JASC 5730

Service difficulty reports · 27,279

Reports filed under 5730 · Wing, Plate/Skin, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5730'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA010544Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 641.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21.Jan 31, 2001 · N8091U · Doug DC871FSDR RRXA010543Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 635, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-1-2Jan 31, 2001 · N8091U · Doug DC871FSDR RRXA010542Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA 616.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 & 57-2-Jan 31, 2001 · N8091U · Doug DC871FSDR RRXA010540Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 213.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21Jan 31, 2001 · N8091U · Doug DC871FSDR RRXA010537Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 31, 2001 · N8091U · Doug DC871FSDR RRXA10797Panel · misdrilledDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO RT WING LWR FUEL TANK ACCESS PANEL AT PANEL 514I, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O.#01-006 WITH APPROVED 8110-3 DJan 30, 2001 · N801GP · Doug DC871FSDR RRXA010575Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT SIDE T/E FORMER AT STA ZFS 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010574Skin · damagedDURING A MAINTENANCE VISIT FOUND A BROKEN OUT BOLT HOLE ON THE TOP PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010573Former · crackedDURING A MAINTENANCE VISIT FOUND A 1" CRACK TO THE TOP I/B FORMER AT STA XS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ----------CX---------- (NO CRACK)Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010572Former · crackedDURING A MAINTENANCE VISIT FOUND A 8" CRACK TO THE TOP I/B FORMER AT STA XS 253, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010571Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE O/B BOTTOM T/E FORMER AT STA XFS 145, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010570Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE O/B TOP GUSSET ANGLE AT STA XFS 188.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-2Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010569Panel · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE BOTTOM SLOT PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW 51-1-22 AND 51-1-4.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010568Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES ON THE BOTTOM T/E BETWEEN STA XFS 85.000 TO STA XFS 91.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AJan 30, 2001 · N8091U · Doug DC871FSDR RRXA010567Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP FORMER AT STA XFS 448.581, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010566Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA 448.581, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010565Panel · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE BOTTOM SLOT PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010560Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT SIDE T/E FORMER AT STA ZFS 110, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR RRXA010559Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT SIDE T/E FORMER AT STA 104.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 30, 2001 · N8091U · Doug DC871FSDR AU010086Panel · failed(AUS) PANEL 551VB LOCATED ON LT WING LOWER SURFACE AFT OF THE LT MAIN LANDING GEAR MISSING A CENTRE SECTION APPROXIMATELY 6 FEET LONG.Jan 30, 2001 · Boeing 767338SDR TWAA0102302Skin · misrepairedDURING CHECK-C MAINT, A RT WING L/E BLIND RIVET REPAIR WAS FOUND INSTALLED ON L/E LOWER SURFACE AT INBOARD END OF FUEL SERVICE PANEL, STA X05250. REMOVED OLD REPAIR AND MADE NEW REPAIR DOUBLER AND INSTALLED WITH HI-LOKS PER SRM 57-06B, PAGE 9 FIG 3.Jan 30, 2001 · N903TW · Doug DC982SDR QXEA0100155Panel · crackedYYC- LEFT HAND FUEL PANEL 73A IS CRACKED. REPAIRED IAW HORIZON AIR EA 4-57-537.Jan 29, 2001 · N475AU · Fokker F28MK4000SDR USAA010071Skin · crackedCLT - FOUND SKIN CRACKED .875 INCH, FS 215, 2 INCHES FORWARD FRONT SPAR OUTBOARD MID SPAR ATTACH FITTING. REPAIRED PER EA 69037. (M)Jan 29, 2001 · N432US · Boeing 7374B7SDR USAA010072Skin · crackedCLT - FOUND SKIN CRACKED .75 INCH, LOWER LEFT WING SURFACE PYLON AFT ENGINE MOUNT OUTBOARD WBL 198. REPAIRED PER EA 69037. (M)Jan 29, 2001 · N432US · Boeing 7374B7SDR RRXA010652Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE ABOVE THE L/H FLAP TRACK FITTING & MILL STOP AT STA 5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 5Jan 26, 2001 · N8091U · Doug DC871FSDR RRXA010650Skin · damagedDURING A MAINTENANCE VISIT FOUND SCREWS PULLING THROUGH SKIN ON THE SLOT VANE I/B END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.Jan 26, 2001 · N8091U · Doug DC871FSDR RRXA010639Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 442.185, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 26, 2001 · N8091U · Doug DC871FSDR RRXA010634Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN REPAIR STRAP ON THE O/B SLOT VANE AT STA XS 520.168, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.Jan 26, 2001 · N8091U · Doug DC871FSDR IXXA0100015Skin · crackedDURING ROUTINE C-CHECK INSPECTION, A CRACK WAS DETECTED ON LEFT WING OUTER WING SKIN PANEL AT STATION XRS 533.3, STRINGER 62 END FITTING. REPAIR ACCOMPLISHED REMOVAL OF DAMAGED AREA. FABRICATION AND INSTALLATION AN REPAIR FILLER, DOUBLER AND TRIPLER IN ACCORJan 26, 2001 · N827BX · Doug DC871FSDR EIA2001024Butt Joint · corrodedHKG-HAECO - FOUND M/D WING CENTER SECTION UPPER SKIN SURFACE BUTT JOINT CORRODED AT BS 1140 LBL 75 - LBL 92. REMOVED CORROSION, NDT INSPECTED, REWORKED AND REPROTECTED AREA. WITHIN SRM LIMITS PER BOEING MSG EVR-HKG-01-00004H AND RS R-57-14-34584. (M)Jan 26, 2001 · N481EV · Boeing 747132SDR EIA2001023Butt Joint · corrodedHKG-HAECO - FOUND M/D WING CENTER SECTION UPPER SKIN SURFACE BUTT JOINT CORRODED AT BS 1140 LBL 11 TO RBL 11. CORROSION REMOVED, NDT INSPECTED, AREA REWORKED AND REPROTECTED, WITHIN SRM LIMITS PER BOEING MSG EVR-HKG-01-00005H AND RS R-57-14-34583. (M)Jan 26, 2001 · N481EV · Boeing 747132SDR RRXA10844Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO NR 2 ENGINE STUB WING SKIN AT STA. XFS 238, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-006 WITH APPROVED 8110-3 DATEJan 25, 2001 · N801GP · Doug DC871FSDR RRXA10843Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO 2 ENGINE STUB WING SKIN AT STA. XFS 238, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20C AND E.O. 01-006 WITJan 25, 2001 · N801GP · Doug DC871FSDR RRXA010649Panel · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE BOTTOM SLOT PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010648Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE UPPER I/B ATTACH FITTING ON THE L/H UPPER INSIDE TANK OF 506A O/B AT STA XRS 428, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATJan 25, 2001 · N8091U · Doug DC871FSDR RRXA010647Stringer · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CLIP ON STR #51 L/H UPPER INSIDE TANK OF 506A O/B BETWEEN STA XRS 428 LWR STRINGER CLIP BETWEEN LWR REAR SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IJan 25, 2001 · N8091U · Doug DC871FSDR RRXA010646Stringer · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CAN'T #54 STRINGER AT L/H UPPER INSIDE TANK OF 505B BETWEEN STA XRS 495-508, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARJan 25, 2001 · N8091U · Doug DC871FSDR RRXA010645Stringer · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CAN'T #55 LOWER STRINGER ON THE L/H UPPER WING INSIDE TANK OF 505B O/B BETWEEN STA XRS 495 & 508, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 5Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010644Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON INTERNAL SKIN AT TOP DE-ICER VENT HOLES AT STA 422.750 TO XFS 335.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ----------CX----------Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010643Doubler · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ABOUT 3" AT T/E ON THE BOTTOM DOUBLER AT STA XFS 195, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 5Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010642Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA 316.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010641Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 329, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARTS AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010640Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 366.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010638Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 448.581, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010637Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 461.372, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010636Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 478.897, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 57-2-0.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010635Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES AT STA XS 520.166, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-1.Jan 25, 2001 · N8091U · Doug DC871FSDR RRXA010633Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES TO THE SKIN AT STA 304, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-1.Jan 25, 2001 · N8091U · Doug DC871FSDR UIEA01002Skin · corrodedDURING THE RECENT C-CHECK, THE R/W EXTERNAL SKIN WAS CORRODED AT WS 320 COMMON TO STRINGER 15 AND WBL 179. CORROSION REMOVED, AREA BLENDED, TREATED AND REFINISHED IAW 57-30-01 FIG 2. (M)Jan 25, 2001 · N507MC · Boeing 747230BSDR UPS01834815Doubler · crackedINSPECTION TYPE:C1&3, LEFT WING L/E LOWER INTERNAL DOUBLER IS CRACKED AT XFS 597.5. REMOVED, FABRICATED AND REPLACED DOUBLER IAW DWG 5769600, AND SRM 51-1-20D, 51-1-21.Jan 25, 2001 · N701UP · Doug DC871F
Back to JASC 5730