JASC 5534
Service difficulty reports · 820
Reports filed under 5534 · Vertical Stabilizer Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5534' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5534' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09557205Fastener · damagedINSPECTION TYPE:C2 LIGHTNING STRIKE ON FASTENER ON LT SIDE VERTICAL STAB 6 INCHES AFT OF L/E WL 575. REPAIRED PER ATS ER 09-4262 DATED 26AUG09 AND UPS EO B757-5530-34728-A.SDR USAA2009090392333Support · corrodedSAL - Q6 - MAJOR REPAIR - CORROSION ON SUPPORT STRUCTURE CHORD AT LEFT SIDE OF TRAILING EDGE OF VERTICAL STABILIZER FIN STA 182.30. REPLACED SUPPORT STRUCTURE AT LEFT SIDE OF TRAILING EDGE OF VERTICAL STABILIZER FIN STA 182.30 IAW B737 SRM 51-40-02 & 51-10-02SDR SWAA094744Fitting · corrodedDURING SCHEDULED 12Y CHECK, FOUND VERTICAL STABILIZER AFT O/B DRAG ANGLE FITTING CORRODED. REMOVED AND REPLACED FITTING PER SRM.SDR C2XA09TY169Fitting · chafedTYS - A/C CURRENTLY IN A C-CHECK STATUS WHEN INSPECTION FOUND CORROSION ON FRAME 75 VERTICAL STAB FITTING, 4 BOLT HOLES HAD SOME CORROSION. MAINTENANCE REMOVED THE FITTING AND REAMED THE FOUR HOLES AND BUSHINGS INSTALLED. THEN REINSTALL THE FITTING IAW EC 55SDR FDEA200906262324Support · crackedLT NR2 ENGINE INTAKE DUCT (INTERNAL) SUPPORT FRAME AT STA ZFR 2033 FOUND WITH CRACK. REPAIR CARRIED OUT AS PER E.A. 1-5530-132119, REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100, REVISION 107.SDR SWAA093668Structure · delaminatedDURING SCHEDULED 8Y CHECK, FOUND VERTICAL STABILIZER L/E DELAMINATED. REPAIRED STABILIZER PER EA.SDR FDEA200905261794Fitting · chafedFOUND CHAFING MARK ON VERTICAL STABILIZER FITTING NR 1 REPAIR PERFORMED BY NDT INSPECTION WITHOUT FINDINGS AND SURFACE REPAIR IAW RAS/DAHAM/4027020/2009 ISS A, APPROVED BY EA 6-5530-129170.SDR DXTA2009050603635Structure · damagedFOUND DAMAGE ON VENTRAL FIN. POSSIBLE LIGHTNING STRIKE. LOCATED, DRILLED, AND INSTALLED REPLACEMENT VENTRAL FIN USING SCREWS AND RIVETS PER SRM 51-40-01 AND SERVICE MANUAL DEVIATION FORM NUMBER 1-18X37K.SDR C2XA09TY075Housing · corrodedBOTH SPHERICAL BEARING HOUSING'S ON VERTICAL STAB HAVE CORROSION. REAMED HOUSING AND INSTALLED NEW BUSHINGS IAW EMB AMM 55-30-02 AND COMPLIED WITH DIHEDRAL & INCIDENCE CHECKS IAW EMB 145 AMM 51-50-01. AIRCRAFT STILL IN C CHECK.SDR C2XA09TY068Fitting · chafedFRAME 75 FRETTING AT VERTICAL STAB FITTING. REMOVED FITTING CLEANED AREA AND DYE PEN INSPECTED, NO DEFECTS NOTED AND RE-INSTALLED FITTING IAW EC5310-01317. AIRCRAFT STILL IN C-CHECK.SDR WRLA2009109Channel · crackedDURING C-CHK IN TPE INSPECTION FOUND CRACK FROM VERT STAB ACCESS PNL 364FR. FOUND AFT FUSELAGE UPPER SKIN CHANNEL BOTH ENDS CRACKED AT STA 2065 BETWEEN X=13.65 AND X=-13.65 (REF EGAT NRC U05086). REPAIRED THE CHANNEL ON VERT STAB ACCESS PNL 364FR IAW MD-11F SDR COMA2009041350114Hinge Fitting · wornRUDDER ATTACH FITTING ON VERTICAL STAB CENTER BOTTOM HINGE BEARING HAS EXCESSIVE PLAY. REMOVED RUDDER CENTER LOWER HINGE FITTING, REMOVED AND REPLACED BEARING AND REINSTALLED FITTING PER EA 10-5531-02567.SDR IPXA09855434Structure · damagedINSPECTION TYPE:SV SURVEY SEQ 752-54-01 RT VERTICAL STAB REPAIR STA ZR 74.000 HAS FASTENER REPAIR. ACCOMPLISHED PER REO-G12648 AND EO DC8-5520-32835.SDR ASOA200900464Drag Angle · crackedVERTICAL STAB DRAG ANGLE DIAPHRAGM CRACKED 1.1 INCH LONG ON RT AFT SIDE UNDER RUDDER.SDR AALA20090413TUL03Lug · damagedVERTICAL STAB RIGHT INBOARD LUG DIAMETER IS OUT OF LIMITS. INSTALLED AND HONED NEW BUSHINGS PER SRM 55-02-00.SDR AALA20090413TUL21Structure · damagedVERTICAL STAB LEFT OUTBOARD LUG DIAMETER IS OUT OF LIMITS. INSTALLED AND HONED NEW BUSHINGS PER SRM 55-02-00.SDR AALA20090413TUL05Lug · damagedVERTICAL STAB RIGHT OUTBOARD LUG BORE DIAMETER IS OUT OF LIMITS. INSTALLED AND HONED NEW BUSHINGS PER SRM 55-02-00.SDR AALA20090413TUL20Structure · damagedVERTICAL STAB LEFT INBOARD LUG BORE DIAMETER IS OUT OF LIMITS. INSTALLED AND HONED NEW BUSHINGS PER SRM 55-02-00.SDR ASOA200900260Drag Angle · crackedLT VERTICAL STAB LOWER DRAG ANGLE CRACKED (MARKED). CRACK LENGTH WAS VERIFIED IAW SRM NDTM 51-20-006. LEFT VERTICAL STAB TO FUSELAGE DRAG ANGLE REPAIRED BY COMPLIANCE WITH EC/TC REO 670-55-31-018 IAW REO 670-55-31-018 FOR LEFT SIDE ONLY. RESTORED PROTECTIVE SDR DL757090290Angle · corrodedVERTICAL FIN ANGLE CORRORED AT STATION 1786.699 STA 0. REPAIRED BY REPLACEMENT PER 55-30-13 ON NR 01228.SDR ASOA200900213Drag Angle · crackedRT VERTICAL STABILIZER DRAG ANGLE VERIFIED CRACKED. REPAIRED PER REO 670-55-31-041.SDR SWAA090648Attach Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND LT VERTICAL STABILIZER ATTACH FITTING LUGS CORRODED. REPAIRED FITTING PER SRM.SDR SWAA090647Lug · corrodedDURING SCHEDULED 18Y CHECK, FOUND RT VERTICAL STABILIZER ATTACH FITTING LUGS CORRODED. REPAIRED FITTING PER SRM.SDR CALA2009012000050Bushing · corrodedVERTICAL STAB LEFT INBOARD AFT LUG BOTH BUSHINGS HAVE CORROSION. REMOVED AND REPLACED BOTH BUSHINGS REF BAC DWG 65-52274 AND SOPM 20-50-03.SDR CALA2009012000049Bushing · corrodedVERTICAL STAB RIGHT INBOARD AFT LUG BOTH BUSHINGS HAVE CORROSION. REMOVED AND REPLACED CORRODED BUSHINGS REF BAC DWR 65-52274 AND SOPM 20-50-03.SDR IPXA09855255Repair · damagedINSPECTION TYPE:SV VERT STAB L/E REPAIR HAS SIGNS OF WRINKLING AND DOES NOT MATCH L/E CONTOUR SS 752-S4-04, STA ZFS 104.750. REPAIRED PER DC8 SRM 55-2-1 FIG 4.SDR ASOA200801588Drag Angle · crackedRT VERTICAL FWD DRAG ANGLE APPEARS CRACKED. PERFORMED EDDY CURRENT INSPECTION OF RIGHT FORWARD VERTICAL STAB TO FUSELAGE DRAG ANGLE IAW CRJ 700 NDTM 51-20-006. DRAG ANGLE CONFIRMED CRACKED AND MARKED. RT DRAG ANGLE REPAIRED PER REO 670-55-31-018.SDR ASOA200801587Drag Angle · crackedLT VERTICAL FWD DRAG ANGLE APPEARS CRACKED. PERFORMED EDDY CURRENT INSPECTION OF LEFT FORWARD VERTICAL STAB TO FUSELAGE DRAG ANGLE IAW CRJ 700 NDTM 51-20-006. DRAG ANGLE CONFIRMED CRACKED AND MARKED. LT DRAG ANGLE REPAIRED PER REO 670-55-31-018. REMOVED PASDR CALA0801078Drag Angle · corrodedVERTICAL STABILIZER AFT LEFT ATTACH LUG AREA, FWD DRAG ANGLE FITTING HAS CORROSION INSIDE O/B HOLE. REMOVED LT VERTICAL STABILIZER AFT I/B AND O/B ATTACH BOLTS, REMOVED AND REPLACED LT DRAG ANGLE PER B737 SRM 51-40-02. REINSTALLED LT VERTICAL STABILIZER AFT SDR SWAA086162Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STABILIZER RT O/B FWD LUG FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA086163Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STABILIZER LT O/B FWD LUG FITTING CORRODED. REPAIRED FITTING PER SWA EA.SDR SWAA086066Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STABILIZER LT OUTBOARD REAR LUG FITTING CORRODED. REPAIRED FITTING PER EA.SDR KCSA081562Angle · crackedVERTICAL STAB, FIN STA 586 HAS A 5 INCH CRACK IN AN ANGLE THAT ATTACHES INTO THE FRONT SPAR WEB AT BL 0 TO RBL 5.SDR SWAA086007Drag Angle · corrodedDURING SCHEDULED 20Y CHECK, FOUND VERTICAL STAB FITTING DRAG ANGLES CORRODED. REMOVED AND REPLACED DRAG ANGLES PER SRM.SDR UPS08854002Structure · unknownINSPECTION TYPE:SV SSN 700-S4-02 RT SIDE VERTICAL STAB STATION 254 EXTERNAL REPAIR UNABLE TO VALIDATE. REPAIRED AS PER SRM 51-1-27.SDR UPS08854001Structure · misrepairedINSPECTION TYPE:SV VERTICAL STAB ZR254 EXTERNAL DOUBLER DOES NOT MEET SRM GUIDELINES. INSTALLED NEW ROW OF RIVETS 51-3-0 51-1-21.SDR ASOA200801361Drag Angle · crackedRT VERTICAL STAB DRAG ANGLE CRACKED. COMPLIED WITH REO 670-55-31-018. REMOVED FASTENERS AND CUT AWAY DAMAGED AREA IAW REO. RT SIDE FWD DRAG ANGLE, PER REO 670-55-31-018. PERFORMED EDDY CURRENT INSPECTION IAW NDTM 51-20-006. NO DEFECTS NOTED. FABRICATED DSDR ASOA1289Drag Angle · crackedREMOVAL & REPLACEMENT OF RT AFT DRAG ANGLE. CUT AWAY DAMAGED AREA. FURTHER DAMAGE FOUND TO AREA UNDERNEATH REMOVED AREA. REMOVED DAMAGE. REMOVED TOOLING MARKS IN UPPER FLANGE TO A DEPTH OF .002 AND .015 DEPTH SUBMIT TO BOMBARDIER FOR FURTHER DISPOSITION. SDR ASOA1296Drag Angle · crackedREMOVED & REPLACED AFT DRAG ANGLE ON VERTICAL STAB LEFT SIDE FAY SEALED AND APPLIED FINISH TO AREA. PERFORMED EDDY CURRENT INSPECTION OF FORWARD AND AFT V/STAB TO FUSELAGE DRAG ANGLES, RIGHT SIDE. FORWARD & AFT DRAG ANGLES VERIFIED CRACKED, FORWARD DRAG ANGLSDR ASOA1225Drag Angle · crackedPERFORMED EDDY CURRENT INSPECTION OF FORWARD AND AFT V/STAB TO FUSELAGE DRAG ANGLES, RIGHT SIDE. FORWARD AND AFT DRAG ANGLES VERIFIED CRACKED, FORWARD DRAG ANGLE IS MARKED AT THE END OF CRACK. REMOVED RT AFT DRAG ANGLE MADE TEMPLATE FOR AFT RT DRAG ANGLE (INSDR ASOA1224Drag Angle · crackedPERFORMED EDDY CURRENT INSPECTION OF FORWARD AND AFT V/STAB TO FUSELAGE DRAG ANGLES, LEFT SIDE. FORWARD AND AFT DRAG ANGLES VERIFIED CRACKED, FORWARD DRAG ANGLE IS MARKED AT END OF CRACK. REPAIR OF AFT DRAG ANGLE. REMOVED DAMAGED AREA FROM FWD DRAG ANGLE ANSDR 08FDEA03818Stiffener · crackedREAR STIFFENER BETWEEN THE TRAILING EDGE OF RIB 7 & THE RIB ON THE RIGHT SIDE OF THE VERTICAL STAB IS CRACKED. REMOVED & REPLACED STIFFENER IAW SRM 51-40-21 & 51-72-10.SDR TRAX200801106Drag Angle · crackedRT AFT V/STAB TO FUSELAGE DRAG ANGLE CRACKED AT 67.5% REAR SPAR DATUM.SDR TRAX200801105Drag Angle · crackedLT AFT V/STAB TO FUSELAGE DRAG ANGLE CRACKED AT 67.5% REAR SPAR DATUM.SDR TRAX200801097Drag Angle · crackedCRACKED DRAG ANGLE RT LOWER VERT STAB. MARKED.SDR TRAX200801096Drag Angle · crackedCRACKED DRAG ANGLE LT LOWER VERT STAB. MARKED.SDR 08FDEA02156Web · crackedAIR STAIR COMPARTMENT ABOVE "S" DUCT AT STA 1303, LT SIDE OF YELLOW VERTICAL WEB WHERE STIFFENER PASSES THROUGH CUT OUT, CRACKED. DOT ON AFT SIDE OF WEB AND ACCESS THROUGH VERT STAB PANEL 9504 REMOVED DAMAGE, FABRICATED, TREATED, PRIMED AND INSTALLED REPAIR PSDR SWAA082499Stiffener · crackedDURING SCHEDULED 12Y CHECK, FOUND VERTICAL STABILIZER STIFFENER AFT OF STABILIZER MOUNT CRACKED AT STA 1088. REMOVED AND REPLACED STIFFENER PER SRM.SDR 08FDEA01712Angle · crackedRIB NR 2 ATTACH ANGLE CRACKED AT STR 6R ATTACHMENT BOLT INSIDE VERTICAL STAB, STR 6R, RIB NR 2 FIN STA 22.5 CUT-OUT DAMAGED AREA IAW SRM 51-10-1 & 55-30-5 FIGURE 1, FABRICATED REPAIR ANGLE & REPAIR FILLER, TREATED & PRIMED PARTS IAW SRM 51-1-2, INSTALLED REPSDR TRAX200800457Structure · crackedSUSPECTED CRACK FWD OF FS 1181 ON LT VERTICAL BASE. COMPLIED WITH EC REO 670-55-31-032.
Back to JASC 5534