SDR UF6A991109Np Gauge · failedORD - FLT 5723 - THE NR 1 NP GAUGE IS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE GAUGE. SYSTEM OPS CHECKED GOOD. (M)SDR CA971106008Compressor Vane · ecam message(CAN) NR 1 ENGINE COMPRESSOR VANE MESSAGE ON ECAM. TAKEOFF ABORTED AT 80 KNOTS. MAINTENANCE ACTION PERFORMED NR 1 ENGINE FULL AUTHORITY DIGITAL ENGINE CONTROL TEST AND POWER ASSURANCE RUN, NO FAULT FOUND. INSPECTED AIRCRAFT TIRES AND BRAKES, NO FAULT FOUND. SDR AU961122Computer · contam-water(AUS) AREA ABOVE E3 AND E4 ELECTRONICS PACK CONTAMINATED BY WATER DURING HEAVY RAIN STORM - RIGHT EICAS COMPUTER ALSO CONTAMINATED BY WATER