JASC 5522
Service difficulty reports · 3,272
Reports filed under 5522 · Elevator, Plate/Skin, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5522' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5522' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201804169039Skin · damagedTRAPPED WATER INDICATION ON RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL, 2.85 INCHES OUTBOARD FROM RIB 4 AND 5.28 INCHES FROM TRAILING EDGE. REPAIRED THE RIGHT ELEVATOR SKIN IAW SRM 55-21-11-300-004, PARAGRAPH 2A.SDR AALA201804169038Skin · damagedTRAPPED WATER INDICATION ON THE RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL, 53 INCHES INBOARD FROM RIB 10 AND 4.40 INCHES FROM TRAILING EDGE. REPAIRED THE RIGHT ELEVATOR SKIN IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR AALA201804169037Skin · damagedTRAPPED WATER INDICATION IN THE RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL, 7.5 INCHES INBOARD FROM RIB 10 AND 3.80 INCHES FROM TRAILING EDGE. REPAIRED THE RIGHT ELEVATOR SKIN IAW SRM 35-21-11-300-005 .SDR AALA201804179002Skin · damagedTRAPPER WATER INDICATED ON RT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS. 27 INCHES INBD FROM RIB 10 AND 4 INCHES FROM TRAILING EDGE. REPAIRED THE RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL IAW SRM 55-21-11-300-005, PAR 2A.SDR AALA201804179001Skin · damagedTRAPPER WATER INDICATED IN THE RT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS, 17.5 INCHES. INBD FROM RIB 10 AND 3 INCHES FROM TRAILING EDGE. REPAIRED THE RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL IAW SRM 55-21-11-300-005, PAR 2A.SDR AALA201803299017Skin · crackedRIGHT ELEVATOR HAS A CRACK IN THE SKIN. REPLACED THE RIGHT ELEVATOR IAW J/C 26L30027001R.SDR DALA2018032802028Skin · damagedLEFT ELEVATOR DAMAGED, PERFORMED NDT INSPECTION FOR DELAMINATION AROUND DAMAGED AREA IAW SRM 51-70-17, PARA 3A (3). REMOVED THE DAMAGE AND INSTALLED A REPAIR IAW RI 567223-14.SDR IPXA2018042088743Skin · crackedINSPECTION TYPE: 3C, RT ELEVATOR LEADING EDGE PANEL 345CT CRACKED. REMOVED AND REPLACED THE LE PANEL IAW AMM 51-33-01.SDR SWIA2018040944495Skin · damagedLEFT ELEVATOR HAS A DAMAGED LEADING EDGE AT EACH HINGE POINT. REPAIRED THE ELEVATOR IAW REO.SDR SIMA20180312005Skin · tornRIGHT UPPER ELEVATOR SKIN TORN AT YH-1310. ACCOMPLISHED A REPAIR IAW SRM 55-20-01, AND ETN-EM-55-022R1.SDR AALA201803229020Skin · damagedTRAPPED WATER INDICATION ON THE RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN. REPAIRED THE RIGHT ELEVATOR IAW EA 278012.SDR CALA2018031200888Skin · saturatedFLUID INGRESS INDICATION, LT ELEVATOR TOP COMPOSITE PANEL. REFERENCE TASK CARD; 3882190 17-5520-1, SRM 0 0 PB 101 & 55-21-11 PB 101) REPAIRED LT ELEVATOR AFFECTED AREAS IAW SRM 55-21-11-283-0 04 TABLE 6104 FLAGNOTE (6), SRM 55-21-11-300-005, AND SRM 51-77-13-9SDR AALA201804039013Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER INDICATION ON LEFT ELEVATOR LOWER SKIN PANEL LOCATED 5 IN OUTBOARD FROM RIB 5 AND 3 IN. FROM TRAILING EDGE. REPAIRED ELEVATOR PER SRM 55-21-11-300-005.SDR AALA201804039014Skin · contaminatedTRAPPED WATER INDICATION ON LEFT ELEVATOR UPPER SKIN PANEL HONEYCOMB CORE CELLS LOCATED 49.5 INCHES OTBD OF RIB 5, AND 5.5 INCHES FROM TRAILING EDGE. REPLACED THE ELEVATOR HONEYCOMB CORE PANEL IAW SRM 55-21-11-300-004.SDR DALA2018030901570Skin · crackedLEFT INBOARD ELEVATOR UPPER SURFACE FOUND CRACK AT ELEVATOR STA114.7, 15IN FROM THE LEADING EDGE. REPAIRED PER SRM 55-20-01 AND 51-70-04.SDR IPXA2018030427104Skin · puncturedLEFT INBD ELEVATOR HAS A PUNCTURE, 48 INCHES FROM INBD EDGE AND 11 INCHES FORWARD OF TRAILING EDGE. REPAIRED THE ELEVATOR SKIN IAW EO B767-5520-67648-A.SDR SWIA2018040244455Skin · dentedLEFT ELEVATOR LOWER SURFACE DENTED, APPROXIMATELY ES 77.68, 12 INCHES FORWARD OF TRAILING EDGE. FABRICATED A DOUBLER AND FILLER, INSTALLED THE REPAIR AND RESTORED FINISH IAW SRM.SDR IPXA2018030227054Panel · crackedINSPECTION TYPE: 3C, LT INBD ELEVATOR L/E FAIRING PANEL LOWER SURFACE AT ATTACH ANGLE WAS FOUND CRACKED, OTBD OF ACTUATOR. ACCOMPLISHED A PERMANENT REPAIR IAW EA. 011-5520-01-A7147, REV IR, AND EO MD11-5520-67625-A. MAJOR.SDR AALA201803099009Skin · saturatedAIRCRAFT IN BASE MAINTENANCE. TRAPPED WATER INDICATION ON RIGHT HAND ELEVATOR HONEYCOMB CORE STRUCTURE UPPER PANEL LOCATED 8.750 INCHES INBOARD FROM ELEVATOR RIB 3 AND 20.5 INCHES AFT FROM LEADING EDGE FASTENER ROW ON RIGHT HAND HORIZONTAL STABILIZER. REPAIREDSDR AALA201803099011Skin · contaminatedTRAPPED WATER INDICATED ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL LOCATED BETWEEN ER2 AND ER3 AND 4 INCHES FROM TRAILING EDGE AND 16 INCHES FROM OUTBOARD ELEVATOR RIB 2. REPAIRED THE LT ELEVATOR HONEY COMB CORE STRUCTURE LOWER PANEL IAW EA 277SDR AALA201803099008Structure · contaminatedTRAPPED WATER INDICATION ON RIGHT ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL AT RIB 4, 4 INCHES FROM TRAILING EDGE ON RIGHT HORIZONTAL STABILIZER. REPAIRED THE RIGHT ELEVATOR HONEY COMB STRUCTURE IAW EA 277207 AND SRM 55-21-11-300-016.SDR DALA2018021500927Skin · crackedLEFT ELEVATOR UP SURFACE AT APPROXIMATELY FROM I/B SIDE 17 IN AND FROM AFT 35 IN FOUND CRACK. REPAIRED SRM 51-70-17.SDR AALA201803229014Skin · damagedTRAPPED WATER INDICATION ON THE RT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL, 8 INCHES INBOUND FROM RIB 10 AND 3.5 INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR SKIN IAW SRM 55-21-11-300-005, PARA 2A.SDR AALA201803229009Skin · delaminatedDELAMINATED ELEVATOR REPAIR ON UPPER SKIN PANEL NEXT TO LIGHTENING STRIP 3, OUTBOARD SIDE AND 5.5 INCH FROM TRAILING EDGE ON RIGHT HORIZONTAL STABILZIER. REPAIRED THE SKIN IAW EA 278012.SDR AALA201803229016Skin · damagedTRAPPED WATER INDICATION ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN, BETWEEN RIBS 9 & 10, 13 INCHES FROM RIB 10 AND 3.5 INCHES FROM TRAILING EDGE. REPAIRED THE ELEVATOR SKIN IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR AALA201803229015Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER INDICATED ON TOP SKIN OF THE RIGHT HAND ELEVATOR AT STA 2265, RIB 6. REMOVED DAMAGE AREA AND ACCOMPLISHED REPAIR OF RIGHT HAND ELEVATOR UPPER SKIN PANEL PER EA 278012.SDR AALA201803149017Skin · damagedTRAPPED WATER INDICATION ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN. REPAIRED THE SKIN IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR AALA201803139029Skin · saturatedAIRCRAFT IN BASE MAINTENANCE. TRAPPED WATER INDICATION ON LEFT HAND ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL APPROXIMATELY 55 INCHES OUTBOARD FROM RIB 5 AND 3.5 INCHES FROM TRAILING EDGE ON LEFT HAND HORIZONTAL STABILIZER. REPAIRED LEFT HAND ELEVATOR HONSDR AALA201803139018Skin · damagedTRAPPED WATER INDICATION ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE LOWER SKIN PANEL. REPAIRED THE LEFT ELEVATOR SKIN IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR AALA201803139017Skin · damagedTRAPPED WATER INDICATION ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL. REPAIRED THE LEFT ELEVATOR SKIN IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR AALA201803139016Skin · damagedTRAPPED WATER INDICATION ON THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL, 9 INCHES OUTBOARD FROM LIGHTNING STRIP 4, 3.5 INCHES. REPAIRED THE LEFT ELEVATOR SKIN PANEL IAW SRM 55-21-11-300-005, PARAGRAPH 2A.SDR DALA2018020400753Skin · damagedLT ELEVATOR SKIN DAMAGED, UPPER SURFACE I/B END C/W SRM 55-20-01.SDR 7C7A201801300359Skin · damagedDAMAGE FOUND ON THE RIGHT ELEVATOR UPPER SKIN. REPAIRED IAW ECO 008.55-18-01.SDR AALA201803129045Skin · damagedRIGHT ELEVATOR HAD TRAPPED WATER INDICATED IN THE ELEVATOR HONEYCOMB CORE STRUCTURE UPPER PANEL LOCATED 15 INCHES OTBD FROM ELEVATOR RIB 9 AND 7.25 INCHES FROM TRAILING EDGE OF RIGHT HAND HORIZONTAL STABILIZER. REPAIRED THE RIGHT ELEVATOR HONEYCOMB CORE STRUCSDR AALA201803129043Skin · damagedLEFT ELEVATOR HAS TRAPPED WATER LOCATED BETWEEN RIBS 7 AND 8, 3.25 INCHES INBOARD FROM ELEVATOR RIB 8 AND 8 INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL IAW EA 277206 AND SRM 55-21-11-300-008.SDR AALA201803099020Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER INDICATED ON LEFT HAND ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL LOCATED BETWEEN RIB 6 AND RIB 7. REPAIRED LEFT HAND ELEVATOR HONEYCOMB PER EA 277206 AND A330 SRM 55-21-11-300-008.SDR AALA201803099012Skin · contaminatedTRAPPED WATER INDICATED ON LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER PANEL LOCATED BETWEEN ER 8 AND ER9 AT 8.75 INCHES FROM TRAILING EDGE AND 7.0 INCHES INBOARD FROM ELEVATOR RIB 8. REPAIRED THE LEFT ELEVATOR HONEYCOMB CORE STRUCTURE UPPER PANEL IAW EA N.2SDR AALA201802059012Skin · contaminatedTRAPPED WATER INDICATED ON ELEVATOR HONEYCOMB LOWER SKIN BETWEEN RIBS 8 AND 9, 21.5 INCHES FROM RIB 8 AND 4 INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR SKIN IAW SRM 55-21-11-300-005, PAR 2A.SDR AALA201802059011Skin · contaminatedTRAPPED WATER INDICATED ON THE LEFT ELEVATOR HONEYCOMB UPPER SKIN, LOCATED 22.5 INCHES OTBD FROM LIGHTNING STRIP 2, AND 3.5 INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR HONEYCOMB IAW SRM 55-21-11-300-005, PAR 2.A.SDR AALA201801319012Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER FOUND ON THE ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL LOCATED 13 INCH OUTBOARD FROM LIGHTNING STRIP 1 AND 10.5 IN FROM THE LEADING EDGE FASTENERS ON THE RIGHT HAND HORIZONTAL STABILIZER. REPAIRED RIGHT SDR AALA201801319011Skin · contaminatedTRAPPED WATER FOUND ON THE ELEVATOR HONEYCOMB CORE STRUCTURE UPPER SKIN PANEL LOCATED 7.25 IN OUTBOARD FROM LIGHTENING STRIP 2 AND 7 INCH FROM LEADING EDGE FASTENERS. REPAIRED ELEVATOR HONEYCOMB CORE STRUCTURE IAW SRM 55-21-11-300-005 PAR2.A.SDR K11A2017110573307Skin · puncturedLEFT HAND ELEVATOR LOWER SURFACE PUNCTURED. REPAIRED LEFT ELEVATOR SURFACE PUNCTURE IAW SRM 55-20-01 REPAIR 1.SDR K11A2017110573306Skin · puncturedLEFT HAND ELEVATOR UPPER SURFACE PUNCTURED. REPAIRED PUNCTURE ON UPPER SURFACE OF LEFT ELEVATOR IAW SRM 51-70-05, REPAIR 3.SDR AALA201802059013Skin · contaminatedTRAPPED WATER INDICATED ON THE LEFT ELEVATOR HONEYCOMB UPPER SKIN PANEL, 1 INCH FROM LIGHTNING STRIP 1, AND 3.5 INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR HONEYCOMB SKIN IAW SRM 55-21-11-300-005, PAR 2A.SDR AALA201802059010Skin · contaminatedTRAPPED WATER INDICATED ON ELEVATOR HONEYCOMB CORE STRUCTURE OF THE LOWER SKIN PANEL BETWEEN RIBS 6 AND 7, 6.5 INCHED FROM RIB 7 AND 3.5 INCHED FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR HONEYCOMB SKIN IAW SRM 55-21-11-300-005, PAR 2.A.SDR AALA201802059009Skin · contaminatedLEFT ELEVATOR LOWER SURFACE HAS INDICATION OF TRAPPED WATER BETWEEN RIBS 8 AND 9, FIVE INCHES FROM RIB 8 AND FOUR INCHES FROM TRAILING EDGE. REPAIRED THE LEFT ELEVATOR LOWER SURFACE IAW SRM 55-21-11-300-005, PAR 2A.SDR AALA201801109008Skin · contaminatedLEFT ELEVATOR TOP SKIN HAS INDICATION OF WATER INGRESS, 1.750 DIAMETER, 10.5 INCHES FROM TRAILING EDGE, 24 INCHES FROM INBOARD END. REMOVED DAMAGE, INSTALLED A NEW CORE AND LAY UP REPAIR PLIES IAW SRM 55-21-11-300-007.SDR AALA201801109007Skin · contaminatedLEFT ELEVATOR TOP SKIN HAS INDICATION OF WATER INGRESS, 1.250 DIAMETER, 19 INCHES FROM TRAILING EDGE, 26 INCHES FROM INBAORD END. REMOVED DAMAGE, INSTALLED A NEW CORE AND LAY-UP REPAIR PLIES IAW SRM 55-21-11-300-007.SDR AALA201801129024Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER INDICATION ON ELEVATOR HONEYCOMB CORE STRUCTURE UPPER PANEL IN MULTIPLE AREAS BETWEEN 17 INCHES OUTBOARD AND 8.7 INCHES INBOARD OF THE LIGHTNING STRIP 1, AND BETWEEN 3.5 AND 3.7 INCHES FROM THE TRAILING EDGE. REPSDR AALA201801129023Skin · saturatedAIRCRAFT WAS IN BASE MAINTENANCE. TRAPPED WATER INDICATION IN MULTIPLE AREAS ON ELEVATOR HONEYCOMB CORE STRUCTURE LOWER PANEL LOCATED BETWEEN 8 AND 70 INCHES INBOARD OF RIB 10 , AND 3.5 INCH FROM THE TRAILING EDGE ON THE RT HORIZONTAL STABILIZER. REPLACED ELEV
Back to JASC 5522