Airbus A319-112

Service difficulty reports · 16,098

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'A319112'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR F3LA201911270144Apu · leakingLP1142467 ITEM 1 & 2 DISCREPENCY --- AT APPROX 10 MI FINAL, STRONG ODOR WAS SMELLED IN FLIGHT DECK. UPON LANDING PACK 1 WAS TURNED OFF WITH LITTLE CHANGE NOTED PACK 2 WAS TURNED OFF AND SMELL EVENTUALLY DISIPATED MOSTLY FLIGHT ATTENDANTS SAID THEY MIGHT HAVE SNov 23, 2019 · N910FR · Airbus A319112 · Airborne Auxiliary Power Unit (APU) SystemSDR AALA201911259008Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR CYLINDER PRESSURE LOW. MAINTENANCE SERVICED DOOR CYLINDER TO PROPER PRESSURE PER AMM 52-10-00.Nov 22, 2019 · N742PS · Airbus A319112 · Passenger/Crew DoorsSDR ASAA2019121983636Shear Plate · corrodedAFT WET AREA RH LATERAL SHEAR PLATE AT FR69-FR70 STR23 HAS CORROSION GROUNDED - YES. NO CORROSION LIMTS GIVEN FOR SHEAR PLATE IN A319. REMOVED AND REPLACED SHEAR PLATE P/N D5347112420300 IAW A319 SR, 51-42-113Nov 18, 2019 · N526VA · Airbus A319112 · Fuselage Miscellaneous StructureSDR ASAA2019121983635Shear Plate · corrodedAFT WET AREA LH LATERAL SHEAR PLATE AT FR69-FR70 STR23 HAS CORROSION GROUNDED - YES. NO CORROSION LIMITS GIVEN FOR SHEAR PLATE IN A319 SR,. REMOVED AND REPLACED SHEAR PLATE P/N D5347112420200 IAW A319 SRM 51-42-11.Nov 18, 2019 · N526VA · Airbus A319112 · Fuselage Miscellaneous StructureSDR ASAA2019121983634Seat Track · corrodedAFT WET AREA SEAT TRACK AT -Y1292 HAS CORROSION AT FR66 SPLICE AREA GROUNDED - YES. NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM. REMOVED AND REPLACED SEAT TRACK P/N D534722092560 PO# 960268.1 IAW A319 SRM 51-42-11.Nov 18, 2019 · N526VA · Airbus A319112 · Fuselage, Seat/Cargo Attach FittingsSDR ASAA2019121983633Beam · corrodedAFT WET AREA LONGITUDINAL BEAM AT Y160 FR68-FR70 HAS CORROSION ON TOP SIDE GROUNDED - YES. NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM. REMOVED AND REPLACED FLOOR BEAM P/N D5347219620000 PO# 960133.1 IAW A319 SR, 51-42-11.Nov 18, 2019 · N526VA · Airbus A319112 · Fuselage Main, StructureSDR ASAA2019121983632Beam · corrodedAFT WET AREA LONGITUDINAL BEAM AT -Y160 FR68-FR70 HAS CORROSION ON TOP SIDE GROUNDED - YES. NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM. REMOVED AND REPLACED FLOOR BEAM P/N D5347209700200 IAW A319 SRM 51-42-11.Nov 18, 2019 · N526VA · Airbus A319112 · Fuselage Main, StructureSDR AALA201911199012Power Supply · inoperativeAIRCRAFT WAS GROUNDED: MAINTENANCE REPORTS AFT EPSU SHOWS EXTERIOR LIGHT FAULT. FOUND AFT EPSU BAD AND WILL NOT TEST OR POWER UP. REMOVED & REPLACED AFT EPSU AND AFT EMERGENCY BATTERY TESTED OK IAW AMM 33-51-00-720-001.Nov 18, 2019 · N769US · Airbus A319112 · Emergency LightingSDR AALA2019112089015Battery Pack · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY FLASHLIGHT UNDER AFT LEFT FLIGHT ATTENDANT JUMPSEAT NEEDED NEW BATTERY PACK. MAINTENANCE REPLACED BATTERY PACK PER AMM 25-60-00.Nov 17, 2019 · N764US · Airbus A319112 · Emergency LightingSDR AALA2019112089005Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT RIGHT HAND DOOR ASSIST BOTTLE REQUIRED SERVICING. MAINTENANCE SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE PER AMM 52-10-00.Nov 17, 2019 · N753US · Airbus A319112 · Emergency EquipmentSDR AALA201911189006Pintle Pin · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING MAIN LANDING GEAR REAR PINTLE PIN CORRODED AT FLANGE EDGE. REPLACED PINTLE PIN PER TASK CARD 26T00032001.Nov 17, 2019 · N732US · Airbus A319112 · Wing, Landing Gear Attach FittingsSDR AALA201911189026Fire Loop · shortedAIRCRAFT WAS GROUNDED: FLIGHT AIR RETURNED TO ATL ON ACCOUNT OF LEFT HAND ENGINE FIRE INDICATION. NO ENGINE SHUTDOWN OCCURRED. FLIGHT DECLARED EMERGENCY. MAINTENANCE FOUND T/R OPENING ACTUATOR CONTACTING AND GROUNDING OUT ON CORE LOOP A. REPLACED HOSE IAW AMMNov 16, 2019 · N756US · Airbus A319112 · Fire DetectionSDR AALA201911159010Door · leakingAIRCRAFT WAS GROUNDED: MAINTENANCE REPORTS FUEL LEAK RT WING DRY BAY WEEP HOLE. FOUND FUEL LEAK @ RIB #6 AND DRY BAY DOOR #1 AT UPPER STRINGER WHERE IT MEETS RIB #6. REPAIRED LEAK IAW SRM 51-76-12. LEAK CHECK GOOD.Nov 14, 2019 · N769US · Airbus A319112 · Fuel StorageSDR ASAA2019122411662Floor Panel · corrodedCABIN FLOOR PANEL 262LG HAS CORROSION ON UPPER & LOWER SURFACE GROUNDED - YES. ACCOMPLISHED TEMPORARY REPAIR TO CABIN FLOOR PANEL 262LG IAW ALASKA EA A319-25EA-00202 PASSENGER COMP FLOOR PANEL 262LG FR.60-FR68-CORROSION-TEMPORARY REPAIR.Nov 13, 2019 · N526VA · Airbus A319112 · Fuselage Floor PanelSDR AALA2019111549014Seal · leakingAIRCRAFT WAS GROUNDED: PILOT REPORTS ON DESCENT FLIGHT ATTENDANTS AND PASSENGERS HAD SMELL OF BURNING, PLASTIC. COMPLAINED OF SORE EYES AND HEADACHE. MAINTENANCE REMOVED AND REPLACED APU STARTER MOTOR SEAL IAW AMM 49-42-51. OPS AND LEAK CHECK GOOD.Nov 13, 2019 · N722US · Airbus A319112 · APU Start/Ignition SystemSDR AALA2019111439004Slide · out of positionAIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS PASSENGER CREW DOOR 831 AT FWD GALLEY AREA (WHEN DOOR IS FULL OPEN, SLIDE RAFT TOUCHES FUSELAGE). REPLACED SLIDE RAFT PASSENGER CREW DOOR 831 AT FWD GALLEY AREA IAW JOB CARD 36C83152002.Nov 12, 2019 · N710UW · Airbus A319112 · Escape SlideSDR AALA2019111209010Power Supply · no testAIRCRAFT WAS GROUNDED: HALF OF SEAT EMERGENCY LIGHTS NOT WORKING, ROW 20 THROUGH 21 INOPERABLE. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT AT LEFT SIDEWALL, EMERGENCY EXIT PER AMM 33-51-38.Nov 9, 2019 · N715UW · Airbus A319112 · Emergency LightingSDR F3LA2019111320139Unknown · odorLP1232676 ITEM 1 -- FUME EVENT : ON BASE TO FINAL EXTREAMLY STRONG ODOR ONLY ON FLIGHT DECK . /// CORRECTIVE ACTION -- PERFORMED TROUBLESHOOTING OF OIL/SMOKE SMELL IN THE CABIN NO LEAKS OR DEFECTS NOTED AT THIS TIME COULD NOT DUPLICATE DISCREPENCY ON GROUND ACNov 8, 2019 · N910FR · Airbus A319112 · Air Distribution SystemSDR AALA201911069001Computer · faultyAIRCRAFT WAS GROUNDED: PILOT REPORTS AFTER TAKEOFF CAB PR LDG ELEV FAULT ELEC BCL 1 FAULT BCL 2 FAULT FWS SDAC 1 FAULT COND ZONE REG FAULT CAB PR SYS 1 FAULT CAB PR SYS 2 FAULT RAN PROCEDURES. MAINTENANCE REPLACED SDAC #1 IAW AMM 31-55-34.Nov 5, 2019 · N769US · Airbus A319112 · Central WarningSDR AALA201911049020Floorboard · damagedAIRCRAFT WAS GROUNDED: FLOOR PANEL CENTER AISLE OF FIRST CLASS SPONGIE. ACCOMPLISHED REPAIR ON FLOOR PANEL IAW SRM 53-12-00-300-005.Nov 3, 2019 · N701UW · Airbus A319112 · Fuselage Floor PanelSDR AALA2019110439002Computer · intermittentAIRCRAFT NOT GROUNDED: AFTER TAKEOFF BOTH CAPTAINS DISPLAY UNITS AND UPPER ECAM DISPLAYWENT BLANK, CAME BACK ON A MIN LATER. HAPPENED A FEW TIMES DURING FLIGHT. REPLACED DMC1 IAW AMM 31-63-34. C/W LAND CAT III CAP TEST IAW AMM 22-97-00. SUPPLEMENTAL ACTION: SENov 2, 2019 · N732US · Airbus A319112 · Central DisplaySDR AALA201911019009Control Servo · malfunctionedAIRCRAFT IN BASE VISIT: ELEVATOR VIBRATION (BUZZ) WHEN SLIGHT PRESSURE APPLIED EITHER UPOR DOWN, FELT AT ALL ALTITUDES AND SPEEDS IN ALL CONFIGURATIONS.ALSO FELT ON GROUND IN COCKPIT. REMOVED AND REPLACE I/B ELEVEVATOR SERVO CONTROL LT IAW AMM 27-34-51-400-001Oct 31, 2019 · N768US · Airbus A319112 · Elevator Control SystemSDR AALA201911019008Battery · dischargedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT'S #1 FLASHLIGHT AT FORWARD STATION WOULD NOT TEST PROPERLY. MAINTENANCE REPLACED BATTERY IN FLASHLIGHT PER STANDARD PRACTICES AND PEFORMED SATISFACTORY OPERATIONAL CHECK.Oct 31, 2019 · N744P · Airbus A319112 · Emergency EquipmentSDR AALA201910319016Fitting · wornAIRCRAFT IN A SPECIAL VISIT: LH MLG DOOR FITTING HAS WEAR DAMAGE (PLAY) TO THE BORE AT FR42, S36LH. INSTALLED NEW FITTING IAW EA299864.Oct 31, 2019 · N717UW · Airbus A319112 · Landing Gear DoorsSDR AALA201911059014Door Frame · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON FRAME 16 RH FROM THE THIRD FASTENER HOLE.(FROM UPPER TO LOWER) OF AFT ROW AND DOOR STOP FITTING LEVEL AT FWD GALLEY AREA (1 EA) (CRACK DIRECTION IS 12 O'CLOCK L= 0.098"), ACCOMPLISHED REPAIR ON FRAME 16 RH IAW EA29Oct 29, 2019 · N768US · Airbus A319112 · Fuselage Main, StructureSDR AALA201911059012Crossbeam · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON CROSS BEAM SPLICING IN OPEN FASTENER HOLE NUMBER 3 OF FRAME 16 LH SIDE. CRACK DIRECTION IS 12 O.CLOCK (D=O.O86 INCH) IN PASSENGER CABIN (1 EA). PERFORMED REPAIR ON CROSS BEAM SPLICING IN HOLE #3 OF FRAME 16 LH SIDE Oct 28, 2019 · N768US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA201911059013Crossbeam · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON CROSS BEAM SPLICING IN OPEN FASTENER HOLE NUMBER 4 OF FRAME 16 LH SIDE. CRACK DIRECTION IS 12 O'CLOCK WITH (D =0.071INCH) IN PASSENGER CABIN (CONTACT ENGINEERING PRIOR TO FURTHERFLIGHT). PERFORMED REPAIR ON CROSS BEAOct 28, 2019 · N768US · Airbus A319112 · Fuselage Miscellaneous StructureSDR AALA2019103099008Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR ASSIST BOTTLE LOW. MAINTENANCE SERVICED DOOR ASSIST BOTTLE TO PROPER PRESSURE PER AMM 52-10-00-614-001A.Oct 28, 2019 · N712US · Airbus A319112 · Emergency EquipmentSDR AALA201910299007Control Unit · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS ELECTRICAL ODOR FROM INOP ATC/MSG LIGHT GLARE SHIELD. ELECTRICAL ODOR SOURCE FOUND TO BE THE FCU. REMOVED & REPLACED IAW AMM 22-81-12 . OPS CHECK AFS TEST & LAND CAT III CAPABILITY TEST ALL SATISFACTORY IAW AMM 22-96-00 & 2Oct 28, 2019 · N737US · Airbus A319112 · Autopilot SystemSDR AALA201911059004Pressure Plate · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON HOLE A LOCATED AT Y+1292 LH SIDE PRESSURE PLATE ATFR 35/36 IN FWD CARGO COMPARTMENT (1 EA) (CRACK DIRECTION:06 O'CLOCK APPROX. D1-D2=0.106 INCH, 2.69 MM APPROX). REPAIR COMPLETED LOCATED IN Y+1292 LH SIDE PRESSURE POct 27, 2019 · N768US · Airbus A319112 · Fuselage Main, StructureSDR AALA201911059011Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 1 BEARING ON LH HORIZONTAL STABILIZER (1 EA). REPLACED ELEVATOR HINGE ARM END FITTING #1 ON L/H HORIZONTAL STABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 4A(6) AND STEP 5.Oct 27, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201911059010Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 5 ON LH HORIZONTAL STABILIZER(1 EA). REPLACE ELEVATOR HINGE ARM END FITTING #5 ON LH HORIZONTAL STABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 4A(6) AND STEP 5.Oct 26, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201911059005Stop Fitting · crackedAIRCRAFT IN BASE VISIT: CRACK INDICATION ON FRAME 68 RH DOOR STOP 7 LOWER INB HOLE. CRACK DIRECTION 7 O'CLOCK. IN PASSENGER CABIN (1 EA). PERFORMED PERMANENT REPAIR ON FR 68RH DOOR STOP 7 LOWER INB HOLE IN PASSENGER CABIN IAW A319 SRM 53-41-12-300-010.Oct 25, 2019 · N768US · Airbus A319112 · Fuselage Main, StructureSDR AALA201911059006Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 1 ON RH HORIZONTAL STABILIZER. REPLACED ELEVATOR HINGE ARM #1 ON RH HORIZONTAL SABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 4.A(6).Oct 25, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201911059007Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 3 ON RH HORIZONTAL STABILIZER. REPLACED ELEVATOR HINGE ARM #3 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 4.A(6).Oct 25, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201911059008Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 4 ON RH HORIZONTAL STABILIZER. REPLACED ELEVATOR HINGE ARM #4 ON RH HORIZONTAL STABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 3 AND 4.B (1) TO (6).Oct 25, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201911059009Hinge Arm · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY ELEVATOR HINGE ARM 6 ON LH HORIZONTAL STABILIZER(1 EA). REPLACE ELEVATOR HINGE ARM END FITTING #6 ON LH HORIZONTAL STABILIZER IAW AMM 55-16-42-400-001-A STEP 1 THRU 3 AND 4.A(1) THRU 4A(6) AND STEP 5.Oct 25, 2019 · N768US · Airbus A319112 · Elevator StructureSDR AALA201910259008Regulator Valve · faultedAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO PHL ON ACCOUNT OF PRESSURIZATION ISSUE. EMERGENCY DESCENT MADE. CAPTAIN HAS CONTROL OF CABIN AND NO EMERGENCY LANDING DECLARED. MAINTENANCE REMOVED AND REPLACED PRESSURE REGULATING VALVE IAW AMM 36-11-52. OPS CHECK GOOOct 24, 2019 · N714US · Airbus A319112 · Cabin Pressure Control SystemSDR AALA201910259003Contactor · failedAIRCRAFT WAS GROUNDED: MAINTENANCE REPORTS EMERGENCY GENERATION WILL NOT TEST (NO FREQ, NO VOLT). REMOVED AND REPLACED AC ESSENTIAL BUS SWITCHING CONTACTOR (3XC) IAW AMM 24-25-55. OPS CHECK GOOD.Oct 24, 2019 · N760US · Airbus A319112 · Electrical Power SystemSDR AALA201910289017Hinge Fitting · wornAIRCRAFT NOT GROUNDED: VERTICAL VIBRATION DURING CLIMB THROUGH FL190 AT SPEEDS ABOVE 315 KTS, SLOWING DOWN IMPROVED IT. NOT PRESENT DURING DESCENT. OAT6C DURING CLIMB. REMOVED AND INSTALLED NEW HINGE FITTING (#5) AND HARDWARE ON #2 FITTING. SEE AALA20191028902Oct 23, 2019 · N715UW · Airbus A319112 · Elevator Control SystemSDR F3LA201911060137Hinge Fitting · wornDISCREPANCY: REFERENCE PEMCO N/R: 2650N343 LH MLG DOOR AFT KEEL BEAM HINGE FITTING FWD LUG WORN CORRECTIVE ACTION: REPAIRED L/H MLG DOOR AFT KEEL BEAM, HINGE FITTING LUG PER AIRBUS REPAIR R533 70508 ISSUE B, AREA REQ RE-INSPECTION WITH A THRESHOLD OF 8500FC Oct 23, 2019 · N949FR · Airbus A319112 · Fuselage, Door HingeSDR F3LA201911060136Fitting · crackedDISCREPANCY: REFERENCE PEMCO N/R: 2650N341 RH FR16 UPPER DOUBLE JOGGLE AREA AFT LOWER HOLE (BL SHOWS CRACK INDICATION IN THE INBD LAYER AT 9 OCLOCK POS. VIEWED FROM THE EXTERIOR CORRECTIVE ACTION: REPAIRED R/H FR16 DOUBLE JOGGLE UPPER CORNER HOLE "B" IAW AIROct 23, 2019 · N949FR · Airbus A319112 · Fuselage Main, StructureSDR F3LA201911060135Fitting · wornDISCREPANCY: REFERENCE PEMCO N/R: 2650N344 RH MLG DOOR AFT KEEL BEAM HINGE FITTING FWD LUG WORN TOTAL CYCLES 122,213 CORRECTIVE ACTION: REPAIRED R/H MLG DOOR AFT KEEL BEAM, HINGE FITTING LUG PER AIRBUS REPAIR R533 70508 ISSUE B, AREA REQ RE-INSPECTION WITHOct 23, 2019 · N949FR · Airbus A319112 · Landing Gear DoorsSDR F3LA201911060132Fitting · crackedDISCREPANCY: REFERENCE PEMCO N/R: 2650N340 RH FR16 UPPER DOUBLE JOGGLE AREA FWD LOWER HOLE (C) SHOWS CRACK INDICATION IN THE MIDDLE LAYER AT 9 OCLOCK POS. VIEWED FROM THE EXTERIOR CORRECTIVE ACTION: REPAIRED R/H FR16 UPPER DOUBLE JOGGLE FASTENER HOLE "C" PEROct 23, 2019 · N949FR · Airbus A319112 · Fuselage Main, Attach FittingsSDR AALA201910289025Servo Control · wornAIRCRAFT IN BASE VISIT: DURING ELEVATOR FREE-PLAY CHECK, FOUND R/H ELEVATOR FAILS FREEPLAY CHECK WITH YELLOW, INBOARD SERVOCONTROL ISOLATED. (7.3MM) REMOVED WORN I/B SERVO CONTROL AND INSTALLED SERVICEABLE SERVOCONTROL (34CE2) IAW A320 AMM 27-34-51-400-001A. AOct 23, 2019 · N715UW · Airbus A319112 · Elevator Control SystemSDR F3LA201911060134Structure · crackedDISCREPANCY: REFERENCE PEMCO N/R# 2650N261 R/H EMERG EXIT DOOR, FWD, INNER SEGMENT (SEGMENT #1 FWD) HAS CRACK INDICATIONS. CORRECTIVE ACTION: FAVRICATED & INSTALLED CRACK REPAIR ANGLE ON R/H EMERG. EXIT DOOR, FWD, INNER SEGMENT I.A.W. A319 FRONTIER EA# A9-52Oct 22, 2019 · N949FR · Airbus A319112 · Emergency ExitsSDR F3LA201911060133Structure · crackedDISCREPANCY: REFERENCE PEMCO N/R# 2650N260 L/H EMERG EXIT DOOR, FWD, INNER SEGMENT (SEGMENT #1 FWD) HAS CRACK INDICATIONS. CORRECTIVE ACTION: FAVRICATED & INSTALLED CRACK REPAIR ANGLE ON L/H EM ERG. EXIT DOOR, FWD, INNER SEGMENT I.A.W. A319 FRONTIER EA# A9-5Oct 22, 2019 · N949FR · Airbus A319112 · Emergency ExitsSDR AALA201910239006Hinge · wornAIRCRAFT IN BASE MAINTENANCE: RUDDER HINGE #7 HAS EXCESSIVE PLAY / WEAR AT RIB 11 ON THE VERTICAL STABILIZER. REPLACED HINGE PER AMM 55-36-41.Oct 21, 2019 · N768US · Airbus A319112 · Rudder StructureSDR AALA201910239005Hinge · wornAIRCRAFT IN BASE MAINTENANCE: RUDDER HINGE #4 HAS EXCESSIVE PLAY / WEAR AT RIB 6 ON THE VERTICAL STABILIZER. REPLACED HINGE PER AMM 55-36-41.Oct 21, 2019 · N768US · Airbus A319112 · Rudder StructureSDR AALA201910289026Hinge · wornAIRCRAFT IN BASE VISIT: EXCESSIVE PLAY RUDDER HINGE BEARING Ï¿½3 ON VERTICAL STABILIZER (1EA), EXCESSIVE PLAY L=0.010". REPLACED RUDDER HINGE #3 ON VERTICAL STABILIZER (1EA) LOCATED STA 2279, RIB5 IAW SRM 51-72-11-911-001 AND AMM 55-36-41-0401.Oct 20, 2019 · N768US · Airbus A319112 · Rudder Structure
Back to Airbus A319-112