SDR AALA202201317489Packing · leakingAIRCRAFT WAS GROUNDED: PREVIOUS CREW REPORTED STRONG ODOR BURNT OIL ON TAKE OFF AND LANDING\. UPON OUR ARRIVAL AT AIRCRAFT WE COULD SMELL THE ODOR EVEN WITH OUR MASKS ON AND THE CABIN DOOR OPEN. MAINTENANCE HAS ISOLATED THE SOURCE OF THE ODOR TO THE APU. MAISDR AALA202201247489Apu · odorAIRCRAFT WAS GROUNDED: PREVIOUS CREW REPORTED STRONG ODOR BURNT OIL ON TAKE OFF AND LANDING\. UPON OUR ARRIVAL AT AIRCRAFT WE COULD SMELL THE ODOR EVEN WITH OUR MASKS ON AND THE CABIN DOOR OPEN. MAINTENANCE HAS ISOLATED THE SOURCE OF THE ODOR TO THE APU. OPENSDR AALA202201195784Door Latch · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT RIGHT HAND LAVATORY DOOR DIFFICULT TO OPEN/CLOSE. ADJUSTED DOOR LATCH AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202201209434Window · noneAIRCRAFT WAS GROUNDED: LEFT FORWARD FACING WINDOW IS PITTED. VISIBILITY IS EXTREMELY REDUCED FACING INTO THE SUN. REPLACED WINDOW PER TASK CARD 262105600.SDR AALA202201186114Door · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT LEFT SIDE LAVATORY DOOR STUCK CLOSED. ADJUSTED DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-45-19.SDR AALA202201195227Proximity Switch · noneAIRCRAFT WAS GROUNDED: AT DEPARTURE LEFT AFT DOOR WAS ARMED BUT DID NOT SHOW ARMED ON ECAM DOOR PAGE REPLACED LEFT AFT ESCAPE SLIDE PROXIMITY SWITCH HANDLE 7WN1 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-73-11.SDR AALA202201146293Window · delaminatedAIRCRAFT WAS GROUNDED: FIRST OFFICERS AFT SIDE WINDOW DELAMINATED AND WITH SEVERAL VERTICAL CRAZING MARKS/DEFECTS. REPLACED WINDOW PER AMM 56-11-12.SDR AALA202201131245Battery · fault messageAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK EMERGENCY LIGHT TEST BATTERY/EMERGENCY POWER SUPPLY UNIT (12WL) RIGHT FAULT CAME UP. REPLACED 12WL BATTERY PER AMM 33-51-38.SDR AALA202201130030Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK EMERGENCY LIGHTS TEST "BATTERY/EMERGENCY POWER SUPPLY UNIT (13WL) AFT LEFT CLASS 1" FAULT CAME UP. REPLACED BATTERY AT AFT LEFT PER AMM 33-51-38.SDR AALA202201135792Battery · fault messageAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK EMERGENCY LIGHTS TEST "BATTERY EMERGENCY POWER SUPPLY UNIT (10WL) FORWARD LEFT CLASS 1" FAULT CAME UP. REPLACED BATTERY (10WL) PER AMM 33-51-38.SDR AALA202201108942Relay · fault messageAIRCRAFT WAS GROUNDED: CENTER TANK 1 PUMP FAULT LIGHT ON FUEL PANEL .ECAM MESSAGE READS FUEL CENTER TANK PUMP 1 LOW PRESSURE. REPLACED RELAY 69QA AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER TSM 28-21-00-810-817A.SDR AALA202201102822Relay · fault messageAIRCRAFT WAS NOT GROUNDED: CENTER TANK PUMP 01 LOW PRESSURE MESSAGE / CENTER TANK PUMP FAULT LIGHT ILLUMINATED / AMBER LOW INDICATION ( FUEL PAGE). **SUPPLEMENTAL REPORT FOR AALA202201042822: REPLACED RELAY 69QA AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHESDR AALA202201045523Sliding Window · unlockedAIRCRAFT WAS GROUNDED: REJECTED TAKE OFF AT 90 KNOTS DUE TO LOUD SQUEAL FROM FLIGHT DECK WIDOW. SLIDING WIDOW WAS NOT SECURED. RETURNED TO GATE FOR EMERGENCY APPLICATION OF BRAKES INSPECTION. SATISFACTORY BRAKE INSPECTION ACCOMPLISHED PER AMM 05-51-16-200-001-SDR AALA202201042822None · noneAIRCRAFT WAS NOT GROUNDED: CENTER TANK PUMP 01 LOW PRESSURE MESSAGE / CENTER TANK PUMP FAULT LIGHT ILLUMINATED / AMBER LOW INDICATION ( FUEL PAGE). **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN)SDR AALA202201046694Hinge · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY DOOR INOPERATIVE. **SUPPLEMENTAL REPORT FOR AALA202201036694: ADJUSTED DOOR HINGE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-40-00** (CLOSED)SDR AALA202201036694None · noneAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY DOOR INOPERATIVE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202112303019Stop · tornAIRCRAFT WAS GROUNDED: L1 DOOR HANDLE RUBBER STOP TORN. **SUPPLEMENTAL REPORT FOR AALA202112293019: REPLACED DOOR HANDLE STOP PER EA 332964A ** (CLOSED)SDR AALA202112307223O-Ring · leakingAIRCRAFT WAS GROUNDED: CAPTAIN AND FIRST OFFICER EXPERIENCED FUME EVENT AROUND 4000 FEET. SWEET CHEMICAL SMELL AFTER INITIAL DIRTY SOCKS SMELL. MAINTENANCE FOUND OIL LEAKING FROM THE APU GENERATOR AND THE APU DRAIN PLUG O-RINGS AND REPLACED THE O-RINGS PER ASDR AALA202112293019Stop · tornAIRCRAFT WAS GROUNDED: L1 DOOR HANDLE RUBBER STOP TORN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED ** (OPEN)SDR AALA202112297223Unknown · odorAIRCRAFT WAS GROUNDED: CAPTAIN AND FIRST OFFICER EXPERIENCED FUME EVENT AROUND 4000 FEET. SWEET CHEMICAL SMELL AFTER INITIAL DIRTY SOCKS SMELL. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202112275534Lock · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY E DOOR INOPERATIVE. REPLACED DOOR HOLD OPEN LOCK AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER CMM 25-47-03.SDR AALA202112278351Wire · brokenAIRCRAFT WAS GROUNDED: EMERGENCY LIGHT AT SEAT 23C AND 22C INOPERATIVE. FOUND BROKEN WIRES AT CONNECTOR REPAIR WIRES PER STANDARD ELECTRICAL PRACTICES 20-53-50.SDR AALA202112276375Damper · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT LEFT ENTRY DOOR DAMPER PRESSURE LOW. SERVICED AFT LEFT ENTRY DOOR DAMPER PER AMM 52-10-00.SDR ANCF20211223002None · nonePILOT REPORT - WO16'582'204
20.DEC.2021 => (URGENT PRIORITY) AFT CARGO DOOR INDICATION OPEN/CLOSED INTERMITTENT. AFT CARGO DOOR INDICATION OPEN/CLOSED INTERMITTENT
CORRECTIVE ACTION
20.DEC.2021=> THIS REPORT IS DEFERRED IAW MEL 52-70-01-3 LEVEL "C" 723-TSSDR AALA202112270765Light · inoperativeAIRCRAFT WAS GROUNDED: AFT LEFT SLIDE LIGHT DOES NOT COME ON WHEN DOOR IS ARMED. **SUPPLEMENTAL REPORT FOR AALA202112210765: PERFORMED OPERATIONS CHECK TEST OF L2 DOOR WARNING SYSTEM PER AMM 52-73-00-710-002-E. OPERATIONS CHECKS OK.** (CLOSED)SDR AALA202112210765None · noneAIRCRAFT WAS GROUNDED: AFT LEFT SLIDE LIGHT DOES NOT COME ON WHEN DOOR IS ARMED. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)SDR AALA202112203277Screw · missingAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR VERY HARD TO OPEN IN FLIGHT. REPLACED MISSING SCREWS ON UPPER DOOR JAMB PER AMM 52-10-00.SDR AALA202112208672Indicator · inaccurateAIRCRAFT WAS NOT GROUNDED: AIRCRAFT DIVERTED TO SLC ACCOUNT OF JAC RUNWAY CONDITIONS. WHILE DIVERTING TO SLC, FLIGHT DECK REPORTED LEFT FUEL TANK READING INACCURATE. FLIGHT DECLARED AN EMERGENCY DUE TO MINIMUM FUEL. MAINTENANCE ACCOMPLISHED FUEL SUMPING PER AMSDR AALA202112157701Lens · missingAIRCRAFT WAS NOT GROUNDED: MID LEFT EMERGENCY DOOR ARMED LIGHT LENS MISSING. INSTALLED EMERGENCY DOOR ARMED LIGHT LENS PER AMM 52-73-00.SDR AALA202112062169Smoke Detector · false activationAIRCRAFT WAS NOT GROUNDED: MOMENTARY ILLUMINATION OF THE MASTER WARNING LIGHT IN FLIGHT WITH AFT LAVATORY SMOKE. NO SMOKE FOUND. ACCOMPLISHED OPERATIONS TEST OF LAVATORY SMOKE DETECTION SYSTEM PER AMM 26-17-00. BOTH AFT LAVATORIES CHECK GOOD AND NO EVIDENCE OFSDR AALA202111306641Cooling Fan · leakingAIRCRAFT WAS GROUNDED: ON FINAL APPROACH INTO MIA DESCENDING THROUGH 11000 FT -1 PITCH CLEAR AIR HEAVY SMELLY SOCK ACRID ODOR. **SUPPLEMENTAL REPORT FOR AALA202111226641: MAINTENANCE FOUND THE APU OIL COOLING FAN O-RING LEAKING AND REPLACED IT PER AMM 49-52-51SDR AALA202111241333Flashlight · faultyAIRCRAFT WAS NOT GROUNDED: AFT FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT FOUND ON. **SUPPLEMENTAL REPORT FOR AALA202111231333: REPLACED FLASHLIGHT.** (CLOSED)SDR AALA202111248841Bracket · brokenAIRCRAFT WAS NOT GROUNDED: AFT FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT BRACKET BROKEN. **SUPPLEMENTAL REPORT FOR AALA202111238841: REPLACED MOUNTING BRACKET.** (CLOSED)SDR AALA202111238841None · noneAIRCRAFT WAS NOT GROUNDED: AFT FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT BRACKET BROKEN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202111231333None · noneAIRCRAFT WAS NOT GROUNDED: AFT FLIGHT ATTENDANT JUMPSEAT FLASHLIGHT FOUND ON. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202111226641Unknown · odorAIRCRAFT WAS GROUNDED: ON FINAL APPROACH INTO MIA DESCENDING THROUGH 11000 FT -1 PITCH CLEAR AIR HEAVY SMELLY SOCK ACRID ODOR. (OPEN)SDR AALA202111309890Cooling Fan · leakingAIRCRAFT WAS GROUNDED: ON FINAL APPROACH AIRCRAFT ENCOUNTER HEAVY RAIN AND CREW NOTED CABIN SMELLY SOCK, ACRID ODOR WITH HAZE IN CABIN. MAINTENANCE: ISOLATED SOURCE OF THE ODOR AS THE APU. MAINTENANCE FOUND THE APU OIL COOLING FAN O-RING LEAKING AND REPLACED SDR AALA202111229890Apu · odorAIRCRAFT WAS GROUNDED: ON FINAL APPROACH AIRCRAFT ENCOUNTER HEAVY RAIN AND CREW NOTED CABIN SMELLY SOCK, ACRID ODOR WITH HAZE IN CABIN. MAINTENANCE: ISOLATED SOURCE OF THE ODOR AS THE APU. (OPEN)SDR AALA202111191974Handle · looseAIRCRAFT WAS NOT GROUNDED: FORWARD L1 LAVATORY INNER DOOR HANDLE COMES LOOSE WITH LITTLE EFFORT ON HANDLE. ADJUSTED LAVATORY DOOR HANDLE SCREW AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-40-00.SDR AALA202111233106Light · out of adjustAIRCRAFT WAS NOT GROUNDED: 9C EMERGENCY LIGHT IS WRONG COLOR. **SUPPLEMENTAL REPORT FOR AALA202111193106: REMOVED AND REPLACED 9C EMERGENCY LIGHT COVER PER AMM 33-50-00.** (CLOSED)SDR AALA202111193106None · noneAIRCRAFT WAS NOT GROUNDED: 9C EMERGENCY LIGHT IS WRONG COLOR. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)SDR AALA202111164683Power Supply · failedAIRCRAFT WAS NOT GROUNDED: FOLLOWING REPLACEMENT OF EMERGENCY POWER SUPPLY UNIT BATTERIES PER JOB CARD 26C00033004 EMERGENCY POWER SUPPLY UNIT 13WL (AFT GALLEY CEILING) FAILS OPERATIONS TEST FOR EXTERIOR LIGHTING. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNSDR AALA202111153926Light · incorrectAIRCRAFT WAS NOT GROUNDED: FOUND SEAT 24ABC HAS WRONG COLOR EMERGENCY EXIT LIGHT. REPLACED EXIT LIGHT WITH THE CORRECT ONE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-13.SDR AALA202111151790Door · lack of lubeAIRCRAFT WAS NOT GROUNDED: 1L DOOR HARD TO OPEN. LUBRICATED DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-11-00.SDR AALA202111153616Switch · defectiveAIRCRAFT WAS GROUNDED: LEVEL CRUISE FL 390 ALL SYSTEMS NORMAL .OXYGEN PASSENGER AMBER MESSAGE ON ECAM,OXYGEN PASSENGER SYSTEM ON LIGHT ON OVERHEAD ON.PASSENGER O2 MASKS DEPLOYED IN CABIN. CABIN PRESSURE NORMAL.DOOR INDICATIONS ALL NORMAL. FL 390" CABIN WAS AT SDR AALA2021111123616None · noneAIRCRAFT WAS GROUNDED: LEVEL CRUISE FL 390 ALL SYSTEMS NORMAL .OXYGEN PASSENGER AMBER MESSAGE ON ECAM,OXYGEN PASSENGER SYSTEM ON LIGHT ON OVERHEAD ON.PASSENGER O2 MASKS DEPLOYED IN CABIN. CABIN PRESSURE NORMAL.DOOR INDICATIONS ALL NORMAL. FL 390" CABIN WAS AT SDR AALA202111111116Wire · out of positionAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT SEAT 27C HAS WIRE PULLED OUT OF CONNECTOR. PER ESPM 20-44-29, REPAIRED WIRE CONNECTION FOR SEAT 27C EMERGENCY LIGHT.SDR AALA202111085454Door · out of adjustAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR STICKING AT TOP. DIFFICULT TO OPEN. ADJUSTED FLIGHT DECK DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-51-11.SDR AALA202111013212Oven · odorAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY OVEN NUMBER 2 HAS A STRONG ELECTRICAL BURNING SMELL WHEN OPERATING. CIRCUIT BREAKER DID NOT POP. REMOVED AND REPLACED FORWARD GALLEY NUMBER 2 OVEN PER AMM 25-35-19-0401.SDR AALA202110267383Door · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT RIGHT LAVATORY DOOR DIFFICULT TO OPEN. ADJUSTED DOOR PER AMM 25-40-00.