Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011062700024Stiffener · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON STIFFENER ASSEMBLY AT FR12 BETWEEN -Y1292 TO -Y254. REPLACED STIFFENER ASSEMBLY AT FR12 BETWEEN -Y1292 TO -Y254 IAW A320 SRM 51-72-11.SDR USAA2011062700019Floor Support · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, -Y254. REPLACED SUPPORT FLOOR BETWEEN FR12 TO FR24, -Y254 IAW A320 SRM 51-72-11& AIRBUS DRAWING D53110900 & D53111462.SDR USAA2011062700013Dummy Rail · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, -Y81. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, -Y81 IAW A320 SRM 51-72-11& AIRBUS DRAWING D53112829.SDR USAA2011062700011Angle · corrodedSAL - 2S - LEVEL 2 FILIFORM CORROSION ON ANGLE BETWEEN FR12 TO FR14, S23R. REPLACED ANGLE BETWEEN FR12 TO FR14, S23R IAW A320 SRM 51-72-11.SDR USAA2011062400026Dummy Rail · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR21 TO FR24, -Y189. REPLACED RAIL DUMMY BETWEEN FR21 TO FR24, -Y189 IAW A320 SRM 51-72-11, 51-42-11 & AIRBUS DRAWING D53111414.SDR USAA2011062400024Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23L. REPLACED CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112175.SDR USAA2011062400022Floor Support · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254. REPLACED SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53110900.SDR USAA2011062400021Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR32 BETWEEN S43R TO S44R. REPLACED SHEAR TIE AT FR32 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062400005Dummy Rail · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, S23R. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, S23R IAW A320 SRM 51-72-11.SDR USAA2011062400003Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR19 + 6 INCHES, S23L. REPLACED PLATE AT FR19 + 6 INCHES, S23L IAW A320 SRM 51-72-11.SDR USAA2011062400002Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR16 + 4 INCHES, S23L. REPLACED PLATE AT FR16 + 4 INCHES, S23L IAW A320 SRM 51-72-11.SDR USAA2011062400001Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR16 + 3 INCHES, S23R. REPLACED PLATE AT FR16 + 3 INCHES, S23R IAW A320 SRM 51-72-11.SDR F3LA2011060300655Skin · puncturedACFT LP 605289: DURING OPERATIONS, ACFT WAS CAUGHT IN A SEVER HAIL STORMS. THE STORM RESULTED IN PENETRATING DAMAGE TO THE LT ELEVATOR IN (3) LOCATIONS. NR L - A 172.4 INCHES FROM THE INBD EDGE. 10.25 INCHES FROM THE T/E, .9 INCHES WIDE. NR 2 - A 125.0 INCHESDR USAA2011060200003Mechanism · obstructedPHL - EES - WHILE AIRBORNE, FLIGHT ATTENDANTS REPORTED THAT THE 2L DOOR INDICATION WAS BLINKING ON AND OFF AND THE HANDLE WOULD NOT STAY IN THE ARMED POSITION. ECAM DOOR/OXY PAGE INDICATED SLIDE WAS NOT ARMED. MAINTENANCE FOUND LIQUOR KIT SEAL ENTRAPPED IN ASDR USAA2011070100023Fitting · corrodedSAL - 2S CHECK - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR30 BETWEEN STR40R TO STR41R. REPLACED CLEAT AT FR30 BETWEEN STR40R TO STR41R IAW A320 SRM 51-72-11 AND AIRBUS DRAWING D53231712.SDR USAA2011070100014Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR27 BETWEEN S43R TO S44R. REPLACED CLEAT AT FR27 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800044Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR28 BETWEEN S43R TO S44R. REPLACED CLEAT AT FR28 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800018Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR30 BETWEEN S40L TO S41L. REPLACED CLEAT AT FR30 BETWEEN S40L TO S41L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800017Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR26 BETWEEN S41L TO S42L. REPLACED CLEAT AT FR26 BETWEEN S41L TO S42L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062400028Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT (SHEAR TIE) AT FR30 BETWEEN S41R TO S42R. REPLACED CLEAT (SHEAR TIE) AT FR30 BETWEEN S41R TO S42R IAW A320 SRM 51-72-11.SDR USAA2011062400023Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR29 BETWEEN S40L TO S41L. REPLACED SHEAR TIE AT FR29 BETWEEN S40L TO S41L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011060100004Battery · dischargedLAS - EEL - FIRST CLASS FLIGHT ATTENDANT'S EMERGENCY FLASHLIGHT NEEDS BATTERY REPLACEMENT. MAINTENANCE REPLACED FIRST CLASS EMERGENCY FLASHLIGHT BATTERY AS REQUIRED & ADDED SECURITY STRAP.SDR USAA2011070100020Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON RUDDER HINGE FITTING NR 2 AT RS1926, RIB 4. REPLACED RUDDER HINGE FITTING NR 2 AT RS1926, RIB 4 IAW A320 AMM 55-36-41.SDR USAA2011070100019Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON RUDDER HINGE FITTING NR 4 AT RS2632, RIB6. REPLACED RUDDER HINGE FITTING NR 4 AT RS2632, RIB 6 IAW A320 AMM 55-36-41.SDR USAA2011070100018Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON NR 5 RUDDER HINGE FITTING AT RS2985, RIB 7. REPLACED NR 5 RUDDER HINGE FITTING AT RS2985, RIB7 IAW A320 AMM 55-36-41.SDR USAA2011053100009Epsu · defectiveLAS - ODOR - ON GATE ARRIVAL AFTER ENGINE SHUTDOWN, NOTICED STRONG CHEMICAL ODOR IN COCKPIT AND FORWARD LAV - NOT PRESENT IN CABIN. MAINTENANCE FOUND FORWARD LT EMERGENCY POWER SUPPLY UNIT FAULTING. REMOVED AND REPLACED EPSU IAW AIRBUS MAINTENANCE MANUAL 33-SDR USAA2011053100012Wire · looseLAX - EEL - EMERGENCY POWER SUPPLY UNIT (EPSU) FIN#13WL FAILED TEST AFTER BATTERY REPLACEMENT. EXTERIOR LIGHT FAULT INDICATION. PERFORMED TROUBLESHOOTING PROCEDURE. FOUND LOOSE WIRE CONNECTOR ON R AFT DOOR SLIDE LIGHT. SECURED CONNECTOR. SYSTEM TEST GOOD.SDR USAA2011053100010Lens · missingORD - EEL - LENS MISSING ON EMERGENCY EXIT LIGHT ROW 9RT. INSTALLED LENS ON EMERGENCY EXIT LIGHT ROW 9RT.SDR USAA2011053100045Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 64 AND FR 69, BL Y1292. REPLACED FLOORBEAM BETWEEN FR 64 AND FR 69, BL Y1292 IAW A320 SRM 53-41-14.SDR VQI2011F00010Handle · damagedACFT HAD COMPLETED CATERING IN PREP FOR FLIGHT VX12. CATERING ATTEMPTED TO CLOSE THE L2 DOOR THAT WAS USED TO CATER THE FLIGHT, WHEN THEY NOTED THE EXTERNAL DOOR HANDLE WOULD NOT ENGAGE DURING THE CLOSING PROCESS. THE INSIDE HANDLE OPERATED NORMALLY. MX WASSDR F3LA2011051800640Proximity Switch · false activationC-CHECK: LT OVERWING EXIT DOOR SLICE ARMED LIGHT, ON SIDEWALL PANEL, WILL NOT GO OUT WITH THE DOOR REMOVED. R & R FWD LT EMERGENCY EXIT PROX SWITCH, OPS CHECKS GOOD AMM 52-73-11-00-003 AND 52-73-11-400-003. R & R LT SLICE ARMED INDICATOR LIGHT, OPS CHECKED GSDR USAA2011053100047Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR 66, BL -Y1732. REPLACED FLOORBEAM AT FR 66, BL -Y1732 IAW A320 SRM51-72-00 AND AIRBUS DRAWING D53427250.SDR VQI2011F00008Floor Support · corrodedFUSELAGE DETAIL INSP OF CABIN FLOOR STRUCTURE BELOW AFT GALLEY WAS ACCOMPLISHED. DURING THE INSP, CORROSION WAS FOUND ON 1 LONGERON BEAM (Y=464.8) WHICH EXCEEDED SRM 53-00-14 ALLOWABLE LIMITS. LONGERON BEAM (PN D53472284008) WAS REPLACED.SDR USAA2011053100031Fitting · corrodedPIT - S5 - CHECK LEVEL 2 EXFOLIATION CORROSION ON DOOR FRAME SILL FITTING 1.25 INCHES FORWARD OF FR 68, STR 23R. REPLACED DOOR FRAME SILL FITTING 1.25 INCHES FORWARD OF FR 68, STR 23R IAW A320 SRM 51-72-11.SDR MU1Z2011020200006Skin · dentedDURING SERVICE OF 20 MONTHS FOUND TWO DENTS BETWEEN FRAME 16 AND 18 DOWN OF LT STRINGER 5. DENT 2 IS OUT OF LIMITS BECAUSE IS AT 13.5 MM FROM THE STR 5 LT DENT 1 IS ON LIMITS, PERFORMED INTERNAL AND EXTERNAL HIGH FREQUENCY EDDY CURRENT INSPECTIONS PER CRACKS SDR USAA2011060300014Attach Fitting · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON CARGO BIN FRAME ATTACH FITTING AT FR 31, BETWEEN STR 40R TO STR 41R. REPLACED CARGO BIN FRAME ATTACH FITTING AT FR 31, BETWEEN STR 40R TO STR 41R IAW A320 SRM 51-42-11.SDR USAA2011053100036Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION ON FLOORBEAM AT FR 24, BL -Y1292. REPLACED FLOORBEAM AT FR 24, BL -Y1292 IAW A320 SRM 51-72-11.SDR USAA2011053100035Floorbeam · corrodedPIT - S5 CHECK LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 20 TO FR 21, BL Y765. REPLACED FLOORBEAM BETWEEN FR 20 TO FR 21, BL Y765 IAW A320 SRM 51-72-11.SDR USAA2011053100034Support Angle · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON SUPPORT ANGLE AT FR 20, BL Y1600. REPLACED SUPPORT ANGLE AT FR 20, BL Y1600 IAW A320 SRM 51-72-11.SDR USAA2011053100033Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM 6 INCHES FORWARD OF FR 66, BL -Y465. REPLACED FLOORBEAM 6 INCHES FORWARD OF FR 66, BL -Y465 IAW A320 SRM 51-43-00.SDR USAA2011053100032Sill · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON DOOR SILL BETWEEN FR 66 T0 68, BL -Y1292. REPLACED DOOR SILL BETWEEN FR 66 T0 68, BL -Y1292 IAW A320 SRM 53-41-14 AND AIRBUS DRAWING D53480505.SDR USAA2011053100028Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR 20, BL -Y765. REPLACED FLOORBEAM AT FR 20, BL -Y765 IAW A320 SRM 51-72-11.SDR USAA2011053100030Floorbeam · corrodedPIT - S5 CHECK - EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 16 TO FR 21, BL -Y1292. REPLACED FLOORBEAM BETWEEN FR 16 TO FR 21, BL -Y1292 IAW SRM 51-72-11.SDR USAA2011053100029Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 66 TO FR 68, BL -Y765. REPLACED FLOORBEAM BETWEEN FR 66 TO FR 68, BL -Y765 IAW A320 SRM 51-72-11.SDR USAA2011053100027Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 18 TO FR 21, BL Y254. REPLACED FLOORBEAM BETWEEN FR 18 TO FR 21, BL Y254 IAW A320 SRM 51-72-11.SDR USAA2011053100026Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR 14, BL -Y81. REPLACED FLOORBEAM AT FR 14, BL -Y81 IAW A 320 SRM 51-71-11, DWG D53112829.SDR USAA2011053100025Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR 16, BL Y503. REPLACED FLOORBEAM AT FR 16, BL Y503 IAW A320 SRM 51-72-11.SDR USAA2011053100024Floorbeam · corrodedPIT - S5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 16 TO FR 24, BL Y1292. REPLACED FLOORBEAM BETWEEN FR 16 TO FR 24, BL Y1292 IAW A320 SRM 51-72-11.SDR USAA2011053100023Floorbeam · corrodedPIT - S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 66 TO FR 67, BL Y765. REPLACED FLOORBEAM BETWEEN FR 66 TO FR 67, BL Y765 IAW A320 SRM 51-72-11.SDR USAA2011053100022Sill · corrodedPIT - S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON DOOR SILL BETWEEN FR 66 TO FR 68, BL 1160. REPLACED DOOR SILL BETWEEN FR 66 TO FR 68, BL 1160 IAW AIRBUS DWG 18D53480020.
Back to Airbus A320-214