Airbus A319-131
Service difficulty reports · 5,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025032103049Slide · expiredFORWARD DOOR ESCAPE SLIDE PACK ASSEMBLY INSTALL {A3NB-25-3-0020} - REPLACEMENT OF SLIDE PERFORMED ON TASK 31-2562-1-3803.SDR CALA2025032103048Slide · expiredAFT DOOR ESCAPE SLIDE PACK ASSEMBLY INSTALL {A3NB-25-3-0021} . REPLACEMENT ACCOMPLISHED TASK CARD 31-2562-1-3804.SDR CALA2025032003018Slide · not reportedFORWARD DOOR ESCAPE SLIDE PACK ASSEMBLY INSTALL {A3NB-25-3-0020} - RETURN DOOR 1R TO NORMAL AFTER SLIDE REPLACEMENT REF AMM 52-10-00-860-002-A. REACTIVATEDD DOOR 1R. REF AMM 52-10-00-860-002-A. DOOR R 1 ACTIVATED FOR ABOVE AMM , REF GMM 09-25-05.SDR CALA2025031902960Cover · looseDOOR 2R LIFE RAFT PANCOVER LOCKING LATCHLOOSE ATTEMPTED TO FIT MULTIPLE DIFFERENT SLIDE COVERS ON DOOR 2R, NO FIX. LATCHES DO NOT LINE UP PROPERLY. WORK DONE IN REF WITH AMM 25-62-44. SUSPECT FRAME OF SLIDE WARPED/BENT, SEE ATTAHCED PICTURES FOR CLARIFICATION.SDR CALA2025031902963Proximity Switch · malfunctionedGATE RETURNFWD CARGO DOOR FWD CAGO DOOR CONFIRM LOCKED AND CLOSE REF MEL5270 CE 5270CE APPROVED DDP ACOMPLIS DOOR CLOSED AND LOCK *DM* AVIATAR SHOWS "DOOR FWD CARGO" HITTING CONSISTANTLY EACH FLIGHT. REF TSM 52-31-00-810-801-A. ADDING PROX SWITCHES 28WV AND 30SDR CALA2025031802915None · noneINSTALLED RH SLIDE SAFETY LOCKPIN IAW AMM TASK 25-62-00 REMOVED RH OFF-WING SLIDE SAFETY LOCK PIN IAW AMM TASK 25-62-00. C/W RII FOR THE REACTIVATION OF THE RT OVERWING SLIDE PER THE GMMSDR CALA2025031802911Switch · faultedAFT CARGO DOOR OPEN /CLOSE SWITCH INOP, ONLY WORKS WHEN FWD CARGO DOOR OPERATED. PLACING AFT CARGO DOOR OPEN/CLOSE SWITCH ON MEL 5230AB. OK TO APPLY MEL 5230AB FOR AFT CARGO DOOR ELECTRICAL CONTROL INOP PLACED AFT CARGO DOOR OPEN/CLOSE SWITCH ON MEL 5230AB. COSDR CALA2025031402841Slide · overpressuredCABIN DOOR 1L SLIDEPRESSURE INDICATOR ISIN THE RED INSPECTED DOOR SLIDE PRESSURE AT DOOR 1L REF AMM 25-62-00, DOOR SLIDE PRESSURE WITHIN GREEN BAND CLOSER TO OVER PRESSURE PORTION. DOOR SLIDE PRESSURE WITHIN LIMITS. A/C OK FOR SERVICE.SDR CALA2025031402819Tape · peelingLOUD WHISTLE FM RH OVERWING EXIT EVEN AT 8 PSID FOUND PEELING SPEED TAPE FROM DIP TEMP REPAIR IN LP 4125574. REPLACED SPEED TAPE IAW SRM 57-41-11. OK TO CONTINUESDR CALA2025031702874Computer · faultyELAC 1 PITCH FAULT ON TAKEOFF ROLL. ACP LOW SPEED ABORT R&R'D ELAC 1, OPS NML, REF AMM 27-93-34/401.SDR CALA2025031702870Tape · looseLOUD WHISTLING NOISE COMING FROM RH OVERWING EXI TS. NOISE STARTED JUST A FTER TAKEOFF FOUND TAPE LOOSE AREA ALREADY ON DIP LOG. 9620908 RE-SECURED WITH MISSING TAPE.SDR CALA2025031302800Reservoir · lowHYD Y RES OVHT YELLOW SYSTEM RESOVOIR QUANTITY WAS BELOW THE REQUIRED SERVICE LEVEL. SERVICED YELLOW SYSTEM PER AMM 12-12-29. REMOVED AND REPLACED THE YELLOW CHECK VALVE Y(3083) PER AMM29-24-21-000-001. ACCOMPLISHED TEST 3 IDLE LEAK CHECK PER 71-00-00-710-012SDR CALA2025031302790Battery · faultedOPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - BATTERY TEST SHOWING FAULT EPSU BATTERY EMERGENCY FWD LEFT. REMOVED AND REPLACED FWD LEFT EMERGENCY BATTERY PER AMM 33-51-38-000-002-A. OPS CHECK GOOD.SDR CALA2025031102710Display · faultedMCDU 2 BLANK SCREEN REQUESTING DEFERRAL. APPROVED. PLACARD #2 MCDU. PARTS BFS IAH. OK TO CONTINUE. REMOVED AND REPLACED RIGHT SIDE MCDU OPS CHECK GOOD REF AMM 22-82-12SDR CALA2025031002668Battery · faultedFORWARD DOOR ESCAPE SLIDE PACK ASSEMBLY INSTALL {A3NB-25-3-0020} - EMERGENCY SYSTEM LIGHTS BITE CHECK FAILS (NO SYS OK LIGHT) WITH STATUS MESSAGE (EPSU INT LOAD FWD L) REMOVED AND REPLACED BATTERY OF EPSU IAW AMM 33-51-38. OPS CHECK GOOD.SDR CALA2025031102726Battery · faultedAFT DOOR ESCAPE SLIDE PACK ASSEMBLY INSTALL {A3NB-25-3-0021} - AFTER EMERGENCY LIGHT TEST FOR ESCAPE SLIDE INSTALLATION TEST WAS FOUND A CIDS FAULT EPSU BATTERY AFT L. REQUIRES RII. T/S PER TSM 33-51-00-810-802-A, UP TO AND INCLUDING STEP A (A) 1. NO DISCREPANSDR CALA2025030702619Battery · no testACP. CABIN EMERGENCY LIGHT CHECK GOT MESSAGE EMER SYSTEM EPSU BATTERY AFT L ATA 33-51-38. R/R EPSU 13WL BATTERY REF AMM 33-51-38, OPS CHECKS OK.SDR CALA2025030702628Indication Sys · faultedRIGHT OVERWING EXIT "SLIDE" DOES NOT INDICATE ARMED. INSTALL THE LOCK PIN ASSY ON THE INFLATION RESERVOIR IN THE AFT CARGO COMPARTMENT AS PER AMM 52-21-11-000-001-A STEP 3 A. ECAM PAGE INDICATION SHOWS RT HAND OVERWING DOOR CLOSED AND LATCHED BUT DOES NOT SHOWSDR CALA2025030502601Power Supply · failedOPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - TEST HAS FAULTS EPSU EMER R, EPSU BATT EMER L, EPSU BATT AFT L, AND EPSU UNIT FWD L. NEEDS PWR. SUPPLY AND 4 FRESH BATTERIES. FWD. L / H POWER SUPPLY. P / N ON 3214-54-10. , M & E 31-3350-9-9001 SDR CALA2025030302540Power Supply · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - EPSU FWD LH MESSAGE FAILURE DISPLAYED ON TEST. REMOVED AND REPLACED FWD EMERGENCY POWER SUPPLY UNIT AS PER AMM 33-51-38/401. OPERATIONAL TEST GOOD.PARTS USED: 31-3350-9-9001, QTY :1SDR CALA2025030302548Packing · damagedHYD Y RSVR LO LVL ECAM AT FL370 FOUND YELLOW SYSTEM QUANTITY ABOVE AMBER BOX. SERVICED QUANTITY INTO SERVICEABLE BAND AND RAN HYDRAULICS. FOUND LEAK AT PTU 3039 GM CONNECTION. REF AMM 12-12-29, AMM 29-00-99. REMOVED CHECK VALVE 3039GM, REPLACED FAILED PACKINGSDR CALA2025031900489Control Servo · damagedFOUND RH INBOARD AILERON SERVO CONTROL ROD UNABLE TO FULLY RETRACT. INSPECTED ATTACH POINTS, HARDWARE AND VERIFIED NEW SERVO CONTROL SN# 5430 EFFECTIVE FOR AC AND POSITION 33CE2 "RH INBOARD" PER RII 09-25-05 REMOVED RIGHT INBOARD AILERON SERVO CONTROL ACTUATORSDR CALA2025030302532Fairing · damagedPDA 2REF LP 4012401. #1ENG RH TR FAIRING PEICE BROKEN OFF. 6IN BY 1/2IN IN SIZE. WEIGHT ESTIMATED ABOVE 3.5OZ BUT BELOW 2.2LBS SDR ACCOMPLISHED REF LP 4012401 FOR REPAIR TO #1 ENG INBOARD REVERSER FAIRING REPAIR.SDR CALA2025022802516Battery · no testEPSU BATTERY EMERGENCY L FAILED EMERGENCY TEST REMOVED AND REPLACED EPSU BATTERY L, REF AMM 33-51-38-000-002-A. OPS CHECK NORMAL OK TO CONTINUE.SDR CALA2025030402567Lgciu · faultedDURING DECENT AT ABOUTFL210 GOT DOOR AFTCARGO ECAM WITHNORMAL PR ESSURIZATION UPDATED MAA CODE FIX USING VENDOR MAA SCREEN DEFER REF MEL 5270CD. CONFIRMED AFT CARGO DOOR CLOSED AND LATCHED-MEL 5270CD APPLIED FOR DOOR INDIC INOP. CONFIRMED AFT CARGO DOOR CLOSDR CALA2025022602484Cap · missingPDA 2 REFUEL CAP FOUND MISSING ON ARRIVAL INTO CHS SEE LOG PAGE 3977389 FUEL CAP WAS ALREADY ON CDL 3883611 ALLIED REPORTS - DIFFICULT TO PUT THE FUEL CAP ON FUEL CAP DAMAGED, REQUEST CDL. APPLIED CDL DDP. CDL 28A. DISPATCH DESK: 32 NAME: NW DATE: 15-FEB-25- 2SDR CALA2025022602474Filter · odorAIR CONDITIONING DIRTY SOCK SMELL BELOW 13000 ON DEPARTURE AND A RRIVAL NEED TO DF PACK 1 APPROVED FOR MEL 3152W CREW DID SAY THE SMELL WAS FROM PACK 1 COMPLYED WITH MEL 2152W . DUE TO PREVIOUS HISTORY NEED POSITIVE FIX, NOT JUST AN OPS CHECK *DM* UPDATED M/L SDR CALA2025022402418Slide · no testDURING EMERGENCY LIGHT TEST RECEIVED "EPSU EXT LOAD FWD L" MESSAGE. SEE PIC. PERFORMED EPSU BITE TEST ON FWD LEFT REF AMM 33-51-00-710-001. EPSU SHOWS EXTERIOR LIGHTS FAULT. NEEDS TO T/S REF TSM 33-51-00-810-808-A STEP 4.B.(2). REQUEST MEL 3350P FOR ESCAPE SLISDR CALA2025022602471Oven · fireOVEN 105 R11 IN FWD GALLEY HAD SMALL FLAME AND POSSIBLE DAMAGE TO INSIDE. REMOVED THE OVEN AT POSITION R11. INSPECTED THE OVEN EXTERNALLY AND ALSO THE COMPARTMENT FOR THE OVEN. VERIFY NO EVIDENCE OF HEAT DAMAGE IS PRESENT. THE FLAME WAS A PIECE OF FOOD INSISDR CALA2025022502466None · noneINSTALLED EMERGENCY RELEASE MECHANISM LOCKOUT PIN ON RH OVER WING EXIT HATCH REF AMM 52-21-11-000-001-A REMOVED EMERGENCY RELEASE MECHANISM LOCKOUT PIN ON RH OVERWING EXIT HATCH MX COMPLETE REF MM 52-21-11 VERIFIED REMOVAL OF EMERGENCY RELEASE MECHANISM LOCKOUSDR CALA2025022002407Battery · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - RAN BATTERY TEST, NEED REPLACEMENT FOR ALL 4 LOCATIONS REPLACED WITH NEW EPSU BATTERY PER AMM 51-38-400-001-A. OPS CHECK OK.SDR CALA2025021902378Proximity Sensor · out of toleranceFORWARD CARGO DOOR PROXIMITY SWITCH INSPECTION {A3NB-52-3-0008} - FWD CARGO DOOR J2 SENSOR CLEARANCE OUT OF TOLERANCE. ADJUSTED J2 SENSOR CLEARANCE. REF AMM 52-35-13-400-002-A. CLEARANCE WITHIN TOLERANCE.SDR CALA2025021902372Battery · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - BATTERY TEST UNSATISFIED. EPSU LOCATED AT FWD L AND AFT L NEED REPLACEMENT UPDATED PART INFO. BATTERY NIS IN SEA NEEDS A NEW BATTERY PACK FORWARD L / H SIDE. P / N : AD3214-31. S /SDR CALA2025021302311Filter · faultedHOT AIR FAULT TURNED OFF HOT AIR PER ECAM POST FLIGHT REPORT FAULTED TRIM AIR PRESS VALVE FAILURE, PER TSM TASK 21-63-00-810-805-A STEP 4A (1) REPLACED TRIM AIR PRESSURE-REGULATING VALVE FILTER (REF. AMM 21-63-00-920-001). PERFORMED OPS CHECK TEST OF CAB TEMP SDR CALA2025021302310Door Seal · damagedETREMELY LOUD NOISE COMMING FROM DOOR 1L INFLIGHT AIR RETURN DEBRIEFED CREW WAS LOUD AT ALL ALTITUDES AND AT ANY DIIFERENTIAL PRESS. NOISE LOUDEST AT LOWER AFT CORNER OF L-1 DOOR. RAGS AND BLANKETS NO HELP. DOOR SEAL HAS A HOLE IN THE LOWER AFT CORNER. RESDR CALA2025021302318Girt Bar · dirtyDOOR L2 DIFFICULT TO DIS ARM. CLEANED DEBRIS FROM AROUND GIRT BAR AND GIRT BAR FITTINGS. ACCOMPLISHED DOOR 2L ARM/DISARM OPERATION WITH NO DEFECTS NOTED. REF AMM 25-62-44. OK F/SVC. ADD EMP:U010764,U342413SDR CALA2025021402330Fan · failedVERY STRONG BURNING SMEL L AFTER LANDING SIMILAR TO PAPER OR PLA STIC. NO VISIBLE SMOKE OR ECAMS. ODOR WAS ONLY IN THE COCKPIT EVERYTHING OPERATED NORMALLY. CAME 1 MINUTE AFTER LANDING AVNCS VENT BLOWER FAN BREAKER POPED (AD10) APPLIED MEL 2126AC. DDP COMPLIEDSDR CALA2025021002266Battery · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - LEFT EPSU BATTERY FAILED TEST. REPLACED EPSU BATTERY WITH SERVICEABLE ONE FROM STOCK. OPS CHECK GOOD PARTS USED: 18-3351-3-0001,QTY :1SDR CALA2025021002254Accumulator · faultedHYD G RSVR LO LVL INFLIGHT DEBRIEFED WITH THE PILOTS. THERE WAS A HYD G RSVR LO LVL ECAM MSG. THEY STATED THE RESERVOIR WAS LOW AND THINKING THERE IS A POSSIBLE LEAK ON THE GREEN SYSTEM. THE PILOTS FOLLOWED THEIR PROCEDURES AND HAD THE LANDING GEAR DOORS MANUASDR CALA2025020702232Battery · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - BATTERY CAPACITY TEST SHOWING FAULT ON CIDS DISPLAY PANNEL. "EPSU COM AFT L". REMOVED AND REPLACED EPSU AFT L BATTERY PACK IAW AMM 33-51-38-400-002-A. OPS CHECK GOOD.SDR CALA2025020602223Power Supply · dischargedOPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - EPSU UNIT AFT L 33-51-38 RPLCD EPSU AND NEW BATT, NO HELP. SLAVED IN NEW EPSU AND NEW BATT, NO HELP, RESULTS IN NO COMM AT CIDS PANEL TEST. PLEASE VERIFY PROPER EPSU PART NUMBER IS CURRENTLY INSTLDSDR CALA2025020602219Warning Message · false activationL/G SYS DISAGREE AFTERLANDING. GEAR SHOWSDOWN AND LOCKED. LGCIU 1 AND 2 BITE TEST. TEST PASSED , PERFORMED GROUND SCAN, NO FAULTS , CHECKED PROX SENSORS, NO DEFECTS NOTED, FOUND NO HISTORY, REF. AMM 32-69-00SDR CALA2025020502215Vsv · failedENG2 FAIL ON T/O ROLL. NO INDICATION NOTICED PRIOR TO FAILURE ENG 2 STALL WITH CFDS VSV MECH/BLD VLV/LPC2 REFERENCE TSM 71-00-00-810-809-A, ALSO SUGGEST MCD INSPECTION PER AMM 79-22-45-000-010-A TO DETERMINE ENGINE SERVICEABILITY. TOMC-MEREDITH FLAGGING SDRSDR CALA2025020502214Slide · no testDOOR 2 LEFT SLIDE DID NOT DEPLOY PROPERLY. REMOVED L2 SLIDE IAW AMM 25-62-44/401. INFO ONLY... PER FIRE DEPT, L2 SLIDE DID INFLATE AND 3 PASSENGERS WENT DOWN UNTIL IT DEFLATED AND FLIGHT ATTENDANT KEPT PEOPLE FROM USING IT.SDR CALA2025020502213Door · brokenREPLACED LH MLG DOOR. LP CLOSED.LOWER SECTION OF CENTRAL RAMP BROKEN AND DETACHED FROM L MLG DOOR. PUNCTURED ALL THE WAY THROUGH AND IS STICKING OUT 6 INCHES SEE IPC REF 52-81-14-10A ITEM 90 AND PICTURES ATTACHED SEE MORE PICS ATTACHED REMOVED LH MLG DOOR IAW SDR CALA2025020302186Computer · faultyDURING CRUISE, AN ELECTRICAL ODOR WAS NOTED BY THE CABIN CREW AR OUND ROWS 10-12, A SLIGHT HAZE WAS OBSERVED IN THE SAME AREA. NO SMOKE WAS NOTED EMANATING FROM ANYTHING IN THE VICINITY OF THE HAZE. NO ODOR OR HAZE WAS NOTED IN THE FLIGHT DECK. CHECKLIST 2. 80SDR CALA2025020302171Battery · no testOPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - FOUND FAULT EPSU BATTERY AFT LEFT REPLACED EPSU 13WL BATTERY PER AMM TASK 33-51-38-000/400-002-A. EMERGENCY LIGHTING TEST OK. NO FAULTS FOUND.PARTS USED: 18-3351-3-0001, QTY :1SDR CALA2025020402202Fuel Cap · missingPDA 2 FUEL CAP MISSING. SEARCH AREA NO FUEL CAP FOUND ,REF LOG PG 3725830 FUEL CAP MISSING SEARCHED RAMP AREA, FUEL CART, AND WORK STAND, TALKED TO FUELER AND HE SAID AIRCRAFT ARRIVED WITHOUT CAP,SDR CALA2025013002128Battery Pack · no testCABIN EMERGENCY LIGHTING BATTERY CAPACITY OPERATIONAL CHECK {A3NB-33-3-6013} - FWD R EMERGENCY LIGHT BATTERY FAILED CAPACITY TEST REMOVED AND REPLACED FWD R EMERGENCY LIGHT BATTERY AS PER AMM 33-51-38. OPS CHECK, GOOD.SDR CALA2025012902106Door · out of adjustCATERING REPORT DOOR 2L NOT FULLY OPENING LUBRICATED DOOR DAMPER CYLINDER JOINTS AND PERFORMED DAMPER CYLINDER REF AMM 52-10-00-710-001-A. DOOR OPENS AND LOCKS, BUT REQUIRES SIGNIFICANT FORCE TO GET INTO THE OPEN AND LOCKED PISTION. DOOR OPERATES SMOOTHLY AF
Back to Airbus A319-131