Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200600142Floor Panel · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR PANEL 262FF BY R2 DOOR. REPLACED FLOOR PANEL 262FF PER WORK CARD CP753-36.SDR F3LA200600140Floor Panel · corrodedDURING C-4 CHECK, INSPECTION REPORTED FLOOR PANEL 222FF CORRODED ON BOTTOM CORNER. REMOVED AND REPLACED FLOOR PANEL 222FF PER WORK CARD CP753-12.SDR F3LA200600143Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORRODED FLOORBEAM FASTENER HOLE AT Y1292, CROSSBEAM FS 68, RT SIDE AFT FUSELAGE. FOUND FLOORBEAM TO BE OUT OF LIMITS PER SRM 53-00-14. REMOVED AND REPLACED FLOORBEAM AT Y1292 FROM FS 66 TO FS 68 PER SRM'S 51-42-11, 51-4SDR F3LA200600136Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE LT FLOORBEAM FASTENER HOLES CORRODED AT Y1292, BETWEEN FS 69 AND FS 70. REMOVED CORROSION ON FLOORBEAM AND FOUND FLOORBEAM TO BE OUT OF LIMITS PER SRM 53-00-14, FIG 102. REMOVED AND REPLACED FLOORBEAM BETWEESDR F3LA200600131Stand Off · corrodedDURING C-4 CHECK, INSPECTION REPORTED DAMAGED STANDOFF ON AFT BULKHEAD RT FLOORBEAM, Y1732 AT CROSSBEAM FR66. FOUND DAMAGE TO BE OUT OF LIMITS PER SRM 53-00-14, FIG 102. REMOVED CORROSION FROM SILL BEAM AT FR66 PER SRM 53-41-14 FIG 201. FABRICATED AND INSTASDR F3LA200600130Shear Web · corrodedDURING C-4 CHECK, INSPECTION REPORTED HEAVY CORROSION ON AFT FUSELAGE RT FLOORBEAM SHEAR PLATE WEB AT Y1292 (BETWEEN CROSSBEAMS FR69 AND FR70). FOUND CORROSION ON SHEAR PLATE AND ANGLED WEB TO BE OUT OF LIMITS PER SRM 51-11-15. REMOVED DAMAGED SHEAR PLATE ANSDR F3LA200600129Shear Web · corrodedDURING C-4 CHECK, INSPECTION REPORTED HEAVY CORROSION ON AFT FUSELAGE LT FLOORBEAM SHEAR PLATE WEB AT Y1292 (BETWEEN FRAMES FR69 AND FR70). FOUND CORROSION ON SHEAR PLATE WEB TO BE BEYOND REPAIR LIMITS PER SRM 53-41-14. REMOVED DAMAGED SHEAR PLATE AND SUPPORSDR F3LA200600139Bolt · corrodedDURING C-4 CHECK, INSPECTION REPORTED FLOOR MOUNTING BOLTS ON AFT LT FLIGHT ATTENDANT SEAT CORRODED. REPLACED FLOOR MOUNTING BOLTS PER SICMA CMM 25-11-97 AND CMM 25-11.SDR F3LA200600124Gust Lock · inoperativeFOUND GUST LOCK 1L INOP. ADJUSTED BUFFER PER AMM 52-11-12-820. RII INSPECTION ACCOMPLISHED. AIRCRAFT RELEASED FOR SERVICE.SDR F3LA200600123Control Servo · faultedFLIGHT CREW REPORTED FOLLOWING ECAM: (WHEEL N/W STRL FAULT), AT CRUISE THROUGH LANDING. PRIOR TO LANDING AT SFO, A FLY-BY WAS PERFORMED TO ENSURE THE NOSE WHEEL WAS ALIGNED CORRECTLY. AN EMERGENCY WAS DECLARED UPON LANDING IN SFO AND AIRCRAFT LANDED WITHOUT SDR F3LA200600120Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED L2 DOOR THRESHOLD FLOORBEAM AT Y1732 AND FRAME 68 CORRODED ABOVE NUT PLATE. CORROSION DAMAGE ON DOOR SILL BEAM WAS FOUND TO EXCEED 50 PERCENT OF THE DEPTH OF THE BEAM AT THE NUT PLATE LOCATION. DAMAGE WAS FOUND TO BE OUTSDR F3LA200600106Fuel Filter · cloggedAIR TURNBACK. FLIGHT CREW REPORTED ECAM AFTER TAKEOFF: ENG1-FUEL FILTER CLOG. REPLACED NR 1 ENGINE FUEL FILTER IAW TSM 73-00-00-810-875, AMM 73-11-10-000-004, AMM 73-11-10-210-003, AND AMM 73-11-10-400-004. ALL SYSTEMS CHECKED NORMAL. PERFORMED LEAK CHECK SDR F3LA200600118Plate · corrodedDURING C-4 CHECK, INSPECTION REPORTED R1 DOOR FWD GIRT BAR FITTING ATTACH PLATE CORRODED. REPLACED FWD GIRT BAR PLATE ASSY. IAW SRM 51-42-11 AND AMM 20-21-11.SDR F3LA200600122Cover · corrodedDURING C-4 CHECK, INSPECTION REPORTED L2 DOOR FLOORBOARD ACCESS COVER PLATE CORRODED ON LWR SIDE. COVER PLATE WAS FOUND TO BE OUT OF LIMITS PER SRM 53-41-14. FABRICATED AND INSTALLED NEW COVER PLATE PER SRM 51-44-11, AIRBUS DRAWING 10D53670092, AND SRM 51-75SDR F3LA200600117Plate · corrodedDURING C-4 CHECK, INSPECTION REPORTED R2 DOOR FWD GIRT BAR PLATE CORRODED. REPLACED FWD GIRT BAR PLATE IAW AMM 52-13-31-400-003. SEALED AREA AROUND FWD PLATE AT R2 DOOR IAW AMM 52-13-31-400-007.SDR F3LA200600121Web · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR WEB OB AND AFT OF BEAM AT FR69 AND Y1292. REMOVED FLOOR WEBS IAW SRM 51-42-11. FOUND UPPER WEB TO BE OUT OF LIMITS AND LOWER WEB TO BE WITHIN LIMITS IAW SRM 53-00-14. PERFORMED PANAMETRIC ULTRASONIC TSDR F3LA200600116Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM (LONGERON) FWD OF FR68 AT Y1292. BLENDED OUT CORRODED AREA ON FLOORBEAM AND FOUND AREA TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102. REMOVED AND REPLACED FLOORBEAM FROM FR66 TO FR68 IAW SRM 51-42SDR F3LA200600113Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR SUPPORT IB OF L2 AT Y1292 FROM FR66 TO FR68 AT HOLES. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 51-00-14. REMOVED AND REPLACED FLOORBEAM FROM C64 TO C69 IAW SRM'S 51-42-11 AND 51-44-11.SDR F3LA200600108Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AFT OF L2 DOOR CUTOUT AT FR68 TO FR69, Y1292. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS PER 53-00-14. REMOVED AND REPLACED FLOORBEAM FROM C64 TO C69 PER SRM'S 51-42-11 AND 51-44-11.SDR F3LA200600104Line · crackedDURING START IN DCA, APU EXPERIENCED AN AUTO SHUTDOWN WITH SUBSEQUENT FIRE BOTTLE DISCHARGE. INSPECTED TAILCONE, APU AND ACCY COMPARTMENT IAW AMM 05-23-10-200-003. FOUND A CRACKED APU TURBINE BEARING RETURN LINE AND EVIDENCE OF FIRE IN THE APU ASSY. (APU IS ASDR F3LA200600115Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM (LONGERON) JUST AFT OF FR68 AT Y1292. BLENDED CORRODED AREA ON FLOORBEAM AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102. REMOVED AND REPLACED FLOORBEAM FROM FR68 TO FR69 IAW SRM 51-42-11.SDR F3LA200600112Mount · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON LAV MOUNT HOLE AT Y1292, FR16, IN FWD LAV AREA. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REPAIRED DAMAGED AREA IAW SRM'S 53-00-15, FIG.202(A)(B)(C)(D), 53-11-15, FIG. 202 (ITEM 5), 53-11SDR F3LA200600111Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CABIN FLOORBEAM AT FR66 IB OF L2 DOOR CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED AND REPLACED FLOORBEAM FROM C64 TO C69 IAW SRM 51-42-11, 51-42-11, AND 51-44-11.SDR F3LA200600110Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT Y503.2 (LT SIDE) BETWEEN FR 14 AND FR16. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS PER SRM 53-11-14. REPLACED FLOORBEAM PER SRM 51-42-12.SDR F3LA200600109Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM AT Y1292, FR20. FOUND CORROSION OUT OF LIMITS SRM 53-11-14. REPLACED FLOORBEAM IAW SRM 51-42-11, 51-42-12, AND 53-11-15.SDR F3LA200600119Bolt · corrodedDURING C-4 CHECK, INSPECTION REPORTED FWD LAV MOUNT BOLT IN EE BAY CORRODED. REPLACED LAV MOUNT BOLT IAW W/C CP725-13.SDR F3LA200600103Relay · failedRE-ISSUED. FLIGHT CREW REPORTED EMERGENCY EXIT LIGHTS ILLUMINATED IN-FLIGHT FOR UNKNOWN REASON. TROUBLESHOT SYSTEM PER TSM 335100810819. REPLACED RELAY 8WL/108VU CTL PWR SUPPLY. PERFORMED EMERGENCY LIGHTING OPS TEST PER AMM 33-51-00-710-001. TESTED NORMSDR F3LA200600086Light · failedEPSU TEST FAILED IAW HEAVY CHECK WORK CARD. REPLACED RT OVERWING EXIT HATCH HANDLE LIGHT IAW MM 23-73-47, PB 401 AND 33-51-11-420-052A, PERFORMED ANOTHER EPSU TEST AND CHECKED GOOD.SDR F3LA200600085Mask · no testDURING C-2 CHECK, INSPECTION REPORTED MASK BOX OVER L1 DOOR (40WR) DID NOT DROP. REPACKED O2 MASKS OVER L1 DOOR AND OPS CHECKED IAW AMM 35-23-00-720-454. CHECKED GOOD.SDR F3LA200600083Epsu · no testDURING C-2 CHECK, INSPECTION REPORTED FWD LT EPSU (EMERGENCY POWER SUPPLY UNIT) FAILED TEST. REPLACED LT FWD EPSU AND PERFORMED OPERATIONAL CHECK. TESTED GOOD.SDR F3LA200600082Wire · maint errorDURING C-2 CHECK, PRE-RECORDED ANNOUNCEMENT DID NOT COME ON DURING OXYGEN MASK DROP TEST. FOUND PRE-RECORDED ANNOUNCEMENT OUTPUT WIRES CAPPED & STOWED, LIVE TV WIRES IN THEIR PLACE. WIRE 2332-5811 CAPPED & STOWED AT CONNECTOR 166VCA, SHIELDED PAIR WIRE 2332-SDR F3LA200600081Psu · failedDURING C-2 CHECK, INSPECTION REPORTED THE PASSENGER OXYGEN MASK DOOR AT ROW 7 ABC DID NOT OPEN DURING TEST. REPLACED PASSENGER OXYGEN CONTAINER ASSY PER AMM 35-21-41, PB 401, AND 35-21-41-481-050.SDR F3LA200600080Rivet · shearedDURING C-2 CHECK, INSPECTION REPORTED A RIVET HEAD SHEARED OFF AT LT SIDE FWD A/C BAY, FWD LOWER CORNER WEB AT ZONE 191, I/B SIDE OF WEB, LOCATED O/B OF EMERGENCY RAM AIR CONNECTOR. REPLACED SHEARED RIVET PER A319 SRM 51-42-11.SDR F3LA200600079Circuit Breaker · meltedCIRCUIT BREAKER (LGCIU NR 2) ARCED AND MELTED. REPLACED CIRCUIT BREAKER PER ASM32-31-00, SCH 06, PG 10 AND AMN 32-69-00-740-001.SDR F3LA200600069Attach Bracket · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR PANEL 261EF ATTACHMENT BRACKET (AFT END). CORROSION WAS FOUND TO BE OUT OF LIMITS PER A319 DRAWING 10 D536 70099. FABRICATED AND INSTALLED NEW SPLICE PLATE PER A319 DRAWING 10 D536 70099, SRM 51-44-11 SDR F3LA200600073Closeout Panel · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT L2 DOOR CLOSEOUT SECTION, LOWER LEG. REMOVED CORROSION AND FOUND AFT L2 DOOR CLOSEOUT SECTION TO BE UNREPAIRABLE PER A319 SRM 53-41-12. REPLACED L2 DOOR AFT CLOSEOUT SECTION PER A319SRM 51-42-11 AND 51-4SDR F3LA200600066Floor Panel · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION AND DELAMINATION ON BOTTOM SURFACE OF L1 ENTRYWAY FLOOR PANEL 221FF AT FWD AND AFT SIDES. REPLACED FLOOR PANEL PER AMM 53-12-12-991-003.SDR F3LA200600065Floor Panel · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON BOTTOM SURFACE OF R1 ENTRYWAY FLOOR PANEL 222FF AT FWD AND AFT SIDES. REPLACED FLOOR PANEL 22FF PER AMM 53-12-12-991-003.SDR F3LA200600061Floor Panel · corrodedDURING C-4, INSPECTION REPORTED TIE PLATE FOR FWD GALLEY FLOOR PANEL CORRODED. FABRICATED AND INSTALLED TIE PLATE PER SRM 53-02-00 AND DRAWING B5-D536-10763SDR F3LA200600060Plate · corrodedDURING C-4 CHECK, INSPECTION REPORTED TIE PLATE CORRODED FOR G-1 GALLEY FLOOR. FABRICATED AND INSTALLED TIE PLATE PER SRM 53-11-14, PARA 5.B TABLE.SDR F3LA200600056Odor · detectedFLIGHT CREW REPORTED A BURNING SMELL, STRONG ELECTRICAL ODOR BRIEFLY WHILE DESCENDING THRU FL190. NO VISIBLE SMOKE OBSERVED. ODOR WAS ONLY NOTICED BY COCKPIT CREW. INSPECTED AIRCRAFT PER TSM 24-00-00-810-823 FOR DAMAGE. NO DAMAGE FOUND. PERFORMED TROUBLESSDR F3LA200600075Girt Bar · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION AROUND L2 DOOR FWD GIRT BAR FITTING. REMOVED STRUCTURE AROUND GIRT BAR ATTACH POINT, FOUND CORROSION ON ATTACH FASTENERS AND ON THE L2 SILL. REMOVED CORROSION ON GIRT BAR ATTACH POINT PER SRM 51-42-11. LOCATEDSDR F3LA200600067Bolt · corrodedDURING C-4 CHECK, INSPECTION REPORTED LT MLG TORSION LINK UPPER GUIDE PIN BOLT CORRODED. REPLACED UPPER TORQUE LINK BOLT PER AMM 32-11-27-400-001.SDR F3LA200600064Dummy Rail · corrodedDURING C-4 CHECK, INSPECTION REPORTED MAJOR CORROSION ON DUMMY RAIL AT STATION Y503.2 BETWEEN FR13 AND FR16. CORROSION WAS FOUND TO BE OUT OF LIMITS PER SRM 53-11-14, FIG 101. REPLACED DUMMY RAIL PER SRM 51-42-11 AND SRM 51-44-11.SDR F3LA200600078Guide Vane · crackedDURING C-4 CHECK, INSPECTION REPORTED CRACKS ON PLATFORM OF RT ENGINE OUTLET GUIDE VANES AT THE 5 O'CLOCK, 6 O'CLOCK, 7 O'CLOCK AND 8 O'CLOCK POSITIONS. REPLACED DAMAGED OUTLET GUIDE VANES (2 EA AT EACH POSITION) PER AMM 72-23-00-000-008 AND 72-23-00-400-008.SDR F3LA200600077Crossbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON CROSSBEAM AT BS 1292 BETWEEN FR67 AND FR68. FOUND CROSSBEAM TO BE UNREPAIRABLE PER SRM 53-00-14, FIG 102. REMOVED BEAM FRAME 66-68 PER SRM 51-42-11. INSTALLED NEW CROSSBEAM PER SRM 51-44-11 AND 51-4SDR F3LA200600076Crossbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON CROSSBEAM AT BS Y1292 BETWEEN FR68 AND FR69. FOUND CROSSBEAM TO BE OUT OF LIMITS PER SRM 53-00-14 FIG 102. REMOVED FRAME PER SRM 51-42-11. TRANSFERRED EXISTING PARTS FROM ORIGINAL BEAM TO NEW BEAM PSDR F3LA200600074Drain Pan · corrodedDURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON PAN AFT OF R2 DOOR CUTOUT BETWEEN FR69 AND FR70. FOUND TO BE BEYOND REPAIR PER SRM 51-42-11. REMOVED AND REPLACED PAN PER SRM 51-42-11, 51-44-11, 53-41-14 AND 51-43-00.SDR F3LA200600072Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED SURFACE CORROSION ON FRAME SUPPORT AFT OF R2 DOOR CUTOUT BETWEEN FR69 AND FR70 (BOTTOM SIDE). REMOVAL OF THE PAN ABOVE SUPPORT REVEALED SUBSTANTIAL CORROSION BENEATH SUPPORT. REMOVED AND REPLACED FRAME SUPPORT AFT OF R2 SDR F3LA200600070Guide Vane · crackedDURING C-4 CHECK, INSPECTION REPORTED THE NR 2 ENGINE OUTLET GUIDE VANES AT THE 1 O'CLOCK, 2 O'CLOCK, 3 O'CLOCK, 4 O'CLOCK, 10 O'CLOCK, 11 O'CLOCK AND 12 O'CLOCK POSITIONS HAD CRACKS ON PLATFORMS PER AMM 72-23-00-991-310-06, SHEET 603. REPLACED DAMAGED OUTLET
Back to Airbus A319-111