Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016081706047Frame · crackedCRACK FOUND AROUND A FASTENER HOLE COMMON TO BULKHEAD AT FRAME 35 AND STR 30 LT SIDE. REPAIR ON FRAME 35 AND STR 30+1.400 OF LT SIDE IN FWD CARGO COMPARTMENT IAW PRI 543323-14, REV 0.2 AND ER/A 543323-14AD, REV ORIGINAL.SDR DALA2016030201618Structure · crackedCRACK AFT LOWER CORNER ON PASSENGER CREW DOOR L2 AT 7.5' OF LOWER EDGE AT AFT GALLEY AREA. REPLACED AFT LOWER CORNER ON PASSENGER CREW DOOR L2 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D52111490.SDR DALA2016022501571Stringer · corrodedCORROSION ON STRINGER 37L IN FWD CARGO COMPARTMENT BETWEEN FRAME 29 TO FRAME 30 PERFORMED PERMANENT REPAIR ON STR 37L IN FWD CARGO COMPARTMENT BETWEEN FRAME 29 TO FRAME 30 IAW SRM 53-21-13, PARA D, FIG 204, SHEETS 2 AND SHEET 3.SDR DALA2016022401811Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 AT FWD GALLEY AREA. REPLACED THE RAIL DUMMY IAW SRM 51-72-11 AND DWG D53112827.SDR DALA2016030201580Shear Tie · corrodedCORROSION ON CLEAT FRAME 30, RT IN FWD CARGO COMPARTMENT BETWEEN STR 40 TO STR 41. REPLACED CLEAT FRAME 30 RT IN FWD CC BETWEEN STR 40 TO STR 41 IAW SRM 51-72-11AND DWG D53230320.SDR DALA2016030201579Shear Tie · corrodedCORROSION ON CLEAT, FRAME 31 RT IN FWD CARGO COMPARTMENT BETWEEN STR 40 TO STR 41 REPLACED CLEAT FRAME 31 RT IN FWD CARGO COMPARTMENT BETWEEN STR 40 TO STR 41 IAW SRM 51-72-11 AND DWG D53231533.SDR DALA2016030201578Stringer · corrodedCORROSION ON STRINGER 44 BETWEEN FRAMES 61 TO 62. REPLACED THE STRINGER IAW SRM 51-72-11 AND DWG D53470345.SDR DALA2016022401810Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1292 AT FWD GALLEY AREA FROM FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110900.SDR DALA2016030201581Hinge Fitting · wornWEAR ON FWD HINGE FITTING OF RT MLG DOOR ON KEELBEAM IN MAIN WHEEL WELL, INNER FACE. REPLACED HINGE FITTING OF RT MLG DOOR ON KEELBEAM IN MAIN WHEEL WELL, INNER FACEIAW SRM 51-72-11 AND DWG D53370600.SDR DALA2016022301809Floor Support · corrodedCORROSION ON FLOOR SUPPORT -465 AT AFT GALLEY AREA BETWEEN FRAME 67+10" TO FRAME 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53472195.SDR DALA2016022301808Floor Support · corrodedCORROSION ON FLOOR SUPPORT -1162 AT AFT GALLEY AREA BETWEEN FRAME 67+15" TO FRAME 69. REPLACED FLOOR SUPPORT IAW SRM 51-72-11, DWG D53472800.SDR DALA2016022301475Floor Support · corrodedCORROSION AFT GALLEY AREA ON LOWER SILL FR 66-FR 68 AT LEVEL STR 23L MEASURES APPROXIMATELY L:0.600", W:0.270", D:0.003". REPLACED LOWER SILL FR 66-FR 68 AT LEVEL, STR 23L AT AFT GALLEY AREA ASPER SRM 51-72-11 AND DWG D53480020, THE DEEPEST POINT MEASURE IS: SDR DALA2016022301474Floor Support · corrodedCORROSION ON FLOORBEAM +Y1225 AT AFT GALLEY AREA BETWEEN FRAME 66-FRAME 67+15''. MEASURE L=0.250", W=0.180", D=0.003", APPROXIMATELY. REPLACED FLOORBEAM Y1225 AT AFT GALLEY AREA BETWEEN FRAME 66 TO FRAME 67+15" SRM 51-72-11, DWG D53472000.SDR DALA2016022301473Floor Support · corrodedCORROSION ON FLOORBEAM +765 AT AFT GALLEY AREA BETWEEN FRAME 66-FRAME 70. MEASURE L=0.950", W=0.250", D=0.003" APPROXIMATELY. REPLACED FLOORBEAM +Y765 AT AFT GALLEY AREA FRAME 66 TO FRAME 70 IAW SRM 51-72-11, DWG 53472000.SDR DALA2016022201472Floor Support · corrodedCORROSION ON FLOORBEAM 465 AT AFT GALLEY AREA BETWEEN FRAME 64-FRAME 67+10''. MEASURE L=0.895", W=0.585", D=0.003", APPROXIMATELY. REPLACED FLOORBEAM -465 AT AFT GALLEY AREA BETWEEN FRAME 64 TO FRAME 67+ 10" IAW SRM 51-72-11, DWG D53472816.SDR DALA2016022001353Profile · crackedCRACK ON FWD LOAD TRANSMITTING PROFILE AFT EMERGENCY DOOR RT IN PASSENGER CABIN, REPLACED FWD LOAD TRANSMITTING PROFILE AFT EMERGENCY DOOR RT IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG D52279020.SDR DALA2016022001480Shear Tie · corrodedCORROSION ON CLEAT ON FRAME 26 IN FWD CARGO COMPARTMENT BETWEEN STR 43L TO STRINGER 43R. REPLACED CLEAT ON FR 26 IN FWD CARGO COMPARTMENT BETWEEN STR 43L TO STR 43R IAW SRM 51-72-11 AND DWG D53230324 AND D53231712.SDR DALA2016022001479Slat · damagedMISSING MATERIAL ON T/E SLAT 3 LOCATED 10 FROM INBD EDGE ON LT WING. PERFORMED PERMANENT REPAIR ON T/E SLAT 3 LOCATED AT 10" FROM INBD EDGE ON LT WING IAW SRM 57-44-21, PARA 5.A, FIG 202.SDR DALA2016021901478Floor Support · corrodedCORROSION ON FLOORBEAM +Y160, FRAME 68 TO FRAME 70 MEASURES APPROXIMATELY L=0.950, W=0.320, D=0.002 AT AFT GALLEY AREA. REPLACED FLOORBEAM, +Y160 LOCATED FRAME 68 TO FRAME 70 AFTER GALLEY AREA AND FASTENERS IAW SRM 51-72-11, 51-42-11 AND DWG D53474250.SDR DALA2016021901477Shear Tie · corrodedCORROSION ON SHEAR TIE LOCATED BETWEEN STR 41R AND STR 42R AT LEVEL FR 30 IN FWD CARGO COMPARTMENT L=0.300, W=0.200, D=0.002. REPLACED SHEAR TIE LOC BETWEEN STR 41R AND STR 42R AT FRAME 30 LEVEL FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231586.SDR DALA2016021901352Plate · corrodedCORROSION ON PLATE REINFORCEMENT IN FWD CARGO COMPARTMENT ON FRAME 26 AND STRINGER 41R.(MESURE L=0.985", W=0.250", D=0.006" APPROXIMATELY, REPLACED PLATE REINFORCING IN FWD CARGO COMPARTMENT ON FRAME 26 AND STRINGER 41R IAW SRM 51-72-11 AND 51-42-11 DWG D5323SDR DALA2016021901351Web · corrodedCORROSION ON WEB FRAME 20 AT FWD GALLEY AREA AND STR 23R, REPLACED WEB LOCATED FRAME 20 AT FWD GALLEY AREA AND STR 23R. IAW SRM 51-72-11 AND DWG D53114392 MEASURE OF CORROSION ARE: L=3.000", D=0.040".SDR DALA2016021601213Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765 BETWEEN FRAMES 12 - 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110984.SDR DALA2016021601212Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y254 BETWEEN FRAMES 12 - 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110900.SDR DALA2016021601211Floor Support · corrodedCORROSION ON LOWER SILL AT AFT GALLEY AREA ON STR 23L BETWEEN FRAME 66 TO FRAME 68. REPLACED LOWER SILL IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016021601184Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y254 , FRAMES 12 - 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110900.SDR DALA2016021601183Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 BETWEEN FRAMES 67+15 - 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472088.SDR DALA2016021601210Seat Track · corrodedCORROSION ON SEAT TRACK -Y1292 BETWEEN FRAMES 12 - 24. REPLACED THE SEAT TRACK IAW SRM 51-72-11 AND DWG D53112812.SDR DALA2016021601209Plate · crackedTWO CRACK INDICATIONS ON SIDE BOX BEAM AT FRAME 43 Y- 1650. REPLACED PREASURE PLATE IAW SRM 51-72-11.SDR DALA2016021601208Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y765, FRAMES 12 - 24 . REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D5311281, AND D53110900.SDR DALA2016021601207Plate · crackedTWO CRACK INDICATIONS ON SIDE BOX BEAM AT FRAME 43, Y+1650 ON CENTER WING BOX . REPLACED PRESSURE PLATE LT SIDE FRAME 43 IAW SRM 51-72-11.SDR DALA2016021601206Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y254, FRAMES 12 - 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110900.SDR DALA2016021701157Battery Pack · no testTESTED EMERGENCY LIGHTS THEY FAULTED FOR RT BATTERY PACK. REPLACED THE BATTERY PACK.SDR DALA2016021501205Shear Tie · corrodedCORROSION ON SHEAR TIE BETWEEN STRINGERS 40 - 41R AT FRAME 31. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231586.SDR DALA2016021501204Shear Tie · corrodedCORROSION ON SHEAR TIE BETWEEN STRINGERS 42 - 43R AT FRAME 32. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231712.SDR DALA2016021501203Shear Tie · corrodedCORROSION ON SHEAR TIE BETWEEN STRINGERS 43 - 44L , FRAME 31. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231712.SDR DALA2016021501202Shear Tie · corrodedCORROSION ON SHEAR TIE BETWEEN STRINGERS 41 - 42R AT FRAME 31. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231586.SDR DALA2016021501201Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y254, FRAME 20+5. REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 TO 24 IAW SRM 51-72-11 AND DWG D53112816.SDR DALA2016021501200Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1162, FRAMES 67+15 TO 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND DWG D53472800.SDR DALA2016021501199Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1225 FRAMES 66+5" TO 67+15. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND DWG B53472800.SDR DALA2016021401198Shear Tie · corrodedCORROSION ON SHEAR TIE LOCATED BETWEEN STR 40R TO STR 41R AT LEVEL FRAME 30. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231586.SDR DALA2016021501156Dummy Rail · corrodedCORROSION ON RAIL DUMMY -Y189 AT FWD GALLEY AREA FROM FRAME 20 TO FRAME 24. REPLACED RAIL DUMMY IAW SRM 51-72-11 AND DWG D53111406.SDR DALA2016021501155Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y254 AT FWD GALLEY AREA FROM FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53112816 AND DWG D53110984.SDR DALA2016021501190Floor Support · corrodedCORROSION ON FLOORBEAM +Y1162, FRAME 67+15" TO FRAME 69 MEASURES APPROXIMATELY L:0.600", W:0.300", D:0.002", SSI 534147 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1162 LOCATED BETWEEN FRAME 67+15" TO FRAME 69 IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016021401197Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1225 AT AFT GALLEY AREA BETWEEN FRAMES 66+5 TO 67+15. REPLACED T. MEASURES OF CORROSION ARE L=0.500", W=0.235", D=0.028".SDR DALA2016021301196Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1225, FRAMES 66+5" TO 67+15". REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016021301195Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 LOCATED FRAMES 12 TO 16. REPLACED THE RAIL DUMMY IAW SRM 51-72-11 AND DWG D53112825.SDR DALA2016021301194Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765, FRAMES 66+5" TO 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016021401043Power Supply · no testEMERGENCY SYS TEST FAULTS ESPU UNIT EMERGENCY LIGHT, REPLACED EMERGENCY POWER SUPPLY UNIT W/O BATTERY.SDR DALA2016021001193Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765 AT AFT GALLEY AREA BETWEEN FRAMES 67 TO 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.
Back to Airbus A320-212