JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201206082158Floorboard · damagedFLOORBOARD 162HF HAS IMPACT DAMAGE OVER 50 PERCENT OF PANEL. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005 REV J, REF DWG SRZ 25-011.SDR FDEA201206072121Floor Panel · damagedNR 241TH FLOOR PANEL UPPER SURFACE HAS IMPACT DAMAGE. REMOVED FLOOR PANEL IAW AMM 53-10-25-4. FABRICATED A NEW FLOOR PANEL IAW SRM 53-10-20, MC. INSTALLED FLOOR PANEL IAW AMM 53-10-25-4. THE REPAIR EVALUATED IAW GMM 6-2-100 AND CLASSIFIED AS MINOR.SDR IPXA2573956Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XJF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12173872Floor Panel · damagedINSPECTION TYPE: 1C, FLOOR PANEL 231MJ ATTACH INSERT DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B, APPENDIX B.SDR FDEA201206062112Floorboard · damagedFWD CARGO FLOORBOARD 132RF DAMAGE ON THE EDGE ABOUT 3 FT. LONG. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206062110Floorboard · delaminatedFLOORBOARD 242ZJ DELAMINATED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206062109Floorboard · damagedFLOORBOARD 231AH HAS FIVE CRUSHED AREAS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206062108Floorboard · damagedFLOORBOARD 231NH HAS THREE CRUSHED AREAS 5 INCHES LONG. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR IPXA2573907Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD BS 560-611 HAS FIBER DAMAGE. FABRICATE FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2573887Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD BS 480-560 FIBER DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR DALA12001423122Floor Panel · delaminatedFORWARD CARGO FLOOR PANEL 131CG DELAMINATED. FABRICATED NEW FLOOR PANEL 131CG IAW DWG 3D25-40532. DAMAGE DIM: L=4.0 W=4.0. RETAIN FOR RECORDS.SDR FDEA201206052095Floorboard · damagedFLOORBOARD 241MK CRUSHED ON EDGE & FOUR SEPARATE DELAMINATION AREAS ON UPPER SURFACE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206052093Floorboard · corrodedFLOORBOARD 251GH HAS CORROSION AT HONEYCOMB CORE OUTER EDGES. FABRICATED REPLACEMENT FLOORBOARD IAW SRZ 25-005, REV J.SDR FDEA201206052092Floorboard · delaminatedFLOORBOARD 242EK DELAMINATED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206052091Floorboard · damagedFLOORBOARD 162EF HAS COMPOSIT DAMAGE TO LOWER SURFACE AND HAS ONE DAMAGED HOLE GROMET, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J & SRZ 25-011.SDR FDEA201206052089Shear Plate · crackedSHEAR PLATE LT SIDE WEB CRACKED BETWEEN FR79-FR80. R & R SHEAR PLATE WEB ON FLOOR LT SIDE BETWEEN FR79-FR80 IAW SRM 51-72-10, PG 1.SDR ASOA2012061401782Floor Panel · crackedLT TRU FLOOR IS CRACKED ADJACENT TO BRAKE ACCUMULATOR GAUGES. REPAIR IAW REO EC/TC 670-53-11-509 BT161750. COMPLIED WITH EC/TC REO 670-53-11-509 GENERIC REO 670-53-11-509 REV.-- DATED 07/06/2010 AS WRITTEN ON LT SIDE. RII FOUND TO BE SATISFACTORY. (SDR CLOSESDR FDEA201206042080Floor Panel · crackedFLOOR PANEL 242UJ HAS TWO, 10 INCH CRACKS. FABRICATED FLOOR PANEL 242 UJ IAW DWG NR SRZ 25-005, REV J.SDR FDEA201206042079Floorboard · delaminatedFLOORBOARD 231HG UPPER SURFACE DISBONDED AT AFT OTBD CORNER 10 SQUARE INCHES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206042078Floorboard · damagedFLOORBOARD 232NG HAS 7 PUNCTURES ON TOP SURFACE, FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206042077Floorboard · delaminatedMLG WHEEL WELL FLOORBOARD 147AF TOP COATING IS DEBONDED ABOUT 12 FT SQUARE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201206042076Floor Panel · damagedFLOOR PANEL 232YH UPPER SURFACE GOUGED 8 SQUARE INCHES. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA12573843Floor Panel · damagedMAIN DECK FLOOR PANEL 12R DAMAGED. REPAIRED REF SRM 53-00-50-2R.SDR IPXA12573857Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 242XGF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573853Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 242XBF HAS A BROKEN INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573852Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 241XJF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573851Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 242XFF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573850Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 241XLF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573849Floorboard · delaminatedINSPECTION TYPE: C, CABIN FLOORBOARD 241XKF IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573848Floorboard · brokenINSPECTION TYPE: C, CABIN FLOORBOARD 242XMF HAS A BROKEN INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12573847Floorboard · brokenINSPECTION TYPE: C, CABIN FLOORBOARD 241XCF HAS A BROKEN INSERT. FABRICATED NEW FLOORBOARD 241XCF IAW EO B757-5320-9692-H.SDR DALA12001353122Floor Panel · damagedAFT CARGO FLOOR PANEL 151ZG DAMAGED. FLOOR PANEL 151ZG WAS FABRICATED IAW DRAWING 3D25-40532. DAMAGED DIM: L=1.0' W=2.0" D=0.33". RETAIN FOR RECORDS. STRINGER 645112 BFM.SDR DALA12001343122Floor Panel · damagedAFT CARGO FLOOR PANEL 161NF DAMAGED. FLOOR PANEL 161NF WAS FABRICATED IAW DRAWING 3D25-40532. DAMAGED DIM: L=6.0 INCH W=4.0 INCH D=0.25 INCH. RETAIN FOR RECORDS, STRINGER 645112 BFM.SDR DALA12001333122Floor Support · damagedAFT CARGO FLOOR PANEL 151VG EDGE DAMAGE. FLOOR PANEL 151VG WAS FABRICATED IAW DRAWING 3D25-40532. DAMAGED DIM: L=4.0 INCH W=3.0 INCH D=0.1 INCH. RETAIN FOR RECORDS. STRINGER 645112 BFM.SDR DALA12003443131Floor Panel · delaminatedDURING INSPECTIONS, FOUND FWD CARGO FLOOR PANEL 131AF DELAMINATED. REPLACED FLOOR PANEL IAW SRM 51-72-11.SDR USAA2012061200002Floor Panel · delaminated3S CHECK - DELAMINATION ON FLOOR PANEL 232PF BETWEEN FR24 TO FR28, BETWEEN Y-1732 TO Y-1292. REPLACED FLOOR PANEL 232PF IAW A320 SRM 53-02-00, TABLE 103 AND IRM 9701 REV G.SDR IPXA2573888Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 242XKF DELAM 45" FWD FROM AFT END FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12673842Floor Panel · damagedMAIN DECK FLOOR PANEL NR 6 CTR AFT FLOOR HOLE. 2.0625 DIA 9" FROM LT EDGE, 46" FROM FWD. REMOVED DAMAGE REF SRM 53-00-50-2R. 2.0625 DIA. REMOVED IAW 53-00-5 0-2R, C/W SRM 53-00-50-2R, PARA 4 E. (8).SDR IPXA12673841Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL NR 8 HAS 2 AT HOLES, 2 MEASURE 1.2500" DIA. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12673840Floor Panel · damagedMAIN CARGO DECK NR 2L AFT, HOLE IN FLOOR PANEL, 3RD PANEL FROM LT OTBD 2.0625 HOLE 9.5" FROM INBD EDGE. 79.2500 FROM FWD EDGE. 2 EA HOLES 75.5" FROM FWD EDGE 7" FROM INBD EDGE, 4/3/4 FROM INBD EDGE 1.2500" DIA. REMOVED DAMAGE REF SRM 53-00-50-2R, 2.0625 DIA DSDR IPXA12673839Floor Panel · dentedFLOOR PANEL NR 1, MAIN CARGO DECK RBL 45 28" FROM AFT EDGE HAS HOLE IN UPPER SKIN. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12673838Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL 2R, TEN INCHES FWD OF POS 3, RBL 16 DAMAGED 2.0625 HOLE. REMOVED DAMAGE REF SRM 53-00-50-2R, 2.0625 DIA. DAMAGE VERIFIED REMOVED IAW SRM 53-00-50-2R, REPAIRE IAW SRM SRM 53-00-50-2R PAR A 4.D. (8).SDR C77A20120603006Floor Panel · corrodedCENTER SHEAR PANEL, CORRODED ON AND AROUND RIVETS AT FRAME 87. REMOVED CORROSION BY BLENDING AND TREATING IAW SRM 51-10-03 & 51-12-01.SDR USAA2012061900004Floor Panel · delaminated2S CHECK - DELAMINATION ON SEAT FLOOR PANEL 212EF BETWEEN FR6 TO FR12 & BETWEEN -Y765 TO -Y254. REPLACED SEAT FLOOR PANEL 212EF IAW A319 SRM 53-12-00 DIAGRAM 102 & IRM 9701 REV G.SDR DALA12001293122Floor Panel · corrodedFLOOR PANEL 222FF IS CORRODED. RECEIVED NEW FLOOR PANEL 222FF FLOOR PANEL 222FF TO BE INSTALLED ON WORK CARD 2500-6617.SDR C77A20120601002Floor Panel · corrodedLEDT DOUBLER FLOOR BETWEEN FRAMES 19 AND 19A CORRODED. REMOVED CORROSION BY BLENDING AND TREATING IAW SRM 51-10-03 & 51-12-01.SDR FDEA201206012050Floor Panel · crackedFLOOR PANEL 231CF HAS 28 INCHES OF CHAFFING SKIN & A 7 INCH CRACK. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206012049Floor Panel · chafedFLOOR PANEL 231EF HAS THIRTY TWO SQUARE INCHES OF CHAFFING ON UPPER SKIN. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201206012047Floor Panel · crackedFLOOR PANEL 252WH HAS ONE, NINE INCH CRACK, FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005 REV JSDR FDEA201206012045Floor Panel · damagedFLOOR PANEL 251RT BROKEN ACROSS ENTIRE MID-SECTION OF PANEL FABRICATED. REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.
Back to JASC 5321