JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011111800005Floor Panel · peeling2S CHECK - PEELING ON FLOOR PANEL 231QF BETWEEN FR28 TO FR32, Y=0, -Z500. REPLACED FLOOR PANEL 231QF IAW MCGILL IRM 9701 REV G.SDR FDEA201111164933Floor Panel · damagedAFT CARGO FLOOR PANEL NR 152WF DAMAGED. FLOOR PANEL REMOVED AND REPLACED AS PER AMM 53-10-33-4 REVISION 52.0. NEW FLOOR PANEL FABRICATED AS PER DWG SRZ25-005 REVISION J. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 113.SDR USAA2011111700015Floor Panel · debondedS2 CHECK - AREA OF DISBOND ON FLOOR PANEL 222EF BETWEEN FR16 TO FR20 & BETWEEN -Y200 TO -Y1292. REPLACED FLOOR PANEL 222EF IAW MCGILL IRM 9701 REV G.SDR USAA2011111700006Floor Panel · delaminatedS2 CHECK - DELAMINATION ON FLOOR PANEL 261DF AT BETWEEN FR66 TO FR68 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 261DF IAW MCGILL IRM 9701 REVISION G.SDR FDEA201111164940Floorboard · delaminatedFLOORBOARD 162 DF UP METAL SKIN DISBONDED FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ25-005 REV J AND DWG SRZ25-011, REV D.SDR FDEA201111164939Floor Panel · delaminatedFLOOR PANEL 231 GH HAS DELAMINATED EDGE FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005.SDR USAA2011111600011Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL BETWEEN FR12 TO FR22 & BETWEEN -Y1456 TO -Y1959. REPLACED FLOOR PANEL BETWEEN FR12 TO FR22 & BETWEEN -Y1456 TO -Y1959 IAW A330 SRM 53-02-00 FIG 211.SDR USAA2011111600010Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL BETWEEN FR32 TO FR37.4 & BETWEEN -Y1456 TO -Y1959. REPLACED FLOOR PANEL BETWEEN FR32 TO FR37.4 & BETWEEN -Y1456 TO -Y1959 IAW A330 SRM 53-02-00 FIG 211.SDR IPXA11670353Floor Panel · damagedMAIN CARGO FLOOR PANEL DAMAGED AT STA 654+98. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA11670352Floor Panel · damagedFLOOR PANEL DAMAGED STA 654+110. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA11670350Floor Panel · damagedMCD FLOOR PANEL POS NR 5 CENTER HAS HOLE STA 654.110 7 INCHES RIGHT OF CENTER. REPAIRED IAW SRM 53-00-50-2R.SDR FDEA201111144910Floor Panel · damagedFLOOR PANEL 231DH HAS 9 INSERTS CORRODED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201111144908Floorboard · damagedFLOORBOARD 231 TG AREA CRUSHED. FABRICATED NEW FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201111144894Floor Panel · corrodedFLOOR PANEL 231LG HAS 4 INSERTS THAT ARE CORRODED AND 1 MISSING. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ25-005, REV J.SDR FDEA201111144922Floorboard · crackedFLOORBOARD 232 NG HAS A PUNCTURE AND A CRACK ON BACK SIDE . FABRICATED REPLACEMENT FLOORBOARD 232 NG IAW DWG SRZ 25-005, REV J.SDR IPXA11670346Floor Panel · damagedMAIN CARGO DECK POS 4 FWD CENTER OF PANEL HAS A HOLE. REPAIRED REF SRM 53-00-50-2R, REPAIR 1.SDR UALA2011111406235Floor Panel · delaminatedRIGHT AISLE AT WING EXT FLOOR SOFT. PANEL DELAMINATION FOUND AT SEAT ROW 21KJ RT AISLE. DELAMINATED AREA IS APPROX ONE FOOT BY ONE FOOT. INTERIM REPAIR PERFORMED PER AMM.SDR FOTR2118614933Floor Skin · crackedLEFT MAIN DECK FLOOR DOUBLER CRACKED ALL THE WAY THRU AT LIGHTNING HOLE, INBD SIDE, LBL 44-52 BETWEEN FS 788-807. REPAIRED ON FASI WO 21186, NR 14933.SDR IPXA11670351Floor Panel · damagedMCD POS 5 CTR FLOOR PANEL HAS HOLE STA 654.98 1 INCH RT OF CTR. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA11B70340Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL BS 950L DAMAGED. REPAIRED IAW SRM 53-00-50.SDR IPXA11670345Floor Panel · damagedMAIN CARGO DECK POSITION 4 AFT CENTER OF PANEL HAS A HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA11670339Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50.SDR IPXA11670338Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50.SDR IPXA11670336Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50.SDR IPXA11670335Floor Panel · damagedMAIN CARGO FLOOR PANEL DAMAGED. REPAIRED IAW SRM 53-00-50.SDR USAA2011111800034Floor Panel · delaminated1S CHECK - DELAMINATION ON FLOOR PANEL 221EF BETWEEN FR16 TO FR20 & BETWEEN Y260 TO Y1292. REPLACED FLOOR PANEL 221EF IAW JOB CARD 26C22053014.SDR FDEA201111124886Floorboard · damagedFLOORBOARD 161GF HAS 3 EA PUNCTURES 1 IN LONG AND 1 EA, 3 IN LONG. FABRICATED REPLACEMENT FLOORBOARD 161GF IAW DWGS SRZ 25-005, REV J.SDR FDEA201111124885Floorboard · crackedFLOORBOARD 231QG CRUSHED AT CORNER AND SIDE ALSO CRACKED COMPOSITE 2 PLACES. FABRICATED REPLACEMENT FLOORBOARD 231QG IAW DWG SRZ 25-005, REV J.SDR FDEA201111124883Floorboard · crackedMAIN DECK ZONE 240 FLOORBOARD 242 JF BROKE IN HALF. MAIN DECK ZONE 240 FABRICATED NEW FLOORBOARD 242 JF IAW DWG SRZ 25-005.SDR USAA2011111400016Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 151GF BETWEEN FR53 TO FR56, -Z1500 & BETWEEN Y1000 TO -Y1000. REPLACED FLOOR PANEL 151GF IAW A321 AMM 53-42-14-400-001.SDR IPXA11570330Floor Panel · damagedHOLE IN MAIN CARGO DECK FLOOR PANEL AT POS 13/14. REPAIRED IAW SRM 53-50-50-2R, PARA 3.C.SDR FDEA201111114880Floorboard · corrodedFLOORBOARD 231 EH HAS INSERTS 7EA CORRODED AND 1 MISSING. FABRICATED REPLACEMENT FLOORBOARD 231 EH IAW DWG SR25-005 REV J.SDR FDEA201111114879Floorboard · crackedFLOORBOARD 221LF HAS 6" CRACK, FABRICATED FLOORBOARD 221LF IAW DWG SRZ 25-005, REV J.SDR FDEA201111104872Floorboard · crackedFLOORBOARD 241SH IS CRACKED ENTIRE WIDTH OF FLOORBOARD ON LOWER SIDE AT FWD CLEVIS ADAPTER 20" WIDE. FLOORBOARD 251SH FABRICATED NEW IAW DWG SRZ25-005 REV J.SDR FDEA201111104867Floorboard · damagedFLOORBOARD 132MG, PUNCTURED ON BACKSIDE AND EDGE DAMAGE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG NR SRZ 25-005, REV J.SDR FDEA201111104866Floorboard · corrodedFLOORBOARD 231KG HAS 22 CORRODED INSERTS AND 2 MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201111104865Floorboard · crackedMAIN DECK ZONE 240 FLOORBOARD 242RJ, FWD SECTION IS BROKEN IN HALF. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ25-005, REV J.SDR FDEA201111104864Floorboard · damagedFLOORBOARD 241ZH PUNCTURED AT 2 LOCATIONS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201111104863Floorboard · crackedFLOORBOARD 241TH IS CRACKED ENTIRE WIDTH ON LOWER SIDE AT FWD. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ25-005, REV J.SDR USAA2011111000011Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL 261DF AT FR20, Y510. REPLACED FLOOR PANEL 261DF IAW MCGILL IRM 9701 REV G.SDR USAA2011112100017Floor Panel · delaminated1S CHECK - 4 AREAS OF DELAMINATION ON FLOOR PANEL 242KF BETWEEN FR42 TO FR47 & BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL 242KF IAW JOB CARD 26C22053014.SDR USAA2011111800036Floor Panel · delaminated1S CHECK - DELAMINATION ON FLOOR PANEL 241GF BETWEEN FR36 TO FR42 & BETWEEN Y765 TO Y1292. REPLACED FLOOR PANEL 241GF IAW JOB CARD 26C24053002.SDR IPXA11570299Floor Panel · delaminatedMAIN CABIN FLOOR PANEL NR 221 XCF DELAMINATED IN CTR OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR FDEA201111094844Floorboard · crackedFLOORBOARD 151VF CRACKED IN HALF AND MULTIPLE CRACKS. FABRICATED REPLACEMENT FLOORBOARD 151 VF IAW DWG SRZ 25-005, REV J.SDR FDEA201111094843Floorboard · damagedFLOORBOARD 151SF HAS EDGE DAMAGE 12" X 3" FABRICATED REPLACEMENT FLOORBOARD 151SF IAW DWG SRZ 25-005, REV J.SDR FDEA201111094842Floorboard · delaminatedFWD PIT FLOORBOARD 132 KG EDGES DELAM 25 SQ IN. FABRICATED REPLACEMENT FLOORBOARD 132 KG IAW DWG SRZ 25-005, REV J.SDR FDEA201111094841Floorboard · tornFLOORBOARD 152PF TORN IN SEVERAL PLACES FABRICATED REPLACEMENT FLOORBOARD 152PF IAW DWG. SRZ25-005.SDR FDEA201111094833Floor Panel · damagedFORWARD CARGO COMPARTMENT FLOOR PANEL NR 131LG FOUND DAMAGED. FLOOR PANEL R & R IAW AMM 53-10-29-4, REV.52. NEW FLOOR PANEL FABRICATED IAW DWG: SRZ -25-005- REV: J, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.SDR FDEA201111094832Floor Panel · damagedFORWARD CARGO COMPARTMENT FLOOR PANEL NR132LG FOUND DAMAGED. FLOOR PANEL R & R IAW AMM 53-10-29-4, REV 52.0. NEW FLOOR PANEL FABRICATED IAW DWG SRZ25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.SDR USAA2011112100019Floor Panel · delaminated1S CHECK - AREA OF DELAMINATION ON FLOOR PANEL 151DF AT FR53, -Y12. REPLACED FLOOR PANEL 151DF IAW A320 SRM 53-02-00 PARA G FIG 209.
Back to JASC 5321