JASC 5340
Service difficulty reports · 22,407
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR A6WA201643749Mount Bracket · crackedSYSTEM 3 ACCUMULATOR FWD OTBD MOUNT BRACKET IS CRACKED. REPLACED SYS 3 OTBD MOUNT BRACKET WITH NEW PART IAW SRM 51-42-21.SDR SWAA2016041350859Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 277, STRINGER 15R. R & R CLIP IAW SRM & DWG.SDR IPXA2016040101485Attach Angle · crackedINSPECTION TYPE:5YR, AFT CARGO COMPARTMENT, FWD BULKHEAD, PANEL ATTACH ANGLE CRACKED FRAME 54, RBL 77, WL-Z192. REMOVED CRACKED ANGLE, INSTALLED NEW BRACKET IAW DWG A53410123.SDR SWAA2016040150769Stringer Clip · corrodedSTRINGER CLIP CORRODED AT BS 951.5, STRINGER 20R. R & R CLIP IAW SRM & DWG.SDR SWAA2016040550616Stringer Clip · corrodedAFT CARGO BAY STRINGER CLIP CORRODED AT BS 947.5, STRINGER 27R. R & R CLIP IAW SRM.SDR SWAA2016040550615Stringer Clip · corrodedAFT CARGO BAY STRINGER CLIP CORRODED AT BS 947.5, STRINGER 27L. R & R CLIP IAW SRM.SDR AALA201603299009Plate · crackedAIRCRAFT IN BASE MX. RT KEEL BEAM CONNECTING PLATE CRACKED AT FRAME 42 & STRINGER 36 RT. REPLACED CONNECTING PLATE IAW SRM 53-36-11 & DWG D53370682.SDR IPXA2016041802303Fitting · corrodedINSPECTION TYPE:2C, RCB FLOOR FITTING HAS CORROSION ALONG UPPER EDGES. ACCOMPLISHED BLEND REPAIR ON RCB FLOOR FITTING BS 488 X=8.5 IAW EA 011-5310-01-A6203, REV I/R AND EO MD11-5340-60492-A.SDR IPXA2016041802318Fitting · damagedINSPECTION TYPE:C2, RIGID CARGO BARRIER FLOOR FITTING NR 8 HAS AREAS OF EDGE DAMAGE. REPAIRED DAMAGED RCB FLOOR FITTING NR 8 IAW EA 011-5310-01-A6205, REV A AND EO MD11-5340-60491-A.SDR IPXA2016041802316Fitting · corrodedINSPECTION TYPE:2C, RCB FLOOR FITTING HAS CORROSION ALONG UPPER EDGES. ACCOMPLISHED BLEND REPAIR ON RCB FLOOR FITTING BS 488 X=27.5 IAW 011-5310-01-A6203, REV I/R AND EO MD11-5340-60492-A.SDR IPXA2016041802314Fitting · corrodedINSPECTION TYPE:C2, RIGID CARGO BARRIER FLOOR FITTING NR 7 HAS AREAS OF CORROSION ALONG UPPER EDGES. REPAIRED CORRODED RCB FLOOR FITTING NR 7 IAW EA 011-5310-01-A6205 REV A AND EO MD11-5340-60491-A.SDR IPXA2016041802304Fitting · corrodedINSPECTION TYPE:C2, RIGID CARGO BARRIER FLOOR FITTING NR 6 HAS AREAS OF CORROSION ON UPPER EDGES. REPAIRED CORRODED RCB FLOOR FITTING NR 6 IAW EA 011-5310-A6205, REV A AND EO 5340-60491-A.SDR REXA2016032500488Mount Bracket · crackedNUMBER 1HYD ACM PUMP CASE DRAIN FILTER MOUNT BRACKET IS CRACKED. R & R PUMP CASE DRAIN FILLER MOUNT BRACKET IAW SRM 51-42-06 & 51-24-24.SDR IPXA2016041802313Bracket · crackedINSPECTION TYPE:C2, FORWARD CARGO UPPER OTBD PNEUMATIC DUCT BRACKET IN LT TUNNEL IS CRACKED BS 715. REPAIRED CRACKED PNEUMATIC BRACKET LT TUNNEL AT BS 715 IAW EA 011-3600-01-A6202, REV I/R AND EO MD11-3600-60482-A.SDR IPXA2016041802266Bracket · crackedINSPECTION TYPE:C2, FWD CARGO UPPER OTBD PNEUMATIC DUCT BRACKET IN LT TUNNEL IS CRACKED AT BS 715. REPAIRED CRACKED PNEUMATIC BRACKET LT TUNNEL AT BS 715 IAW EA 011-3600-01-A6202, REV I/R AND EO MD11-3600-60482-A.SDR SWAA2016040150527Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 727D, STRINGER 15L. R & R CLIP IAW SRM & DWG.SDR REXA2016032200463Stringer Clip · crackedPASSENGER CABIN STATION 280, BULKHEAD AFT SISW STRINGER 3L, CLIP IS CRACKED. R & R CLIPS WITH NEW CLIPS IAW 51-42-06.SDR QMLA2016032116025Support Frame · chafedTHE TRANSMISSION SUPPORT FRAME, PN 350A21-1041-143, HAS CHAFING DAMAGE ON THE LOWER FLANGE FROM AN UNSECURED CABLE, PN 704A34-1302-23. PN 350A38-1040-20 ATTACHES TO PN 350A21-1041-143.SDR AALA20160323004Attach Fitting · crackedAIRCRAFT WAS IN BASE MX. KEEL BEAM ACCESS PANEL 192E RT ATTACH FITTING IS CRACKED. R & R FITTING IAW SRM 51-10-02-0G PARA 9.SDR AALA20160320001Attach Fitting · crackedAIRCRAFT WAS IN BASE MX. KEEL BEAM ACCESS PANEL 192E LT ATTACH FITTING IS CRACKED. R & R FITTING IAW SRM 51-10-02-0G PARA 9.SDR LR7A2016031700770Fitting · crackedDURING SCHEDULED A-1 INSPECTION, FOUND FUSELAGE FITTING CRACKED, FS477.0, RBL61.62, WL146.0. REPAIR BY REPLACEMENT ACCOMPLSIHED IAW LM DWG 339394 AND MEA 382-53-16-010.SDR SWAA2016040150487Stringer Clip · corrodedSTRINGER CLIP CORRODED AT BS 887, STRINGER 22L. R & R CLIP IAW SRM & DWG.SDR WVER2016031591114Fitting · damagedWHILE LOCATING HOLES IN STR 13L, FITTING IAW S/B 670BA-53-044, PART A, REV C, FOUND THREE FASTENER HOLES WILL BE LOCATED NEAR MILLED RADIUS OF FITTING.SDR SWAA2016032450185Stringer Clip · crackedSTRINGER CLIP CRACKED AT STATION 827, STRINGER 16R. R & R CLIP IAW SRM.SDR SWAA2016042151158Stringer Clip · corrodedSTRINGER CLIP CORRODED AT BS 967, RBL 5. R & R CLIP IAW SRM.SDR SWAA2016041851001Stringer Clip · corrodedSTRINGER CLIP CORRODED AT BS 947, STRINGER 18R. R & R CLIP IAW SRM.SDR SWAA2016041851000Stringer Clip · corrodedSTRINGER CLIP CORRODED AT BS 967, STRINGER 20R. R & R CLIP IAW SRM.SDR DALA2016031201884Fitting · corrodedCORROSION ON FITTING, 2EA OF FLOOR PANEL 160G, LATCH GIRT BAR. FITTINGS WERE REPLACED NEW, 2 EA WERE ADJUSTED IAW SRM 51-10-4.SDR IPXA2016033001393Fitting · crackedINSPECTION TYPE:3C, CENTER LOWER AUXILIARY FUEL TANK ANGLE FITTING CRACKED AT BS 1278 BETWEEN L42L AND L43L. R & R CENTER LOWER AUXILIARY FUEL TANK ANGLE FITTING IAW SRM 51-33-01 AND 51-35-01.SDR UHLA201603100138Bracket · corrodedCORROSION ON BRACKET AT FRAME 87 BETWEEN STR 27 AND 28R. R & R BRACKET FRAME 87, FWD 3", BETWEEN S27R AND S28R. MAJOR REPAIRSDR DALA2016031401936Pad · corrodedFORWARD LAVATORY ASSY, AFT INBD MOUNT PAD CORRODED. REMOVED AND INSTALLED FLOOR MOUNT IAW CMM AND PRI ERA 544507-14, REV O.SDR DALA2016031401935Pad · corrodedFORWARD LAVATORY ASSY, AFT OTBD MOUNT PAD CORRODED. REMOVED AND INSTALLED FITTING IAW CMM AND PRI/ERA 544507-14, REV O.SDR DALA2016031101873Lug · crackedCRACK ON LUG WYE DUCT. LUG ON WYE DUCT WAS WELDED IAW ER/A 494638-14MA, REV B.SDR DALA2016031101850Angle · crackedCRACKED INTERCOSTAL ANGLE ON BS 674 BETWEEN EDGE AND BEAM 1 AT MID CARGO COMPARTMENT DOOR. CRACKED INSTERCOSTAL ANGLE WAS REPLACED IAW SRM 51-30-2 AND 51-3-5.SDR IPXA2016040501698Fitting · corrodedINSPECTION TYPE:3C, RCB WALL FLOOR FITTING NR 5 HAS CORROSION ON UPPPER AND LOWER SURFACE. PERFORMED BLEND REPAIR ON RCB WALL FLOOR FITTING NR 5 IAW EA 011-5310-01-A6175 REV I/R AND EO 5340-60352-A.SDR IPXA2016040501697Fitting · corrodedINSPECTION TYPE:3C, RCB WALL FLOOR FITTING NR 4 HAS CORROSION ON LOWER SURFACE. PERFORMED BLEND REPAIR ON RCB WALL FLOOR FITTING NR 4 LOWER SURFACE IAW EA 011-5310-01-A6175, REV I/R AND EO MD11-5340-60352-A.SDR IPXA2016040601725Fitting · corrodedINSPECTION TYPE:3C, RCB FLOOR FITTING NR 8 HAS CORROSION ON TOP FLANGE BS 488 X= - 47.5. ACCOMPLISHED BLEND REPAIR ON RCB FLOOR FITTING NR 8 BS 488 X=-47.5 IAW EA 011-5310-01-A6176 REV I/R AND EO 5340-60281-A.SDR IPXA2016040501699Fitting · gougedINSPECTION TYPE:3C, RCB FLOOR FITTING NR 6 HAS CORROSION ON UPPPER AND LOWER SURFACE, PERFORMED BLEND REPAIR ON RCB FLOOR FITTING NR 6 UPPER AND LOWER SURFACE IAW EA 011-5310-01-A6175, REV I/R AND EO MD11-5340-60352-A.SDR ABXA20160309044Fitting · corrodedLEFT WW FWD SPAR KICK FITTING HAS 2 EACH FASTENER HOLES CORRODED. REPAIRED CORRODED HOLES IAW REA B657-61967 MR. SDR INFO CORRODED LEVEL 2, PN 112T1219-7, PART NAME KICK LOAD FITTING, SN NSN, FS & BS FROM 955, STRINGER & WS FROM CTR FUSE I CTR WING. ACFT WASSDR ASAA2016030916153Stringer Clip · corrodedAFT CARGO PIT SHEAR TIE CLIP IS CORRODED AROUND FASTENER AT BS 767, STR 26L. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMITS, FOUND SHEAR TIE CLIP, STRINGER TIE, OUT OF LIMITS IAW SRM 53-00-07-1A-1, FIG 101, DETAIL II. R & R STR TIE, SHEAR TIE CLIP, IAWSDR QMLA2016030916024Support Frame · chafedTHE TRANSMISSION SUPPORT FRAME, PN 350A21-1041-143, HAS CHAFING DAMAGE ON THE LOWER FLANGE, FROM AN UNSECURED CABLE, PN 704A34-1302-23. PN 350A38-1040-20 ATTACHES TO PN 350A21-1041-143.SDR R61A201603080303Attach Angle · corrodedDURING HEAVY CHECK, ATTACH ANGLE AT STR 19 RT FRAME 87 IS CORRODED. MAINTENANCE R & R ATTACH ANGLE AT STR 19 RT, FRAME 87 IAW SRM 51-43-03, 51-23-06, PN 170-85486-002, ANGLE.SDR IPXA2016040901864Nut Plate · brokenINSPECTION TYPE:3 CONE BROKEN NUTPLATE INSIDE RCB BASE RECTIFIED BROKEN NUTPLATE CONDITION EA 011-5310-01-A6142, REV IR AND EO MD11-5320-60382-A.SDR SWAA2016040850710Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 277, STRINGER 11R. R & R CLIP IAW SRM & DWG.SDR SWAA2016040650649Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 440, STRINGER 8L. R & R CLIP IAW EA.SDR SWAA2016040450589Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 400, STRINGER 8L. R & R CLIP IAW EA.SDR ABXA20160308045Fitting · damagedLEFT SIDE FRAME FITTING HAS AN EXISTING OVERSIZED HOLE WITH A BUSHING COMMON TO THE KICK FITTING. SIDE FRAME FITTING OVERSIZED HOLES WERE REPAIRED IAW REA B653-61969 MR. SDR INFO CORRODED LEVEL 2, PN 145T2523-5, PART NAME SIDE FRAME FITTING, SN NSN, FS & BS SDR SWAA2016032850248Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 360, STRINGER 8R. R & R CLIP IAW EA.SDR R61A201603080216Attach Angle · corrodedDURING HEAVY CHECK WAS REPORTED THAT ATTACH ANGLE AT STRINGER 19 RT FRAME 87 IS CORRODED. MAINTENANCE R & R ATTACH ANGLE AT STRINGER 19 RT FRAME 87 IAW SRM 51-40-02, 51-23-04, PN 170-85486-002 ANGLE.SDR IPXA2016040701786Fitting · damagedINSPECTION TYPE:C3, RIGID CARGO BARRIER SIDE FITTING NR 1 HAS HEAVY WEAR/CHAFE DAMAGE. REPAIRED RIGID CARGO BARRIER SIDE FITTING NR 1 IAW EA 011-5310-01-A6172, REV I/R AND EO MD11-5340-60398-A.
Back to JASC 5340