JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201006252158Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1139; 85 INCHES RT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL STA.1139, 85" RH OF C/L IAW SRZ25-005 REV.H. REMOVED AND INSTALLED FLOORBOARD IAW MM 53- 21-08-2. APPLIED HOT MELT IAW MM 53-21SDR FDEA201006252157Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1039; 85 INCHES RIGHT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL STA.1039, 85" RH OF C/L IAW SRZ25-005 REV. H. INSTALLED NEW FLOORBOARD IAW MM 53-21-08-2. APPLIED HOT MELT IAW MM 53-21-08-2 SDR FDEA201006252149Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 820; 30 INCHES RT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL STA.820 , 30" RT OF C/L IAW SRZ25-005 REV H. REMOVED AND INSTALLED NEW FLOORBOARD IAW MM 53-21-08-2. APPLIED HOT MELT IAW MM 53-21-SDR IPXA10561070Floor Panel · gougedINSPECTION TYPE:C3, FWD CARGO BAY NR 3 FLOOR PANEL IS GOUGED IN 6 AREAS. REPLACED FWD CARGO BAY NR 3 FLOOR PANEL IAW SRM 51-40-08-OG.SDR FDEA201006252148Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 820; 15 INCHES RT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA. 820 IAW SRZ 25-005 REV. H INSTALLED FLOORBOARD IAW MM 53-21-08-2 PG. 2 STEP 3,4 APPLIED HOT MELT IAW DC/MD10-1053-21-08-2 PG.4 STEP SDR FDEA201006252204Floor Panel · puncturedMAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1460, C/L IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005, REV "H".SDR FDEA201006252170Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1461; 85 INCHES RIGHT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1461 IAW DWG SRZ 25-005, REV "H". REMOVAL ACCOMPLISHED IN HANGAR ON N/R N00448.SDR FDEA201006252182Floor Panel · delaminatedCENTER PIT FLOOR PANEL 183 RF IS DELAMINATED. FABRICATED NEW FLOOR BOARD 183 RF IAW DWG SRZ 25-005, REV "H".SDR FDEA201006252169Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1375; 55 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1375, RBL.55 IAW SRZ25-005, REV H, INSTALLED FLOORBOARD IAW MM 53-21-08-2, APPLIED HOT MELT IAW MM 53-21-08-2, PG 4, STEP A4,5. INSTALSDR FDEA201006252166Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1270; 80 INCHES RT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1270, RBL 80 IAW SRZ25-005 REV H, INSTALLED FLOORBOARD IAW MM 53-21-08-2, APPLIED HOT MELT IAW MM 53-21-08-2 PG 4 STEP A4,5. INSTALLSDR FDEA201006252163Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1139; 85 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1139; 85" LT OF C/L IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD IAW AMM 53-21-08-2. APPLIED HOT MELT IAW AMM 53-2SDR FDEA201006252162Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1139 LBL 85 . FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1139 IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOOR PANEL AND APPLIED HOT MELT IAW AMM 53-21-08-02.SDR FDEA201006252156Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1039; 55 INCHES RT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1039, 55" RT OF CTR IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOOR PANEL AND APPLIED HOT MELT IAW AMM 53-21-08-02. INSSDR FDEA201006252155Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 1039; 80 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 1039, 80" LT OF CTR IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOORBOARD AND APPLIED HOT MELT IAW AMM 53-21-08-02.SDR FDEA201006252154Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 920; 80 INCHES LEFT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 920, 80" LT OF CTR IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOOR PANEL AND APPLIED HOT MELT IAW AMM 53-21-08-02. INSTASDR FDEA201006252153Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 780; 60 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 780, 60" LT OF CTR IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOOR PANEL AND APPLIED HOT MELT IAW AMM 53-21-08-02. INSTALLSDR FDEA201006252152Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 800; 78 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 800, 78" LT OF CTR IAW DWG SRZ 25-005, REV "H". REMOVED AND INSTALLED FLOORBOARD AND APPLIED HOT MELT IAW AMM 53-21-08-02.SDR FDEA201006252151Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 820; 78 INCHES LT OF C/L; FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 800, 78" LT OF CTR IAW DWG SRZ 25-005, REV "H". R & R FLOOR PANEL AND APPLIED HOT MELT IN GAPS IAW AMM 53-21-08-02. INSTALLED PLACARDSDR FDEA201006252150Floor Panel · puncturedMAIN CARGO COMPARTMENT STA 820; C/L FLOOR PANEL IS PUNCTURED. FABRICATED NEW MAIN CARGO FLOOR PANEL AT STA 820, BL.0 IAW SRZ25-005 REV H, INSTALLED FLOORBOARD IAW MM 53-21-08-2, APPLIED HOT MELT IAW MM 53-21-08-2, PG 4, STEP A 4,5.SDR IPXA10561045Floor Panel · corrodedINSPECTION TYPE:C3, CONTROL CABIN LOWER FLIGHT DECK FLOOR PANEL HAS CORROSION AT STA 247, LBL 35. REPAIR FLIGHT DECK FLOOR IAW ER NR 10-3255.SDR IPXA10561044Floor Panel · corrodedINSPECTION TYPE:C3, CONTROL CABIN LOWER FLIGHT DECK FLOOR PANEL HAS CORROSION AT STA 288, LBL 30. REPAIR FLIGHT DECK FLOOR IAW ER NR 10-3255.SDR IPXA10561043Floor Panel · corrodedINSPECTION TYPE:C3, CONTROL CABIN LOWER FLIGHT DECK FLOOR PANEL HAS CORROSION AT STA 275, LBL 39. REPAIR FLIGHT DECK FLOOR IAW ERNR 10-3255.SDR IPXA10561042Floor Panel · corrodedINSPECTION TYPE:C3, CONTROL CABIN LOWER FLIGHT DECK FLOOR PANEL HAS CORROSION AT STA 279 LBL 21. REPAIR FLIGHT DECK FLOOR IAW ER 10-3255.SDR IPXA10560902Floor Panel · puncturedINSPECTION TYPE:C3, CONTROL CABIN UPPER FLIGHT DECK FLOOR PANEL PUNCTURED STA 325, LBL 53. R & R CONTROL CABIN UPPER FLIGHT DECK FLOOR PANEL AT STA 325. LBL 53 IAW EO B757-5320-9692-G.SDR IPXA10160862Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242TN IS CRACKED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD 242TN IAW EO A300-5320-38221-B.SDR IPXA10161062Floorboard · puncturedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD PANEL NR 151SF HAS A PUNCTURE. FABRICATED AFT CARGO FLOORBOARD NR 151SF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10161060Floorboard · delaminatedINSPECTION TYPE:10YR, AFT CARGO COMP PANEL NR 151NG HAS DELAMINATION FABRICATED AFT CARGO FLOORBOARD NR 151NG IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10161057Floorboard · puncturedINSPECTION TYPE:10YR, FWD PIT FLOORBOARD NR 132QT HAS PUNCTURES. FABRICATED FWD CARGO FLOORBOARD NR 132QT IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10161056Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 242YK IS CRACKED IN (2) PIECES. FABRICATED MAIN CABIN FLOORBOARD NR 242YK IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160860Floorboard · puncturedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD 151KG HAS A PUNCTURE ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD 151KG IAW EO A300-5320-38221-B.SDR IPXA10160855Floorboard · crackedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD 151UF HAS A CRACK. ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD 151UF IAW EO A300-5320-38221-B.SDR IPXA10160853Floorboard · puncturedINSPECTION TYPE:10YR AFT CARGO FLOORBOARD PANEL 151LG HAS PUNCTURES ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD 151LG IAW EO A300-5320-38221-B.SDR IPXA10160850Floorboard · puncturedINSPECTION TYPE:10YR, FWD PIT FLOORBOARD PANEL 131BH HAS A PUNCTURE ACCOMPLISHED REPAIR ON FWD PIT FLOOR BOARD 131BH IAW EO A300-5320-38221-B.SDR IPXA10160849Floorboard · delaminatedINSPECTION TYPE:10YR, FWD PIT FLOORBOARD PANEL 132PG DELAMINATED AT CORNER (FWD) ACCOMPLISHED REPAIR ON FWD PIT FLOORBOARD 132PG IAW EO A300-5320-38221-B.SDR IPXA10160818Floorboard · puncturedINSPECTION TYPE:10YR, FWD CARGO FLOORBOARD 131AH IS PUNCTURED. ACCOMPLISHED REPAIR ON FWD CARGO FLOORBOARD 131AH IAW EO A300-5320-38221-B.SDR IPXA10160817Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 252PM DELAMINATED ACCOMPLISHED REPAIR ON FLOORBOARD 252PM IAW EO A300-5320-38221-B.SDR IPXA10160787Floorboard · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPARTMENT FLOORBOARD NR152VF IS PUNCTURED. ACCOMPLISHED REPAIR ON AFT CARGO COMPARTMENT FLOORBOARD NR 152VF IAW EO A300-5320-38221-B.SDR IPXA10160777Floorboard · puncturedINSPECTION TYPE:10YR, FWD CARGO FLOORBOARD PANEL NR 132FE HAS A PUNCTURE. ACCOMPLISHED REPAIR ON FWD CARGO FLOORBOARD NR 132FE IAW EO A300-5320-38221-B.SDR IPXA10660976Floor Panel · damagedINSPECTION TYPE:C, STA 1429 TO 1540 LBL 55 TO LBL 80 FLOOR PANEL FOUND 3 DAMAGED AND 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND REINSTALLED IAW AMM 53-01-01.SDR 2010FA0000619Plate · corrodedCORROSION ON CABIN FLOOR PANEL CONNECTING PLATE FR68 RBL20. NO CORROSION REMOVAL LIMITS FOUND IN SRM. R & R PLATE IAW AMM 20-21-11. PLATE IS LISTED AS PRIMARY STRUCTURE BY THE MFG.SDR 2010FA0000618Plate · corrodedCORROSION ON CABIN FLOOR PANEL CONNECTING PLATE FR66 LBL1. NO CORROSION REMOVAL LIMITS FOUND IN SRM. R & R PLATE IAW AMM 20-21-11. PLATE IS LISTED AS PRIMARY STRUCTURE BY THE MFG.SDR DALA1014290995Floor Panel · crackedDURING HMV, AT MAIN CABIN FLOOR PANEL NR 886C RT SIDE OF PANEL, CLOSE OUT PANEL STRIP BROKEN, REMOVED BROKEN STRIP, FOUND SUPPORT CRACKED IN 3EA PLACES. REMOVED CRACKED CLOSE OUT STRIP, REMOVED CRACKED SUPPORT, REPLACED EACH, FABBED STRIP (.025-7075T6), SUPPOSDR DALA1013833268Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR PANEL 222FF. REPLACED IAW WORK CARD 2500-6617.SDR DALA1013823268Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR PANEL 221FF. REPLACED IAW WORK CARD 2500-6617.SDR IPXA0560647Floor Panel · damagedFLOOR PANEL NR STA 8 AFT HAS DAMAGE CORNER MFG NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA10161050Floor Panel · damagedINSPECTION TYPE:10YR, MAIN CARGO FLOOR PANEL 222DG CORE MISSING AT EDGE OF PANEL. FABRICATED NEW MAIN CARGO FLOOR PANEL 222DG IAW EO A300-5320-16407-D APPENDIX A/B.SDR IPXA10160946Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL NR 231KJ IS DELAMINATED AND HAS 1 MISSING INSERT. FABRICATED MAIN CABIN FLOORBOARD NR 231KJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160945Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOOR PANEL NR 241 RT IS CRACKED AT CTR CUTOUT FOR FITTING. FABRICATED MAIN CABIN FLOORBOARD NR 241 RT IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160944Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL 231HG HAS PAINT EROSION AND DELAMINATION. FABRICATED MAIN CABIN FLOORBOARD NR 231HG IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160943Floorboard · crackedINSPECTION TYPE:10YR, MAIN CARGO FLOORBOARD NR 241 LT IS CRACKED FABRICATED FLOORBOARD NR 241LT IAW EO A300-5320-16407-D, APPENDIX B.
Back to JASC 5321