JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201108283534Floor Panel · crackedFLOOR PANEL 131ZF HAS 1 EA, 16" CRACK, FABRICATED REPLACEMENT FLOOR PANEL 131ZF IAW DWG SRZ 25-005, REV J.SDR IPXA11568924Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL HAS MISSING INSERTS AND DAMAGE. REPLACED PANEL 231XDF IAW EO B757-5320-9692-G.SDR FDEA201108273527Floor Panel · crackedFLOOR PANEL 132ZF HAS ONE 18'' CRACK. FABRICATED FLOOR PANEL IAW DWG SRZ 25-005 REV. J MAJOR REPAIR IAW GMM 6-2-100SDR FDEA201108273526Floor Panel · crackedMAIN DECK FLOORBOARD 261VF CRACKED ACROSS THE MIDDLE FABRICATED REPLACEMENT FLOOR PANEL 261VF IAW DWG SRZ 25-005, REV. JSDR FDEA201108273525Floor Panel · crackedMAIN DECK FLOOR PANEL 252ZG CRACKED AT 4EA CLEVIS CUTOUTS FABRICATED REPLACEMENT FLOOR PANEL 252ZG IAW DWG SRZ 25-005, REV J.SDR IPXA11568911Deck Plate · corrodedINSPECTION TYPE:C-CK CORROSION FOUND ON AFT DECK PLATE BS 1701 RBL 25. REMOVED CORROSION FROM ORIGINAL .071" IN A 1" X 1" AREA AT BS 1701 RBL 25, WITH A LOSS OF .001" SO REMAINING AREA IS .070" WHICH IS WITHIN LIMITS OF EO B757-5310-38268-C.SDR IPXA11568910Deck Plate · corrodedINSPECTION TYPE:C-CK, CORROSION FOUND ON AFT DECK PLATE BS 1691 RBL 25. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL IN A 1" X 1" AREA AT BS 1691 RBL 25, WITH A MAX LOSS OF .002" IN AREA SO REMAINING AREA IS .069" WHICH IS WITHIN LIMITS OF EO B757-5310-3826SDR IPXA11568909Deck Plate · corrodedINSPECTION TYPE:C-CK, CORROSION FOUND ON AFT DECK PLATE BS 1681 LBL 37. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL IN A 1" X 1" AREA AT BS 1681 LBL 37, WITH A MAX LOSS OF .002" IN AREA SO REMAINING AREA IS .069" WHICH IS WITHIN LIMITS OF EO B757-5310-382SDR IPXA11568908Deck Plate · corrodedINSPECTION TYPE:C-CK, CORROSION FOUND ON AFT DECK PLATE BS 1681 LBL 10. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL IN A 1" X 1" AREA AT BS 1681 LBL 10, WITH A MAX LOSS OF .001" IN AREA SO REMAINING AREA IS .070" WHICH IS WITHIN LIMITS OF EO B757-5310-382SDR IPXA11568907Deck Plate · corrodedINSPECTION TYPE:C-CK CORROSION FOUND ON AFT DECK PLATE 1681 RBL 16. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL 1" X 1" AREA AT BS 1681 RBL 16, WITH A MAX LOSS OF .002" IN AREA SO REMAINING AREA IS .06 9" WHICH IS WITHIN LIMITS OF EO B757-5310-38268-C.SDR IPXA11568906Deck Plate · corrodedINSPECTION TYPE:C-CK, CORROSION FOUND ON AFT DECK PLATE BS 1688 RBL 13. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL IN A 1" X 1" AREA AT BS 1688 RBL 13, WITH A MAX LOSS OF .002" IN AREA SO REMAINING AREA IS .069" WHICH IS WITHIN LIMITS OF EO B757-5310-3826SDR IPXA11568905Deck Plate · corrodedINSPECTION TYPE:C-CK CORROSION FOUND ON AFT DECK PLATE BS 1701 AND 1691 RBL 6. REMOVED CORROSION FROM ORIGINAL .071" MATERIAL IN (2 EA)1"X1" AREAS AT BS 1701 AND 1691 RBL 6, WITH A MAX LOSS OF .002" IN BOTH AREAS SO REMAINING AREA IS .069" WHICH IS WITHIN SDR IPXA11568904Floor Skin · gougedINSP TYPE:C-CK GOUGES FOUND ON AFT DECK PLATE BS 1703 LBL 42. REMOVED GOUGES FROM ORIGINAL .071" MATERIAL IN A 1"X1" AREA AT BS 1703 RBL 42, WITH A MAX LOSS OF .002" IN AREA SO REMAINING AREA IS .06 9" WHICH IS WITHIN LIMITS OF EO B757-5310-38268-C.SDR FDEA201108263505Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 58 TO FRAME 60, X = 37. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED ASDR FDEA201108263504Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 60 TO FRAME 62, X = 57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED ASDR FDEA201108263503Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 54 TO FRAME 54.2, X = 57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED DWG SRZ-25-005 REV J, PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED AS MASDR FDEA201108263502Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 52 TO FRAME 54, X = 57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J, PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED ASSDR FDEA201108263501Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 47 TO FRAME 51, X = -57. LOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J, PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED ASSDR FDEA201108263500Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 51 TO FRAME 54, X = -57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED DWG SRZ-25-005, REV J, PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED AS SDR FDEA201108263499Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 54.0 TO FRAME 54.2, X = -57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J, PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFSDR FDEA201108263498Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, AT FRAME 54.2 TO FRAME 55, X = -57. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPAIR CLASSIFSDR FDEA201108263497Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED, RT AT FRAME 55 TO FRAME 57.1, X = -57. DAMAGED FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. REPASDR FDEA201108263496Floor Panel · damagedMAIN DECK FLOOR PANEL RT AT FRAME 57.1 TO FRAME 58, X = -57 DAMAGED. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J, PAINTED IAW SRM 53-10-20, REV 20. NEW FLOOR PANEL INSTALLED IAW AMM 53-10-25, REV 52. SDR FDEA201108263495Floor Panel · damagedMAIN DECK FLOOR PANEL RT AT FRAME 58 TO FRAME 60, X = -57 DAMAGED. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. FLOOR PANEL PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25, REV 52. RSDR FDEA201108263494Floor Panel · damagedMAIN DECK FLOOR PANEL RT AT FRAME 60 TO FRAME 62, X = -57 DAMAGED. FLOOR PANEL REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J, FLOOR PANEL PAINTED IAW SRM 53-10-20, REV 20 AND INSTALLED IAW AMM 53-10-25 REV 52. REPAIRSDR FDEA201108263493Floor Panel · damagedMAIN DECK FLOOR PANEL, RT AT FRAME 62 TO FRAME 65, X = -57 DAMAGED. REMOVED IAW AMM 53-10-25, REV 52. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. INSTALLED FLOOR PANEL IAW AMM 53-10-25, REV 52. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 11SDR USAA2011091100006Floor Panel · delaminatedC11/SY6 CHECK - DELAMINATION ON FLOOR PANEL 262BF BETWEEN FR 64 - FR 66 AND -Y254 TO -Y1732. REPLACED FLOOR PANEL 262BF BETWEEN FR 64 - FR 66 AND -Y254 TO -Y1732 IAW A319 SRM 53-02-00 AND EA 133771.SDR USAA2011091100005Floor Panel · corrodedC11/SY6 CHECK - CORROSION ON FLOOR PANEL 262FF BETWEEN FR 66 AND FR 68, S23R. REPLACED FLOOR PANEL 262FF BETWEEN FR 66 AND FR 68, S23R IAW A319 SRM 51-72-11.SDR USAA2011091100004Floor Panel · corrodedC11/SY6 CHECK - CORROSION ON FLOOR PANEL 261FF BETWEEN FR 66 AND FR 68, S23L. REPLACED FLOOR PANEL 261FF BETWEEN FR 66 AND FR 68, S23L IAW A319 SRM 51-72-11.SDR USAA2011091100003Floor Panel · corrodedC11/SY6 CHECK - CORROSION ON FLOOR PANEL 221FF BETWEEN FR 20 AND FR 24, S23L. REPLACED FLOOR PANEL 221FF BETWEEN FR 20 AND FR 24, S23L IAW A319 SRM 53-12-12.SDR USAA2011091100002Floor Panel · corrodedC11/SY6 CHECK - CORROSION ON FLOOR PANEL 222FF BETWEEN FR 20 AND FR 24, S23R. REPLACED FLOOR PANEL 222FF BETWEEN FR 20 AND FR 24, S23R IAW A319 AMM 53-12-12.SDR USAA2011091100001Floor Panel · delaminatedC11/SY6 CHECK - DELAMINATION ON FLOOR PANEL 261BF BETWEEN FR 64 - FR 66 AND Y765 - Y1732. REPLACED FLOOR PANEL 261BF BETWEEN FR 64 - FR 66 AND Y765 - Y1732 IAW A319 SRM 53-02-00.SDR FDEA201108263514Floor Panel · brokenFORWARD CARGO FLOOR PANEL 132YF FOUND BROKEN. FLOOR PANEL REMOVED AND REPLACED AS PER AMM 53-10-29 REV.30 FLOOR PANEL FABRICATED AS PER DWG SRZ-25-005 REV J. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REV 112.SDR FDEA201108263513Floor Panel · damagedMAIN DECK CARGO COMPARTMENT BETWEEN FRAME 53 AND FRAME 54 RT OTBD FLOOR PANEL FOUND DAMAGED. FABRICATED FLOOR PANEL PER DWG SRZ 35-005 REV J AND INSTALLED AS PER AMM 53-10-25 REV 30. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 112.SDR FDEA201108263521Floorboard · damagedFLOOR PANEL 132RF HAS 50" OF EDGE DAMAGE. FABRICATED FLOOR PANEL 132RF IAW DWG, SRZ25-005 REV J.SDR DALA1150353249Floor Panel · damagedF/C GALLEY IN FRONT OF CLOSET DOOR FLOOR EXTREMELY SOFT. REMOVED DAMAGED FLOOR PANEL & ROUTED TO COMPOSITE SHOP. TRANSFERRED TO N/R NR 1, INSTALLED TEMP REPAIR. SEE LOG 0375143 FOR WORK ACCOMPLISHED. OK FOR SERVICE.SDR DALA1150263116Floor Panel · delaminated(PANEL RACK) FWD CABIN FLOOR PANEL 232FF IS DELAM/PEELING ON LOWER SURFACE FWD CABIN FLOOR PANEL 232FF FABRICATED NEW ON STAM TRAVELER T11/893912 IAW A319 DWG 3D25-40640. SPLICE PLATE INSTALLED ON WC 2500-6601. DAMAGE AREA IS 3"X3".SDR DALA1150253116Floor Panel · punctured(PANEL RACK) FWD CABIN FLOOR PANEL 232DF HAS SMALL PUNCTURE ON UPPER SURFACE AND A CORRODED INSERT CAUSING LOWER SURFACETO DELAM. FABRICATED NEW ON STAM TRAVELER T11/893914 PER DWG3D25-40640. SPLICE PLATE INSTALLED ON W/C 2500-6601. RETAIN FOR RECORDS.SDR DALA1150243116Floor Panel · delaminated(PANEL RACK) COCK PIT FLOOR PANEL 211EF HAS DELAM AND PEELING UP PER SKIN. COCKPIT FLOOR PANEL 211EF FABRICATED NEW STAM TRAVELER T11/8939 16 IAW A319 DWG 3D25-40640.SDR DALA1150233116Floor Panel · punctured(PANEL RACK) FWD CABIN FL PANEL 231KF HAS 7IN PUNCTURE ON UPPER SURFACE. FWD CABIN FLOOR PANEL 231KF FABRICATED NEW ON STAM TRAVELER T11/893913 IAW A319 DWG 3D25-40640.SDR DALA1150223116Floor Panel · torn(PANEL RACK) AFT CABIN FLOOR PANEL 261PF HAS TORN-OUT AND MISSING INSERT. FABRICATED NEW FLOOR PANEL 261PF ON STAM TRAVELER T11/893911 PER DWG 3D25-40640.SDR DALA1150213116Floor Panel · torn(PANEL RACK) MAIN DECK AFT CABIN FLOOR PANEL 262EF HAS TORN-OUT/MISSING INSERT MAIN DECK AFT CABIN FLOOR PANEL 262EF FABRICATED NEW ON STAM TRAVELER T11/893909 IAW A319 DWG 3D25-40640.SDR DALA1150203116Floor Panel · torn(PANEL RACK) CENTER AFT LAV FLOOR PANEL ON MAIN DECK 261CG HAS 2 EA TORN AREAS ON LOWER SKIN. FABRICATED NEW FLOOR PANEL 261CG ON STAM TRAVELER T11/893908 PER DWG 3D25-40640.SDR FDEA201108263520Floor Panel · damagedFLOOR PANEL 131YF HAS 15" OF EDGE DAMAGE, 5" OF DELAMINATION, 20SQ." OF CORROSION FABRICATED REPLACEMENT PANEL IAW GWG SRZ-25-005 REV J IDENTIFIED REPLACEMENT PANEL IAW GMM 7-0-1001.SDR FDEA201108263516Floor Panel · damagedFLOOR PANEL 131HG HAS 10" OF EDGE DAMAGE, 10EA. PUNCTURES, 3EA. CRACKS FABRICATED REPLACEMENT PANEL 313HG IAW DWG SRZ-25-005 REV. J IDENTIFIED REPACEMENT PANEL IAW GMM 7-0-1001.SDR FDEA201108263515Floor Panel · crackedFLOOR PANEL 131RF IS CRACKED ACROSS PANEL. FABRICATED REPLACEMENT PANEL 131RF IAW DWG SRZ 25-005 REV J.SDR IPXA11569173Floorboard · puncturedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOORBOARD NR 231XFF HAS SCREW PUNCTURE, BALL MAT DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11569171Floorboard · damagedINSPECTION TYPE:C-CHECK, MAIN CARGO FLOORBOARD 251XQF IS DAMAGED. FABRICATE NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1569102Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 231XWF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1569101Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 252XFF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.
Back to JASC 5321