JASC 5534
Service difficulty reports · 820
Reports filed under 5534 · Vertical Stabilizer Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5534' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5534' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20140926005Bushing · damagedHOLE OUT OF ROUND AT FREEZE BUSHING 17TH LT FASTENER BELOW ZFS 52.267. ACCOMPLISHED NESTED ANGLE REPAIR IAW SRM 55-03-00-001.SDR AALA20140926004Bushing · damagedHOLE OUT OF ROUND AT FREEZE BUSHING 13TH LT FASTENER BELOW ZFS 52.267. ACCOMPLISHED NESTED ANGLE REPAIR IAW SRM 55-03-00-001.SDR AALA20140922003Band · damagedDORSAL FIN BAND AT STATION 52.267 HOLES OUT OF ROUND. REPLACED 503 BAND IAW SRM 55-03-00.SDR GLBA2014092200445Structure · crackedDURING A SCHEDULED INSPECTION MAINTENANCE FOUND A CRACK IN THE RT FWD VERT STAB HAT SECTION AT FWD FLANGE BEND RADIUS, .20% CHORD & VSS 90.0, 1 INCH IN LENGTH. REPAIRED THE AFFECTED AREA & PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 14-1900-55-009. MATERIASDR SWAA2014092532320Attach Angle · crackedVERTICAL STABILIZER PANEL 9508 SKATE SEAL ATTACH ANGLE CRACKED. R & R ANGLE IAW SRM.SDR SIMA20140915007Drag Angle · crackedLEFT VERTICAL STAB FWD DRAG ANGLE CRACKED AT AFT END. REPAIRED LT VERTICAL STAB FWD DRAG ANGLE IAW EO CR-55MR-038R1.SDR AALA20140912009Structure · wornFOUND WEAR IN VERTICAL STABILIZER DORSAL FASTENER HOLES. INSTALLED REPAIR DOUBLER IAW SRM 55-03-00-001.SDR SWAA2014100232574Support · crackedVERTICAL STAB INTERNAL FWD SUPPORT WEB STRINGER 8L FRAME CRACKED. REPAIRED WEB IAW EA.SDR SWAA2014100732730Fitting · corrodedLEFT VERTICAL STABILIZER OTBD AFT SPAR LUG FWD & AFT BUSHING FITTING CORRODED. R & R FITTING IAW EA.SDR SWAA2014102033212Fitting · crackedCROSSBEAM CUT OUT AT FWD LUG FITTING ON RT SIDE CRACKED. R & R FITTING IAW SRM.SDR SWAA2014082631277Structure · delaminatedDORSAL FIN DELAMINATED RT SIDE AT STATION 961, 23 INCHES FROM LOWER LIP. REPAIRED FIN IAW SRM.SDR SWAA2014081130744Retainer · crackedVERTICAL STABILIZER PANEL 9507 RETAINER CRACKED. R & R RETAINER IAW SRM.SDR SWAA2014082731309Fitting · corrodedFORWARD LT BORE AT FITTING VERTICAL STABILIZER CORRODED. REPAIRED STABILIZER IAW EA.SDR A6WA201441836Angle · crackedRT VERTICAL STAB INBD FARING MOUNT ANGLE CRACKED AFT OF HSTAB LE LOWER SIDE.SDR SWAA2014100632690Lug · corrodedVERTICAL STABILIZER RT FAILSAFE LUGS FWD & AFT ON ACFT CORRODED. REPAIRED LUG IAW EA.SDR SWAA2014100632689Lug · corrodedVERTICAL STABILIZER LT FAILSAFE LUGS FWD & AFT ON ACFT CORRODED. REPAIRED LUG IAW EA.SDR SWAA2014080630640Plate · crackedVERTICAL STABILIZER ACCESS PANEL 9506 PLATE CRACKED. R & R PLATE IAW SRM & DWG.SDR SWAA2014100632688Lug · corrodedVERTICAL STABILIZER RT SIDE FWD LUG BORE CORRODED. REPAIRED LUG IAW EA.SDR SWAA2014100632687Lug · corrodedVERTICAL STABILIZER LT SIDE FWD LUG CORRODED. REPAIRED LUG IAW EA.SDR SWAA2014100732729Fitting · corrodedRIGHT VERTICAL STABILIZER OTBD AFT SPAR LUG, FWD & AFT BUSHING FITTING CORRODED. REPAIRED FITTING IAW EA.SDR SWAA2014100632686Fitting · corrodedVERTICAL STABILIZER RT FAILSAFE LUGS FWD & AFT ON ACFT CORRODED. REPAIRED FITTING IAW AAR EA & SWA EA.SDR SWAA2014100632677Attach Fitting · corrodedVERTICAL STABILIZER LT INBD AFT SPAR LUG FWD & AFT BUSHINGS ATTACH FITTING CORRODED. REPAIRED FITTING IAW AAR & EA.SDR SWAA2014100632676Attach Fitting · corrodedVERTICAL STABILIZER RT INBD AFT SPAR LUG FWD & AFT BUSHINGS ATTACH FITTING CORRODED. REPAIRED FITTING IAW AAR & EA.SDR SWAA2014061128956Splice · crackedUPPER FUSELAGE AT VERTICAL STABILIZER LE AFT MOUNTING SPLICE CRACKED AT TRANSITION FAIRING ACCESS PANEL STATION 1126. R & R SPLICE IAW & DWG.SDR SWAA2014061128955Angle · crackedUPPER FUSELAGE TO VERTICAL STABILIZER LE RT & LT ACCESS PANEL MOUNT ANGLES CRACKED AT STATION 1126. R & R ANGLES IAW SRM & DWG.SDR YADA20140516002Angle · crackedCRACK IN VERTICAL STABILIZER FWD SPAR LT ANGLE AT ATTACH BRACKET FASTENER. SEE SB 55-4114 & AD 2013-24-03.SDR YADA20140516001Angle · crackedCRACKS IN VERTICAL STABILIZER FWD SPAR RT ANGLE AT BRACKET ATTACH FASTENERS.SDR SWAA2014052928462Plate · crackedVERTICAL STABILIZER TE LOWER STRUCTURE OF ACCESS PANEL 9508R PLATE CRACKED. R & R PLATE IAW SRM & DWG.SDR AALA20140508012Bushing · wornTOP HOLE IN LOWER WRAP AROUND LT SIDE MARKED NR 13 IS WORN. ACCOMPLISHED REPAIR IAW EA MD80-55-034804.SDR EPUA20140508001Structure · crackedDURING A SCHEDULED INSPECTION TO COMPLY WITH AD 2013-24-03, A CRACK WAS IDENTIFIED ON PN 101-6400 11-4. THIS PART IS LOCATED ON THE HORIZONTAL ATTACH POINT OF THE VERTICAL STABILIZER. A REPAIR WAS DEVELOPED BY THE MANUFACTURER TO CORRECT THIS IAW DWG FR-CO-1SDR USAA2014042800015Beam · crackedC3 CHECK CRACK ON VERTICAL STABILIZER FIXED TE BEAM AT FIN STA 95.90, LBL10. REPAIRED VERTICAL STABILIZER FIXED TE BEAM AT FIN STA 95.90, LBL 10 IAW SRM 51-40-02, 51-40-05 & DWG173N1300.SDR SWAA2014043027540Angle · crackedVERTICAL STABILIZER ANGLE CRACKED AT ACCESS PANEL 9503. R & R ANGLE IAW SRM & DWG.SDR ABXA2014040470Support Angle · crackedVERTICAL STAB ACCESS 324CLX & 324AL, SUPPORT STRUCTURE BOX FWD LWR FLANGE CRACKED LT & RT OTBD EDGES. REMOVED CRACKED SUPPORT ANGLE. FABRICATED NEW SUPPORT IAW DWG 173T1215 & SAMPLE. PN 173T1302-1, NSN, SUPPORT ANGLE, CRACKED 2 INCHES & 1.5 INCHES, STATION SDR SWAA2014041427132Spring · crackedHORIZONTAL CROSS CHANNEL SPRING CRACKED AT LT & RT SIDES JUST AFT & ABOVE VERTICAL STABILIZER FWD ATTACH POINTS. R & R SPRING IAW SRM.SDR SIMA20140315005Drag Angle · crackedRIGHT VERTICAL STABILIZER BOTTOM SUPPORT DRAG ANGLE IS CRACKED. REPAIRED RT VERTICAL STAB BOTTOM SUPPORT DRAG ANGLE IAW EO CR-55MR-038R1.SDR CALA2014031200314Angle · wornRIGHT SIDE CLOSURE ANGLE FOR VERTICAL STABILIZER PANEL IS WORN. R & R CLOSURE ANGLE IAW SRM 51-40-05 & 51-40- 02.SDR CALA2014031000309Angle · wornLT VERTICAL RT STAB CLOSURE ANGLE WORN STATION 1006 - 1016. R & R CLOSURE ANGLE IAW SRM 51-40-02.SDR CALA2014031000308Angle · wornRT SIDE CLOSURE ANGLE FOR VERTICAL STABILIZER PANEL 323AR WORN. R & R CLOSURE ANGLE IAW SRM 51-40-02.SDR CALA2014031000307Angle · wornRT SIDE CLOSURE ANGLE FOR VERTICAL STABILIZER PANEL 323CR IS WORN. R & R CLOSURE ANGLE IAW SRM 51-40-02.SDR SIMA20140309008Drag Angle · crackedRIGHT VERTICAL STAB AFT BOTTOM SUPPORT DRAG ANGLE CRACKED ON FWD SIDE APPROX .250 INCHES. REPAIRED RT VERTICAL STAB AFT BOTTOM SUPPORT DRAG ANGLE IAW EO CR-53MR-164R1.SDR GLBA2014030300398Channel · crackedDURING A SCHEDULED INSPECTION MX FOUND A CRACK IN THE LT HAT SECTION OF THE UPPER FLANGE FROM FWD FASTENER TO FLANGE LE, VSS 84.10 & 206 CHORD, .35 INCH IN LENGTH. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 14-1900-55-002.SDR AALA20140303003Structure · damagedVERTICAL STAB LT HAND HOLE, 4TH HOLE BELOW STATION ZFS 52.267 ELONGATED. INSTALLED BUSHING & STRAP REPAIR IAW DRAWING SG09550005.SDR SWAA2014032426415Web · crackedVERTICAL STABILIZER TE WEB CRACKED AT FIN STATION 81.80. R & R WEB IAW SRM & DWG.SDR SWAA2014021725226Support · crackedRT VERTICAL STABILIZER FIN PANEL 324CR LOWER SUPPORT STRIP CRACKED. R & R STRIP IAW SRM.SDR SWAA2014021725225Support · crackedRT VERTICAL STABILIZER FIN PANEL 323CR LOWER SUPPORT STRIP CRACKED. R & R STRIP IAW SRM.SDR SIMA20140113008Drag Angle · crackedRIGHT STABILIZER AFT DRAG ANGLE CRACKED APPROXIMATELY 1.062 INCHES. REPAIRED DRAG ANGLE IAW EO CR-53MR-164R1.SDR SIMA20140113009Drag Angle · crackedRIGHT STABILIZER FWD DRAG ANGLE CRACKED APPROXIMATELY 1.375 INCHES. REPAIRED IAW EO-CR-55MR-038.SDR SIMA20131230001Drag Angle · crackedLEFT AFT VERTICAL STABILIZER TO FUSELAGE DRAG ANGLE IS CRACKED. REPAIRED IAW EO CR-55MR-038.SDR A6WA201312274540Attach Bracket · crackedATTACH BRACKET FOR THE 326CR PANEL IS CRACKED. RT FWD SIDE OF V STAB. R & R WITH NEW SERVICEABLE PART IAW CRJ 200 SRM 51-24-21, 51-40-11 & 51-42-21.SDR SWAA2014010923933Angle · crackedRT DORSAL FIN CLOSURE PANEL RETAINER ANGLE CRACKED. R & R ANGLE IAW BAC DRAWING & SRM.
Back to JASC 5534