JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2572867Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 241XKF IS DELAMINATED AT FWD AND AF T CORNERS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572866Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 241XJF HAS DAMAGE, MISSING AND CORRODED FASTENER INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-4.SDR IPXA2572864Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 241XMF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572863Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 241XLF DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572862Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 232MF DAMAGED. FABRICATED NEW FLOORBOARD 232MF IAW EO B757-5320-9692-H.SDR IPXA2572826Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 251XAF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572825Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 251XCF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572824Floorboard · damagedINSPECTION TYPE:C. FLOORBOARD 251XDF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572823Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 251XJF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572821Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD 252XAF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572820Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 222XBF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572817Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 251XQF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572816Floorboard · delaminatedINSPECTION TYPE: C, FLOORBOARD 252XCF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572815Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 252XHF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572814Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 252XQF HAS EDGE BROKEN. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572813Floorboard · delaminatedINSPECTION TYPE: C, FLOORBOARD 252XLF HAS EDGE DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572812Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XNF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572811Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XKF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572810Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XPF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572809Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XLF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572808Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 252XPF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572807Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XFF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572806Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 252XKF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572805Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 241XFF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572804Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 241XGF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA2572803Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 251XBF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR USAA2012043000017Floor Panel · broken2S CHECK - BROKEN FLOOR PANEL 211JF LOCATED BETWEEN FR6 TO FR12 & BETWEEN -Y254 TO Y254. REPLACED FLOOR PANEL 211JF IAW A319 SRM 53-12-00; IRM 9701 REV G & AIRWAYS EA 500628.SDR USAA2012042000007Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 261PF BETWEEN FR38 TO FR70 & BETWEEN Y1292 TO -Y292. REPLACED FLOOR PANEL NR 261PF IAW A319 SRM 53-02-00 PAR 8G & IRM 9701 REV G.SDR IPXA12573057Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 252, LBL 12 HAS AREA OF CORROSION. REMOVED CORROSION. ORIG THICKNESS .050, REMAINING .047, LOSS OF .003. RESTORED FINISH IAW EA 120525 IR AND EO B757-5310-46773-A.SDR IPXA12573055Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 273, LBL 25 HAS AREA OF CORROSION. REMOVED CORROSION. ORIG THICKNESS .050, REMAINING .047, LOSS OF .003. RESTORED FINISH IAW EA 120525 IR AND EO B757-5310-46673-A.SDR IPXA12573054Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 270.5 RBL 8 HAS AREA OF CORROSION. REMOVED CORROSION. ORIG THICKNESS .050, REMAINING .047, LOSS OF .003. RESTORED FINISH IAW EA 120525 IR AND EO B757-5310-46773-A.SDR IPXA12573053Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 270.5 RBL 9 HAS AREA OF CORROSION. REMOVED CORROSION. ORIGINAL THICKNESS .050, REMAINING .046 LOSS OF .004. RESTORED FINISH IAW EA 120525 IR AND EO B757-5310-46773-A.SDR IPXA12173028Floorboard · puncturedINSPECTION TYPE: 10YR, BULK CARGO FLOORBOARD 162HF IS PUNCTURED IN SEVERAL PLACES. FABRICATED BULK CARGO FLOORBOARD IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA2172879Floorboard · debondedINSPECTION TYPE: 10YR, BULK CARGO FLOORBOARD NR 161JF IS DISBONDING AT PREVIOUS REPAIR. FABRICATED BULK CARO FLOORBOARD IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA2172870Floorboard · crackedINSPECTION TYPE: 10YR, AFT CARGO FLOORBOARD 151QF IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR ASOA201201127Floor Panel · crackedFWD EQUIPMENT BAY FLOOR CRACKED ON LT SIDE JUST OTBD OF BRAKE ACCUMALATOR GAUGES. COMPLIED WITH REO 670-53-11-509 AND REO 670-53-11-509 REV.SDR ASOA201201125Floor Panel · crackedFWD EQUIPMENT FLOOR CRACKED ON RT SIDE NEXT TO ADG PUMP. COMPLIED WITH REO 670-53-11-509 AND REO 670-53-11-509 REV.SDR DALA1220529255Floor Skin · crackedCOCKPIT FLOOR WEB CRACKED UNDER F/O SEAT AT BS 160 RBL 22. INSTALLED REPAIR DOUBLER PER SRM 53-00-01 VOL I.SDR IPXA12573058Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 255 LBL 14 HAS AREA OF CORROSION. REMOVED CORROSION ORIGINAL THICKNESS .050, REMAINING .048, LOSS OF .002. RESTORED FINISH IAW EA 120525 AND EO B757-5310-46773-A.SDR IPXA12573056Floor Panel · corrodedINSPECTION TYPE: C, CONTROL CABIN FLOOR BS 273, LBL 27 HAS AREA OF CORROSION. REMOVED CORROSION. ORIG THICKNESS .050, REMAINING .048, LOSS OF .002. RESTORED FINISH IAW EA 120525 IR AND EO B757-5310-46773-A.SDR IPXA12572783Floorboard · damagedINSPECTION TYPE: C, FLOORBOARD 212XAF HAS DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR FDEA201204021255Crease Beam · corrodedMAIN CABIN LT SIDE AT BS 860 CREASE BEAM OTBD CHORD WITH CORROSION. REMOVED CORROSION IAW SRM 53-30-13, FOUND OUT OF LIMITS IAW SRM 53-30-13, FIG 101, SHEET 5. R & R CREASEBEAM IAW SRM 53-30-13 AND DWG 143N5520- 27, FROM BS 760-900, LT SIDE. MAJOR REPAIR.SDR DALA1220476818Channel · corrodedHAT CHANNEL HAS CORROSION. REMOVED CORROSION AND CHECKED LIMITS PER SRM 53-00-51, FOUND TO BE OUT OF LIMITS. REMOVED SUPPORT. LOCATED HAT CHANNEL AND DRILLED REF DWG 146N5300. INSTALLED CHANNEL PER DWG 146N5300.SDR IPXA12672735Floor Panel · damagedMAIN CARGO DECK POS 2L AFT HOLE IN FLOOR PANEL. REPAIRED IAW SRM 53-00-50-2R, PARA 4B.SDR IPXA12672734Floor Panel · damagedMAIN CARGO DECK POS 2L FWD HOLE IN FLOOR PANEL, OTBD PANEL 4"X1" DAMAGED HONEYCOMB. REPAIRED IAW SRM 53-00-50-2R 4C.SDR IPXA12672731Floor Panel · damagedFLOOR PANEL HAS DAMAGE AT DEF D473437 AND D473438 POS 1 ON MAIN CARGO DECK. FABRICATED FLOOR PANEL REF EO B767-5320-9693-H.SDR IPXA12572782Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 211XAF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR AALA20120401003Floor Panel · corrodedCORROSION ON AFT PRESSURE DECK FROM BS 1681 TO 1720. REPLACED AFT PRESSURE DECK SRM 51-10-02-0G.SDR IPXA12672720Floor Panel · damagedMAIN CARGO DECK POS 2L MID 2 HOLES IN FLOOR PANEL WITHIN 2" OF EA OTHER. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA12672719Floor Panel · damagedMAIN CARGO DECK POS 2L MID HOLE IN FLOOR PANEL. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.
Back to JASC 5321