JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2571318Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 231XWF DELAMINATED AND INSERTS DAMAGE. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 231XWF IAW B757-5320-9692-H.SDR IPXA2571317Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 231XUF DELAMINATED AND EDGE DAMAGED. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 231XUF IAW B757-5320-9692-H.SDR IPXA2571314Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 252XRF EDGE DAMAGED AND BROKEN INSERTS. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 252XRF IAW B757-5320-9692-H.SDR IPXA2571313Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 232XWF DELAMINATED AND INSERT DAMAGED. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 232XWF IAW B757-5320-9692-H.SDR IPXA2571312Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 252XSF EDGE DAMAGED AND BROKEN INSERTS. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 252XSF IAW B757-5320-969 2-H.SDR IPXA2571308Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 242XGF EDGE DAMAGED AND INSERTS DAMAGED. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 242XGF IAW B757-5320-969 2-H.SDR IPXA2571307Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 242XHF EDGE DAMAGED AND INSERTS DAMAGED. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 242XHF IAW B757-5320-969 2-H.SDR IPXA2571305Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 252XBF EDGE DAMAGE AND BROKEN INSERT. FABRICATED MAIN CARGO COMPARTMENT FLOORBOARD 252XBF IAW B757-5320-969 2-H.SDR IPXA2571303Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR BOARD 232XMF DELAMINATED. FABRICATED MAIN CARGO COMPARTMENT FLOOR BOARD 232XMF IAW B757-5320-969 2-H.SDR DALA1204193118Floor Panel · corrodedFORWARD UTILITY FLOOR PANEL 222FF CORRODED. REPLACED PANEL 222FF ON WORKCARD 2500-6617. CORROSION DIM THICKNESS=.380" L=1.50" W=.250" D=.063".SDR DALA1205023118Floor Panel · delaminatedAFT PIT FLOOR PANEL 151ZG IS DELAMINATED AND PUNCTURED 10- X 8- AREA. FABRICATED NEW FLOOR PANEL 151ZG PER DWG 3D25-40532 DIA OF DAMAGE 10- X 8-.SDR DALA1205013118Floor Panel · delaminatedAFT PIT FLOOR PANEL 161NF IS DELAMINATED AND PUNCTURED 7- X 5- AREA. FABRICATED NEW FLOOR PANEL 161NF PER DWG 3D25-40532 DIA OF DAMAGE 7" X 5".SDR DALA1204373118Floor Panel · delaminatedFWD PIT FLOOR PANEL 132DG IS DELAMINATED AND BROKEN, 4" X 4" AREA. FABRICATED NEW FLOOR PANEL 132DG PER DWG 3D25-40532.SDR DALA1204363118Floor Panel · delaminatedAFT PIT FLOOR PANEL 151VG IS DELAMINATED AND MISSING UPPER SURFACE MATERIAL, 3- X 2- AREA. FABRICATED NEW FLOOR PANEL 151VG PER DWG 3D25-40532. DAMAGED AREA 3" X 2".SDR DALA1204133212Floor Panel · delaminatedDURING NON ROUTINE CHECK, MAINTENANCE REMOVED AFT CARGO FLOOR PANEL 151PF DUE DELAMINATION. FABRICATED AFT CARGO FLOOR PANEL 151PF ON STAM TRAVELER # T12/913710 IAW DRAWING 3D25-37705 MATERIAL A402AB-60X144 BATCH# 2105510. DAMAGE DIM. L=42" W=21". INSTALLEDSDR FDEA201201240319Floorboard · crackedFLOORBOARD 232 JG IS CRACKED AT CUTOUT APPROX 9". FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR USAA2012012400014Floor Panel · delaminatedRON - SOFT FLOOR PANEL 251AF BETWEEN FR47 TO FR51. REPAIRED FLOOR PANEL 251AF BETWEEN FR47 TO FR51 IAW A320 SRM 53-02-00 FIGURE 208.SDR ASOA201200343Floor Panel · crackedFORWARD EQUIPMENT COMPARTMENT BAY FLOOR CRACKED ON RT SIDE UNDER ADS STOW PUMP. COMPLY WITH EC/TC REO 670-53-11-505. COMPLIED WITH EC/TC REO 670-53-11-509 AND GENERIC REO 670-53-33-509 REV. RII FOUND TO BE SATISFACTORY.SDR ASOA201200341Floor Panel · crackedFORWARD EQUIPMENT COMPARTMENT BAY FLOOR CRACKED ON LT SIDE OF BRAKE ACCUMALATOR GOUGED. COMPLY WITH EC/TC REO 670-53-11-509. COMPLIED WITH EC/TC REO 670-53-11-509 AND GENERIC REO 670-53-11-509 REV. RII FOUND TO BE SATISFACTORY.SDR DALA1203913118Floor Panel · corrodedAFT UTILITY FLOOR PANEL 262FF CORRODED. DAMAGED L=2.0" W=1.0" D=.012" ORIG MAT. .032". REPLACED FLOOR PANEL 262FF.SDR IPXA12571233Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 241XJF IS DELAMINATED. FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL 241XJF IAW EO B757-5320-9692-H.SDR FDEA201201230308Floorboard · damagedFWD CARGO FLOORBOARD 132 QG HAS IMPACT DAMAGE AT LWR SURF TOTAL DEFECT MEASURES 60 IN LONG W/PUNCTURE. FABRICATED FLOORBOARD 132 QG IAW DWG SRZ 25-005 REV J.SDR FDEA201201230307Floor Panel · crackedMDCC FLOOR PANEL 242 RG HAS 3 EA CRACKS 2" TO 8" CLEVIS ADAPTER CUTOUT. FABRICATED REPLACEMENT FLOOR PANEL 242 RG IAW DWG SRZ 25-005, REV J.SDR DALA1203933118Floor Panel · damagedAFT UTILITY FLOOR PANEL 262EF DAMAGED 4"X 3.5". PANEL 262EF WAS FABRICATED ON TRAVELER T12/911497 IAW DRAWING 3D25-40640. STRINGER 490428 BFMSDR DALA1203923118Floor Panel · damagedAFT UTILITY FLOOR PANEL 262HG DAMAGED 3.5- X 5-. FLOOR PANEL 262HG WAS FABRICATED ON TRAVELER T12/911496 IAW DRAWING 3D25-40640. STRINGER 490428 BFMSDR IPXA12171208Floor Panel · dentedCARGO BAY FLOOR PANEL DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-16407-E.SDR ZZDA2012109Floor Panel · corrodedCABIN FLOOR PANEL, STA 157 TO 200, LBL 44, CORROSION. ACCOMPLISHED FLOOR PANEL FILLER AND DOUBLER REPAIR PER B717 SRM 51-70-10 AND 51-40-02.SDR IPXA12671207Floor Panel · damagedINSPECTION TYPE:PS, MAIN CARGO FLOOR PANEL AT POSITION 2R IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL A402H.SDR IPXA12571206Floor Panel · puncturedPUNCTURE IN MCD FLOOR PANEL, POS 4L, LBL36. REQUIRES REPLACEMENT. FABRICATED REPLACEMENT FLOOR PANEL, DRILLED AND CLEANED HOLES OF DEBRIS INSTALLED INSERTS IAW EO.SDR IPXA2571264Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 232XJF DELAMINATED ON UPPER SURFACE. FABRICATED NEW MAIN CARGO FLOOR PANEL 232XJF IAW EO B757-5320-9692-H.SDR DALA1203853118Floor Panel · corrodedAFT UTILITY FLOOR PANEL 261FF CORRODED (PANEL RACK). REPLACED PANEL 261FF STRINGER 490428 BFM.SDR FDEA201201200281Floorboard · damagedFWD CARGO COMPT FLOORBOARD 132 RG HAS BROKEN MATERIAL AT OUTER EDGE OF ENTIRE FLOORBOARD. FABRICATED REPLACEMENT FLOORBOARD 132, RG IAW DWG SRZ 25-005, REV J.SDR FDEA201201200280Floorboard · damagedFWD CARGO COMPT FLOORBOARD 132 NG HAS IMPACT DAMAGE AT ENTIRE OUTER EDGE. FABRICATED FLOORBOARD 132NG IAW DWG, SRZ 25-005, REV J.SDR IPXA2M71685Floorboard · damagedINSPECTION TYPE:4C, EDGE DAMAGE ON MAIN DECK FLOORBOARD. FABRICATED REPLACEMENT FLOORBOARD ADA7556-522 IAW EO MD11-5320-27386-C AND DWG ADA7556.SDR IPXA12671440Floor Panel · damagedINSPECTION TYPE:C, CARGO COMPARTMENT FLOOR PANEL ASSEMBLY UPPER SKIN AND CORE DAMAGE ABOUT 9"X0.6"0.01" AT STA 1197+89 LBL 4.7 AND RBL 4.7 CUT OUT THE UPPER SKIN AND CORE LXW=1.6"X9.4". REPAIR IAW REV:52 SRM 53-00-50. REPAIR GENERAL FIG 201, PARA 4.D.SDR UALA2012012000439Floor Panel · damagedFLOOR SOFT IN AISLE NEAR 34C AND 35C. FLOOR PANEL AT AISLE ROW 35 - 2" SOFT SPOT, 4" FROM EDGE OF PANEL. ACP'D INTERIM REPAIR PER MM. INSTALLED ALUM METAL 0.071" THICKNESS OVERLAP ON SOFTNESS AREA. REPLACE FLOOR PANEL AT NEXT "C" CHECK.SDR FDEA201201190267Floor Panel · damagedFLOOR PANEL 152 WF HAS ONE BROKEN CORNER AND 5 PUNCTURES IN BOTTOM OF PANEL, FABRICATED REPLACEMENT FLOOR PANEL 152 WF IAW DWG SRZ 25-005, REV J.SDR FDEA201201190265Floor Panel · damagedMDCC FLOOR PANEL 231 FF HAS 40" SQ IN OF UPPER SURFACE DELAMINATION WITH 2" PUNCTURE DAMAGE AND 5 " EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 231 FF IAW DWG SRZ 25-005, REV J.SDR FDEA201201190263Floorboard · delaminatedKEEL BEAM FLOODBOARD 147EF HAS EDGE ON 3 SIDES WITH DELAMINATED AND SKYDROL INTRUSION, 60 SQ IN APPROX. FABRICATED FLOORBOARD 147 EF, DWG SRZ 25-005, REV J.SDR FDEA201201190262Floorboard · damagedFLOORBOARD 151 WF 15 PUNTURES AND ALL CORNERS CRUSHED. FABRICATED REPLACEMENT FLOORBOARD 151WF IAW DWG SRZ 25-005, REV J.SDR FDEA201201190261Floorboard · damagedFLOORBOARD 151FG HAS 15 PUNCTURES ON BOTTOM OF PANEL. FABRICATED REPLACEMENT FLOORBOARD FG IAW DWG SRZ 25-005, REV J.SDR FDEA201201190260Floorboard · damagedFLOORBOARD 151 DL HAS SEVERAL AREAS THAT ARE CRUSHED. FABRICATED REPLACEMENT FLOORBOARD 151DL IAW SRZ 25-005, REV J.SDR UALA2012012000441Floorboard · defectiveGALLEY FLOOR SPONGY AT DOOR 2R. DAMAGE IS INBOARD EDGE 5 X 5 AND 10X2 NON PERFORATION. OK TO CF PER SRM. PERM REPAIR WITHIN 350FH. PANEL NUMBER 262FF PCN#110-4657. CURRENT PTT IS 45211:11. TOTAL AREA IS 45 SQ IN., SRM ALLOWS 69.75, 7.087 X 9.843". REPLASDR ASOA201200202Floor Panel · damagedFLOOR PANEL 251CLF HAS A BROKEN INSERT ON AFT EDGE. REPLACED AND INSTALLED NEW INSERT ON FLOOR PANEL 251CLF IAW REPAIR MANUAL. REPAIR METHOD "L" RC161862.SDR IPXA2571187Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 251XFF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2171184Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 241VM IS CRACKED ON THE LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 241VM IAW EO A300-5320-42721-B.SDR FDEA201201180246Floorboard · damagedCARGO COMPT FLOORBOARD, 132 SG HAS BROKEN EDGE FILLER, IMPACT DAMAGE AT LWR SURFACE TOTAL DEFECT 10 IN LONG. FABRICATED REPLACEMENT FLOORBOARD 132 SG IAW DWG SRZ 25-005, REV J.SDR FDEA201201180244Floorboard · crackedFLOORBOARD 152 JG, HAS 11 CRACKS ON BOTTOM OF PANEL AND 2 CORNERS BROKEN. FABRICATED REPLACEMENT FLOORBOARD 152 JG IAW DWG SRZ 25-005.SDR FDEA201201180239Floor Panel · dentedBULK CARGO COMPARTMENT FLOOR PANEL NR 161GF FOUND DENTED ON SEVERAL LOCATIONS. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. R & R IAW AMM 53-10-35, REV 52.1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201201180238Floor Panel · dentedBULK CARGO COMPARTMENT FLOOR PANEL NR 161JF FOUND DENTED ON SERVERAL LOCATIONS. NEW FLOOR PANEL FABRICATED IAW DWG NR SRZ-25-005 REV J. R & R IAW AMM 53-10-35, REV 52.1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.
Back to JASC 5321