JASC 5340
Service difficulty reports · 22,405
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202312116872Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND LBL 6.14. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR AALA202312119696Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND RBL 6.14. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR AALA202312119909Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND RBL 15.04. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR AALA202312116529Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND RBL 32.40. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR AALA202312113934Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND RBL 40.87. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR AALA202312111611Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND RBL 54.60. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR DALA2023120810072Unknown · unknown(LOG 0097438) A/C RAIL BRACKETS STA 907RH CRACK DETECTED IN FRAME AT FASTENER HOLE. A/C RAIL BRACKETS STA 907RH, FRAME WAS REPAIRED I.A.W. B737-800 WORKCARDSDR DALA2023120810071Unknown · unknown(LOG 0097423) A/C RAIL BRACKETS STA 907LH CRACK DETECTED IN FRAME AT FASTENER HOLE. A/C RAIL BRACKETS STA 907LH, FRAME WAS REPAIRED I.A.W. B737-800 WORKCARD 2526-01236-03A.SDR SWAA2024011628023Bracket · crackedCRACK ON SUPPORT BRACKET LOCATED BTW BS 540 TO BS 559 AIR CONDITIONING BAY LT SIDE 2023-751566<[01] REPLACED SUPPORT BRACKET LOCATED BTW BS 540 TO BS 559 AIR CONDITIONING BAY LT SIDE IAW B737-800 SRM 51-40-02-0G-0;[02] REPLACED SUPPORT BRACKET LOCATED BTW BS 5SDR HNAA2023122800537Unknown · unknown53-2264 CORROSION ON CARGO DOOR ENTY TEE LOWER AT FR68. R&R'D IAW SRM 51-40-02SDR SWAA2023122027951Attach Angle · crackedR/H BS663 UPPER ATTACH ANGLE IS CRACKED ON VAPOR BARRIER RBL8 WL167.68<[01] CRACK WAS FOUND TO BE OUT OF LIMITS REMOVED DAMAGED SECTION OF ANGLE AND INSTALLED REPAIR AS PER SRM 57-10-10-2R-5.;[02] VERIFIED CORRRECTIVE ACTION 1 AND MEASUREMENT TABLESDR DALA2023120810081Unknown · unknown(LOG 0099843) A/C RAIL BRACKETS STA 827 RH CRACK DETECTED IN FRAME AT FASTENER HOLE. A/C RAIL BRACKETS STA 827 RH, FRAME WAS REPAIRED I.A.W. B737-800 WORKCARD 2526-01236-02B.SDR DALA2023120810080Unknown · unknown(LOG 0100104) A/C RAIL BRACKETS STA 500C RH CRACK DETECTED IN FRAME AT FASTENER HOLE. A/C RAIL BRACKETS STA 500C RH, FRAME WAS REPAIRED I.A.W. B737-800 WORKCARD 2526-01236-02B.SDR DALA2023120810079Unknown · unknown(LOG 0100086) A/C RAIL BRACKETS STA 727B RH CRACK DETECTED IN FRAME AT FASTENER HOLE. A/C RAIL BRACKETS STA 727B RH, FRAME WAS REPAIRED I.A.W. B737-800 WORKCARD 2526-01236-02B.SDR CALA2023120503563Stringer Clip · corrodedSTRINGER CLIP ON STR 16R AT STA 1285 HAS CORROSION FLAGGED.SDR AALA202312063497Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE AT BS 663.5, LBL 8. REPLACED ATTACH ANGLE PER AARD 51-00-05.SDR VNAA2023120320022Fitting · corrodedHN 118817 DISCREPANCY: FITTING AT FLOOR LEVEL AT FS349 PN SH670-31981-1 HAS MINOR CORROSION AT FLOOR BOARD LEVEL CORRECTIVE ACTION: REMOVED FITTING AT FLOOR LEVEL AT F.S.349 PN SH670-31981-1 IAW CRJ-900 SRM 51-42-21-001-001 (A01). INSTALLED NEW SERVICEABLE LOWSDR SWAA2023122128505Tee Angle · crackedT-CLIP P/N 149A7627-5 COMMON TO BS 663 VAPOR BARRIER WL 150 LBL 25 IS CRACKED<[01] REMOVED AND REPLACED PER REF SRM 51-40-02 AND DWG 111A7000;[02] VERIFIED CORRECTIVE ACTIONS STEP 1 AND MEASUREMENTS TABLE.SDR VNAA20231130007Bolt · corrodedHN00115399 DISCREPANCY: DESCRIPTION: FLAP PDU REQUIRES REMOVAL FOR ACCESS FOR STRUCTURE REPAIRS. CORRECTIVE ACTION: FLAP PDU ATTACHING HARDWARE FOUND TO BE CORRODED AND REQUIRES REPLACEMENT. NEW SERVICEABLE HARDWARE INSTALLED IAW CRJ 700 AMM 27-52-37-400-801-ASDR HNAA2024011700027Bracket · chafedE011804 LWR EXTERIOR FUSELAGE R/H OUTBD BRACKET BETWEEN FR-52-53 AT STGR 19R IS CHAFED. ACCOMPISHED STRINGER SPLICE REPAIR ON LWR EXTERIOR FUSELAGE R/H OUTBD STRINGER (BRACKET) BETWEEN FR 52-53 AT STR 19R IAW EMB 145 SRM 53-24-02-RE, STEP 2, FIGURE 201 AND EOSDR CALA2023120803601Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND LBL 15.04 IS CRACKED SUPPORT TASK NSA EMX NR 00093 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND LBL DATA WAS TRANSCRIBED FROM NSA EMX N/R 00093, AND HANGAR 15.04 IAW 5737-800 SRM 51--40-02 AND BAC DWG 11SDR CALA2023120803597Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND RBL 15.04 IS CRACKED SUPPORT TASK NSA EMX NR 00094 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL DATA WAS TRANSCRIBED FROM NSA EMX N/R 00094 AND HANAGR N/R 15.04 IAW B737-800 SRM 51--40-02 AND BAC DWGSDR YENA2023113001518Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH INTERCOSTAL FITTING AT OPEN FASTENER H OLE H1, CRACK DIRECTION IS 5 OCLOCK, AT DOOR STOP FITTING 7 POSITION, AT FWD GALLEY AREA (1 EA); REF AEROMAN N/R 2023- 631069, PERFORMED REPAIR FR16LH AT LEVEL DOOSDR YENA2023113001517Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH INTERCOSTAL FITTING AT OPEN FASTENER H OLE H3, CRACK DIRECTION IS 5 OCLOCK, AT DOOR STOP FITTING 7 POSITION, AT FWD GALLEY AREA (1 EA); REF AEROMAN N/R 2023- 631070, PERFORMED REPAIR FR16LH AT LEVEL DOOSDR YENA2023113001516Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 RH INTERCOSTAL FITTING AT OPEN FASTENER H OLE H3, CRACK DIRECTION IS 10 OCLOCK, AT DOOR STOP FITTING 7 POSITION, AT FWD GALLEY AREA (1 EA); PERFORMED REPAIR FR16RH AT LEVEL DOOR STOP FITTING #7 HOLE 3. IAWSDR SWI2024F00030Cleat · corroded1 EA CLEAT ON FRAME 313.56 AND DD4 IS CORRODED (C-CHECK RO 1/24/2024) INSTALLED NEW PAX DOOR 1 EA CLEAT ON FRAME 313.56 AND DD4 . REF: CRJ-700 SRM 51-42-06-001-001-A01 AND DRAWING 601R31702 REV N. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA2024012500125Cleat · corroded2 EA CLEATS @ FS320.00 AND BOTTOM CHANNEL ARE CORRODED (C-CHECK RO 1/24/2024) INSTALLED NEW PAX DOOR 2 EA CLEATS @ FS320.00 AND BOTTOM CHANNEL . REF: CRJ-700 SRM 51-42-06-001-001-A01 AND DRAWING 601R31702 REV N. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR AALA202312121204Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING AT FR 16 RIGHT AND #7 DOOR STOP FITTING. REPLACED INTERCOSTAL FITTING PER SRM 51-42-11.SDR SWAA2023121123814Bracket · crackedBRACKET CRACKED AT BS 867 STR 3R<[01] REMOVED FLOOR PANEL 321UF PER AMM 53-21-00-000-801;[02] EDIT: ACTION ENTERED IN ERROR; WRONG TASK;[03] COMPLETED STEP 1. CARD COMPLETED;[04] VERIFIED COMPLETE STEP 3; MEASUREMENTS TABLE OK; CARD COMPLETE.SDR REXA2024010800037Bracket · crackedWIRE HARNESS BRACKET IS BENT AND APPEARS TO BE CRACKED AT RBL 36 BETWEEN F.S. 744 TO F.S. 752. REMOVED BENT AND CRACKED WIRE HARNESS BRACKET AT RBL 36 BETWEEN F.S. 744 AND F.S. 752 AND INSTALLED REPLACEMENT WIRE HARNESS BRACKET IAW CRJ 900 SRM TASK 51-42-06-00SDR SWAA2024010423407Support Angle · crackedCRACK ANGLE SUPPORT LOCATED STA 727B AND LBL51 CEILING AREA AFT CARGO COMPARTMENT 2023-719787<[01] PERFORMED PERMANENT REPAIR ON ANGLE SUPPORT LOCATED STA 727B AND LBL51 CEILING AREA AFT CARGO COMPARTMENT IAW B737-800 SRM 51-70-11-2R-0 REPAIR GENERAL. SEE INDISDR REXA2023112000991Bracket · corrodedLH MLG WHEEL WELL HYDRAULIC INTERFACE BRACKET (LOWER) CORRODED AT APPROX LBL45 AND FS797 REMOVED CORRODED L/H MLG WHEEL WELL HYDRAULIC LINE INTERFACE BRACKET AND INSTALLED NEW SERVICABLE BRACKET IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR SWI2024F00023Cleat · corrodedCLEAT @ FS320.00 AND DD1A IS CORRODED (C-CHECK RO 1/24/2024) INSTALLED NEW PAX DOOR CLEAT @ FS320.00 AND DD1A . REF: CRJ-700 SRM 51-42-06-001-001-A01 AND DRAWING 601R31702 REV N. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR A6WA202311178675Cleat · corroded471 20103 330500 MFG 427-680-100 3 HRS LH UPPER FLOOR SKIN AND SILL HAVE NUMEROUS AREAS OF CORROSION BETWEEN FS339-FS259. ***** AIRCRAFT REMOVED FROM SERVICE ***** REMOVED AND REPLACED 1EA CLEAT P/N 601R31527-176, 1EA BRACKET ASSY P/N 601R31527-217 ON PASSDR GTIA2023112137627Fitting · corrodedCORROSION FOUND ON FWD CARGO AFT CUTOUT FR 28 FITTING STR 37R-39R MEASURING 1.54"L .836"W .075"D. RAF 01 CREATED. SDR SUBMITTED-ACCOMPLISHED REPLACEMENT AND BUSH REPAIR PER A320 SRM 51-72-11-911-002, 53-21-29-04 RDAF 81309453/003/2024 A REF EA 5321-2392 ON FWDSDR SWIA2024012500115Attach Angle · corrodedPANEL 642AZ, IN RH MLG WELL, FORWARD ATTACH ANGLE ON THE AFT WING SPAR IS CORRODED (MARKED) (C-CHECK RO 1/24/2024) REMOVED AND INSTALLED 1EA NEW ATTACHING ANGLE AT PANEL 642AZ PER CRJ700SRM 51-42-21-001-001-A01 AND DWG CC670-10320 REV-F. COMPLIED WITH SKYSDR SWIA2024012531114Attach Angle · corrodedPANEL 542AZ FORWARD ATTACH ANGLE ON THE AFT WING SPAR, IN THE LH MLG WELL, IS CORRODED (MARKED) (C-CHECK RO 1/24/2024) REMOVED AND INSTALLED 1EA NEW ATTACHING ANGLE AT PANEL 542AZ PER CRJ700SRM 51-42-21-001-001-A01 AND DWG CC670-10320 REV-F. COMPLIED WITHSDR SBOY202312080002Unknown · unknownSTA 1000 RBL 11.33 INTERCOASTAL LUG FITTING FOUND CRACKED DURING AD INSPECTION, REFERENCES: (FAA AD 2021-17-06) SB 747-53A2904. 9V-SFI B747FSDR SWAA2023112022018Bracket · crackedDOT#4 A-043 AFT CARGO COMPARTMENT VACUUM WASTE COMPARTMENT LEEK ANGLE CRACKED AT STA 867 LBL 10 WL 156<[01] REMOVED AFT CARGO COMPARTMENT ANGLE P/N: 149A8109-114 IAW B737 SRM 51-40-02-0G-0.;[02] VERIFIED NEW BRACKET P/N 149A810911A TAG# A213475 IAW IPC53-42-51SDR REXA2023112000983Nut Plate · corroded4 NUT-PLATES ARE CORRODED BETWEEN F.S. 661+16 TO F.S.661+32 BETWEEN STGR 26L AND 24R. INSTALLED 4 FASTENERS AND 1 RETAINER PLATE P/N SH670-39095-7 FROM F.S. 661+16 TO F.S. 661+32 BETWEEN STGR 26L TO STGR 24R IAW CRJ900 SRM 51-42-06-001-001-A01.SDR IPXA2023111343467Unknown · unknownR/H WTB, T-CHORD, STA 1240, FOUND EXFOLIATED CORROSION, BETWEEN RBL 57.50 T0 RBL 63 PERFORMED CUT OUT AT T-CHORD FROM BL0 TO RBL63 STA 1240 I.A.W SRM 51-70-12-OG AND SRM 51-10-02. VERIFIED T-CHORD AT STA 1240 FROM BL-0 TO RBL-63 HAS BEEN CUT OUT.SDR SWAA2023121420481Attach Angle · crackedMID CABIN; WING CENTER SECTION; CABLE INTERCOSTAL; O/B LOWER ATTACH ANGLE IS CRACKED AT BS 685+9; RBL 23; WL 203<[01] REMOVED AND REPLACED BRACKET ON MID CABIN; WING CENTER SECTION; CABLE INTERCOSTAL; O/B LOWER AT BS 685+9; RBL 23; WL 203 I.A.W SRM 51-40-02-0GSDR IPXA2023112819755Tee Angle · corrodedFAULT: WTB STRUCTURE - T-CHORD STA 1060 IS CORRODED BETWEEN LBL 20 TO LBL 30. INSTALLED T-CHORD SECTION I.A.W. B757-200 S.R.M. 51-40-02-OG. REVIEWEDSDR CALA2023112003440Fitting · out of roundLH FR4 SIDE POST UPPER ATTACHMENT CONNECTION FITTING REQUIRES REMOVAL TO FOM SEPERATION OF LAYERS FOR NDT INSPECTION. REINSTALLED LH FR4 SIDE POST UPPER ATTACHMENT CONNECTION FITTING IAW SRM 51-42-11-001 AND 51-72-11-911-001. NO FURTHER ACTION REQUIRED.SDR CALA2023111503378Bracket · corrodedAFT LOWER CARGO CORROSION FOUND AT THE CONNECTION OF THE DRAIN MAST STA 1405 BETWEEN STRINGERS S-36R AND S 35R REMOVED AND REPLACED BRACKET AT STA 1405 BETWEEN STRINGER 36R AN D 35R I/A/W SRM 51-40-02 PAR4 AND 7 AND INSTALLED DRAIN MAST I/A /W AMM 38-31-01-404SDR IPXA2023111319701Unknown · unknownWTB STRUCTURE - T-CHORD STA 1037.67 IS CORRODED BETWEEN LBL 20 TO LBL 65 REF. STEP 3 , WORK VERIFIED. REMOVED T-CHORD STA 1037.67 BETWEEN LBL 20 TO LBL 65 INSPECTED.SDR AALA202311299909Fitting · noneAIRCRAFT IN BASE MAINTENANCE: CENTER WING BOX FORWARD SPAR UPPER SHEAR FITTING LOCATED AT BS 540 AND LBL 54.60 REPLACEMENT REQUIRED PER BOEING SERVICE BULLETIN B737-57-1309. REPLACED SHEAR FITTING PER AARD 57-14-00-1 REPAIR 1.SDR SWAA2023121319072Attach Angle · brokenFWD CARGO COMPARTMENT L/H INTERCOSTAL ATTACH ANGLE BROKEN AT AFT SIDE OF STA 440 BELLOW 'Z' CHANNEL<[01] REMOVED AND REPLACED ATTACH ANGLE (PN: 143A7502U155 PO: 2013551) AT FWD CARGO COMPT L/H INTERCOSTAL AFT SIDE OF STA 440 BELOW Z-CHANNEL PER REF SRM 51-40-0SDR SWIA2024020231106Nut Plate · brokenPANEL #141 AL HAS SEIZED SCREW & BROKEN NUTPLATE (C-CHECK RO 2/1/2024) OK TO INSTALL KH 910266REMOVED AND REPLACED SCREW AND NUTPLATE ON PANEL 141 AL NUTPLATE IAW CRJ200 SRM 51-42-10, 51-45-00, AND CRJ 200 AMM 21-32-00.SDR SWAA2023121318676Attach Angle · brokenFWD CARGO COMPARTMENT L/H INTERCOSTAL ATTACH ANGLE BROKEN AT FWD SIDE OF STA 500G UNDER 'Z' CHANNEL<[01] REMOVED AND REPLACED FWD CARGO COMPARTMENT L/H INTERCOSTAL ATTACH ANGLE AT FWD SIDE OF STA 500G UNDER 'Z' CHANNEL PER REF SRM 51-40-02-0G-0;[02] VERIFIED N
Back to JASC 5340