR IPXA2574139Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 241XEF HAS A PUNCTURE. FABRICATED NEW PANEL IAW EO B757-5320-9692-H.SDR USAA2012080300009Floor Panel · corroded2S CHECK - CORROSION ON NUMEROUS SCREW INSERTS ON FLOOR PANEL 222CF BETWEEN FR12 TO FR16 & BETWEEN -Y765 TO -Y1725. REPLACED FLOOR PANEL 222CF, TO BE INSTALLED ON JOB CARD 26C22053014.SDR USAA2012072500011Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252GG BETWEEN FR55 TO FR59 & BETWEEN -Y1272 TO -Y1732. REPLACED FLOOR PANEL 252GG IAW JOB CARD 26C25053014.SDR USAA2012071600021Floor Panel · corrodedQ1 CHECK - CORROSION AROUND 10 FASTENER HOLE ON FLOOR PANEL 221PF BETWEEN FR12 TO FR16 & BETWEEN -Y294 TO -Y1795. REPLACED FLOOR PANEL 221PF. INSTALLATION ACCOMPLISHED ON JOB CARD 26C22053014.SDR IPXA12574253Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 241XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR USAA2012070900037Floor Panel · corroded2S CHECK - CORROSION AND DISBONDING ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20, -Y1292 TO -Y1729. REPLACED FLOOR PANEL 222FF IAW JOB CARD 26C26053014.SDR USAA2012070900036Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261BG BETWEEN FR64 TO FR66, Y765 TO Y1732. REPLACED FLOOR PANEL 261BG IAW JOB CARD 26C26053014.SDR IPXA2574151Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO BAY FLOOR PANEL 231XLF HAS A PUNCTURE 18" AFT OF FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574150Floor Panel · puncturedINSPECTION TYPE: C MAIN CARGO BAY FLOOR PANEL 241XBF HAS HOLE DRILLED THROUGH IT, 8" AFT OF FWD EDGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574148Floorboard · delaminatedINSPECTION TYPE: C MAIN CARGO BAY FLOORBOARD 241XMF IS DELAMINATED AT AFT CORNER. FABRICATED FLOORBOARD.SDR IPXA2574144Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO BAY FLOOR PANEL 242XGF HAS NUMEROUS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574138Floor Panel · puncturedINSPECTION TYPE: C, MAIN CARGO BAY FLOOR PANEL 241XJF HAS NUMEROUS PUNCTURES. FABRICATED MAIN CARGO COMP FLOOR PANEL IAW EO B757-5320-9692-H.SDR USAA2012062800019Floor Panel · delaminated2S CHECK AFT CARGO FLOOR PANEL BETWEEN FR 50 AND FR 53, S38L TO S38R AT Z-500 IS DELAMINATED (24 IN X 31 IN AREA). REMOVED AND REPLACED PANEL IAW A321 AMM 53-42-17-400-001-A.SDR ASOA2012062801834Floor Panel · crackedRIGHT ELECTRICAL BAY FLOOR AT FS 193 IS CRACKED. REPAIRED IAW REO 670-53-11-509.SDR USAA2012072500010Floor Panel · corroded2S CHECK - NUMEROUS CORRODED FASTENER HOLES ON FLOOR PANEL 261PF BETWEEN FR68 TO FR70 & BETWEEN Y1725 TO -Y1725. REPLACED FLOOR PANEL 261PF IAW A319 SRM 51-42-11 PARA 2.SDR USAA2012071600022Floor Panel · delaminatedQ1 CHECK - DELAMINATION ON FLOOR PANEL 262BG BETWEEN FR64 TO FR66 & BETWEEN -Y765 TO -Y1732. REPLACED FLOOR PANEL 262BG. INSTALLATION ACCOMPLISHED ON JOB CARD 26C26053014.SDR DALA12002503128Floor Panel · damagedAFT CARGO FLOOR PANEL 151ZG MISSING INSERTS. FABRICATED FLOOR PANEL IAW DWG 3D25-40532. DAMAGE DIM L=1.0 INCH W=1.0 INCH.SDR DALA12002493128Floor Panel · damagedAFT CARGO FLOOR PANEL 151PE DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-40532. DAMAGE DIM L=6.0 INCH W=3.0 INCH.SDR DALA12002483128Floor Panel · damagedAFT CARGO FLOOR PANEL 151VG DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-40532. DAMAGE DIM. L=4.0 INCH W=2.0 INCH.SDR DALA12002473128Floor Panel · damagedFORWARD CARGO FLOOR PANEL 131AF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-40532. DAMAGE DIM L=2.0 INCH W=1.0 INCH.SDR DALA12002463128Floor Panel · damagedFORWARD CARGO SLOPE FLOOR PANEL 131CG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532. DAMAGE DIM L=2.0 INCH W=1.0 INCH.SDR USAA2012062800018Floor Panel · delaminated2S CHECK - AFT CARGO FLOOR PANEL AT FR 42, Y-765 AND Z-500 IS DELAMINATED (6 IN X 4 IN AREA). REMOVED AND REPLACED FLOOR PANEL MCGILL IRM 9701 REV G.SDR ASOA2012062801832Floor Panel · crackedRIGHT ELECTRICAL BAY FLOOR AT FS 193 IS CRACKED. CUT OUT CRACK IAW REO 670-53-11-509. COMPLIED WITH STEP 11 OF EC/TC REO 670-53-11-509 IAW NDTM PART 1, 51-20-006. NO CRACK INDICATIONS NOTED. FABRICATED AND INSTALLED DOUBLER IAW REO 670-53-11-509.SDR ASOA2012062801831Floor Panel · crackedLEFT ELECTRICAL BAY FLOOR AT FS 193 IS CRACKED. COMPLY WITH ECTC REO 670-53-11-509. COMPLIED WITH ECTC REO 670-53-11-509 AND REO 670-53-11-509, REV.SDR DALA12002163128Floor Panel · damagedCOCKPIT FLOOR PANEL 221LF DAMAGED. REPLACED FLOOR PANEL WITH NEW IAW SRM 51-72-11. DAMAGE DIM: 4.0 INCH BY 3.0 INCH.SDR IPXA2174088Floor Panel · damagedMAIN CARGO DECK POS 9R/10R OTBD FLOOR PANEL DAMAGED. REPAIRED IAW EO B757-5320-42721-B & SRM 53-10-20.SDR IPXA2174143Floorboard · damagedINSPECTION TYPE: SV, MAIN CABIN FLOORBOARD 231KJ HAS DAMAGED INSERT. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD IAW EO A300-5320-16407-E, APPENDIX B.SDR IPXA2174137Floorboard · delaminatedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 231LJ HAS UPPER SKIN PUNCTURED AND HAS CORRODED INSERT AND LOWER SURFACE DELAMINATED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231LJ IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174136Floorboard · delaminatedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 221EG HAS LWR SKIN DELAMINATED AT CORNER. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 221EG IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174135Floorboard · puncturedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 222DG HAS LOWER SKIN PUNCTURED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 222DG IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174134Floorboard · delaminatedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 231RG HAS UPPER SKIN PUNCTURED AND LOWER SKIN DELAMINATED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231RG IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174133Floorboard · crackedINSPECTION TYPE:SV MAIN CABIN FLOORBOARD NR 231WG HAS LWR SKIN CRACKED AND UPPER SKIN PUNCTURED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231WG IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174131Floorboard · crackedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 231MJ HAS LWR SKIN CRACKED AND UPPER SKIN IS PUNCTURED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231MJ IAW EO A300-5320-42721-B, PARA 6A.SDR FDEA201206242334Floor Panel · corrodedFLOOR PANEL NR 162HF HAS CORROSION TOP SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206242333Floor Panel · delaminatedFLOOR PANEL NR 161CF BACK SIDE HAS DELAMINATION ON EDGE. FLOOR PANEL DAMAGE IS BEYOND REPAIR. FABRICATED FLOOR PANEL IAW DWG SRZ-25-005 REV J & DWG SRZ-25-011, REV D.SDR DALA1238710679Floor Panel · corrodedCORROSION ON MAIN CABIN DECKPLATE, BS 1680-1718, BL 0 - RBL 55. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51 PG 201 FIG 201. REPAIRED IAW SRM 53-60-51 P. 201 FIG 201 REPAIR 2 ALTERNATIVE I.SDR DALA1238690679Floor Panel · corrodedCOROSION ON MAIN CABIN DECKPLATE BS 1715, BL0 TO RBL2.5. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51 PG 201 FIG 201 REPAIR 2. REPAIRED IAW SRM 53-60-51 PG 201 FIG 201 REPAIR 2 ALTERNATIVE I.SDR DALA1238680679Floor Panel · corrodedCORROSION ON MAIN CABIN DECKPLATE, BS 1680 TO 1718, BL 0 TO 55. CORROSION REMOVED PER SRM 53-60-51 PAGE 201 FIG 201. INSTALLED REPAIR DOUBLER AND SHIMS IAW SRM 53-60-51 PG 201 FIG 201 REPAIR 2 ALTERNATIVE I.SDR IPXA2174127Floorboard · puncturedINSPECTION TYPE:1C, MAIN CABIN FLOORBOARD NR 231NJ HAS A HOLE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231NJ IAW EO A300-5320-42721-B, PARA 6A.SDR FDEA201206232306Floor Panel · damagedFLOOR PANEL 241LK IS BROKEN. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206232305Floor Panel · damagedAFT CARGO FLOOR PANEL 151UF HAS TWO DAMAGED CORNERS APPROX TEN SQUARE INCHES. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206232304Floor Panel · damagedAFT CARGO FLOOR PANEL 151WF HAS TWO DAMAGED CORNERS APPROX NINE SQUARE INCHES. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206222299Floor Panel · crackedFLOOR PANEL 242QJ, HAS TWO, TEN INCH CRACKS. FARICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206222298Floor Panel · damagedFLOOR PANEL 132MG, BACKSIDE OF PANEL HAS SEVERAL CRUSHED HONEYCOMB CORE & FOUR MISSING INSERTS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206222297Floor Panel · crackedFLOOR PANEL 242ZJ HAS ONE, TEN INCH CRACK. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206222296Floor Panel · crackedFLOOR PANEL 242EK HAS TWO, TEN INCH CRACKS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206222295Floor Panel · crackedDURING INSTALLATION, FOUND FLOOR PANEL 252BF CRACKED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA2174117Floorboard · puncturedINSPECTION TYPE:1C, MAIN CABIN FLOORBOARD NR 231TH UPPER SKIN IS PUNCTURED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231TH IAW EO A300-5320-42721-B, PARA 6A.
Back to JASC 5321