JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201003010558Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 187 DF HAS DELAMINATED DENTS. FABRICATED NEW FLOOR PANEL 187 DF IAW DWG SRZ 25-005, REV "H" AND SRZ 25-011, REV "C".SDR FDEA201003010557Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 187 FF HAS DELAMINATED DENTS AND PUNCTURED. FABRICATED NEW FLOOR PANEL 187 FF IAW DWG SRZ 25-005, REV "H" AND SRZ 25-011, REV "C".SDR FDEA201003010556Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 187 JF HAS DELAMINATED DENTS. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005, REV "H" AND SRZ 25-011, REV "C".SDR FDEA201003010555Floor Panel · puncturedAFT CARGO COMPARTMENT FLOOR PANEL 187 HF IS PUNCTURED. FABRICATED NEW AFT CARGO COMPARTMENT FLOOR PANEL NR187 HF IAW DWG SRZ 25- 005, REV "H" AND DWG SRZ 25-011, REV "C".SDR FDEA201003010547Floor Panel · delaminatedCTR CARGO COMPARTMENT FLOOR PANEL 183 HF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005, REV "H".SDR IPXA10158689Floor Panel · damagedMCD FLOOR DAMAGED AT POS 11 RT. REPAIRED FLOOR PER EO-A300-5320-16407-D.SDR IPXA10558688Floor Panel · damagedMCD FLOOR PANEL POS 3 DAMAGED. REPAIRED PER EO A300-5320-16407-D.SDR DALA104479872Floor Panel · corrodedDURING H-CHECK FOUND FLOOR PANEL NR 22 IS CORRODED. INSTALLED NEW FLOOR PANEL AND 2 HAT CHANNELS .SDR DALA104469872Floor Panel · corrodedDURING H-CHECK FOUND FLOOR PANEL NR 99 IS CORRODED. INSTALLED NEW FLOOR PANEL AND HAT CHANNEL.SDR DALA104449872Floor Panel · corrodedDURING H-CHECK FOUND FLOOR PANEL NR 20 CORRODED. INSTALLED NEW FLOOR PANEL, IAW SRM 53-01 & 51-10-4.SDR IPXA10558686Floor Panel · damagedDAMAGED FLOOR PANEL STA 413 LBL 19 POSITION 1L. REPAIRED DAMAGED PANEL PER SRM 53-00-50-2R PARA 3 D.SDR IPXA10658764Floor Panel · puncturedINSP TYPE:C- MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA1480 TO 1598 L11 TO R11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658762Floor Panel · puncturedINSP TYPE:C -MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 412 TO 540 L33 TO L55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658761Floor Panel · puncturedINSPECTION TYPE:C- MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 833 TO 930 L11 TO R11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658760Floor Panel · puncturedINSPECTION TYPE:C - MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 731 TO 833 L11 TO R11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658759Floor Panel · puncturedINSP TYPE:C -MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 879 TO 933 L77 TO L88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658758Floor Panel · puncturedINSP TYPE:C -MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 1207 TO 1344 L33 TO L55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658757Floor Panel · puncturedINSPECTION TYPE:C- MCD FLOOR PANEL, FOUND SEVERAL PUNCTURED HOLES AT STA 654+22 TO 690 R11 TO R33. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658756Floor Panel · puncturedINSP TYPE:C - MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 1197+22 TO 1207 R11 TO R33. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM53-01-01.SDR IPXA10658755Floor Panel · puncturedINSP TYPE:C -MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 1344 TO 1480 L33 TO L55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658754Floor Panel · puncturedINSPECTION TYPE:C- MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA 654+22 TO 690 R33 TO R55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658753Floor Panel · puncturedINSPECTION TYPE:C -MCD FLOOR PANEL FOUND SEVERAL PUCNTURED HOLES AT STA 690 TO 764 L77 TO L88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658752Floor Panel · puncturedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SEVERAL PUNCTURED HOLES AT STA731-833 R33 TO R55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658751Floor Panel · puncturedINSPECTION TYPE:C- MCD FLOOR PANEL, FOUND SEVERAL PUNCTURED HOLES AT STA 580 TO 654+22 R77 TO R88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658750Floor Panel · puncturedINSP TYPE:C- MCD FLOOR PANEL, FOUND SEVERAL PUNCTURED HOLES AT STA 654+22 TO 696 R77 TO R88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10658749Floor Panel · puncturedINSP TYPE:C -MCD FLOOR PANEL, FOUND SEVERAL PUNCTURED HOLES AT STA 412 TO 540 L11 TO R11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR USAA2010022690459Floor Panel · delaminatedPIT - C11 - MAJOR REPAIR - FLOOR PANEL 2691F HAS AREAS OF DELAMINATION. REPLACED FLOOR PANEL 2691F.SDR IPXA11165542Floor Panel · delaminatedINSPECTION TYPE:10YR, COMPT FLOOR PANEL 262SF IS PUNCTURED AT LOWER SURFACE. REPAIRED PANEL 262SF REF EO A300-5320-38221-B .SDR Q2S2010F00040Pressure Panel · crackedWS NR 0437, WC NR 53-842-01-01. LT BODY LANDING GEAR WHEEL WELL AT ABOUT STA 1480 ABOVE ANTI-SKID VALVE MODULE FOUND PRESSURE DECK WEB CRACKED. REPAIR CARRIED OUT IAW EN NR 1011-10, FORM 8100-9, DATED 22 MARCH 2010 ISSUED FOR THE REPAIRED.SDR FDEA201002250527Floor Panel · damagedMAIN CABIN FLOOR PANEL 232VF I S BROKEN FABRICATED NEW FLOORBOARD 232 VF IAW DWG SRZ 25-005, REV "H".SDR IPXA10158809Floor Panel · damagedINSPECTION TYPE:5 YR, AFT BULK CARGO LT FLOOR PANEL 161 HF REQUIRES REPLACEMENT IAW EO A300-5100-35883-A. FABBED FLOOR PANEL IAW EO A300-5320-16407-D, APPX. DSDR IPXA10158808Floor Panel · damagedINSPECTION TYPE:5 YR, AFT BULK CARGO RT FLOOR PANEL 162HF REQUIRES REPLACEMENT IAW EO NR A300-5100-35883-A, APPX.B. FABBED FLOOR PANEL IAE EO A300-5320-16407-D, APPX D.SDR IPXA10158807Floor Panel · damagedINSPECTION TYPE:5YR, AFT BULK CARGO CTR FLOOR PANEL 161JF REQUIRES REPLACEMENT IAW EO A300-5100-35883-A APPX B. FABBED FLOOR PANEL IAW EO A300-5320-16407-D, APPX.DSDR IPXA10658763Floor Panel · damagedINSP TYPE:C -MCD POS 11R FLOOR DAMAGE 28.5 INCHES, RT BS LINE 79 INCHES FROM FWD PANEL. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR FDEA201002250528Floorboard · damagedMAIN CABIN FLOORBOARD BETWEEN FRAMES 55 AND 57 BROKEN. FABRICATED NEW FLOORBOARD 252 BF IAW DWG SRZ 25-005, REV "H".SDR FDEA201002250526Floorboard · puncturedMAIN CABIN FLOORBOARD PUNCTURED BETWEEN FRAMES 22 AND 26. FABRICATED NEW FLOORBOARD 231 VF IAW DWG SRZ 25-005, REV "H".SDR 22AA201000065Roller Tray · corrodedDURING "C" CHECK, CTR CARGO COMPARTMENT LT OTBD CARGO ROLLER TRAY FOUND CORRODED AFTER CARGO SIDE GUIDE RAIL REMOVED TO FACILITATE FOR STRUCTURE REPAIR AT STA 1697 TO STA 1781. NON-ROUTINE NR 0450, CTR CARGO COMPARTMENT LT OTBD CARGO ROLLER TRAY REPAIR CARRIESDR FDEA201002240503Floor Panel · damagedMAIN CABIN FLOOR PANEL IS CRACKED IN HALF (242 RJ). FABRICATED NEW FLOOR PANEL 242 RJ IAW FEDEX DWG SRZ 25-005, REV "H".SDR F3LA2010030900361Floor Panel · delaminatedDURING C4 S1 C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOOR PANEL 151AH DELAMINATED. MX FABRICATED REPLACEMENT PANEL IAW AIM 9701.SDR FDEA201002220488Floorboard · brokenMAIN CABIN CARGO COMPARTMENT FLOORBOARD IS BROKEN FROM FRAME 54.2 - FRAME 55; LBL 55 - LBL 72. FABRICATED NEW MAIN CABIN FLOORBOARD PANEL FROM FRAME 54.2 TO FRAME 55; LBL 55 TO LBL 72 IAW DWG SRZ 25-005, REV "H".SDR FDEA201002220487Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD NR 241 GF IS CRACKED IN HALF. FABRICATED NEW MAIN CABIN FLOOR PANEL NR 241 GF IAW DWG SRZ 25-005, REV "H".SDR FDEA201002220486Floorboard · brokenMAIN CABIN FLOORBOARD IS BROKEN BETWEEN FRAME 62 AND FRAME 65. FABRICATED NEW MAIN CABIN FLOORBOARD BETWEEN FRAME 62 & 65 IAW DWG SRZ 25- 005, REV "H".SDR FDEA201002220485Floorboard · brokenMAIN CABIN CARGO COMPARTMENT FLOORBOARD HAS A BROKEN EDGE AT FRAME 68; LBL 50. FABRICATED NEW MAIN CABIN FLOORBOARD AT FRAME 68; LBL 50 IAW DWG SRZ 25-005, REV "H".SDR FDEA201002220484Floor Panel · crackedMAIN CABIN FLOOR PANEL IS CRACKED AT FRAME 74; LBL 65 - LBL 82. FABRICATED NEW MAIN CABIN FLOOR PANEL AT FRAME 74; LBL 65 TO LBL 82 IAW DWG SRZ 25-005, REV "H".SDR FDEA201002220483Floorboard · brokenMAIN CARGO COMPARTMENT FLOOR BOARD 242 LK IS BROKEN FROM FRAME 53 - FRAME 54; RBL 76. FABRICATED NEW MAIN CABIN FLOORBOARD AT FRAME 53-54; RBL 76 IAW DWG SRZ 25- 005, REV "H".SDR IPXA10558614Floor Panel · damagedFLOOR PANEL PN 143N5457-60, DAMAGED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10558613Floor Panel · damagedFLOOR PANEL PN 143N5457-3 DAMAGED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10558612Floor Panel · damagedFLOOR PANEL PN 143N5457-5, DAMAGED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10558611Floor Panel · damagedFLOOR PANEL PN 134N5457-5, DAMAGED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10558610Floor Panel · damagedFLOOR PANEL PN 143N5457-38, DAMAGED. REPAIRED IAW EO B757-5320-9692-G.
Back to JASC 5321