Aerospatiale AS350BA
Service difficulty reports · 958
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'AS350BA' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'AS350BA' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA021016013Tach Generator · failed(CAN) BLEED VALVE DOES NOT CLOSE WHEN REQUIRED. FAULTY TACH BOX REPLACED WITH AIRWORTHY PART. NO FURTHER PROBLEMS.SDR CA020801013Firewall · cracked(CAN) A CRACK WAS FOUND ON FIREWALL DURING MAINTENANCE OPERATION. LENGTH OF CRACK 3.75 PO. AN ENGINE AIR FILTER KIT HAS RECENTLY BEEN INSTALLED AS PER STC SH02-22 BASED ON FAA APPROVED STC: SR01049SE. A PART OF THIS MODIFICATION CONSIST OF INSTALLATION A DIFSDR CA021016012Tach Generator · failed(CAN) BLEED VALVE OPEN IN FLIGHT ABOVE 97 PERCENT NG AND ON LANDING. FAULTY TACH BOX REPLACED WITH AIRWORTHY PART. NO FURTHER PROBLEMS.SDR AUS20020749Igniter · unserviceable(AUS) ENGINE IGNITER CENTRE ELECTRODE MISSING. IMPACT DAMAGE ON FIRST STAGE TURBINE AND FREE TURBINE BLADES.SDR CA021016011Tach Generator · failed(CAN) BLEED VALVE OPEN IN FLIGHT ABOVE 97 PERCENT NG AND ON LANDING. FAULTY TACH BOX REPLACED WITH AIRWORTHY PART. NO FURTHER PROBLEMS.SDR CA020729012Igniter · failed(CAN) DURING MAINTENANCE, ENGINEER REMOVED IGNITERS FOR INSPECTION, ONE ELECTRODE WAS MISSING. CARRIED OUT SL. 2170 (BORESCOPE INSPECTION ) FOUND INTERNAL DAMAGE TO ENGINE. ENGINE WAS REPLACED.SDR KBMA117654Motor · inoperativeFORWARD EVAPORATOR, INOPERATIVE. REPLACED WITH NEW MOTOR.SDR KBMA117646Lock · inoperativeRIGHT SLIDING DOOR DOES NOT LATCH. REMOVED AND REPLACED WITH NEW CYLINDER LOCK.SDR KBMA117645Indicator · inoperativeTORQUE GUAGE INOPERATIVE. REMOVED AND REPLACED WITH SERVICEABLE UNIT.SDR CA021016004Bleed Valve · failed(CAN) BLEED VALVE LIGHT STAYS ON, VALVE STAYS OPEN IN FLIGHT. BLEED VALVE REPLACED WITH AIRWORTHY PART, DEFECT CORRECTED.SDR CA021016015Exciter · intermittent(CAN) IGNITION INTERMITTENT FROM ONE IGNITION CHANNEL. FAULTY HIGH ENERGY GENERATOR REPLACED WITH NEW PART, STARTS CORRECTED.SDR KBMA117636Blower · inoperativeOIL COOLER BLOWER WAS INOPERATIVE. REPLACED WITH OVERHAULED BLOWER FAN.SDR CA021016016Exciter · intermittent(CAN) POOR IGNITION ON ENGINE STARTS. FAULTY HIGH ENERGY GENERATOR REPLACED WITH NEW PART, STARTS CORRECTED.SDR KBMA117635Gyro · inoperativeDIRECTIONAL GYRO COMPLETELY INOPERATIVE. NON RESPONSIVE WITH POWER APPLIED. REPLACED WITH OVERHAULED UNIT.SDR KBMA117639Guide · wornNR 5 INNER FLANGE GUIDE WAS WORN. REPLACED WITH NEW GUIDE.SDR KBMA117631Bearing · wornNR 1 AND NR 4 TAIL ROTOR CONTROL TUBE FLANGE GUIDE BEARINGS, WORN. REPLACED WITH NEW.SDR CA021016014Valve · failed(CAN) ENGINE FAILED TO START. MAXIMUM NG ATTAINED - 40 PERCENT. START ELECTROVALVE REPLACED WITH AIRWORTHY PART, START CORRECT.SDR KBMA117621Fuse · failedNO POWER WHEN BATTERY SWITCH IS DEPRESSED. REPLACED 50 AMP FUSE.SDR KBMA117616Switch · inoperativeHORN LIGHT WOULD NOT EXTINGUISH. REPLACED WITH SERVICEABLE HYDRAULIC CUTOFF SWITCH.SDR CA021016017Pump · failed(CAN) LOW FUEL PRESSURE INDICATED. FUEL BOOST PUMP GROWLING, LOW OUTPUT, PRESSURE AND VOLUME CONFIRMED. PUMP REPLACED WITH AIRWORTHY UNIT.SDR KBMA117628Bushing · wornNR 3 TAIL ROTOR DRIVE SHAFT OUTER RUBBER BUSHING WORN. REPLACED WITH NEW.SDR KBMA117629Bearing · wornTAIL ROTOR CONTROL, PUSH/PULL TUBE BEARING EXCESS LIMIT. REPLACED BUSHINGS WITH NEW.SDR KBMA117620Wire · brokenA/C WILL NOT ACCEPT APU POWER. REPAIRED BROKEN WIRE PG/NE INOPERATIVE IN AFT BAGGAGE COMPARTMENT.SDR KBMA117633Switch · inoperativeTAXI LIGHT SWITCH INOPERATIVE. REPLACED WITH NEW SWITCH.SDR KBMA117634Socket · brokenFUSE HOLDER BROKEN. REPLACED WITH SERVICEABLE ITEM.SDR KBMA117612Bleed Valve · stickingBLEED VALVE WAS STICKING. REMOVED AND REPLACED WITH SERVICEABLE UNIT.SDR KBMA117617Compressor · inoperativeAIR CONDITIONER BELT MELTED. REMOVED AND REPLACED COMPRESSOR WITH OVERHAULED UNIT.SDR KBMA117632Bleed Valve · sticksBLEED VALVE STICKS OPEN. REPLACED WITH SERVICEABLE BLEED VALVE.SDR KBMA117614Intake · crackedAIR INTAKE WAS CRACKED ON UPPER SIDE. REPLACED WITH REPAIRED SERVICEABLE UNIT.SDR KBMA117618Display · malfunctionedDIGITAL DISPLAY FLICKERING. REPLACED WITH SERVICEABLE UNIT.SDR KBMA117606Relay · defective25 AMP AIR CONDITIONER CIRCUIT BREAKER POPS IN FLIGHT. REMOVED AND REPLACED 7 INCH BLOWER, STILL POPS. REPLACED 2 EACH RELAYS, OPS CHECK GOOD.SDR KBMA113850Bleed Valve · malfunctioned(BLEED VALVE) BLEED VALVE IS NOT OPENING OR CLOSING. REPLACED WITH SERVICEABLE UNIT.SDR KBMA113851Electrical Box · failed(MASTER ELECTRICAL BOX) GENERATOR WILL NOT COME ON LINE. REPLACED WITH SERVICEABLE UNIT.SDR KBMA117604Rod · missing(ROD) FORWARD PASSENGER DOOR LOWER LATCH ROD MISSING OR BROKEN. REINSTALLED ROD FOR LOWER LATCH.SDR KBMA113849Seal · leaking(STARTER/ GENERATOR SEAL) EXCESSIVE LEAKING. REPLACED WITH NEW SEAL.SDR KBMA113848Pump · inoperativeBOOST PUMP INOPERATIVE. REPLACED WITH OVERHAULED UNIT.SDR KBMA113841Servo · inoperativeCYCLIC PULLS TO THE LEFT. REPLACED WITH SERVICEABLE SERVO.SDR KBMA113842Fire Detector · contaminatedFIRE LIGHT STAYS ON/ FIRE DETECTOR SOAKED WITH OIL . DEGREASED FIRE DETECTOR.SDR KBMA113832Switch · stuckGENERATOR SWITCH STICKS. REMOVED AND REPLACED WITH SERVICEABLE UNIT.SDR KBMA113829Electrical Box · failedGENERATOR LIGHT ON AND WAS UNABLE TO RESET. REPLACED WITH SERVICEABLE UNIT.SDR KBMA113835Spar · crackedTAIL ROTOR BLADE SPAR IS CRACKED. REPLACED WITH SERVICEABLE TAIL ROTOR BLADE.SDR KBMA113837Clamp · broken(STRAP) HEAT SHIELD STRAP IS BROKEN. REPLACED WITH SERVICEABLE PARTS.SDR KBMA113826Line · wornP2 LINE WAS WORN BEYOND LIMIT. REPLACED WITH NEW P2 LINE.SDR KBMA113825Bushing · wornFORWARD COUPLING DISC ASSEMBLY, BUSHING WAS WORN OUT. REMOVED AND REPLACED WITH A NEW DISC ASSEMBLY.SDR KBMA113824Ignition Lead · wornIGNITION LEADS, WORN. REPLACED WITH SERVICEABLE LEADS.SDR CA020507005Belt · broken(CAN) DURING START UP (3RD OF DAY) PILOT REPORTED HYD WARNING LIGHT DID NOT GO OUT. CYCLIC & ANTI-TORQUE PEDALS HAD NO HYDRAULIC ASSIST. A/C SHUTDOWN NORMALLY. INSP REEALED HYDRAULIC BELT P/N 704A3369004 WAS BROKEN. BREAKAGE SEEMS TO BE NEAR END OF DIRECTION SDR AUS20020383Bleed Valve · malfunctioned(AUS) PILOT REPORTED CHANGES IN ENGINE PERFORMANCE WITH DECREASE IN ENGINE TORQUE AND INCREASE IN COMPRESSOR RPM. SUSPECT A RECENTLY FITTED COMPRESSOR BLEED VALVE WAS INCORRECTLY SET-UP AT OVERHAULFOR MODULATION POINT OPERATION.SDR KBMA113814Compressor · faultyA/C COMPRESSOR REPORTED TO BE FAULTY. REPLACED WITH SERVICEABLE UNIT.SDR KBMA113803Transponder · inoperativeTRANSPONDER NOT GIVING REPLY LIGHT OR IDENTY. REPLACED WITH SERVICEABLE UNIT.SDR KBMA113801Belt · brokenAIR CONDITIONER BELT BROKE OFF. REPLACED WITH NEW.
Back to Aerospatiale AS350BA