Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA108213260Floorbeam · damagedDURING M-CHECK FOUND DOUBLE DRILLED FLOOR SUPPORT BEAM AT Y1292 FR66. REPAIRED IAW SRM53-41-15, 51-42-11, 51-75-12.SDR DALA108173260Web · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR WEB AT Y1732 FR20. REPAIRED PER 51-42-11.SDR DALA108133263Power Supply · inoperativeDURING GEAR EXTENTION, THE EMERGENCY EXIT LIGHT IN CEILING MID CABIN CAME ON MOMENTARILY AND WENT OUT. MX REPLACED POWER SUPPLY AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA107943250Floor Panel · corrodedDURING H-CHECK FOUND CORROSION ON AFT CARGO COMPARTMENT FLOOR PANEL 151KF. REPAIRED IAW SRM 53-02-00.SDR DALA107873260Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON LT AFT CABIN FLOORBEAM AT Y765 FR66-FR70. REPAIRED IAW SRM 51-42-11, 51-44-11, 53-21-01.SDR DALA107953250Skin · gougedDURING H-CHECK FOUND GOUGES IN FUSELAGE INTERNAL SKIN IN AFT GALLEY AREA BETWEEN FR69-FR70, S23R-S24R. REPAIRED IAW SRM 53-41-11.SDR DALA107933250Floor Panel · damagedDURING H-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 161AF. REPAIRED IAW DWG 3D25-37705.SDR DALA107923250Floor Panel · damagedDURING H-CHECK FOUND DAMAGE TO FWD CARGO FLOOR PANEL 131HF. REPAIRED IAW DWG 3D25-37705.SDR DALA107913250Threshold · corrodedDURING H-CHECK FOUND CORROSION ON FWD CARGO THRESHOLD PANEL 132DF. REPAIRED IAW SRM 53-22-14.SDR DALA107903250Floor Panel · damagedDURING H-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 151PF. REPAIRED IAW DWG 3D25-37705.SDR DALA107893250Floor Panel · damagedDURING H-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 151AF. REPAIRED PER DWG 3D25-37705.SDR DALA107883250Floor Panel · damagedDURING H-CHECK FOUND DAMAGE TO AFT CARGO FLOOR PANEL 151DF. REPAIRED IAW DWG 3D25-37705.SDR DALA107713250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON RT FLOOR SUPPORT BEAM AT Y1292, FR64-FR66. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107693266Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 5L INOPERATIVE. MX REPAIRED WIRING AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA107683265Wire · disconnectedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 1L, 16L, AND 19L INOPERATIVE. MX RECONNECTED WIRING AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA107633250Floor Support · corrodedDURING H-CHECK FOUND FLOOR SUPPORT CORRODED AROUND NUT PLATE IN AFT CARGO COMPARTMENT AT STRINGER 38L BETWEEN FR54-FR55. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107623250Floor Panel · damagedDURING H-CHECK FOUND AFT CARGO FLOOR PANEL 151LF DAMAGED. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA107613250Floor Panel · damagedDURING H-CHECK FOUND AFT CARGO FLOOR PANEL 151GF DAMAGED. REPLACED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA107603250Floor Panel · damagedDURING H-CHECK FOUND FWD CARGO FLOOR PANEL 131EF DAMAGED. REPAIRED IAW DWG 3D25-37705.SDR DALA107543250Floor Support · corrodedDURING H-CHECK FOUND FLOOR SUPPORT CORRODED AROUND NUT PLATE IN AFT CARGO COMPARTMENT AT STRINGER 38R BETWEEN FR50-FR51. REPAIRED IAW SRM 51-42-11, 51-21-11, 51-75-12.SDR DALA107383244Terminal · looseDURING A NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT 23C INOPERATIVE. MX RECONNECTED A LOOSE TERMINAL AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA107473250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y254 FR19 & FR20. REPAIRED IAW ERA 13-480950-14 SECTION I.SDR DALA107463250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON LT FLOOR SUPPORT BEAM AT Y1292 BETWEEN FR64 AND FR66. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107453250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON RT FLOOR SUPPORT BEAM AT Y1292 BETWEEN FR68 AND FR69. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107443250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON RT FLOOR SUPPORT BEAM AT Y1292 BETWEEN FR66 AND FR68. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107433250Floor Support · corrodedDURING H-CHECK, FOUND CORROSION ON LT FLOOR SUPPORT BEAM AT Y254 BETWEEN FR12 AND FR24. REPAIRED IAW SRM 51-42-11.SDR DALA107423250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON LT FLOOR SUPPORT BEAM AT +Y1292 BETWEEN FR68 AND FR69. REPAIRED IAW SRM 51-42-11.SDR DALA107403250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON LT FLOOR SUPPORT BEAM AT +Y1292 BETWEEN FR66 AND FR68. REPAIRED IAW SRM 51-42-11.SDR DALA107393250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y765 FR16 & FR20. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA107273250Floor Panel · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR PANEL 222FF. REPAIRED IAW WC 2500-0617.SDR DALA1007263250Sill · corrodedDURING H-CHECK FOUND CORROSION ON FWD AND AFT L2 DOOR SILL. REPAIRED IAW SRM 51-42-11 AND 51-44-11.SDR DALA107233250Sill · corrodedDURING H-CHECK, FOUND CORROSION ON R2 DOOR SILL FWD AND AFT AREA. REPAIRED IAW SRM 51-42-11.SDR DALA107223250Fitting · crackedDURING H-CHECK FOUND L2 DOOR FWD CORNER FITTING IS CRACKED. REPAIRED IAW SRM 51-42-11.SDR DALA107213250Floorbeam · corrodedDURING H-CHECK FOUND CORROSION ON FLOORBEAM INBD UPPER SPLICE AROUND 2 FASTENER HOLES AT Y1292, FR66. REPAIRED IAW SRM 51-42-11.SDR DALA107093250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y1292 FR12-FR24. REPAIRED IAW SRM 51-42-11.SDR DALA107183238Power Supply · inoperativeDURING A NON ROUTINE CHECK FOUND EMERGENCY ESCAPE PATH LIGHT INOPERATIVE. MX REPLACED THE POWER SUPPLY AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA106933250Sill · corrodedDURING H-CHECK FOUND CORROSION ON R2 DOOR CTR SHAPE SILL. REPAIRED IAW SRM 51-42-11, SRM 51-44-11.SDR DALA106923250Sill · corrodedDURING H-CHECK FOUND CORROSION ON LT AFT DOOR SILL CORNER FITTING AT FR68. REPAIRED IAW SRM 51-44-11, 51-42-11.SDR DALA106913250Sill · corrodedDURING H-CHECK FOUND CORROSION ON RT AFT DOOR SILL CORNER FITTING AT FR 68. REPAIRED IAW SRM 51-44-11, 51-42-11.SDR DALA106903250Floor Support · corrodedDURING H-CHECK FOUND FLOOR SUPPORT BEAM CORRODED AT Y1584 FR20. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA106893250Floor Support · corrodedDURING H-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT -Y765 FR20-FR21. REPAIRED IAW SRM 51-42-11, 51-44-11.SDR DALA106883250Floor Support · corrodedDURING H-CHECK FOUND FLOORBEAM CORRODED AT Y765 FR66 TO FR70. REPAIRED IAW SRM 51-44-11, 51-42-11.SDR DALA106873250Fitting · damagedDURING H-CHECK FOUND DAMAGE TO FWD CABIN SUPPORT BEAM CONNECTING FITTING AT -Y254 FR12. REPAIRED IAW SRM 51-42-11.SDR DALA106413264Structure · misrepairedDURING M-CHECK WHILE ACCOMPLISHING DOOR SILL REPLACEMENT AT DOOR R2 FOUND 7 MISDRILLED FASTENER HOLES BETWEEN FR66 AND FR68. THE HOLES ARE COMMON TO THE FUSELAGE SKIN, DOUBLER AND DOOR SILL. ERA 480602-14 REPAIR TO BE ACCOMPLISHED AS FOLLOWS: SECTION I ACCOMPSDR DALA106483264Stringer · crackedDURING M-CHECK FOUND STRINGER 23R CRACKED AROUND RIVET. REPAIRED IAW ERA 480944-14, SRM 51-44-11, 51-21-11, 51-42-11.SDR DALA106613250Floorbeam · corrodedDURING L-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y512 FR64-FR66. REPAIRED IAW SRM 51-42-11.SDR DALA106533250Floor Support · corrodedDURING "H" CHECK, FOUND FLOOR SUPPORT CORRODED AT +Y503, FR12 TO 16. R & R FLOOR SUPPORT, IAW SRM 51-42-11, 51-75-12, AND 51-21-11.SDR DALA106423264Floor Panel · damagedDURING M-CHECK, FOUND FLOOR PANEL 131HF DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA106723264Seat Track · corrodedDURING M-CHECK FOUND SEAT TRACK -Y1292 CORRODED BETWEEN FR 64 AND 66. REPLACED SEAT TRACK IAW SRM 51-42-11, AND 51-44-11.SDR DALA106813264Floor Panel · corrodedDURING M-CHECK FOUND FLOOR PANEL 261FF CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-00.
Back to Airbus A320-212