Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR L1GA200000376Floor Panel · crackedVARIOUS CRACKS AND GOUGES IN 114 INCH X 10 INCH AREA ON FLOOR PANEL NR 10. FABBED AND INSTALLED NEW SKIN AND HAT CHANNEL SPLICES.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000515Web · crackedCRACK IN FLOOR WEB STATION 160 RBL 54 FLOOR WEB. FABBED NEW WEB.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000332Floor Panel · corrodedCORROSION FLOOR PANEL NR 14. FABRICATED AND INSTALLED PANEL.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000358Floor Panel · crackedCRACKED FLOOR PANEL SKIN NR 77. FABBED AND REPLACED SKIN.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000356Floor Panel · corroded200 INCHES OF CORROSION FLOOR PANEL 21. FABRICATED NEW SKIN.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000355Floor Panel · corrodedA 8 INCH AREA OF CORROSION. FABRICATED AND INSTALLED FILLERS AND DOUBLERS.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000348Floor Panel · crackedCRACKS ON FLOOR BOARD CHANNELS. FABBED NEW HAT CHANNELS AND SKIN.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000347Floor Panel · crackedCRACKS ON FLOOR PANEL 48 FS 522 TO 579 BETWEEN LBL 24 AND BL 0. REPLACED CRACKED CHANNELS.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000459Floor Panel · corrodedVARIOUS CRACKS AND CORROSION IN 81 X 24 INCHES AREA FLOOR PANEL 29 FS 237 TO 318 BL 0 TO RBL 24. FABBED NEW PANEL.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000458Floor Panel · corrodedCORROSION AND CHAFING STATION 163 - 200 RBL 48 RBL 54 FLOOR PANEL 20. FABBED NEW SKIN AND INSTALLED 2 NEW HAT CHANNELS.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000457Floorboard · corrodedLOCALIZED CORROSION 99 X 10 INCHES RT FLOORBOARD PANEL 61. REMOVED CORROSION AND INSTALLED DOUBLER.Nov 14, 2000 · N12510 · Doug DC932SDR L1GA200000439Floor Panel · corrodedTWENTY SQ INCHES OF CORROSION FLOOR PNL 47. FABBED FILLERS AND DOUBLERS.Nov 14, 2000 · N12510 · Doug DC932SDR AT0000503Floor Panel · corrodedDURING A SCHEDULED INSPECTION, FOUND FLOOR PANEL CORRODED AT BS 220 RBL 50. INSTALLED FLOOR PANEL REPAIR IAW DC9 SRM 53-05.Nov 9, 2000 · N831AT · Doug DC932SDR 00FDEA00774Plate · corrodedCABIN - CORROSION ON FLOOR PANEL PLATE AT BS 420, LBL 35 TO 75. *S/D* BLENDED OUT PER SRM 51-21-01 VOL II. REMOVED AND REPLACED PER SRM 51-31-01 VOL II.Nov 9, 2000 · N305FE · Doug DC1030FSDR RRXA003677Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UNDER SIDE OF TOP FLANGE OF LOOR SUPPORT ANGLE AT STA Y=1726 FROM RBL10 TO LBL10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8S RM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.Nov 8, 2000 · N603AL · Doug DC873FSDR AT0100036Floorboard · corrodedFOUND FORWARD ENTRY FLOORBOARD 4691 CORRODED BEYOND LIMITS. REPLACED FLOORBOARD SKIN IAW DC9 SRM 51-10-02, 51-30-02, AND 51-20-10.Nov 7, 2000 · N839AT · Doug DC932SDR AT0100035Floorboard · corrodedFOUND FLOORBOARD 4695 CORRODED BEYOND LIMITS. REPLACED FLOORBOARD SKIN IAW DC9 SRM 51-10-02, 51-10-03, 51-10-04, 51-30-02, AND 53-20-03.Nov 7, 2000 · N839AT · Doug DC932SDR AT0100034Floorboard · corrodedFOUND COCKPIT CENTER FLOORPANEL CORRODED BEYOND LIMITS. REPLACED FLOORBOARD SKIN IAW DC9 SRM 51-30-02 AND 51-30-01.Nov 7, 2000 · N839AT · Doug DC932SDR RRXA003675Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE R/H SIDE AT STA 200 AND 220 BL 65R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND Nov 6, 2000 · N603AL · Doug DC873FSDR RRXA003622Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE IN THE MAIN CABIN R/H SIDE BETWEEN STA'S 834.5 AND 857 AND L65R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 Nov 6, 2000 · N603AL · Doug DC873FSDR RRXA003621Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE IN THE MAIN CABIN R/H SIDE BETWEEN STA'S 822 AND 834.5 AND L65R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 Nov 6, 2000 · N603AL · Doug DC873FSDR RRXA003620Angle · corrodedDURING A MAINTENANC EVISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE IN THE MAIN CABIN R/H SIDE BETWEEN STA'S 798 AND 822 AND L65R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRNov 6, 2000 · N603AL · Doug DC873FSDR RRXA003619Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE IN THEMAIN CABIN R/H SIDE BETWEEN STA'S 279 AND 781.5 AND L65R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SNov 6, 2000 · N603AL · Doug DC873FSDR RRXA003676Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE AT STA 560 BL 65L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR INov 4, 2000 · N603AL · Doug DC873FSDR RRXA003670Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL ATTACHING ANGLE L/H SIDE AT STA 902-920 AND BL-65, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INNov 4, 2000 · N603AL · Doug DC873FSDR TWAA0017614Floor Panel · crackedDURING OP 15 MAINT CHECK, THE FLOOR MEMBRANE WAS CRACKED AT STA 595, APPROX 56 RBL. STOP DRILLED CRACK WITH 0.025 DIA DRILL AND FABRICATED DOUBLER PER SRM 53-01, FIG 2 SHEET 3. INSTALLED RIVETS PER SRM 51-30-02. PRIMED AND PAINTED PER SRM 51-10-03.Nov 2, 2000 · N992Z · Doug DC931SDR AWXA0000843Web · crackedC-CHECK, CRACK IN HORIZ WEB FLOOR STRUCTURE JUST AFT OF BS 178 BULKHEAD, WL 208, RBL 30. WEB REPLACED ON NR 5323254 BY COMPLIANCE OF AWA EO 53-12-07 (STA 178 BULKHEAD MOD).Nov 2, 2000 · N189AW · Boeing 737277SDR AT0100033Floorboard · corrodedFOUND FORWARD ENTRY FLOORBOARD 4693 CORRODED BEYOND LIMITS. REPLACED FLOORBOARD IAW DC9 SRM 53-01 FIG 1, 51-10-02, 51-10-04, 51-30-03, 51-10-03, AND 51-30-01.Nov 1, 2000 · N839AT · Doug DC932SDR AWXA0000823Floor Panel · crackedC-CHECK, FLOOR WEB CRACKED AT FS 180, LBL 24, WL 207. REMOVED AND REPLACED DAMAGED WEB IAW 737 SRM 51-30-2.Nov 1, 2000 · N189AW · Boeing 737277SDR AWXA0000822Floor Panel · crackedC-CHECK, FLOOR WEB CRACKED AT FS 180, RBL 24, WL 207. REMOVED AND REPLACED DAMAGED WEB IAW 737 SRM 51-30-2.Nov 1, 2000 · N189AW · Boeing 737277SDR RRXA003341Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE COCKPIT FLOOR PANEL NR 677, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 30, 2000 · N957R · Doug DC863FSDR RRXA003340Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND CORROSION AND A CRACK TO THE TOP AND BOTTOM OF THE COCKPIT FLOOR PANEL 679, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 30, 2000 · N957R · Doug DC863FSDR RRXA003339Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BOTH SIDES OF THE COCKPIT FLOOR PANEL UNDER F/E''S DESK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 30, 2000 · N957R · Doug DC863FSDR RRXA003338Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL UNDER FE''S CONSOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 30, 2000 · N957R · Doug DC863FSDR RRXA003334Panel · delaminatedDURING A MAINTENANCE VISIT FOUND THE COCKPIT FLOOR SEPARATED AT STA -12 TO -32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 30, 2000 · N957R · Doug DC863FSDR TWAA0017104Floor Panel · crackedDURING OP 15 MAINT CHECK, THE AFT CABIN FLOOR PANEL NUMBER 69 HAD AFT RT CORNER CRACKED AND CORRODED. FABRICATED NEW FLOOR PANEL PER SSRM 53-00-104.Oct 25, 2000 · N996Z · Doug DC932SDR CALA0001646Floor Panel · crackedINSPECTION FOUND A 1 INCH CRACK IN LEFT O/B FLOOR PANEL EDGE AT FS 927 - 1003. THE CRACK WAS STOP DRILLED IAW SRM 51-10-4. A DOUBLER WAS INSTALLED IAW SRM 51-10-4, 51-10-3, AND 53-01.Oct 25, 2000 · N14871 · Doug DC981SDR QXEA0002913Floorboard · damagedYXX- VARIOUS DISCREPANCIES ON BAGGAGE BAY FLOORBOARDS AS IDENTIFIED ON ATTACH 29A FORM. REPLACED BOARDS AS REQUIRED.Oct 23, 2000 · N364PH · Dhav DHC8202SDR TWAA0017403Floor Panel · corrodedDURING OP 15 MAINT CHECK IN THE FWD CABIN, THE FLOOR MEMBRANE HAD CORRODED AND WORN AT STA 160 TO 200, LBL 44 INCHES. REMOVED MEMBRANE AND FABRICATED NEW PART PER DRAWING AA9910078 AND SRM 51-30-3. INSTALLED PER SRM 51-30-0 AND 51-10-4 OF SRM.Oct 19, 2000 · N996Z · Doug DC932SDR RRXA003234Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND A LARGE HOLE TO THE LT SIDE OF CABIN FLOOR WEB AT STA 120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Oct 19, 2000 · N500MH · Doug DC871FSDR TWAA0016412Web · corrodedDURING OP 15 MAINT CHECK THE FWD CABIN FLOOR MEMBRANE WAS CORRODED AND WORN AT STA 200 TO STA 160, LBL 44 TO LBL 56. REMOVED MEMBRANE AND FABRICATED NEW PART PER DRAWING 9910078 AND SRM 51-30-3. INSTALLED PER SRM 51-30-0 AND 51-10-4.Oct 19, 2000 · N996Z · Doug DC932SDR MWEA001016Floor Panel · bentFLOOR PANEL E-6 SKIN SUPPORT CHANNEL HAS TRAILING EDGE BENT OVER. REMOVED AND REPLACED SUPPORT CHANNEL.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001015Floor Panel · crackedFLOOR PANEL E6 SKIN IS CRACKED IN TRAILING EDGE AREA. FABRICATED AND INSTALLED REPAIR DOUBLER.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001014Floor Panel · chafedFLOOR PANEL F9 SKIN SUPPORT CHANNELS CHAFED. REMOVED AND REPLACED FLOOR PANEL.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001013Floor Panel · damagedFLOOR PANEL F9 SKIN FASTENER HOLE ELONGATED. REMOVED AND REPLACED FLOOR PANEL.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001012Floor Panel · puncturedFLOOR PANEL F9 SKIN IS PUNCTURED. REMOVED AND REPLACED FLOOR PANEL.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001011Floor Panel · corrodedFLOOR PANEL F1 HAS AREAS OF MODERATE CORROSION ON TOP AND BOTTOM SIDE OF SKIN. FABRICATED AND INSTALLED REPAIR DOUBLER.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001010Floor Panel · chafedFLOOR PANEL SUPPORT CHANNELS CHAFED AT F6 PANEL. REMOVED AND REPLACED SUPPORT CHANNELS.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA001009Floor Panel · damagedFLOOR PANEL A7 SUPPORT CHANNEL IS DE-BONDED ON TRAILING EDGE. REMOVED AND REPLACED HAT CHANNELS AND CHAFE STRIPS.Oct 18, 2000 · N302ME · Doug DC932SDR MWEA00938Floor Panel · crackedCORNER CRACKED ON CABIN FLOOR PANEL B5. FABRICATED AND INSTALLED REPAIR DOUBLER.Oct 18, 2000 · N302ME · Doug DC932
Back to JASC 5321