SDR SWIA202053634Stringer Clip · corrodedCORROSION ON CLIP AT FS 310.00 STGR 20R. C-CHECK RO 10/22/2020. CLIP AT FS 310 STGR 20R CORRODED BEYOND LIMIT. REMOVED AND REPLACED, REF CRJ700 SRM AND DWG. COMPLIED WITH SKYWEST TASK CARD "STRUCTURAL MAJOR REPAIR" (RII).SDR SWIA202053406Bracket · corrodedRT WHEEL WELL FWD BRACKET CORRODED, MARKED. C-CHECK RO 10/16/2020. REMOVED AND REPLACED RT WHEEL WELL FWD BRACKET P/N CC670-85501-8, REF CRJ 700 SRM.SDR ASAA2020091793184Bearing · looseNLG RETRACT ACTUATOR SUPPORT FITTING SPHERICAL BEARING AND BEARING HOUSING LOOSE IN FITTING. GROUNDED-YES. REMOVED AND REPLACED NLG RETRACT ACTUATOR SUPPORT FITTING, PER B737 SRM 51-40-02 AND DWG 146A7650.SDR UIEA2020091001972Mount · damagedDURING PRE-FLIGHT WALK AROUND, FOUND PANEL P40 (APU REMOTE PANEL) DROOPING. REMOVED AND REPLACED 4 MOUNTING CLIPS ON PANEL P40, REF AMM 26-15-01. OPS CK GOOD, OK FOR SERVICE.SDR SWAA2021072014466Attach Angle · bentAFT SHIELD HAS BENT ATTACH ANGLE AT FWD CARGO BAY BS500A RBL25 WL157. / FABRICATED NEW FCB AFT SHIELD ATTACH ANGLE BS500A RBL-25 WL-157 MADE FROM BAC1503 - 100179 7075-T6511 LOT# 1442201-2 EXTRUSION IAW SRM 51-40-05 AND DWG # 143A8124 SENT TO OSS FOR HEAT TREASDR SWAA2021071414444Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS400 RBL25 WL156. / REMOVED AND REPLACED ON INTERCOSTAL ATTACH ANGLE AT FCB BS 400 RBL 25 NEW P/N 143A7502-156 PO# 802611. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 143A7505 80641U 14SEPT20SDR SWAA2020092814447Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS 500C FWD SIDE RBL 25 WL 156. REMOVED AND REPLACED NEW ON INTERCOSTAL ATTACH ANGLE AT FCB BS 500C RBL 25 P/N 143A7502U160 PO NR 802622. LOCATED AND DRILLED, IAW SRM 51-40-05; SRM 51-40-02 AND DWG 143A7505. SDR SWIA202053632Fitting · corrodedPAX DOOR SILL FWD CLOSING FITTING HAS EVIDENCE OF CORROSION. C-CHECK RO 10/22/2020. PAX DOOR SILL FWD CLOSING FITTING HAS 100% MATERIAL LOSS DUE TO PITTING CORROSION. REMOVED AND INSTALLED NEW PAX DOOR SILL FWD CLOSING FITTING, REF CRJ 700. COMPLETED FORM SDR SWAA2020101214750Stringer Clip · crackedCRACK TIE CLIP ON BS 277 AND STRINGER 10R AT PASSENGER CABIN (1 EA). REPLACED TIE CLIP AT ON BS 277 AND STR 10R AT PASSENGER CABIN (1EA). IAW B737-700 SRM 51-40- 02-0G-0 PARA 4 ITEM B AND DWG 141A8380 SHEET 14 REV.SDR IPXA2020091660314Tee Fitting · crackedINSPECTION TYPE: 2C MAIN CABIN TEE ANGLE IS CRACKED AT STA 1341 AND LONG 15L. REMOVED, FABRICATED, AND REPLACED TEE ANGLE, IAW DWG AEA7568 AND SRM 51-33-01 (MINOR).SDR IPXA2020091660313Tee Fitting · crackedINSPECTION TYPE: 2C MAIN CABIN TEE ANGLE IS CRACKED AT STA 1341 AND LONG 15R. REMOVED, FABRICATED, AND REPLACED TEE ANGLE, IAW DWG AEA7568 AND SRM 51-33-01.SDR SWIA202053630Stringer Clip · corrodedCORROSION ON ATTACHING CLIP FOR STGR 19L FS 295.00. C-CHECK RO 10/22/2020. REMOVED CORRODED STR19L CLIP AT FS 295 AND REPLACED WITH NEW REFERENCING DWG AND CRJ 700 SRM. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWEST FORM M-337.SDR SCNA20201007068Attach Angle · crackedLT 663 UPPER ATTACH ANGLE CRACKED AT APPROXIMATELY LBL 8. REPAIRED LT 663 UPPER ATTACH ANGLE, IAW SRM 57-10-10-2R-5 LBL 8.SDR SWIA202053621Bracket · corrodedSERVICE DOOR SILL THRESHOLD BRACKETS AT APPROXIMATELY FS 321 AND FS 338 HAVE EVIDENCE OF CORROSION. C-CHECK RO 10/22/2020. INSTALLED 4 EA BRACKETS AND 4 EA ANGLES, REF CRJ 700 SRM AND DWG. COMPLIED WITH SKY CARD.SDR DALA2020091103027Gate · corrodedWHILE IN SHOP FOR OVERHAUL FOUND CORROSION ON THE LOWER SURFACE OF THE LOWER GATE AT R4 DOOR, REPAIRED PER ERA 506415-14.SDR SWIA202053615Stringer Clip · corrodedCORROSION ON STRG 20L ATTACH CLIP AT FS 1015.00. C-CHECK RO 10/22/2020. REMOVED CORRODED CLIP FROM STR 20L AT FS 1015 AND REPLACED WITH NEW REFERENCING DWG AND CRJ 700 SRM. COMPLIED WITH SKYWEST TASK CARD. COMPLETED SKYWEST FORM M-337.SDR SWIA2020091452490Bracket · crackedCRACK IN LT ANGLE BRACKET AT FR52 AS MARKED. C-CHECK RO 9/12/2020. REMOVED AND REPLACED LT ANGLE BRACKET AT FR52, REF SRM. RESTORED SURFACE PROTECTION, REF SRM.SDR IPXA2020090219764Tee Fitting · crackedINSPECTION TYPE: 2C MAIN CABIN LONGERON 15L TEE ANGLE CRACKED AT STA.1341. FABRICATED AND INSTALLED MAIN CABIN LONGERON 15L TEE ANGLE AT STA. 1341 IAW SRM 51-31-01 AND 51-33-01. (MINOR)SDR IPXA2020090219762Tee Fitting · crackedINSPECTION TYPE: 2C MAIN CABIN LONGERON 15R TEE ANGLE CRACKED AT STA. 1341. FABRICATED AND INSTALLED MAIN CABIN LONGERON 15R TEE ANGLE AT STA.1341 IAW SRM 51-31-01 AND 51-33-01. (MINOR).SDR IPXA2020090219761Tee Fitting · crackedINSPECTION TYPE:2C MAIN CABIN LONGERON 15R TEE ANGLE IS CRACKED AT STA. 1219. FABRICATED AND INSTALLED MAIN CABIN TEE ANGLE AT LONGERON 15R STA.1219 IAW SRM 51-33-01 AND 51-31-01. (MINOR)SDR SWIA202053213Attach Angle · crackedBACK-UP SILL ATTACH ANGLE AT FS 333.00 AFT SIDE CRACKED. C-CHECK RO 10/9/2020. REMOVED AND REPLACED STR 21L BACK-UP SILL ATTACH ANGLE AT FS 333.00, REF BOMBARDIER DWG AND CRJ900 SRM. COMPLIED WITH.SDR SWIA202052885Stringer Clip · corrodedFS 310.00 STGR 21L CLIP ANGLE HAS CORROSION. C-CHECK RO 9/27/2020. FABRICATED AND INSTALLED CLIP ANGLE AT STGR 21L AT FS 310.00, REF DWG AND CRJ700 SRM.SDR SWIA202052884Stringer Clip · corrodedFS 349.00 AT STR 21L ATTACH CLIP ANGLE CORRODED. C-CHECK RO 9/27/2020. FABRICATED AND INSTALLED ATTATCH ANGLE CLIP AT FS 349.00 AT STR-21L, REF DWG AND CRJ700 SRM.SDR IPXA2020083199608Bracket · crackedINSPECTION TYPE: A 300 AFT CARGO COMPARTMENT ABOVE FWD PRESSURE B/HEAD HAS CRACKED ANGLE SUPPORT AT Y953. FABRICATED & INSTALLED NEW BRACKET IAW A300 SRM 51-40-21.SDR IPXA2020083199607Bracket · crackedINSPECTION TYPE:A 300 AFT CARGO COMPARTMENT ABOVE PRESSURE B/HEAD HAS CRACKED ANGLE SIDEWALL SUPPORT AT Y"0". FABRICATED & INSTALLED BRACKET IAW A300 SRM 51-40-21.SDR SWIA202053209Attach Bracket · corrodedATTACH BRACKET FOR RT FLOOR SILL FS 280-FS 319 AT FS 319 P/N SH670-32177-1 IS CORRODED 100% THROUGH. C-CHECK RO 10/9/2020. REMOVED CORRODED ATTACH BRACKET TO RT FLOOR SILL AT FS 319, REF CRJ900 SRM AND INSTALLED REPLACEMENT ATTACH BRACKET TO RT FLOOR SILL ATSDR SWAA2021072012388Attach Angle · crackedBULKHEAD SUPPORT ATTACH ANGLE IS CRACKED AT ACB BS866 LBL10 WL165. MARKED / REMOVED AND REPLACED BULKHEAD SUPPORT ATTACH ANGLE AT-ACB BS-866 LBL10 WL165 I.A.W. SRM-51-40-02. AND BOEING DWG 149A8102 REV - 59361U 08SEP20SDR SWAA2021072011988Attach Angle · elongatedAFT CARGO BAY TRACK ATTACH ANGLE AT BS 827 RBL 13 WL 156 HAS ELONGATED HOLES / REMOVED AND REPLACED ACB TRACK ATTACH ANGLE AT BS 827 RBL 13 WL 156 P/N 146A1310433 PO # 801731 IAW SRM 51-40-02 REF DWG 146A7500 AND DWG 146A1280 89004U 31AUG20SDR SWAA2021042711927Dome Nut · damagedDAMAGED DOMENUT AT #1 ADF ANTENNA MOUNTING AREA REPAIR PER SRM / ACCOMPLISHED ADF ANTENNA MOUNTING REPAIR STRAP REF B737-700 SRM 53-40-01-2R-1 STEP 4 FIG 203 DETAIL 'A'SDR SWIA202053206Cleat · corrodedCLEAT COMMON TO FRAME AT FS 313.56 AND FWD DD4 INTERCOSTAL HAS CORROSION, MARKED. C-CHECK RO 10/9/2020. REMOVED CORRODED CLEAT COMMON TO FRAME AT FS 313.56 AND FWD DD4 INTERCOSTAL, REF CRJ900 SRM 51-42-06-001-001-A01 AND INSTALLED REPLACEMENT CLEAT, REF CRJ9SDR SWIA202053010Cleat · corrodedFS 338.963 CLEATS AT LOWER CHANNEL CORRODED. C-CHECK RO 10/1/2020. REMOVED AND REPLACED 2 EA CLEATS IN PAX DOOR, FS 338.963 AT LOWER CHANNEL, IAW CRJ-200 SRM.SDR SWAA2020091813627Stringer Clip · corrodedCORROSION ON STRINGER CLIP AT AFT CARGO BAY BS 727E S-22R WL 159, MARKED. REMOVED AND REPLACED STRINGER CLIP AT BS 727E S-22R, PER DWG NR 146A1221 SHEETS 37 AND 39 AND SRM 51-40-02-0G-0.SDR SWAA2020091813626Stringer Clip · corrodedCORROSION ON STRINGER CLIP AT AFT CARGO BAY BS 727E S-23R WL 163, MARKED. REMOVED AND REPLACED STRINGER CLIP AT BS 727E S-23R, PER DWG NR 146A1221 SHEETS 37 AND 39 AND SRM 51-40-02-0G-0.SDR SWAA2020091813625Stringer Clip · corrodedCORROSION ON STRINGER CLIP AT AFT CARGO BAY BS 727D S-21R WL 175, MARKED. REMOVED AND REPLACED STRINGER CLIP AT BS 727D S-21R PER DWG NR 146A1220 SHEET 49 AND SRM 51-40-02-0G-0.SDR SWAA2020091812367Stringer Clip · corrodedCORROSION ON STRINGER CLIP AT AFT CARGO BAY BS 827 LBL 6 WL 157. REMOVED AND REPLACED STRINGER CLIP AT BS 827 LBL 6 S-27L PER DWG 146A1280 SHEET 30 AND SRM 51-40-02-0G-0.SDR SWAA2021071412323Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS 400 RBL25 WL156. / REMOVED AND REPLACED ATTACH ANGLE AT FCB BS 400 RBL 25 WL 156 IAW SRM 51-40-02 AND DWG 143A7505 57049U 03SEP2020SDR SWAA2021071412321Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS 500C AFT SIDE LBL25 WL156. / REMOVED AND REPLACED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500C AFT SIDE LBL25 WL156 I.A.W SRM 51-40-02-0G-0. DWG 143A7902 REV:- AND DWG 143A7505 REV:BSDR SWAA2021060912968Attach Angle · crackedCRACKED ATTACH CLIP ON FWD END OF CABLE GUARD INTERCOSTAL STA 694; RBL 1; WL 204-208. / REMOVED DAMAGED ATTACH CLIP ON FWD END OF CABLE GUARD INTERCOSTAL AT B.S.694 RBL1 WL204-208; AND INSTALLED NEW CLIP PER SRM 51-40-05; SRM 51-40-02; DWG 273A9112 SH.16; AND SDR SWAA2021060912969Attach Angle · crackedCRACKED ATTACH CLIP ON CABLE GUARD INTERCOSTAL STA 694; RBL 24; WL 204. / REMOVED DAMAGED ATTACH CLIP ON CABLE GUARD INTERCOSTAL BS.694 RBL24 WL204; AND INSTALLED NEW CLIP PER SRM 51-40-02; DWG 273A9112 SH.8; AND DWG 273A9110 SH.2; SRM 51-40-05.SDR SWIA202052873Attach Angle · corrodedFS 333.00-FS 349.00 STRG 20RH AFT INTERCOSTAL ATTACH ANGLE CORRODED, MARKED. C-CHECK RO 9/27/2020. REPLACED CORRODED ANGLE WITH NEW ANGLE, REF CRJ-700 SRM. SEE CONTINUE CARD FOR DETAILS.SDR SWAA2021072011763Attach Angle · crackedCRACKED ATTACH ANGLE AT PASSENGER CABIN BS695 RBL1 WL206. MARKED / REMOVED AND REPLACED CRACKED ATTACH ANGLE AT BS695 RBL1 WL206 PER EA 20-153-01663 REV IR; ATS ER 20-03211 REV IR; DWG# 273A9110 REV A; SRM 51-40-02; SRM 51-20-01 AND SOPM 20-41-02SDR SWAA2021072011762Attach Angle · crackedCRACKED ATTACH ANGLE AT PASSENGER CABIN BS695 LBL1 WL203. MARKED / REMOVED AND REPLACED ATTACH ANGLE AT BS695 LBL1 WL203 PER SRM 51-40-05; SRM 51-40-02; AND DWG 273A9110.SDR SWIA202052842Nut Plate · corrodedFWD CARGO BAY TIE DOWN NUTPLATE BRACKET CORRODED, AS MARKED, FS 581 BETWEEN STGRS 22L/23L. C-CHECK RO 9/27/2020. BLENDED OUT CORROSION ON TIE DOWN BRACKET AT FS 581 STGR 22L-23L, REF CRJ700 SRM. FOUND PART TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW TIESDR FDEA202008252295Attach Angle · crackedINSIDE LT MLG WW, AFT OUTBOARD LOWER CORNER, GUSSET TO INBOARD FLAP WELL, UNDER SIDE ATTACH ANGLE IS CRACKED. PREVIOUS REPAIR FAILURE. MAY NOT BE PER SRM, MARKED. REMOVED AND REPLACED CRACKED ANGLE P/N FX ANB7175-57 AS REQ, REF DAC DWG ANB7175 AND SRM 51-31SDR SWIA202053199Attach Angle · corrodedATTACH ANGLE COMMON TO DD6 INTERCOSTAL AT 329.50 IS CORRODED, MARKED. C-CHECK RO 10/9/2020. REPLACED PAX DOOR ATTACH ANGLE AT FS 329.50 P/N 600-31902-269, REF CRJ-900 SRM AND DWG. COMPLIED WITH TASK CARD.SDR SWIA202052643Mount · corrodedTHE FWD INBOARD FLOOR MOUNT FITTING ATTACHED TO THE FLOOR SUPPORT CROSSBEAM FS 295 LOCATED APPROX LBL 20 HAS CORROSION ON ITS UPPER SURFACE, MARKED WITH ORANGE FLAG TAPE. C-CHECK RO 9/20/2020. REPLACED FLOOR MOUNT FITTING WITH NEW FROM STOCK, REF CRJ 700 SRMSDR IPXA2020090259711Tee Fitting · crackedINSPECTION TYPE:2C UPPER CARGO COMPARTMENT LONG 15L T FITTING CRACKED AT STA 1341. REMOVED CRACKED T FITTING, FABRICATED AND INSTALLED IN UPPER CARGO COMPARTMENT LONG 15L AT STA 1341 IAW SRM 51-33-01. (MINOR)SDR SWAA2020090910096Stringer Clip · corrodedCORROSION ON STRINGER CLIP AT AREA AFT OF ACB BS951 RBL 53 WL 199, MARKED. CORROSION ON STR CAP AT AFT OF BS 951 RBL 53 STR 19R FOUND TO BE OUT OF LIMITS, DUE TO NO SRM ALLOWABLE DAMAGE. THE STRUCTURAL ITEM NEED TO REMOVE AND REPLACE, IAW SRM 51-10-02 PAR 9CSDR AALA2020082109014Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND BRACKET CHANNEL CORRODED AT FR 56-57, LBL-10 IN AFT CARGO COMPARTMENT. REMOVED AND REPLACED BRACKET CHANNEL.SDR SWAA2021072009710Attach Angle · corrodedCORROSION ON WEB ATTACH ANGLE AT ACB BS767+8 RBL19 WL154. / REMOVED AND REPLACED ACB ON WEB ATTACH ANGLE AT BS 767+8 RBL19 WL154 DUE TO NO ALLOWABLE LIMITS FOUND IN THE SRM FOR THIS ITEM IAW SRM 51-10-02-0G-0; SRM 51-40-02-0G-0 AND DWG # 146A0081
Back to JASC 5340