JASC 5340
Service difficulty reports · 22,407
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2017031915298Support Fitting · crackedINSPECTION TYPE: 3C, CENTER CARGO AFT OVERHEAT DETECTOR SUPPORT ASSY IS CRACKED. REPAIRED THE SUPPORT IAW EA 011-2610-01-A6701 REV I/R, AND EO MD11-2610-63562-A.SDR NACA2017022700015Stringer Clip · crackedCRACKED STRINGER CLIP BS 663, STRINGER 10R, REPLACED THE STRINGER CLIP IAW SRM 51-30-2, REV 113.SDR NACA2017022700014Stringer Clip · crackedCRACKED STRINGER CLIP BS 663, STRINGER 10L, WL 256. REPLACED THE STRINGER CLIP IAW SRM 51-30-2 REV 113, & DWG 65-46541 REV H.SDR NACA2017022700003Stringer Clip · crackedCRACKED STRINGER CLIP AT BS 967, STRINGER 22L. REPLACED IAW SRM 51-30-2 REV 113 AND DWG 65-46563 REV -.SDR NACA2017022700002Tee Fitting · crackedCRACKED TEE ON FORWARD CARGO DOOR INTERNAL STRUCTURE AT BS 470. THE TEE WAS REPLACED IAW DWG 65-46921 REV M, AND SRM D6-15565 REV 113 51-30-02.SDR AALA201703299002Fitting · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK INDICATION ON LEFT HAND WINDSHIELD SIDE POST HOLE NR 3 AT Y1200 AND FR 4, UPPER ATTACHMENT AREA IN COCKPIT. REPLACED FITTING PER EA 267901.SDR IPXA2017030614757Fitting · corrodedINSPECTION TYPE: 3C, RIGID CARGO BARRIER FLOOR FITTING NR 7 HAS CORROSION. REPAIRED THE FITTING IAW EA 011-5340-01-A6684 REV. I/R, AND EO MD11-5340-63478-A.SDR IPXA2017030614756Fitting · corrodedINSPECTION TYPE: 3C, RIGID CARGO BARRIER FLOOR FITTING NR 5 HAS CORROSION. REPAIRED THE FITTING IAW EA 011-5340-01-A6688 REV. I/R, AND EO MD11-5340-63476-A.SDR IPXA2017030614755Fitting · corrodedINSPECTION TYPE: 3C, RIGID CARGO BARRIER FLOOR FITTING NR 8 HAS CORROSION. REPAIRED THE FITTING IAW EA 011-5340-01-A6687 REV I/R, AND EO MD11-5340-63475-A.SDR AALA20170224027Attach Angle · crackedCRACKED PULLEY ATTACH ANGLE ON FORWARD SIDE OF FRAME BS 246, RBL 11. REPLACED THE ATTACH ANGLE PER SRM 53-10-51-2R-3 AND EA 267806.SDR AALA20170224025Attach Angle · crackedCRACKED PULLEY ATTACH ANGLE ON FORWARD SIDE OF FRAME BS 246, LBL 4. REPLACED THE ATTACH ANGLE IAW SRM 53-10-51-2R-3 AND EA 267806.SDR AALA20170224023Attach Angle · crackedCRACKED PULLEY ATTACH ANGLE ON FORWARD SIDE OF FRAME BS 246 AND RBL 6. REPLACED THE ATTACH ANGLE IAW SRM 53-10-51-2R-3 AND EA 267806.SDR AALA20170224022Attach Angle · crackedCRACK ON PULLEY ATTACH ANGLE ON FORWARD SIDE OF FRAME AT BS 246, BL 0. REPLACED THE ATTACH ANGLE IAW SRM 53-10-51-2R3 AND EA 267806.SDR IXXA20170320174Fitting · corrodedLEFT MLG WW, FORWARD SHEAR LINK FITTING IS CORRODED. REMOVED AND REPLACED SHEAR LINK ASSEMBLY.SDR ASAA2017022319995Stringer Clip · crackedFOUND STRINGER CLIP CRACKED BS 500K, STRINGER 26L. ACFT GROUNDED. REMOVED AND REPLACED THE STRINGER CLIP IAW SRM 51-40-02 AND DWG 143A1261 REV-.SDR ASAA2017022319993Stringer Clip · crackedSTRINGER CLIP CRACKED BS 500L, STRINGER 26L. ACFT GROUNDED. REMOVED AND REPLACED THE STRINGER CLIP IAW SRM 51-40-02 AND DWG 143A1262, REV-.SDR FDEA201702230640Pan · crackedE & E BAY. EXTERNAL GROUND POWER RECEPTACLE PAN HAD TWO UPPER RECEPTACLE FITTING MOUNT HOLES CRACKED. REMOVED AND REPLACED THE EXTERNAL GROUND POWER RECEPTACLE PAN, COMPLIED WITH EA F-5240-T0331639 P1. THIS IS A MAJOR REPAIR.SDR HALA2017022400064Fitting · corrodedDURING H CHECK, EIGHT FLIGHT ATTENDANT SEAT HARD POINTS FORWARD OF FRAME 17 BETWEEN -Y1456 AND -Y1959 FOUND CORRODED. REPLACED CENTER HARD POINT FITTING, IAW SRM 51-42-11 REV 92 DRAWING F2531071300 AND F25310721000.SDR REXA2017022200288Attach Angle · corrodedATTACH ANGLE AT BS 280 AND LBL 12 HAS CORROSION. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-42-06, AND SRM 51-42-10.SDR AALA201703239008Bushing · migratedMIGRATED BUSHING ON LEFT MAIN LANDING GEAR DOOR ACTUATOR ATTACH POINT KEEL BEAM, IN AFT LUG AT FRAME 42 BETWEEN STRINGER 41 AND 42L. REPLACED FITTING IAW EA 261038.SDR AALA201703229003Bushing · migratedMIGRATED BUSHING ON LEFT MAIN LANDING GEAR DOOR ACTUATOR, UPPER ATTACH POINT ON KEEL BEAM, FORWARD LUG AT FRAME 42 BETWEEN STRINGERS 41 AND 42L. REPLACED FITTING IAW EA 261038.SDR IPXA2017030114556Stiffener · crackedINSPECTION TYPE: C10, CRACK ON CENTER WING FRONT SPAR STIFFENER UPPER SIDE AT BS 785.9, RBL 33. REPAIR IAW SRM 57-10-10-2R-2, REPAIR 2, REV.67, AND EO B767-5740-58151-A.SDR SWAA2017022812187Attach Angle · corrodedL1 DOOR GIRT BAR ATTACH ANGLE CORRODED AT BS. 344, LBL 62. R & R ATTACH ANGLE IAW SRM.SDR IPXA2017031215012Intercostal · crackedINSPECTION TYPE: 3C, RT MLG WW UPPER CENTER ACCUMULATOR INTERCOSTAL IS CRACKED. REPAIRED THE INTERCOSTAL IAW SRM 53-40-12, REPAIR 3, FIG. 201.(MAJOR)SDR IPXA2017030714836Fitting · corrodedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING NR 6 HAS CORROSION. REPAIRED THE FITTTING IAW EA 011-5340-01-A6672 AND EO MD11-5340-63398-A.SDR IPXA2017030714835Fitting · corrodedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING NR 8 HAS CORROSION. REPAIRED THE FITTING IAW EA 011-5340-01-A6674 REV I/R, AND EO MD11-5340-63424-A.SDR IPXA2017022814515Fitting · corrodedINSPECTION TYPE:2CRIGID CARGO BARRIER FLOOR FITTING AT POS. #5 HAS CORROSION.REMOVED AND REPLACED RIGID CARGO BARRIER FLOOR FITTING AT POS. #5 IAW DWG. SP11250221 AND SRM 53-20-50.SDR IPXA2017022814514Fitting · corrodedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING AT NR 2 HAS CORROSION. REMOVED AND REPLACED THE FITTING IAW DWG SP11250221, AND SRM 53-20-50.SDR IPXA2017022814513Fitting · corrodedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING NR 4 HAS CORROSION ON BOTTOM SURFACE. REMOVED AND REPLACED THE FITTING IAW DWG SP11250221 AND SRM 53-20-50.SDR IPXA2017022814512Fitting · corrodedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING HAS CORROSION ON BOTTOM SURFACE.REMOVED AND REPLACED RIGID CARGO BARRIER FLOOR FITTING IAW DWG SP11250221, AND SRM 53-20-50, REPAIR 1 .SDR REXA2017021700267Attach Angle · corrodedATTACH ANGLE AT BS 280 AND RBL12 IS CORRODED. REMOVED & REPLACED THE ATTACH ANGLE IAW SRM 51-42-06, & 51-42-13.SDR SWAA2017030112214Bracket · crackedKEEL BEAM SUPPORT BRACKET CRACKED AT BS 540+2, LBL 5. R & R BRACKET IAW SRM.SDR R61A201702170139Mount · corrodedCORROSION WAS FOUND ON OTBD AFT MOUNTING PLATE AFT GALLEY. THE MOUNT WAS REMOVED AND REPLACED IAW SRM 25-33-81.CHECK COMPLITON.SDR CALA2017021700405Tee Fitting · corrodedLEFT EMERGENCY EXIT DOOR LOWER CUTOUT AFT AND FWD SKIN CORRODED ON INNER SKIN AT ATTACH POINTS. REMOVED AND REPLACED THE TEE FITTINGS IAW SRM 51-42-11.SDR ABXA2017215016Tee Fitting · corrodedKEEL BEAM INTERCOSTAL HAS CORROSION AT BS 960. REMOVED AND REPLACED INTERCOSTAL TEE IAW SRM 51-40-02. AIRCRAFT WAS GROUNDED.SDR ABXA20170215015Tee Fitting · corrodedKEEL BEAM INTERCOSTAL HAS CORROSION AT BS 866. REMOVED AND REPLACED INTERCOSTAL TEE IAW SRM 51-40-02. AIRCRAFT WAS GROUNDED.SDR ABXA2017215014Tee Fitting · corrodedKEEL BEAM INTERCOSTAL HAS MISSING NUT PLATE AND CORROSION. REMOVED AND REPLACED INTERCOSTAL TEE IAW SRM 51-40-02.SDR SWAA2017022211948Stringer Clip · crackedSTRINGER 24L CLIP CRACKED AT BS 277. R & R THE STRINGER CLIP IAW SRM.SDR DALA2017021501262Mount · corrodedFWD CABIN WET AREA LT SIDE AT BS 333 LBL 20 LAVATORY MOUNT HAS CORROSION. REPAIRED IAW DRAWING 27751SM007 REV. D.SDR DALA2017021501261Mount · corrodedFWD CABIN WET AREA LT SIDE AT BS 333 LBL 20 LAVATORY MOUNT HAS CORROSION. REPAIRED IAW DRAWING 27751SM007 REV. D.SDR IPXA2017021414044Attach Bracket · crackedINSPECTION TYPE: C1, AFT CARGO BAY FWD BULKHEAD ATTACH ANGLE AT BL 0 CRACKED. REMOVED & REPLACED THE ATTACH ANGLESDR ASOA201702141208Stringer Clip · corrodedDURING C CHECK, FOUND STRINGER CLIP CORRODED. R & R THE STRINGER CLIP.SDR A6WA2017021544797Bracket · crackedSTANDOFF BRACKET AT 8 O'CLOCK POSITION ON LH ENGINE NOSE INLET COWL IS CRACKEDSDR IPXA2017030814883Fitting · crackedINSPECTION TYPE: 2C, RIGID CARGO BARRIER FLOOR FITTING NR 1 IS CRACKED. REMOVED AND REPLACED THE FITTING IAW EO MD11-2520-58701-D.SDR R61A201702210162Fitting · corrodedCORROSION ON THE INBD RT WINDSCREEN TIE DOWN FITTING BETWEEN FRAMES 17 AND 18 REMOVED AND INSTALLED A NEW TIE DOWN FITTING IAW SRM 51-40-02.SDR R61A201702210159Fitting · corrodedCORROSION ON FWD LAVATORY TIE DOWN FITTING AT FRAME 16. REMOVED AND REPLACED THE FITTING IAW SRM 51-43-03.SDR R61A201702200148Retainer · corrodedCORROSION ON WASTE SERVICE BOX FWD RETAINER. REMOVED AND REPLACED THE RETAINERS IAW EO-53-10-0020.SDR IPXA2017030114587Fitting · chafedINSPECTION TYPE: 3C, RIGID CARGO BARRIER SIDE FITTING NR13 HAS CHAFE DAMAGE. REPAIRED THE SIDE FITTING IAW EA 011-5340-01-A6647 REV. I/R, AND EO MD11-5340-63309-A.SDR QMLA2017020617018Bracket · crackedSEVERAL CRACKS HAVE BEEN FOUND ON AN AN BRACKET ATTACHED TO THE AIRCRAFT COCKPIT AND FUSELAGE. FIRST CRACK WAS ON THE LT JUST AFT OF THE GREENHOUSE WINDOW AT BS 2049.5, WL 1550-1400, LBL 125 AND MEASURED 3.5 INCHES. THE SECOND CRACK WAS LOCATED ON THE RT SIDE SDR ASAA2017020619792Tee Fitting · corrodedAFT CARGO FLOOR TEE ASSY AT BS 727D IS CORRODED. ACFT GROUNDED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2.
Back to JASC 5340