JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 08FDEA03830Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 60 AND FRAME 62, RBL 18 AND RBL 37. FABBED A NEW PANEL IAW DWG SRZ 25-005, REV "G". PART MARKED IAW GMM 7- 0-1000.SDR 08FDEA03829Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD 252 NH HAS A TORN CORNER BETWEEN FRAME 58 AND FRAME 60; RBL 0 AND RBL 18. FABBED A NEW PANEL IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7-0-1000.SDR 08FDEA03828Floorboard · tornMAIN CABIN FLOOR BOARD IS TORN BETWEEN FRAME 58 AND FRAME 60, RBL 18 AND RBL 37. FABRICATED A NEW PANEL IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7-0-1000.SDR 08FDEA03827Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOOR BOARD 252 GF IS TORN BETWEEN FRAME 57.1 AND FRAME 58, RBL 18 AND RBL 37. FABRICATED A NEW PANEL IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7- 0-1000.SDR 08FDEA03822Floor Panel · contaminatedMAIN WHEEL WELL FLOOR PANEL 147 AF IS DELAMINATED AND SOAKED WITH HYDRAULIC FLUID. FABRICATED A NEW PANEL IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7- 0-1000.SDR 08FDEA03823Floor Panel · delaminatedBULK CARGO PIT FLOOR PANEL 161 GF HAS NUMEROUS AREAS OF DELAMINATION AND DENTS. FABBED NEW FLOOR PANEL IAW DWG SRZ 25-005; REV "G". MATERIAL ID A402H35039-003 IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7-0-1000.SDR 08FDEA03839Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 60 AND FRAME 62, RBL 18 AND RBL 37. 242 QJ FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03838Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 37 AND FRAME 38.2; RBL 17 AND RBL 34. NR 242 MF FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03837Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 34 AND FRAME 37; RBL 17 AND RBL 37. FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03836Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 34 AND FRAME 37; RBL 17 AND RBL 37. NR 242 GF FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03835Floorboard · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 40 AND FRAME 43; LBL 57 AND LBL 77. NR 241 TH FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03834Floorboard · damagedMAIN DECK CARGO COMPARTMENT FLOORBOARD IS TORN BETWEEN FRAME 43 AND FRAME 47; LBL 57 AND LBL 77. NR 241 WH FABRICATED FLOORBOARD IAW FEDEX DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03833Floorboard · crackedMAIN DECK CARGO COMPARTMENT FLOORBOARD IS CRACKED BETWEEN FRAME 77 AND FRAME 88; RBL 30 AND RBL 45. FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03832Floorboard · damagedMAIN DECK CARGO COMPARTMENT FLOORBOARD 262 AH IS TORN BETWEEN FRAME 77 AND FRAME 80, RBL 57 AND RBL 70. FABRICATED FLOORBOARD IAW DWG SRZ 25-005; REV "G". PART MARKED PANEL IAW GMM 7-0-1000.SDR 08FDEA03826Floor Panel · damagedAVIONICS COMPARTMENT FLOOR PANEL 122 JF HAS EDGE DAMAGE. FABBED A NEW PANEL IAW PANEL IAW DWG SRZ 25-005 "G". PART MARKED IAW GMM 7-0-1001.SDR 08FDEA03825Floor Panel · damagedAVIONICS COMPARTMENT FLOOR PANEL 121 JF HAS EDGE DAMAGE. FABBED A NEW PANEL IAW DWG SRZ 25-005; REV "G".SDR 08FDEA03824Floor Panel · damagedFWD LOWER CARGO COMPARTMENT FLOOR PANEL 132 MG IS BROKEN AND PUNCTURED. FABBED NEW PANEL 132 MG IAW DWG SRZ 25-005; REV "G". PART MARKED IAW GMM 7-0-1000.SDR 08FDEA03781Floor Panel · crackedMAIN CABIN FLOOR PANEL CF AT FRAME C 11 A, LOWER SURFACE IS CRACKED. REPAIRED AS REQUIRED IAW ARM 53-10-20; FIG 202.SDR F3LA200800604Floor Panel · corrodedREF: NON ROUTINE C050752. DURING C3 C-CHECK, INSPECTION FOUND (1) MOUNT BUSHING CORRODED ON FLOOR PANEL 261DE. MAINTENANCE REMOVED AND REPLACED MOUNT BUSHING ON C-CHECK CARD NR C5341032. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (KSDR FELA200800597Floor Panel · corrodedREFERENCE NON ROUTINE C050515. DURING C3 C-CHECK INSPECTION NOTED FLOOR PANEL 261FF HAS CORROSION ON LOWER SURFACE. MX R&R FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12 PB 401. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUNDSDR F3LA200800596Floor Panel · puncturedREFERENCE NON ROUTINE C050458. DURING C3 C-CHECK INSPECTION NOTED TRANSITION PANEL 131CF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASSDR F3LA200800595Floor Panel · puncturedREFERENCE NON ROUTINE C050457. DURING C3 C-CHECK INSPECTION NOTED TRANSITION PANEL 131EG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASSDR F3LA200800594Floor Panel · puncturedREFERENCE NON ROUTINE C050375. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL 161CF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800593Floor Panel · puncturedREFERENCE NON ROUTINE C050374. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL 161BF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800592Floor Panel · puncturedREFERENCE NON ROUTINE C050372. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51FF WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800591Floor Panel · puncturedREFERENCE NON ROUTINE C050370. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51UG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800590Floor Panel · puncturedREFERENCE NON ROUTINE C050368. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I51TG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800589Floor Panel · puncturedREFERENCE NON ROUTINE C050366. DURING C3 C-CHECK, INSPECTION NOTED TRANSITION PANEL I52UG WAS PUNCTURED. MX REPAIRED CARGO COMPARTMENT TRANSITION PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800598Floor Panel · corrodedREFERENCE NON ROUTINE C050516. DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 262FF HAS CORROSION ON LOWER SURFACE. MX R&R FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12 PB 401. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUNSDR ASAA0873505Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL BS 727 D TO 767 + 5 CORRODED. REPLACED WITH MADE REPAIR PART IAW B737 700 SRM 53 60 53, FOUND BEYOND LIMIT IAW B737 700 SRM 53 60 53 AND EA 2550 01425.SDR ASAA0873497Floor Panel · corrodedAFT CARGO PIT FLOORBOARD STA 767 887 HAS CORROSION WOUND EDGE ORIGINAL PANEL WAS BEYOND ALLOWABLE LIMITS IAW ASA EA 2550 01425. FLOOR PANEL REPLACED WITH REPAIR PART IAW B737 700 SRM 51 40 05 AND 51 40 06 AND 51 40 08.SDR ASAA0873496Floor Panel · dentedFWD CARGO PIT FLOOR PANEL FOUND DENTED AT DIFFERENT LOCATIONS BS 495 TO 500D. FLOOR PANEL REPLACED AT BS 495 500D IN FWD CARGO PIT IAW B737 700 SRM 53 30 53 AND 51 40 05.SDR F3LA200800588Floor Panel · corrodedREFERENCE NON ROUTINE CO50125. DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 261PF HAS A CORRODED INSERT ON THE LT HAND SIDE AND DELAMINATION IN THE SAME AREA. MX REPAIRED PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9-53R-305SDR F3LA200800580Floor Panel · damagedREFERENCE NON ROUTINE C049995. DURING C3 C-CHECK INSPECTION NOTED THE FORWARD OUTBOARD CORNER WAS DAMAGED ON FLOOR PANEL 242LF. MX REPAIRED DAMAGE TO PANEL 242LF IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9-53R-30577. UPON COMPLETIOSDR UPS08153223Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO FLOOR BOARD PANEL 252WJ HAS A FIELD REPAIR. REPAIRED MAIN CARGO FLOOR PANEL 252WJ REF SRM 53-10-20 TABLE 201 PARA 8A.SDR 08FDEA03554Floor Panel · damagedMAIN CABIN FLOORBOARD 241 BF HAS DAMAGE ON THE FWD CORNER. FABRICATED NEW FLOOR PANEL 241BF, POTTED EDGES, COMPLETED CURE AND LIGHTLY SANDED EDGE POTTING. INSTALLED INSERTS, APPLIED NON-SKID AND PART MARKED THE PANEL IAW DWG SRZ 25-005; REV "G".SDR 08FDEA03553Floor Panel · damagedMAIN CABIN FLOORBOARD 241 DF IS DAMAGED ON THE UPPER SURFACE. FABRICATED NEW FLOOR PANEL 241DF, POTTED EDGES, COMPLETED CURE AND LIGHTLY SANDED EDGE POTTING, INSTALLED INSERTS. APPLIED NON-SKID AND PART PARKED THE PANEL IAW DWG SRZ 25-005; REV "G".SDR F3LA200800578Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED THE FORWARD PIT PANEL 132EG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURED DAMAGE TO FLOOR PANEL IN ACCORDANCE WITH A319 SRM 53-02-00, FIGURE 204.SDR UPS08153238Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO FLOOR PNL 251XJ AFT HAS FIELD REPAIRS. REPAIRED MAIN CARGO FLOOR PNL 251XJ REF A300-600 SRM 51-10-20 TABLE 201 PARA 8A.SDR UPS08153237Floor Panel · damagedINSPECTION TYPE:1C MAIN CARGO FLOOR PNL 252SJ HAS FIELD REPAIRS. REPAIRED MAIN CARGO FLOOR PNL 252SJ REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153222Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO FLOOR PANEL 251MJ FWD HAS FIELD REPAIR. REPAIRED MAIN CARGO FLOOR PANEL 251MJ REF SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153221Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO FLOOR PANEL 251SJ HAS FIELD REPAIR. REPAIRED MAIN CARGO FLOOR PANEL 251SJ REF SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153220Floor Panel · damagedINSPECTION TYPE:1C MAIN CARGO FLOOR PANEL 252OJ HAS A FIELD REPAIR. REPAIRED MAIN CARGO FLOOR PANEL 252OJ REF SRM 53-10-20 TABLE 201 PARA 8A.SDR F3LA200800576Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 161BF WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 161BF IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800575Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 162CF WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 162CF IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800574Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 151BE WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 151BE IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800573Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 151UG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 151UG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. SDR F3LA200800572Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152WG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152WG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. SDR F3LA200800571Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152XG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152XG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. SDR F3LA200800570Floor Panel · puncturedDURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152TG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152TG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.
Back to JASC 5321