SDR IPXA11566483Floorboard · damagedINSPECTION TYPE:C3, BS 900-1020, RBL 45-65, WL 208, FLOORBOARD BROKEN AND EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566478Floorboard · damagedINSPECTION TYPE:C3, BS-1020-1060, RBL-24-44, WL-208, FLOORBOARD DAMAGED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11566476Floorboard · damagedINSPECTION TYPE:C3, BS 1060-1080, LBL-46-64, WL-208, FLOORBOARD HAS EDGE DAMAGE AND MISSING INSERT. REPLACED FLOORBOARD IAW EO B75705320-9692-G.SDR IPXA11566475Floorboard · damagedINSPECTION TYPE:C3, BS 1056, RBL-45-65, WL-208, FLOORBOARD HAS DAMAGE AND A MISSING INSERT. REPLACED FLOORBOARD IAW EO B75705320-9692-G.SDR IPXA11566472Floorboard · damagedINSPECTION TYPE:C3, BS 900-1020, LBL 0-25, WL-208, FLOORBOARD HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B75705320-9692-G.SDR IPXA11566469Floorboard · damagedINSPECTION TYPE:C3, BS 900-1020 LBL 24-44 WL 208 FLOORBOARD HAS EDGE DAMAGE REPLACED FLOORBOARD IAW EO B75705320-9692-G.SDR IPXA11566458Floorboard · damagedINSPECTION TYPE:C3, BS-1020-1060, RBL-0-24, WL-208, FLOORBOARD DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1566426Floor Panel · damagedINSPEB757-5320-96G.CTION TYPE:C3, BS 1060-1080, LBL 46-64, WL 208, FLOORBOARD HAS EDGE DAMAGE AND MISSING INSERT. FABRICATED REPLACEMENT PANEL IAW EB757-5320-96G.OSDR IPXA1566425Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020, LBL 44-65, WL 208, FLOORBOARD HAS MISSING INSERT AND EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566424Floor Panel · damagedINSPECTION TYPE:C3, BS 1056, RBL 45-65, WL 208, FLOORBOARD HAS EDGE DAMGE AND A MISSING INSERT. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566423Floor Panel · brokenINSPECTION TYPE:C3, BS 900-1020, RBL 45-65, WL 208, FLOORBOARD BROKEN AND EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566414Floor Panel · damagedINSPECTION TYPE:C3, BS 1100-1200, LBL 25-45, WL 208, FLOORBOARD IS DAMAGED AND MISSING INSERT. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566413Floor Panel · damagedINSPECTION TYPE:C3, BS 1100-1200, LBL 0-24, WL 208, FLOORBOARD DAMAGED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1566412Floor Panel · damagedINSPECTION TYPE:C3, BS 1020-1060, RBL 45-64, WL 208, FLOORBOARD DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566411Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020, RBL 01-25, WL208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1566410Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020, RBL 25-45 WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-520-9692-G.SDR IPXA1566401Floorboard · damagedINSPECTION TYPE:C3, BS 900-1020, LBL 0-25, WL 208, FLOORBOARD HAS EDGE DAMAGE FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1566400Floor Panel · damagedINSPECTION TYPE:C3, BS 900-1020. LBL 24-44, WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1566399Floorboard · damagedINSPECTION TYPE:C3, BS-1020-1060, LBL 0-25, WL 208, FLOORBOARD HAS EDGE DAMAGE. FABRICATED REPLACEMENT PANEL IAW EO NR B757-5320-9692-G.SDR DALA1131219875Floor Panel · puncturedPASSENGER CABIN FLOOR PANEL 59-50 HAS PUNCTURE. REMOVED HAT CHANNELS 2EA AT IAW DC-9 SRM 51-30-2 PG 24, 26. CUT OUT DAMAGED AREA IAW DC-9 SRM 53-05 PG 10. FABBED DOUBLER AND FILLER IAW DC-9 SRM 53-05 PG 10. TREATED AND PRIMED DOUBLER AND FILLER IAW DC-9 SRSDR IPXA11566466Floorboard · gougedINSPECTION TYPE:C3, MCD INTERIOR STRUCTURE, WEB HAS GOUGE 5" UP FROM BOTTOM EDGE. FABRICATED NEW FLOORBOARD IAW DWG 65-49309 AND SRM 50-10-02-0G, 51-40-02-0G, 51-40-05-0G.SDR USAA2011050591773Floor Panel · delaminatedPIT - C11/SY6 - DELAMINATION ON FLOOR PANEL 261AG BETWEEN FR64 TO FR66 & BETWEEN Y254 TO -Y254. REPLACED FLOOR PANEL 261AG BETWEEN FR64 TO FR66 & BETWEEN Y254 TO -Y254 IAW MCGILL IRM 9701 REV G.SDR DALA1130689875Floor Panel · corrodedCABIN FLOOR PANEL 27 METAL THRU PLATE 2 EACH FOR LAV WATER LINES HAS CORROSION ON CABIN FLOOR PANEL 27, REMOVED 2EA. LAV WATER LINE DOUBLER IAW DC9/MD-80 SRM 51-70-02 PARA 6 PAGE 11. FABBED 2EA DOUBLER PLATE PER FSI DWG 94RS481265. BONDED 2EA DOUBLER PLATE SDR DALA1130639875Floor Panel · corrodedCOCKPIT FLOOR PANEL 14 HAS SURFACE CORROSION AND SECURING FASTENERS PULLING THRU AND PUNCTURED. REMOVED COCKPIT PANEL 14 PER MM A-53-20-01-201-925A-A PG 1-4 FOUND PANEL TO BE OUT OF LIMITS PER SRM 53-05 PG 9 PAR 3 FABRICATED PANEL PER SRM 53-05 FIG 1. REINSSDR DALA1130609866Floor Panel · crackedMAIN CABIN FLOOR PNL 74 BTM END OF PNL SUPPORT FASTENER HOLE CRACK OUT. CUT OUT DAMAGED HAT CHANNEL IAW DC9 SRM 53-05 FIG 1. FABBED NEW SECTION OF HAT CHANNELS & DOUBLER P/N 2912282 IAW DC-9 SRM 53-05 FIG 1. HFEC INSP IAW NDT SPM 09-10-01. DAMAGE REMOVED, SDR IPXA11566535Floor Panel · delaminatedINSPECTION TYPE:C3, COCKPIT FLOOR PANEL BS 297-333, RBL 10 TO RBL 60 HAS DELAMINATION ON LOWER SURFACE AT POTTED INSERT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11566836Floor Skin · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR UPPER SURFACE AT CAPT'S INBD AFT SEAT TRACK AT 2 PLACES, BS 254-27. (MARKED) REPAIR DOUBLER IAW ATS ER11-02718, AND EO B757-5310-42849-A.SDR IPXA11566835Floor Skin · corrodedINSPECTION TYPE:C3, CORROSION ON COCKPIT FLOOR UPPER SURFACE AT CAPT'S INBD FWD SEAT TRACK AT 3 PLACES, BS244-257. (MARKED) REPAIR DOUBLER IAW ER 11-02718, AND EO B757-5310-42849-A.SDR IPXA1B66284Floor Panel · puncturedFLOOR PUNCTURE AT STA 1640, LBL114. REPAIRED IAW EO B747-5320-42149-A.SDR IPXA1B66283Floor Panel · damagedFLOOR DAMAGE AT STA 2030, LBL 114. REPAIRED IAW EO B747-5320-42130-A.SDR IPXA1B66282Floor Panel · damagedMULTIPLE DAMAGES ON FLOOR PANEL AT STA 1649 LBL 107, 109, 113, 114. REPAIRED IAW EO B747-5320-42128-A.SDR IPXA1B66281Floor Panel · damagedFLOOR PANEL DAMAGE AT STA 550 LBL 59. REPAIRED IAW EO B747-5320-42129-A.SDR IPXA1666275Floor Panel · dentedMAIN DECK FLOOR PANEL 9L OTBD HAS DENT 1.5 INCH DIA AT ST STA 1263 LBL80. REPLACED MAIN DECK FLOOR PANEL IAW EOB767-5320-9693-H.SDR IPXA1666357Floorboard · puncturedINSPECTION TYPE:MOD, FLOORBOARD PUNCTURED AT STA 360, RBL 6. REMOVED, FABRICATED AND INSTALLED NEW FLOORBOARD IAW AMM 25-57-05-4, AMM 25-58-01-4, AMM 53-01-06-4, EO B767-5320-9693H.SDR DALA1130279866Floor Panel · corrodedMAIN CABIN-FLOOR PANEL 35 UPPER SURFACE HAS CORROSION ON EXISTING REPAIR DOUBLER. REMOVED CORROSION IAW SRM 51-10-3. FOUND OUT OF LIMITS. FABED NEW DOUBLER FR0M 0.025 7075T6 IAW SRM 53-01, FIG 2, SHEET 3 AND 53-23-0, FIG 4. TREATED AND PRIMED IAW SRM 51-10-SDR IPXA1166654Floor Panel · delaminatedINSP TYPE:10YR, FLOOR PANEL 242 LT IS DELAMINATED AND CRACKED. FABRICATED NEW FLOOR PANEL 242LT IAW EO A300-5320-40552-A.SDR IPXA11566549Floorboard · damagedINSPECTION TYPE:C1, DAMAGE ON UPPER SURFACE OF MAIN DECK FLOORBOARD 251XRF. FABRICATED REPLACEMENT FLOORBOARD NR 251XRF IAW B757-5320-9692-G.SDR USAA2011050591769Floor Panel · delaminatedPIT - C11/SY6 - DELAMINATION ON FLOOR PANEL 222CF BETWEEN FR12 TO FR16. REPLACED FLOOR PANEL 222CF BETWEEN FR12 TO FR16 IAW MCGILL IRM 9701 REV G.SDR UALA2011042802072Floor Panel · damagedAISLE BETWEEN SEATS 25-26 ON RT SIDE HAS SOFT FLOOR. REPLACED FLOOR PANEL ASSY.SDR DALA1129969875Floor Panel · corrodedCABIN FLOOR PANEL 46 HAS SURFACE CORROSION ALONG ROW OD OTBD FASTENER HOLES. BLENDED CORRODED FASTENER HOLES IAW SRM 51-10-3 PG 46-47 ORIG MAT THICKNESS .020 IAW SRM 53-23-0 MAX MAT LOSS .020 OUT OF LIMITS IAW SRM 53-01. REMOVED IAW SRM 51-30-11 AND 51-30-2.SDR DALA1129959875Floor Skin · dentedCABIN FLOOR PANEL 49 HAS 4 EA DENTS IN UPPER SKIN. DAMAGE IN EXCESS OF 8 INCHES OUT OF LIMITS IAW SRM 53-05. FABRICATED FLOOR PANEL 49 IAW SRM 53-23-0 AND 53-05, REMOVED HAT CHANNELS IAWSRM 53-05 PAINTED AND TREATED FLOOR 49 RE-INSTALLED HAT CHANNELS IAW SRSDR DALA1129949875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL 25-50 HAS CORROSION. REMOVED CORROSION ON FLOOR PANEL 25-50 SKIN, FOUND TO BE OUT OF LIMITS, REMOVED, FABRICATED, AND INSTALLED NEW SKIN IAW AMM DC-9-A-51-21-03-701-929A-A, SRM 53-23-07 P.7, SRM 51-10-4, SRM 51-10-2, SRM 51-10-3 P.SDR DALA1129939875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL 98-50 HAS CORROSION. REMOVED CORROSION IAW AMM DC9-A-51-21-03-701-929A-A ORIGINAL OUT OF LIMITS IAW AMM SRM 53-01 PG:5-8. REMOVED 2 EA HAT CHANNELS IAW SRM 51-30-02, PG 24. RECEIVED MATERIAL IAW SRM 53-23-0. TREATED AND PRIMED SDR DALA1129929875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL 22-50 HAS CORROSION OUT OF LIMITS REF SRM 53-01, PG 8 FIG 1. REMOVED HAT CHANNELS SKIN REF SRM 51-30-2, PG 1-14. FABRICATED SKIN USING 7075T6-.040 BATCH 0001804643 REF SRM 53-23-0, PG 6, FIG 3. TREATED SKIN REF SRM 51-10-3, PG 40SDR USAA2011051091828Floor Panel · brokenCWF - S4 - MISSING COMPOSITE ON FLOOR PANEL 241LF BETWEEN FR42 TO FR47, S23L & BETWEEN Y766 TO Y1292. REPLACED FLOOR PANEL 241LF IAW MCGILL IRM 9701 REV G.SDR IPXA11M66250Floor Panel · delaminatedFLOOR PANEL DELAMINATED FWD OF GALLEY. FABRICATED NEW PANEL IAW MD11-5320-42456-A ON NRC 396932.SDR DALA1129629875Floor Skin · damagedAFT CABIN STA 1159, RBL 15 SUB FLOOR SKIN HAS 2 EA TOOL MARKS. MEASURED AFT CABIN SUB FLOOR ORIG MAT.040" MAT LOSS .015" OUT OF LIMITS IAW SRM 53-01, PG 8, FIG 1, SHT 3. REMOVED DAMAGE AREA IAW SRM 53-01. NO CRACKS NOTED. FABED DOUBLER IAW SRM 53-01. INSTSDR FDEA201104261629Deck Plate · corrodedAFT SHEAR DECK HAS CORROSION - BSTA 1717-1714 AND RBL 22- RBL 26. AFT DECK PLATE BETWEEN STA 1681 AND STA 1720, LBL 60 TO RBL 60, REMOVED AND REPLACED IAW SRM 51-40-02 REV. 102. REPAIR IS CLASSIFIED AS MAJOR.SDR IPXA1166433Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231NJ IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 231NJ IAW EO A300-5320-40552-A, APPENDIX B.SDR IPXA1166432Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231WG IS DELAMINATED AND GOUGED. FABRICATED MAIN CABIN FLOORBOARD NR 231WG IAW EO A300-5320-40552-A, APPENDIX B.
Back to JASC 5321