SDR SWAA2024080908577Floor Panel · pulledAFT FLOOR PANEL 241ABF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 241ABF AFT FLOOR PANEL UPPER SKIN HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0088.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR JJBA20240404011Channel · crackedAT CF3 FLOOR STRUCTURTE AREA, CRACK FOUNF ON L/H OMEGA BEAM OUTBD ANGLE BTW FR 46-50 ON L/H OMEGA BEAM OUTBD ANGLE REPLACEDSDR QXEA2024031800067Seat Track · corrodedCORROSION IN RH IB SEAT TRACK FR 84. REMOVED DAMAGED SECTION AND PERFORMED SEAT TRACK SPLICE REPAIR, INSTALLED SEAT TRACK SPLICES AND NEW SEAT TRACK SECTION ON RH IN SEAT TRACK AT FR 84 REF ETD2022-170-022163.SDR YENA2023111601393Unknown · unknownDURING HEAVY MAINTENANCE: FUSELAGE / CENTER FUSELAGE III STR28R / BWTN FR86-FR90 /CORROSION - PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)SDR SWI2023F00590Unknown · corrodedCORROSION ON GALLEY FLOOR FWD INBD MOUNT FITTING BETWEEN FS 280.00 - 295.00, RBL9-RBL18 HN00118605 (C-CHECK RO 12/23/2023) EVALUATED ON GALLEY FLOOR FWD INBD MOUNT FITTING BETWEEN FS 280.00 - 295.00, RBL9-RBL18 CORROSION IS EXFOLIATED AROUND NUTPLATE HOLESDR QXEA2023032000039Unknown · unknownCORROSION IN SHEAR CLIP FR 87 BETWEEN STR 27-28R. REMOVED AND REPLACED SHEAR CLIP FR-87 BETWEEN STR 27-28R SRM 51-40-08.SDR SWIA20230519042Unknown · corrodedGALLEY FLOOR SUPPORT STRUCTURE CORRODED AT FS319.70 BETWEEN RBL 9 AND LBL9 (UPPER AND LOWER PLATES) (C-CHECK RO 5/15/2023) REMOVED AND REPLACED WITH NEW GALLEY FLOOR SUPPORT STRUCTURE PLATE BOMBARDIER DWG 601R38778 REV-H AND REF CRJ200 SRM 51-42-06 REVSDR SWAA2023020782456Structure · corrodedCORROSION FLOOR STRUCTURE STRAP LOCATED BS1006 TO BS1040 AT LBL3 AND WL208.1 AT AFT GALLEY AREA 2022-696985<[01] TOOL USED UT EQUIPMENT P/N: 45MG; S/N: 130066701; CAL DUE DATE: 08-APR-23;[02] REPLACED STRAP LOCATED FLOOR STRUCTURE STRAP LOCATED BS1006 TO BS104SDR A6WA202210158343Shear Plate · corrodedINBOARD OF RBL9 AT FS310 AND FS330.0 SHEAR PLATE AND MOUNT CORROSION ***AIRCRAFT REMOVED FROM SERVICE **** REMOVED AND REPLACED INBOARD OF RBL9 AT FS310 AND FS330.0 SHEAR PLATE AND MOUNTSDR SWAA2022082430778Strip · elongatedAFT CARGO L/H SIDE CAP STRIPS FOUND WITH ELONGATED HOLES / [01] RECEIVED AFT CARGO CAP STRIPS P/NS 453A2611-10; 453A2611-8; 453A2611-4;[02] VERIFIED RECEIVING AFT CARGO CAP STRIPS P/NS 453A2611-10; 453A2611-8; 453A2611-4;[03] STEP 1 ENTER IN ERROR ; RECEIVED ASDR YENA2022070500645None · noneDURING HEAVY MAINTENANCE, FUSELAGE: SEVERAL CORROSION POINTS ON STILL, RIGHT-FLOOR, FWD FUS, AL BTW FR-12 / FR-14
AND Y+1200 AND +1298; ALL WORK ACCOMPLISHED ON TOMEX NRC 00208, CORROSION ON STILL, RIGHT-FLOOR, FWD FUS, AL BTW FR-12 / FR-14 AND Y+1200 / +12SDR YENA2022070500644None · noneDURING HEAVY MAINTENANCE, FUSELAGE: CENTER FUSELAGE III, FLOOR BEAM SEAT TRACK AT FR84 AND Y=330. CORROSION. PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)SDR R61A2022071400430Skin Panel · corrodedREPAIRED CFIII SKIN CORRODED FWD OF LAV SERVICE DOOR BY MEANS OF BLENDING OUT DAMAGE AND INSTALLING FABRICATED DOUBLER REF EMB SRM 53-23- 60/REPAIR01.SDR YENA2022061400602Stringer · corrodedDURING HEAVY MAINTENANCE, FUSELAGE/ CENTER FUSELAGE III / FRAME 80 / STRINGERS 26R AND 28R / CORROSION / TEMPORARY REPAIR. (CONSIDERED AS A MAJOR REPAIR)SDR YENA2022061400601Stringer · corrodedDURING HEAVY MAINTENANCE, FUSELAGE/ CENTER FUSELAGE III / FRAME 80 / STRINGERS 26R AND 28R / CORROSION/ PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR)SDR EE4Y202260715775Skin Panel · noneCENTER FUSELAGE III BETWEEN FR89 AND FR90 COMMON TO STR 13LH EXISTING REPAIR WITH A DISCREPANCY. NOTE: THE FUSELAGE SKIN PANEL WAS REPAIRED AS PER EMBRAER ETD2022-190-018961 GUIDELINES AS STATED IN COOPESA ENGINEERING ORDER NO: COO-CO 2022-15755 INSTRUCTIONS (SDR YENA2022051700486Skin · corrodedDURING HEAVY MAINTENANCE, FUSELAGE / CENTER FUSELAGE III / LOWER SKIN / BTW FR86 - FR87 AND STGR 29LH - 29RH / CORROSION - PERMANENT REPAIR. (CONSIDERED AS A MAJOR REPAIR).SDR QXEA2022041300150None · noneCORROSION ON CENTER FUSELAGE III RH SPLICE FR 89 AND Y=+11. REMOVED AND REPLACED CENTER FUSELAGE III SPLICE BETWEEN FR 89 AND Y=+11 IAW SRM 51-40-08.SDR QXEA2022041300149Shear Panel · corrodedCORROSION ON CENTER FUSELAGE III RH SHEAR PANEL BETWEEN FR 87-88 AND Y=+12. REMOVED AND REPLACED CENTER FUSELAGE III RH SHEAR PANEL BETWEEN FR 87-88 AND Y=+12 IAW SRM 51-40-08.SDR SWIA202265382None · corrodedSTILL RIGHT FWD WET AREA FRAME 12-14 TWO AREAS OF CORROISION AS MARKED. (C CHECK RO 4/16/22) CORROSION OUT OF LIMITS REF. EMB SRM 53-10-10/AD06. REMOVED AND REPLACED SILL AT RIGHT FWD WET AREA FRAME 12-14 REF. EMB SRM 51-40-08.SDR SWIA202265297None · corrodedCORROSION ON FWD WET AREA L/H FLOOR DOUBLER BETWEEN FR19-20 AS MARKED. (C CHECK RO 04/08/22) / REMOVED AND REPLACED OUT OF LIMITS DOUBLER WITH NEW L/H DOUBLER FR19-20 IN WET AREA AS REQUIRED REF SRM 51-40-08SDR SWIA202265282None · corrodedCORROSION ON FWD WET AREA R/H FLOOR BEAM BETWEEN FR13-18 IN 6 LOCATIONS AS MARKED. (C CHECK RO 04/08/22) / REMOVED AND REPLACED R/H FLOOR BEAM BETWEEN FR12-21 REF EMB SRM 51-40-08. BEAM WAS REPLACED WITH OEM PART NO CHANGE TO WEIGHT AND BALANCE NOTED. SESDR SWIA202265292None · corrodedCORROSION FOUND IN AFT WET AREA LOCATED ON FR 87 AT LBL 4.375" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW MIDDLE SHEAR PLATE AT AFT WET AREA LOCATED ON FR 87 AT LBL 4.375", REF SRM 51-40-08SDR SWIA202265291None · corrodedCORROSION FOUND IN AFT WET AREA LOCATED ON GUSSET PLATE FR 87 AT RBL 40" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED LOCATED ON GUSSET PLATE FR 87 AT RBL 40", REF SRM 51-40-08.SDR SWIA202265290None · corrodedCORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT RBL 23" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW GUSSET AT AFT WET AREA LOCATED ON FR 90 AT RBL 23", REF SRM 51-40-08.SDR SWIA202265289None · corrodedCORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT RBL 11" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED WITH NEW GUSSET AT AFT WET AREA LOCATED ON FR 90 AT RBL 11", REF SRM 51-40-08.SDR SWIA202265288None · corrodedCORROSION FOUND IN AFT WET AREA LOCATED ON FR 90 AT LBL 4.375" AS MARKED. (C CHECK RO 04/08/22) REMOVED AND REPLACED GUSSET AT FR 90 AT LBL 4.375" REF EMB SRM 51-40-08SDR SWIA202265287None · corrodedCORROSION FOUND IN AFT WET AREA ALONG RH SHEAR PANEL ON FR 87. (C CHECK RO 04/08/22) REMOVED AND REPLACED RH SHEAR PANEL ON FR 87, REF SRM 51-40-08.SDR SWIA202265815None · crackedTHE GALLEY #2 HAS A CORRODED OTBD/FWD FLOOR MOUNT FITTING (ROUND FITTING). (C CHECK RO 5/23/22) REPLACED THE GALLEY #2 OTBD/FWD FLOOR MOUNT FITTING WITH A SERVICEABLE FLOOR MOUNT FITTING (P/N 9393251-3) AND NEW HARDWARE REFERENCING CRJ 900 SRM 51-41-02-0SDR QXEA2022031400115Shear Panel · corrodedCORROSION ON FUSELAGE III FLOOR STRUCTURE RH SHEAR PANEL BETWEEN FR 87-88 AND Y= +24. REMOVED AND REPLACED SHEAR PANEL BETWEEN FR 87-88 AND Y= +24 IAW SRM 51-40-08.SDR SWIA202265125None · corrodedFWD WET AREA RIGHT STILL AT FR 14 HAS CORROSION ON AFT LH CORNER (C-CHECK RO 03-19-2022) REMOVED AND REPLACED FWD WET AREA RIGHT SILL AT FR 14 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06 AND CPM 51-25-00910-001-ASDR R61A2022031000188Seat Track · corrodedFWD FUSELAGE FLOOR CORROSION FOUND ON I/B L/H SEAT TRACK BTWN FR 18-19. R&R SEAT TRACK FWD FUSELAGE L/H I/B FR 12-FR20 IAW EBM 170/175 SRM 51-41-01, 51-41-02, 51-43-03 AND 51-43-04.SDR SWIA202264788None · corrodedAFT WET AREA, RH SIDE, PANEL, SHEAR CORRODED IN 2 PLACES, 2ND AND 4TH BOLT HOLES FROM RH END (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA, RH SIDE, PANEL, SHEAR REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202264787None · corrodedAFT WET AREA, RH SIDE, PANEL SUPPORT CORRODED IN 2 PLACES, AFT AND CENTER BOLT HOLES (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA RH SIDE PANEL SUPPORT REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-04, 50-23-05, AND 51-23-06.SDR SWIA202264786None · corrodedAFT WET AREA, RH SIDE, GUSSET PLATE CORRODED AT INBOARD BOLT HOLE (C CHECK RO 03/07/2022) REMOVED AND REPLACED AFT WET AREA, RH SIDE, GUSSET PLATE AT FR90 REF EMB SRM 51-40-08 RESTORED SURFACE PROTECTION REF SRM 51-23-06 APPLIED CIC REF CPM 51-25-00SDR SWIA202264576None · corrodedAFT WET AREA FR89 R/H PANEL SUPPORT CORRODED THRU AT GALLEY MOUNT BOLT AREA (C CHECK RO 02/21/2022) REMOVED AND REPLACED RH PANEL SUPPORT FR89 REF SRM 51-40-08SDR SWIA202264575None · corrodedAFT WET AREA FR90 R/H SIDE GUSSET PLATE (TEXAS) CORRODED AT GALLEY MOUNT BOLT HOLE (C CHECK RO 02/21/2022) REMOVED AND REPLACED CORRODED AFT GUSSET PLATE FR90 R/H WITH NEW GUSSET PLAT AS REQUIRED REF SRM 51-40-08SDR SWIA202264564None · corrodedR/H OUTBOARD FLOOR SILL PLATE CORRODED AT FR.17 AS MARKED. (C CHECK RO 2/20/2022) REMOVED AND REPLACED CORRODED R/H OUTBOARD FLOOR SILL PLATE AT FR.17 AS MARKEDWITH NEW FLOOR SILL REQUIRED REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202264563None · corrodedR/H FORWARD OUTBOARD SILL PLATE CORRODED AT FR.14 (C CHECK RO 2/20/2022) REMOVED AND REPLACED R/H FWD OB SILL PLATE AT FRAME 12-14 REF EMB SRM 51-40-08SDR SWIA202265199None · corrodedCORROSION FOUND UNDERNEATH GIRT BAR FITTINGS AT SERVICE DOOR LOWER THRESHOLD FS319.70 TO FS349.00 STR17R (C-CHECK RO 3-25-22) REMOVED LOWER THESHOLD ANGLE REF CRJ 200 SRM 51-42-06 AND 51-42-36, INSTALLED LOWER THESHOLD ANGLE REF CRJ 200 SRM 51-42-06, REF SDR SWIA202264562None · corrodedCORROSION ON AFT WET AREA GUSSET PLATE AT FR90 RBL 10" AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED AFT WET AREA GUSSET PLATE AT FR90 RBL 10", REF SRM 51-40-08SDR SWIA202264561None · corrodedCORROSION ON AFT WET AREA GUSSET PLATE AT FR90 RBL 28" AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED AFT WET AREA GUSSET PLATE AT FR90 RBL 28", REF SRM 51-40-08.SDR SWIA202264560None · corrodedCORROSION ON AFT WET AREA R/H PANEL SUPPORT BETWEEN FR88-91 AS MARKED. / (C CHECK RO 2/20/2022) REMOVED AND REPLACED AFT WET AREA RH PANEL SPPORT BRACKET FRAME 88-91 REF SRM 51-40-08. APPLIED SURFACE PROTECTION RE SRM 51-23-06SDR QXEA2022012800036Support Angle · corrodedCORROSION ON CENTER FUSELAGE III RH INTERCOSTAL BETWEEN FR 90-FR 91 AND Y= +10. REMOVED AND REPLACED CENTER FUSELAGE III RH INTERCOSTAL SUPPORT ANGLE AT FR 90-FR 91 AND Y +10 IAW SRM 51-40-02, 51-40-08.SDR QXEA2022012800035Not Reported · not reportedCORROSION ON CENTER FUSELAGE III RH LONGITUDINAL BEAM AT FR 87 AND Y= +10. REMOVED AND REPLACED CENTER FUSELAGE III RH LONGITUDINAL BEAM AT FR 86 TO-FR 89 AND Y +10 IAW SRM 51-40-02, 51-40-03,51-40-08.SDR QXEA2022012800033Gusset · corrodedCORROSION ON CENTER FUSELAGE III GUSSET AT FR 90 AND Y= +10. REMOVED AND REPLACED GUSSET AT CENTER FUSELAGE III FR 90 AND Y +10 IAW SRM 51-40-02, 51-40-08.SDR YENA2022031500200Stringer · corrodedDURING HEAVY MAINTENANCE, (E/C E22-008-02) FUSELAGE/ CENTER FUSELAGE III / STRINGERS 28LH AND 29 RH / FR
76-77 CORROSION/ PERMANENT REPAIR (CLASSIFIED AS A MAJOR REPAIR)SDR YENA2022031500197Stringer · corrodedDURING HEAVY MAINTENANCE, (E/C E22-008-01) FUSELAGE/ CENTER FUSELAGE III / STRINGERS 28LH AND 29 RH / FR
76-77 CORROSION/ TEMPORARY REPAIR (CLASSIFIED AS A MAJOR REPAIR)SDR SWIA202264322None · damagedRH CARGO FLOOR SILL FROM FS559+80 FS 559.00+112 REQURE REPLACEMENT (C CHECK RO 02-12-2022) REMOVED AND INSTALL NEW R/H CARGO FLOOR SILL FROM FS559+80 FS 559.00+112 IAW CRJ-200 SRM 51-42-21, CRJ-200 SRM 51-42-06, CRJ-200-SRM 51-45-00 AND DRW# 601R31133 SDR A6WA202101118063Skin · dentedAIRCRAFT R/H SKIN EXTERIOR HAS 1 EACH DENT AT FS 394.00+10" AND S19R TO S20R. DENT DIMENSIONS ARE: (P1) .500L X .500W X .007D. EVALUATED DENT AND FOUND NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 53-00-31 REV. 38. ****************AIRCRAFT REMOVED FROM SERVICE