JASC 5322
Service difficulty reports · 12,776
Reports filed under 5322 · Fuselage Internal Mounting Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2021102000699Doubler · corrodedDURING HEAVY MAINTENANCE, CORROSION: INNER DOUBLER OF WASTE BOX @ FR88-89 STR28R ; REF TOMX 00426: REPAIRED INNER DOUBLER OF WASTE BOX @ FUSELAGE INTERNAL STRUCTURE BETWEEN FR88-89 STR28R IAW SRM 53-23-60/REPAIR 51P.SDR YENA2021102000697Web · corrodedDURING HEAVY MAINTENANCE, CORROSION ON FWD WEB OF LOWER BEAM @ FWD CARGO COMPARTMENT DOOR CUTOUT ; REF TOMX NR 00480: R & R DAMAGED DOUBLER AT FWD CARGO COMPARTMENT DOOR CUTOUT IAW SRM 51-41-02 AND SRM 51-43-04.SDR YENA2021102000693Bracket · corrodedDURING HEAVY MAINTENANCE, CORROSION: BRACKETS (2EA) AT FUSELAGE INTERNAL STRUCTURE FR86-87 STR27-28R ; REF TOMX NR 00593: R & R BRACKETS (2EA) AT FUSELAGE INTERNAL STRUCTURE BETWEEN FR86-87 STR27-28R IAW SRM 51-41-01 PAR 4, 51-41-02 PAR 4, 51-41-01 PAR 6, AND SDR YENA2021102000692Frame · corrodedDURING HEAVY MAINTENANCE, CORROSION: FR82 BETWEEN STR27-28R FRAME CLIP AFT CARGO COMPARTMENT ; REF TOMX NR 00275: R & R FRAME CLIP FR82 STR27-28R IAW SRM 51-41-02, 51-41-01, AND 51-43-01.SDR YENA2021102000691Frame · corrodedDURING HEAVY MAINTENANCE, CORROSION: FR83 BETWEEN STR27-28R FRAME CLIP AFT CARGO COMPARTMENT ; REF TOMX NR 00276: R & R FRAME CLIP FR83 STR27-28R IAW SRM 51-41-01, 51-41-02, AND 51-43-02.SDR YENA2021102000690Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION: SHEAR CLIP AFT CARGO INTERNAL STRUCTURE FR75 BETWEEN STR 29R-29L ; REF TOMX NR 00558: R & R SHEAR CLIP @ AFT CARGO FR75 STR29R-29L IAW SRM 51-41-01 AND 51-41-02.SDR SWIA202163642None · corrodedLH FLOOR SILL HAS MULTIPLE SPOTS OF CORROSION FROM FS985 TO FS1000 (C CHECK RO 01-05-2022) REMOVED AND REPLACED LH FLOOR SILL @ STA. 985-1000 IAW REO 670-53-61-2007 REV A DATED 2021-11-23 . REF CONTINUATION CARD FOR WORK PERFORMED. SKYWEST 51-900-1002-SKY SDR SWIA202163640None · corrodedRH FLOOR SILL CORRODED AT FS 280.00 (C CHECK RO 01-05-2022) REMOVED DAMAGED RH FLOOR SILL AND INSTALLED A NEW SILL IAW CRJ 700 SRM 51-42-06-001-001-A01, AND 51-42-21-001-001-A01. NO WEIGHT CHANGE, TASK CARD 51-900-1002-SKY AND M-337 ATTACHED.SDR V0XD20211102002None · corrodedL/H SIDE WALL SEAT RAIL IS CORRODED FROM F.S 907 TO F.S 977. CORRECTIVE ACTION: REMOVED AND REPLACED L/H WALL SEAT RAIL F.S. 907 TO F.S 977 (P/N: SH690-37542-1) IAW CRJ 900 AMM 53-00-49.SDR SWIA202163207None · cracked*FLOOR BEAM RBL9 OUTBOARD CLIP ATTACHING TO FS280.00 CROSS BEAM IS CRACKED. (MARKED) (C CHECK RO 12-19-21) REMOVED AND REPLACED FLOORBEAM OUTBD CLIP AT RBL9 FS280 REF CRJ 700 SRM 51-42-06-001-001-A01SDR SWIA202163142None · corroded*LEFT FLOOR SILL HAS CORROSION FS280.00 €“ FS310.00. (MARKED) (C CHECK RO 12-19-21) REMOVED AND INSTALLED NEW LH FLOOR SILL AT FS280-310 REF. CRJ700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV-V. LEAK CHECK GOOD. COMPLIED WITH TASK CARD 51-900-1002-SSDR SWIA202163140None · corroded*RIGHT FLOOR SILL HAS CORROSION FS280.00 €“ FS319.00. (MARKED) (C CHECK RO 12-19-21) REPLACED RH FLOOR SILL AT FS280.00-FS319.00 REF. CRJ700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV. NC. SEE CONTINAUTION FOR DETAILS. LEAK CHECK GOOD. / COMPLIED WISDR SWIA202163136None · corroded*SILL IS CORRODED @STRG 17RH BETWEEN FS985.00 AND FS1000.00 (C CHECK RO 12-19-21) REMOVED CORROSION ON SILL AT STGR 17LH BETWEEN FS985.00 - FS1000.00 REF CRJ700 SRM 51-21-06-001-001-A01 ORIGINAL THICKNESS .063 MATERIAL REMOVED .003 MATERIAL REMAINING .060SDR SWIA202163056None · corrodedR/H FLOOR SILL BTW F/S 310-319.7 HAS MULTIPLE AREAS WITH EVIDENCE OF CORROSION (C-CHECK RO 12/07/2021) REMOVED AND INSTALLED NEW FLOOR SILL FROM FS 280.00 TO FS 319.00 REF. BOMBARDIER DWG NO. SH670-30002 REV A, BOMBARDIER DWG NO. SH670-32170 REV M,CRJ 7SDR SWIA202162511None · corroded*FS280 FLOOR PANEL SUPPORT ANGLE CORRODED (MARKED) (C-CHECK RO 11/10/2021) REMOVED AND REPLACED WITH NEW ANGLE AT FS280.00 FOR FLOOR PANEL SUPPORT. REF CRJ 700 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 BOMBARDIER DRAWING CC670-34010 REV K, DWG CC670-SDR YENA2021100500652Mount Fitting · out of limitsDURING HMV, FUSELAGE (AVENT/ VIASAT2 MOD) FWD FUSELAGE/ FR33-34 & STGR 5R-6R/ SHORT EDGE DISTANCE- TEMPORARY REPAIR (CLASSIFIED AS A MAJOR REPAIR)SDR SWIA202163343None · corrodedFS 574 CROSSBEAM CAP CORRODED LBL 9 TO RBL 9. (C CHECK RO 12/28/2021) REMOVED AND REPLACED FS574 CROSSBEAM CAP LBL9 TO RBL9 IAW CRJ 200 SRM 51-42-06.SDR SWIA202163342None · crackedFS 604 FRAME TO FLOOR SILL ATTACH ANGLE AT LBL 44 IS CRACKED. (C CHECK RO 12/28/2021) REMOVED AND REPLACED CRACKED FLOOR TO SILL ATTACH ANGLE IAW CRJ 200 SRM 51-42-21SDR SWIA202163291None · corrodedLH FLOOR SILL PANEL CORRODED FROM FS 409+128 TO FS 559. (C CHECK RO 12/28/2021) REPAIRED LH FLOOR SILL PANEL CORROSION FROM FS 409+128 TO FS 559 IAW REO 601R-53-41-666 REV C, DATED 2012-11-06 AND CRJ 200 SRM 51-25-00. COMPLIED WITH TASK CARD 51-900-1003-SKSDR SWIA202163309None · damagedFLOOR SUPORT POST'S AT RBL.18, STR.27, AND LBL.18 ON FWD FACE OF PRESSURE BULKHEAD AT FS.409.00+128 HAVE SEVERAL JO BOLTS THAT PULLED SHORT DURING INSTALLATION AND SOME ARE LOOSE IN HOLES. (C CHECK RO 12/28/2021) REMOVED AND REPLACED 9EA JO BOLTS IAW REO SDR SWIA202163783None · damagedREMOVE AND REPLACE FLOOR SUPPORT BEAM AT LBL 9, FROM FS 858.00 - 939.00 (C-CHECK RO 1/13/2022) REMOVED AND REPLACED CORRODED LONGITUDINAL FLOOR BEAM WITH A NEW SUPPORT AT LBL9 FROM FS858.00 TO FS939.00 PER CRJ700 SRM 53-00-41-201-001-A01. PAGE 207 PARSDR SWIA202163337None · corrodedPAX DOOR SILL ANGLE IS HEAVILY CORRODED BETWEEN F.S. 310.00 AND F.S. 349.00 ON THE OUTBOARD AND INBOARD FACES. (C CHECK RO 12/28/2021) REMOVED AND REPLACED PAX DOOR SILL ANGLE IAW CRJ 200 SRM 51-42-21 & 51-42-06 REFERENCE CONTINUE CARD FOR WORK PERFORMED.SDR SWIA202163286None · corrodedRBL 9.00 FLOOR BEAM CAP IS HEAVILY CORRODED ON THE INBOARD FLANGE BETWEEN F.S. 409.00 TO F.S. 409.00+128. (C CHECK RO 12/28/2021) REPAIRED CORRODED RBL 9.00 FLOOR BEAM CAP ON THE INBOARD FLANGE BETWEEN FS 409.00 TO 409.00+128. REFERENCE CONTINUATION CARD FSDR SWIA202163307None · corrodedSTRAP BETWEEN FLOOR BEAM AND PRESSURE FLOOR SILL BETWEEN LBL 27.00 AND LBL 36.00 AT F.S. 559.00 IS CORRODED. (C CHECK RO 12/28/2021) REMOVED AND REPLACED STRAP BETWEEN FLOOR BEAM AND PRESSURE FLOOR SILL BETWEEN LBL 27.00 AND LBL 36.00 AT F.S. 559.00 IAW CRSDR SWIA202163285None · corrodedLBL 9.00 FLOOR BEAM HAS APPROX. (9) AREAS OF MINOR CORROSION ALONG THE OUTBOARD FLANGE BETWEEN F.S. 409.00+128 AND F.S. 559.00. (C CHECK RO 12/28/2021) REPAIRED LBL9 FLOORBEAM FS409+128 AND FS559 IAW MHIRJ REO 601R-53-41-2974 REV-- DATED 2021-11-03. REFERESDR SWIA202162659None · unreliableCOMPLY WITH: 670BA-53-036 - FUSELAGE - CENTER FUSELAGE, FS669.40 TO FS855.40 - REPLACEMENT OF THE BEAMS AF LBL36 AND RBL36, AND THE FLOOR ASSEMBLY BETWEEN FS693.00 AND FS847.00 WITH BEAMS INSTALLED AT BL0, LBL9, LBL18, LBL27, RBL9, RBL18 AND RBL27 REV D PART(SDR SWIA202163782None · corrodedREPLACE CORRODED FLOOR SUPPORT BEAM AT RBL9 FROM FS858 TO FS939. (C-CHECK RO 1/13/2022) REMOVED AND REPLACED CORRODED FLOOR BEAM SUPPORT AT RBL9 FROM FS858 TO FS939 PER CRJ700 SRM 53-00-41-201-001-A01, SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-ASDR DALA2021092505766Shear Tie · corrodedSHIP 194 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1285 ,BETWEEN S-37L AND S-36L. REPLACED SHEAR TIE. (LP 1960943)SDR DALA2021092505765Shear Tie · corrodedSHIP 194 DURING INSPECITON MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1395 ,BETWEEN S-37R AND S-36R. SHEAR TIE REPLACED. (LP 1960939)SDR DALA2021092505764Shear Tie · corrodedSHIP 194 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1197+88 ,BETWEEN S-36L AND S-35L. REPLACED SHEAR TIE.(LP 1960937)SDR DALA2021092505763Shear Tie · corrodedSHIP 194 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1219,BETWEEN S-39L AND S-38L. REPLACED SHEAR TIE. (LP 1960934)SDR DALA2021092505762Shear Tie · corrodedSHIP 194 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1439 ,BETWEEN S-35L AND S-36L. SHEAR TIE REPLACED. (LP 1960931)SDR DALA2021092505761Shear Tie · corrodedSHIP 194 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 AFT CARGO COMPARTMENT FOUND 01EA SHEAR TIE SURFACE CORROSION AT STA 1241 ,BETWEEN S-35L AND S-34L. SHEAR TIE REPLACED. (LP 1960930)SDR SWIA202163781None · corrodedREPLACE CORRODED LONGITUDINAL FLOOR SUPPORT BEAM FROM FS565.00 TO FS661.00, LBL 9 (C-CHECK RO 1/13/2022) REMOVED AND REPLACED CORRODED LONGITUDINAL FLOOR BEAM WITH A NEW SUPPORT AT LBL9 FROM FS565 TO FS661 PER CRJ700 SRM 53-00-41-201-001-A01. PAGE 207 SDR SWIA202161775None · corrodedCORROSION- LH FLOOR DOUBLER HAS CORROSION AROUND MOUNT HOLE AS MARKED FR 19-20. (C-CHECK RO 10/10/2021) REMOVED AND REPLACED LH FLOOR DOUBLER FR 19-20 REF EMB SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202161774None · corrodedCORROSION- LH FLOOR SILL CORRODED AT NUT PLATE HOLE FR 19-20. (C-CHECK RO 10/10/2021) REMOVED AND REPLACED LH FLOOR SILL FR 19-20 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202161773None · corrodedCORROSION- RH FLOOR SILL CORRODED AS MARKED FR 12-14. (C-CHECK RO 10/10/2021) REMOVED AND REPLACED RH FLOOR SILL AT FR 12-14.REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202161772None · corrodedCORROSION- LH FLOOR DOUBLER CORRODED AS MARKED AT MOUNT HOLE AT FR 16 (C-CHECK RO 10/10/2021) REMOVED AND REPLACED LH FLOOR DOUBLER AT FR 16. REF EMB SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202161771None · corrodedCORROSION- LH FLOOR SILL CORRODED AS MARKED AT FR 16. (C-CHECK RO 10/10/2021) REMOVED CORRODED LH FLOOR SILL AT FR16. LOCATED , DRILLED AND INSTALLED NEW LH FLOOR SILL AT FR16 AND RESTORED SURFACE PROTECTION REF EMB SRM 51-40-08SDR SWIA202161769None · corrodedCORROSION- RH FLOOR BEAM SEAT TRACK HAS CORROSION IN TRACK AS MARKED FR 21-22. (C-CHECK RO 10/10/2021) REMOVED AND REPLACED RH INBD FLOOR SEAT TRACK AT FR 12-21 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06 PART REPLACEMENT MADE BY FACSDR DALA2021092805840None · noneSHIP 6816 CRACK ON FLOOR BEAM STABILIZATION STRAP BTW STA 365.25-377,7 AND APROX LBL 25 AT NLG LH TUNNEL.(E/E). CORRECTIVE ACTION: SUMMARY OF NRC 00082-FLOOR BEAM STABILIZATION STRAP BTW STA 365.25-377,7 AND APROX LBL 25 AT NLG LH TUNNEL, WAS REPAIRED PER B757SDR SWIA202162710None · corroded*CORROSION ON STGR 27 TOP FLANGE BETWEEN FS280.00 €“ 295.00 (C-CHECK RO 11-20-2021) REMOVED CORROSION FROM STGR 27 TOP FLANGE BETWEEN FS280.00 €“ 295.00 PER CRJ700 SRM 51-21-06-001-001-A01. NO DAMAGE ALLOWED ON STGR 27 TOP FLANGE BETWEEN FS280.00 €“ 295SDR SWIA202162705None · corroded*CORROSION ON FLOOR SUPPORT CROSSBEAM FS 1051.00 TOP SURFACE BETWEEN RBL 27 €“ 36 (C-CHECK RO 11-20-2021) COMPLIED WITH ALL STEPS IN REPAIR ON FLOOR SUPPORT STRUCTURE AT FS1051.3, OUTBD OF RBL-27. CONDITION IS STRUCTURALLY ACCEPTABLE. REF REO 670-53-61-1SDR SWIA202161905None · corrodedRH FLOOR SILL AFT OF SERVICE DOOR FROM FS349-FS364 HAS CORROSION. (C-CHECK RO 10/22/2021) REPAIRED RH FLOOR SILL AFT OF SERVICE DOOR FROM FS349-FS364 REF REO 690-53-21-1429 REV.-- DATED 2021-09-27. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.SDR DALA2021092205695None · noneSHIP 649 CRACK ON FLOOR SUPPORT BTW STA 460 STA 440 S27R AT E/E COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00715. FLOOR SUPPORT WAS REPAIRED PER B757-200 SRM. (1956587)SDR SWIA202161645None · corrodedREO 601R-53-41-2967 REV -- DATED 2021-09-18 REQ'S COMPLETION FOR CORROSION AT RBL 9 FLOOR BEAM BETWEEN FS 409+128- FS 559 (C-CHECK RO 10/07/2021) VERIFIED ALL STEPS OF REO 601R-53-41-2967 REV--, DATED 2021-09-18 HAVE BEEN COMPLIED WITH. REFERENCE CAMP # 2SDR DALA2021092005580Shear Tie · corrodedSHIP 3265 CORROSION SHEAR TIE LOCATED FR33 AND BTW STR 42R TO STR 43R IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED SHEAR TIE AND FASTENERS AS PER SRM 51-72-11. (1954090)SDR SWIA202162247None · corroded*CORROSION ON RH FLOOR SILL AT NUTPLATE LOCATIONS BETWEEN FS1069.75 AND FS1088.20 (MARKED). (C-CHECK RO 11/04/2021) REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS1069.75 & FS1088.20 REF-CRJ-900 SRM 51-21-06-001-001 A01,AREA REWORKED FOUND TO BE WITHIN LIMITSDR SWIA202162246None · corroded*CORROSION ON RH FLOOR SILL AT NUTPLATE LOCATIONS BETWEEN FS1047 AND FS1069.75 (MARKED). (C-CHECK RO 11/04/2021) REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS1047 & FS1069.75 REF-CRJ-900 SRM 51-21-06-001-001 A01,AREA REWORKED FOUND TO BE WITHIN LIMITS REF-SDR SWIA202162245None · corroded*CORROSION ON RH FLOOR SILL AT NUTPLATE LOCATIONS BETWEEN FS1015 AND FS1031 (MARKED). (C-CHECK RO 11/04/2021) REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS1015 & FS1031 REF-CRJ-900 SRM 51-21-06-001-001 A01,AREA REWORKED FOUND TO BE WITHIN LIMITS REF-CRJ-9
Back to JASC 5322