JASC 5522
Service difficulty reports · 3,272
Reports filed under 5522 · Elevator, Plate/Skin, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5522' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5522' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20120912026Skin · puncturedLEFT OUTBOARD ELEVATOR UPPER SKIN HAS PUNCTURE 51 INCHES FROM OUTBOARD AND 25.5 INCHES FROM TRAILING EDGE. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-04.SDR AALA20120912025Skin · puncturedLEFT OUTBOARD ELEVATOR UPPER SKIN PUNCTURED 11 INCHES FROM OUTBOARD AND 22 INCHES FROM TRAIILNG EDGE. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-04.SDR AALA20120912019Skin · damagedLEFT OUTBOARD ELEVATOR UPPER SKIN 11 INCHES FROM OUTBOARD AND 16 INCHES FROM TRAILING EDGE DAMAGED. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-04.SDR AALA20120912006Skin · damagedRIGHT OUTBOARD ELEVATOR UPPER SKIN 71.5 INCHES FROM OUTBOARD AND 15 INCHES FROM TRAILING EDGE. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-04.SDR AALA20120912005Skin · damagedRIGHT ELEVATOR UPPER SIDE DAMAGED 108 INCHES FROM OUTBOARD AND 15.5 FROM TRAILING EDGE. ACCOMPLISHED BONDED REPAIR SRM 51-70-04.SDR AALA20120912001Skin Panel · damagedHAIL DAMAGE TO UPPER SKIN PANEL OF RIGHT ELEVATOR. ACCOMPLISHED BONDED REPAIR PER SRM 51-70-04.SDR CA120912007Skin · damaged(CAN) FLIGHT CREW REPORTED LIGHTNING STRIKE IN CRUISE AT 17000 FT. MAINTENANCE INSPECTION REVEALED SUPERFICIAL DAMAGE DUE TO LIGHTNING STRIKE ON THE RT ELEVATOR, OTBD, T/E CLOSING SKIN AT THE OTBD SKIN EDGE MEASURING .300" WIDE X .400" LENGTH. 1 CHERRY MAX RISDR FDEA201209043221Skin · damagedLT ELEVATOR TIP PANEL UPPER SURFACE HAS 2 EA LIGHTNING STRIKES. REPAIRED IAW EA 6-5520-157869 PART 1 AND RAS, ISSUE A.SDR FDEA201209043220Skin · damagedLT ELEVATOR TIP LOWER SURFACE HAS A LIGHTNING STRIKE. REPAIRED IAW EA 6-5520-157869, AND RAS 70566303/003/2012, ISSUE A.SDR DALA12006330857Skin · damagedLT ELEVATOR UPPER OTBD SKIN HAS A LIGHTNING STRIKE. REMOVED DAMAGE (CUT-OUT) ON LT ELEVATOR UPPER OTBD SKIN, FABRICATED REPAIR DOUBLER FROM CLAD 2024-T3 AND REWORKED TO 0.036. PERFORMED HFEC INSPECTION AND NOTED NO CRACKS AT CUT OUT. LOCATED AND DRILLED REPSDR USAA2012090500016Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 18.5 INCHES FROM INBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 18.5 INCHES FROM INBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500015Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 69.5 INCHES FROM OUTBOARD EDGE AND 6.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 69.5 INCHES FROM OUTBOARD EDGE AND 6.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500014Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 9 INCHES FROM OUTBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 9 INCHES FROM OUTBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500012Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 27 INCHES FROM OUTBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 27 INCHES FROM OUTBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500011Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 5.5 INCHES FROM INBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 5.5 INCHES FROM INBOARD EDGE AND 5.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012091700020Skin · saturatedC11 CHECK - LEFT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION AT STA 5274, 4 INCHES FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700029Skin · saturatedC11 CHECK - RIGHT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION AT STATION 4655, 9.25 INCHES FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700026Skin · saturatedC11 CHECK - RIGHT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION BETWEEN STATION 1809 AND STATION 2265, 15.5 INCHED AFT OF LEADING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700021Skin · saturatedC11 CHECK - LEFT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION AT STATION 4655, 4 INCHES FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PAR 5.E.SDR USAA2012091700019Skin · saturatedC11 CHECK - LEFT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION AT STATION 2707, 4 INCHES FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700018Skin · saturatedC11 CHECK - RIGHT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION AT STATION 3416, 11.5 INCHES FORWARD OF TRAILING EDGE. REPAIR SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700017Skin · saturatedC11 CHECK - RIGHT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION BETWEEN STATION 2265 AND STATION 2707, 6.25 INCHES FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5.E.SDR USAA2012091700014Skin · saturatedC11 CHECK - LEFT ELEVATOR UPPER SKIN HAS TRAPPED WATER INDICATION BETWEEN STATION 5894 & STATION 6009, 4 INCHES FORWARD OF TRAILING EDGE. REPAIR SKIN IAW A319 SRM 55-21-11 PARAGRAPH 5E.SDR USAA2012090500020Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON LEFT ELEVATOR ON UPPER PANEL 71 INCHES FROM INBOARD EDGE AND 7 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR ON UPPER PANEL 71 INCHES FROM INBOARD EDGE AND 7 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500019Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON LEFT ELEVATOR ON UPPER PANEL 76 INCHES FROM OUTBOARD EDGE AND 20.5 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR ON UPPER PANEL 76 INCHES FROM OUTBOARD EDGE AND 20.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500018Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON LEFT ELEVATOR ON UPPER PANEL 54 INCHES FROM OUTBOARD EDGE AND 16.5 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR ON UPPER PANEL 54 INCHES FROM OUTBOARD EDGE AND 16.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500017Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON LEFT ELEVATOR ON UPPER PANEL BETWEEN 87 TO 104 INCHES FROM INBOARD EDGE AND 10 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR ON UPPER PANEL BETWEEN 87 TO 104 INCHES FROM INBOARD EDGE AND 10 INCHES FROM TRAILING EDGE IAW A319 SSDR USAA2012090500013Skin Panel · saturatedSY6 CHECK - WATER INGRESS ON RIGHT ELEVATOR ON UPPER PANEL 27.5 INCHES FROM OUTBOARD EDGE AND 8.5 INCHES FROM TRAILING EDGE. REPAIRED RIGHT ELEVATOR ON UPPER PANEL 27.5 INCHES FROM OUTBOARD EDGE AND 8.5 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR USAA2012090500009Skin · saturatedSY6 CHECK - WATER INGRESS ON LEFT ELEVATOR ON UPPER PANEL 33 INCHES FROM INBOARD EDGE AND 20 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR 33 INCHES FROM INBOARD EDGE AND 20 INCHES FROM TRAILING EDGE IAW A319 SRM 55-20-00.SDR GLBA2012083100043Skin · burned.5 X .5 INCH BURN HOLE IN TOP AND BOTTOM SKIN, 3.8750" CENTER FROM OTBD TIP OF LT ELEVATOR T/E. REPAIRED THE AFFECTED AREA IAW EO 12-1900-27-002.SDR FDEA201208153005Skin · dentedRIGHT INBD ELEVATOR LOWER SURFACE INBD T/E WEDGE FOUND DENTED. REPAIRED IAW SRM 55-33-00, FIG 2, VOLUME I, REV 99. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 115.SDR FDEA201208142993Skin · misrepairedLEFT INBD ELEVATOR LOWER SURFACE T/E WEDGE MISREPAIRED. REPAIRED AS PER SRM 55-30-00 FIG.2 VOL.I REV.99. REPAIR CLASSIFED MAJOR AS PER GMM 6-2-100 REV. 115.SDR FDEA201208132968Skin · misrepairedLEFT ELEVATOR UPPER SKIN STATION XE 233 MISREPAIRED. REPAIRED IAW SRM 55-10-00, FIG 8, VOL I, REV 99. REPAIR CLASSIFED MAJOR IAW GMM 6-2-100 REV 115.SDR FDEA201208132967Skin · misrepairedLEFT ELEVATOR UPPER SKIN STATION XE 142 MISREPAIRED. REPAIRED IAW SRM 55-10-00, FIG 8, VOL I, REV 99. REPAIR CLASSIFED MAJOR IAW GMM 6-2-100 REV 115.SDR FDEA201208132966Skin · misrepairedLEFT ELEVATOR UPPER SKIN STATION XE 206 MISREPAIRED. REPAIRED IAW SRM 55-10-00, FIG 8 VOL I, REV 99. REPAIR CLASSIFED MAJOR IAW GMM 6-2-100, REV 115.SDR FDEA201208132969Skin · misrepairedRIGHT INBD ELEVATOR UPPER SURFACE MISREPAIRED. REPAIRED IAW SRM 55-10-00, FIG 8, VOL 1, REV 99. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 115.SDR USAA2012072400019Skin · saturatedC11 CHECK - WATER INGRESS ON LEFT ELEVATOR 5 INCHES INBOARD FROM RIB 10, 5 INCHES FROM TRAILING EDGE. REPAIRED LEFT ELEVATOR 5 INCHES INBOARD FROM RIB 10, 5 INCHES FROM TRAILING EDGE IAW A321 SRM 55-21-11 PARAGRAPH 5, E.SDR USAA2012072400018Skin · saturatedC11 CHECK - WATER INGRESS FOUND IN RIGHT ELEVATOR UPPER SKIN 8.00 IN INBOARD OF RIB 10, 4.75 IN FORWARD OF TRAILING EDGE. REPAIRED SKIN IAW A321 SRM 55-21-11 PARA 5.E.SDR SWAA2012072306118Skin · puncturedRIGHT ELEVATOR PUNCTURED ON UPPER SURFACE APPROX 6.5 INCHES FROM TRAILING EDGE AND 41.5 INCHES FROM OUTBD END. REPAIRED ELEVATOR PER SRM.SDR IPXA2574430Skin · damagedRT ELEVATOR HAS 3 HAIL DAMAGE HOLES IN UPPER SKIN. 1 IS WITHIN THE CRITICAL AREA. HOLE IS 67.000 FROM INBD EDGE AND 29.500 FROM T/E. REPAIRED IAW SRM 55-20-01-1A, FIG 101.SDR IPXA2574429Skin · dentedRT ELEVATOR HAS 1 DENT THAT IS WITHIN THE CRITICAL AREA. DENT IS 110.000 FROM INBD EDGE AND 19.250 FROM THE T/E. CLASSIFIED AS MAJOR REPAIR. REPAIRED IAW EO B757-5520-47896A. THIS CLEARS D478494.SDR USAA2012072300016Skin · saturatedC11 CHECK - WATER INGRESS SPOTS ON UPPER SURFACE OF RIGHT ELEVATOR. REPLACED RIGHT ELEVATOR IAW A319 AMM 27-34-41.SDR CA120716018Skin · separated(CAN) DEPARTED WHILE LEVELING OFF INTO CRUISE, A BANG WAS HEARD AND FOLLOWED BY A VIBRATION FELT IN THE CONTROLS AND CONTROLLABILITY PROBLEMS. THE CREW DECLARED AN EMERGENCY AND LANDED SAFELY BACK. AFTER LANDING IT WAS DISCOVERED THAT APPROXIMATELY 95 PERCENT SDR AALA20120712006Skin · delaminatedDELAMINATION ON TOP SIDE OF ELEVATOR. ACCOMPLISHED HOTBOND REPAIR PER SRM 55-20-01.SDR AALA20120713013Skin · damagedMULTIPLE HAIL DENTS ON THE RIGHT ELEVATOR. INSTALLED DOUBLER REPAIR AT 102 INCHES FROM I/B EDGE PER SRM 55-03-00 FIG 13A. MRT# 037758.SDR USAA2012071600012Skin · saturatedBC1 CHECK - WATER INGRESS ON UPPER SURFACE OF LEFT ELEVATOR AT ZONE 1 AND ZONE 3. REPAIRED UPPER SURFACE OF LEFT ELEVATOR AT ZONE 1 AND ZONE 3 IAW A320 SRM 55-21-11 AND 55-20-00.SDR IPXA12674327Skin · dentedINSPECTION TYPE: 1C, LT OTBD ELEVATOR UPPER SURFACE DENTED. COMPOSITE WET LAY UP REPAIR CARRIED OUT IAW RS NR R-55-23-37367-A AND EO B767-5520-47813-A.SDR IPXA12674326Skin · dentedINSPECTION TYPE: 1C, LT OTBD ELEVATOR UPPER SURFACE DENTED. COMPOSITE PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-04, PAR 5A (1), FIG 5, REV 52.SDR IPXA12674313Skin · puncturedINSPECTION TYPE:1C, RT OTBD ELEVATOR UPPER SURFACE PUNCTURED. COMPOSITE PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-04, PAR 5A(1) FIG 5, REV 52.SDR IPXA12674308Skin · dentedINSPECTION TYPE: 1C, LT OTBD ELEVATOR UPPER SURFACE DENTED. COMPOSITE PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-04, PAR 5A(1) FIG 5, REV 52.
Back to JASC 5522