JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201109214003Floor Panel · crackedFLOOR PANEL 251BH HAS 1EA 10" CRACK. FABRICATED REPLACEMENT FLOOR PANEL 251 BH IAW DWG SRZ25-005, REV J. MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201109214002Floor Panel · crackedFLOOR PANEL 232YG HAS 2 EA 9" CRACKS. FABRICATED FLOOR PANEL 232YG IAW DWG SRZ 25-005, REV J, MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201109214001Floorboard · crackedFLOORBOARD HAS 2 EA 6" CRACKS ON BACKSIDE AND 1EA DELAMINATED CORNER FABRICATED REPLACEMENT FLOORBOARD 132MG IAW DWG SRZ-25-005, REV J MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201109214000Floorboard · damagedFLOORBOARD HAS MULTIPLE PUNCTURES ON BACK SIDE AND DELAMINATED CORNER. FABRICATED REPLACEMENT FLOORBOARD 132KG IAW DWG SRZ-25-005 REV J IDENTIFIED. REPLACEMENT FLOORBOARD IAW GMM 7-0-1001. MAJOR REPAIR IAW GMM6-2-100.SDR FDEA201109213988Floorboard · crackedFLOORBOARD 242RG HAS 1EA 12" CRACK. FABRICATED REPLACEMENT FLOORBOARD 242 RG IAW DWG SRZ 25-005, REV J.SDR ASOA201101762Pressure Deck · corrodedCORROSION FOUND AT PRESSURE FLOOR FS 424-559 LBL 36, STR 17. REMOVED COSSOSION IAW SRM 51-21-06. PERFORMED UT THICKNESS INSPECTION IAW MAC NDT INSP PROCEDURE UT-3 MIN. MATERIAL REMAINING IS .071" WITHIN ALLOWABLE LIMITS OF REO 601R-53-41-666.SDR FDEA201109203975Floor Panel · crackedFLOOR PANEL 251QH HAS 1EA 10" CRACK. FABRICATED REPLACEMENT FLOOR PANEL 251QH IAW DWG SRZ 25-005 REV J.SDR FDEA201109203974Floor Panel · crackedFLOOR PANEL 241DF HAS 2EA 10" CRACKS FABRICATED REPLACEMENT FLOOR PANEL 241DF IAW DWG SRZ 25-005, REV J.SDR FDEA201109203972Floor Panel · damagedBULK CGO COMPT 161JF EDGE AND UPPER SKIN GOT IMPACT DAMAGE. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM, IRM 9701 AND DWG 17 A532 79960.SDR ZZDA2011791Floor Panel · corrodedR1 DOOR LWR JAM CUTOUT SILL FWD AFT FLOOR SUPPORT PANELS, CORROSION. ACCOMPLISHED FLOOR SUPPORT PANELS REPLACEMENT PER B717 SRM 51-41-01 AND 53-00-00.SDR UIEA2011092100517Floor Panel · corrodedDURING THE PRESENT C4-CHECK, CORROSION WAS REPORTED ON UPPER DECK LIFT CAR ASSY, PN 747-9202-14 LOWER FLOOR PANEL ASSY SHOWN IN FIG 1. CORROSION AFFECTED LOWER PANEL ASSY PN 747-9262-1 BOTH UPPER AND LOWER SURFACE SHEET SIDES AND AFT EDGES AS SHOWN IN FIG 2. SDR FDEA201109193957Floor Panel · crackedFLOOR PANEL 252VF HAS 3EA. 9" CRACKS FABRICATED REPLACEMENT FLOOR PANEL 252VF IAW DWG 25-005, REV J.SDR FDEA201109193956Floor Panel · crackedFLOOR PANEL 252PH HAS 1EA 12" CRACK FABRICATED REPLACEMENT FLOOR PANEL 252PH IAW DWG 25-005, REV J.SDR FDEA201109193955Floor Panel · crackedFLOOR PANEL 252UH HAS 2EA 12" CRACKS FABRICATED REPLACEMENT FLOOR PANEL 252UH IAW DWG SRZ 25-005, REV J.SDR FDEA201109183951Floor Panel · damagedM/D COMP'T AFT REMOVED 242EK FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70614.SDR FDEA201109183950Floor Panel · damagedM/D COMP'T AFT REMOVED 242ZJ FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70609.SDR FDEA201109183949Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242QJ FLOOR PANEL INSP CHECK, FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG NR 15 B532 70600.SDR FDEA201109183948Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242GF FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 14 B532 70480.SDR FDEA201109183947Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242MF FLOOR PANEL INSPECTION CHECK FOUND UPPER SKIN ADN EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70337.SDR FDEA201109183946Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242RG FLOOR PANEL. INSPECTION CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70620.SDR FDEA201109183945Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242VG FLOOR PANEL, INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 16 B532 70260.SDR FDEA201109183944Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 241TH FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG NR 15 B532 70600.SDR FDEA201109183943Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 241AJ FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70609.SDR FDEA201109183942Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 252UH FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70337.SDR FDEA201109183941Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 252PH FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 16 B532 70260.SDR FDEA201109183940Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 252BF FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 16 B532 70262.SDR FDEA201109183939Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 241GJ FLOOR PANEL AND INSP CHECK. FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70620.SDR FDEA201109183938Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 242SF FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 15 B532 70618.SDR FDEA201109183937Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251PH FLOOR PANEL AND INSP CHECK. FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70276.SDR FDEA201109183936Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 252VF FLOOR PANEL AND INSP CHECK, FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70339.SDR FDEA201109183935Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 252WH FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG NR 17 B532 70278.SDR FDEA201109183934Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251BH FLOOR PANEL AND INSP CHECK, FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70287.SDR FDEA201109183933Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251VF FLOOR PANEL AND INSPECTION CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70339.SDR FDEA201109183932Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251YG FLOOR PANEL AND INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG NR 17 B532 70281.SDR FDEA201109183931Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251WH FLOOR PANEL AND INSPECTED. FOUND UPPER SKIN AND EDGE AREA HAS IMPACT DAMAGE. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW FLOOR PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70278.SDR FDEA201109183930Floor Panel · damagedMAIN DECK COMPARTMENT AFT REMOVED 251UH FLOOR PANEL AND INSPECTED, FOUND UPPER SKIN AND EDGE AREA HAS IMPACT DAMAGE. THE DAMAGED AREA IS OVER ALLOWABLE LIMITS. FABRICATED A NEW FLOOR PANEL REF TO AB6F SRM 53-10-20, IRM 9701 AND DWG 17 B532 70337.SDR USAA2011100600033Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232YF BETWEEN FR32 TO FR35, -Y1292. REPLACED FLOOR PANEL 232YF IAW A320 SRM 53-02-00 FIGURE 209.SDR USAA2011100600032Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252NF BETWEEN FR54 TO FR58, -Y1292. REPLACED FLOOR PANEL 252NF IAW A320 SRM 53-02-00 FIGURE 209.SDR USAA2011100600031Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252EF BETWEEN FR47 TO FR51, -Y1292. REPLACED FLOOR PANEL 252EF IAW A320 SRM 53-02-00 FIGURE 209.SDR USAA2011100600030Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 251AF BETWEEN FR47 TO FR51, BETWEEN Y=0 TO -Y765. REPLACED FLOOR PANEL 251AF IAW A320 SRM 53-02-00 FIGURE 209.SDR USAA2011100600021Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232UF BETWEEN FR28 TO FR32, -Y1292. REPLACED FLOOR PANEL 232UF IAW A320 SRM 53-02-00 FIG 209.SDR USAA2011100300031Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL BETWEEN FR24 TO FR28, -Y254. REPLACED FLOOR PANEL BETWEEN FR24 TO FR28, -Y254 IAW A320 SRM 53-02-00 FIGURE 209.SDR USAA2011092700004Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 232FF BETWEEN FR20 TO FR24, BETWEEN -Y1732 TO -Y1292. REPLACED FLOOR PANEL 232FF BETWEEN FR20 TO FR24, BETWEEN -Y1732 TO -Y1292 IAW A320 SRM 53-12-00, IRM 9701 REV G.SDR FDEA201109173922Floor Panel · damagedM/D COMP'T AFT REMOVED 242BF FLOOR PANEL INSPECTION CHECK FOUND UPPER SKIN AND EDGE AREA IMPACT DAMAGED. THE DAMAGED AREA IS OVER THE ALLOWABLE DAMAGE LIMITS . FABRICATED A NEW PANEL REFER TO AB6F SRM 53-10-20, IRM 9701 AND DWG B532 70478. THE REPAIR CLASSIFSDR FDEA201109173921Floor Panel · damagedM/D COMP'T AFT REMOVED 241QH FLOOR PANEL AND INSPECTION CHECK FOUND UPPER SKIN AND EDGE AREA RECEIVED IMPACT DAMAGED. THE DAMAGED AREA IS NOT WITHIN ALLOWABLE DAMAGE LIMITS. FABRICATED A NEW PANEL REFER TO AB6F SRM 53-10-20, IRM 9701 AND DG 15 B532 70 618. SDR FDEA201109173920Floor Panel · damagedM/D COMP'T AFT REMOVED 231AH FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA IMPACT DAMAGED. THE DAMAGED AREA IS NOT WITHIN THE ALLOWABLE DAMAGE LIMITS. FABRICATED A NEW PANEL REFER TO AB6F SRM 53-10-20, IRM 9701, AND DWG 14 B532 70476. THE REPAIR ESDR FDEA201109173919Floor Panel · damagedM/D COMP'T AFT REMOVED 242UJ FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA GOT IMPACT DAMAGED. THE DAMAGED AREA IS OVER THE ALLOWABLE DAMAGE LIMITS. FABRICATED A NEW PANEL REFER TO AB6F SRM 53-10-20, IRM 9701, AND DWG 15 B532 70604. THE REPAIR EVALUSDR FDEA201109173918Floor Panel · damagedM/D COMPARTMENT AFT REMOVED 232YG FLOOR PANEL INSP CHECK FOUND UPPER SKIN AND EDGE AREA IMPACT DAMAGED. THE DAMAGED AREA IS NOT WITHIN THE ALLOWABLE DAMAGE LIMITS. FABRICATED A NEW PANEL REFER TO AB6F SRM 53-10-20, AND DWG 14 B532 70506. THE REPAIR CLASSIFISDR USAA2011100600035Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 252GF BETWEEN FR51 TO FR54, -Y254. REPLACED FLOOR PANEL 252GF IAW A320 SRM 53-02-00.SDR IPXA20110916001JFloor Panel · damagedMAIN DECK FLOOR PANEL NR12 AT BS 460, RBL 50 IS DAMAGED. R & R FLOOR PANEL REF NR 475585
Back to JASC 5321