Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2010120192727Seat Track · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON SEAT TRACK BETWEEN FR24 TO FR35, -Y1292. REPLACED SEAT TRACK BETWEEN FR24 TO FR35, -Y1292 IAW A320 SRM 5-72-11 & AIRBUS DRAWING D53110920.SDR USAA2010121292993Coupling · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON COUPLING (SPLICE) AT FR68, -Y254. REPLACED COUPLING (SPLICE) AT FR68, -Y254 IAW A320 SRM 51-72-11 & AIRBUS DRAWING.SDR USAA2010121092976Coupling · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON COUPLING AT FR68, -Y254. REPLACED COUPLING AT FR68, -Y254 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2010120792908Bolt · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON RIGHT WING UPPER BOLT OF NR 6 SLAT TRACK BETWEEN WS 6132 TO WS 7316 & BETWEEN RIB 11 TO RIB 13. REPLACED RIGHT WING UPPER BOLT OF NR 6 SLAT TRACK BETWEEN WS 6132 TO WS 7316 & BETWEEN RIB 11 TO RIB 13 IAW A320 AMM 27-84-6SDR USAA2010120792907Bolt · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON RIGHT WING LOWER BOLT OF NR 2 SLAT TRACK BETWEEN WS 1406 TO WS 2580 & BETWEEN RIB 3 TO RIB 5. REPLACED RIGHT WING LOWER BOLT OF NR 2 SLAT TRACK BETWEEN WS 1406 TO WS 2580 & BETWEEN RIB 3 TO RIB 5 IAW A320 AMM 27-84-63.SDR USAA2010120192723Seat Track · corrodedMAJOR REPAIR - CORROSION ON SEAT TRACK BETWEEN FR36 TO FR41, -Y1292. REPLACED SEAT TRACK BETWEEN FR36 TO FR41, -Y1292 IAW SRM 51-72-11 & DRAWING D53370500.SDR USAA2010121493063Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON UPPER FLANGE INBOARD SIDE OF LOWER SILL AT FR66, S23L. REMOVED CORROSION FROM UPPER FLANGE INBOARD SIDE OF LOWER SILL AT FR66, S23L BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121293001Floor Panel · delaminatedSAL - S5 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL 261PF ON AFT RIGHT SECTION BETWEEN FR68 TO FR70 & BETWEEN -Y1732 TO Y1292. REPLACED FLOOR PANEL 261PF ON AFT RIGHT SECTION BETWEEN FR68 TO FR70 & BETWEEN -Y1732 TO Y1292 IAW JOB CARD 26C26053014.SDR USAA2010121293000Floor Panel · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON FLOOR PANEL 261BG BETWEEN FR64 TO FR66 & BETWEEN Y765 TO Y1732. REPLACED FLOOR PANEL 261BG BETWEEN FR64 TO FR66 & BETWEEN Y765 TO Y1732 IAW JOB CARD 26C26053014.SDR USAA2010120892912Splice · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON SPLICE AT LOWER POSITION OUTBOARD SIDE BETWEEN FR67 TO FR68, S23R. REPLACED SPLICE AT LOWER POSITION OUTBOARD SIDE BETWEEN FR67 TO FR68, S23R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472040.SDR USAA2010120792906Bolt · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON RIGHT WING UPPER BOLT OF NR 2 SLAT TRACK BETWEEN WS 1406 TO WS 2580 & BETWEEN RIB 3 TO RIB 5. REPLACED RIGHT WING UPPER BOLT OF NR 2 SLAT TRACK BETWEEN WS 1406 TO WS 2580 & BETWEEN RIB 3 TO RIB 5 IAW A320 AMM 27-84-63.SDR USAA2010121092972Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR68 TO FR70, -Y168. REPLACED FLOORBEAM BETWEEN FR68 TO FR70, -Y168 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2010120192736Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y254. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y254 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2010120192735Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67 + 10 INCHES, Y512. REPLACED FLOORBEAM BETWEEN FR64 TO FR67 + 10 INCHES, Y512 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472815.SDR USAA2010120192734Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 TO FR70, Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR70, Y765 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.SDR USAA2010120192733Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR66 + 1 INCH, Y765. REPLACED FLOORBEAM AT FR66 + 1 INCH, Y765 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D534720000.SDR USAA2010120192732Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67, -Y465. REPLACED FLOORBEAM BETWEEN FR64 TO FR67, -Y465 IAW A320 SRM 51-72-11.SDR USAA2010111592603Bottle · low pressureFLT 787 - CLT-ATL - EMERGENCY EGRESS SYSTEM - DOOR ASSIST BOTTLE FOR R1 DOOR LOW. SERVICED DOOR ASSIST BOTTLE PER AMM 52-10-0-001.SDR F3LA2010111400548Module · looseC-CHECK: NON ROUTINE N0694; EMERGENCY EXIT LIGHTS ON SEAT ROWS 16 AND 24 ARE INOP. RETERMINATED PINS ON EMERGENCY EXIT LIGHT CONNECTORS AT SEATS 16 LT AND 24 LT IAW AMM 33-51-19-020-051, STEP 4A1C AND AMM 33-51-19-420-051 STEP 4B1B. OPS CHECK GOOD IAW AMM 33-SDR F3LA2010111400547Floorbeam · corrodedC-CHECK: NON ROUTINE N0566; MAIN CABIN FLOORBEAM RT SIDE NR4 BETWEEN FRAME 67-69, CORROSION ON BOTTOM SIDE OF FLOORBEAM AT FASTENER HOLE. R & R FLOORBEAM IAW SRM 51-72-11, PAGE 1 AND 2.SDR F3LA2010111400546Plate · corrodedC-CHECK: NON ROUTINE N0561; AFT GALLEY UNDERFLOOR STRUCTURE RT LATERAL SHEAR PLATE BETWEEN FRAME 69 AND 70, HAS CORROSION AT 8 IN AFT OF FRAME 69 (ABOUT 2 SQUARE INCHES). R & R SHEARPLATE IAW SRM 51-42-11.SDR F3LA2010111400545Sill · corrodedC-CHECK: NON ROUTINE N0558; MAIN CABIN FLOOR AT FRAME 68L FLOOR SUPPORT HAS CORROSION APPROX 25 SQ IN AT THE FASTENER HOLES. CORROSION ON FLOOR SILL. REMOVED CORROSION ON L-2 DOOR SILL AT FRAME 68 IAW SRM 51-74-00 BLEND OUT FOUND TO BE OUT OF LIMITS, REPAIREDSDR F3LA2010111400544Floorbeam · corrodedC-CHECK: NON ROUTINE N0557; MAIN CABIN FLOORBEAM, NR 4 LT BETWEEN FRAME 67-68 HAS APPROX 2 SQ IN OF CORROSION AT THE FASTENER HOLES. R & R FLOORBEAM IAW SRM 51-44-11, SRM 51-42-11.SDR F3LA2010111400543Floor Panel · delaminatedC-CHECK: NON ROUTINE N0401; FLOORBOARD UNDER LAV E IS DELAMINATED. FABRICATED REPLACEMENT PANEL IAW MCG IRM 9701 REV G.SDR F3LA2010111400542Transition Panel · debondedC-CHECK: NON ROUTINE N0291; FWD CARGO TRANSITION PANEL 132FF UPPER SURFACE DEBONDED 6 SQ IN. FABRICATED REPLACEMENT PANEL IAW MCG IRM 9701, REV G.SDR F3LA2010111400541Transition Panel · delaminatedC-CHECK: NON ROUTINE N0289; FWD CARGO TRANSITION PANEL 132GF UPPER SURFACE IS DELAMINATED IN 2 PLACES, 2 SQUARE IN, 4 SQUARE IN. FABRICATED REPLACEMENT PANEL IAW MCG IRM 9701, REV G.SDR F3LA2010111400540Floor Panel · corrodedC-CHECK: FWD CARGO PIT TRANSITION FLOOR PANEL 131BF UPPER SURFACE AFT END DISBOUNDED 8 SQUARE INCHES. FABRICATED TRANSITION PANEL IAW MCW IRM 9701 REV G.SDR F3LA2010111400539Floor Panel · puncturedC-CHECK: NON ROUTINE N0286; FWD CARGO TRANSITION FLOOR PANEL 131BF HAS A 1 SQUARE IN PUNCTURE. FABRICATED REPLACEMENT PANEL IAW MCG 9701, REV G.SDR F3LA2010111400538Cover · gougedC-CHECK: NON ROUTINE N0138; FWD CARGO DOOR INTERNAL SIDE HAS 2.5 INCHES ABOVE THE LOWER DOOR SEAL AND 26.5 INCHES FWD AFT DOOR SEAL IS GOUGED, THAT MEASURES 1/8 INCH WIDE BY 3/4 INCH LONG BY .008 INCH DEEP. REPAIRED IAW A320SRM 52-31-00 PARAGRAPH (O).SDR F3LA2010111400537Seal · gougedC-CHECK: NON ROUTINE N0134; AFT CARGO DOOR INTERNAL SIDE HAS 2 IN ABOVE THE LOWER SEAL AND 25 INCHES OF FWD SEAL IS GOUGED THAT MEASURES .3750 IN WIDE X .7500 IN LONG X 0018 INCH DEEP. REPAIRED IAW SRM 52-31-00, PARAGRAPH (O)SDR F3LA2010111400536Panel · gougedC-CHECK: NON ROUTINE N0132; AFT CARGO DOOR INTERNAL SIDE HAS A 2.5 INCHES ABOVE THE LOWER DOOR SEAL AND 27 INCHES FWD OF AFT SEAL IS A GOUGE THAT MEASURES .7500 IN WIDE BY 1 IN LONG BY .090 IN DEEP. REPAIRED IAW SRM 52-30-00, PARAGRAPH (O).SDR USAA2010121493062Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON LOWER SILL AT FR66, S23R. REMOVED CORROSION FROM LOWER SILL AT FR66, S23R BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121493057Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON LOWER SILL AT FR66, S23L. REPAIRED LOWER SILL AT FR66, S23L IAW EA 133213.SDR USAA2010121092984Door · out of adjustSAL - S5 - MAJOR REPAIR - R1 DOOR IS OUT OF ADJUSTMENT AT DIMENSION 'B' BETWEEN FINGER & STRIKER LEVER. PERFORMED ADJUSTMENT OF DIMENSION 'B' (J1) BETWEEN FINGER & STRIKER LEVER DAMPER IAW A320 AMM 52-11-14-820-002.SDR USAA2010120892928Floorbeam · corrodedSAL - MAJOR REPAIR - S5 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66 +5 INCHES, -Y765. REPLACED FLOORBEAM BETWEEN FR64 TO FR66 +5 INCHES, -Y765 IAW A320 SRM 51-72-11 AND AIRBUS DRAWING D53472000.SDR USAA2010120892920Pin · corrodedSAL - S5 - MAJOR REPAIR - CORROSION ON THREADS OF LEFT MAIN LANDING GEAR TORQUE LINK APEX PIN. REPLACED LEFT MAIN LANDING GEAR TORQUE LINK APEX PIN IAW A320 AMM 32-11-29.SDR USAA2010120892917Fitting · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON R2 DOOR CENTER FITTING BETWEEN FR18 TO FR18 + 10 INCHES, S23R. REPLACED R2 DOOR CENTER FITTING AT FR67 BETWEEN S22L & S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112109.SDR USAA2010120892916Fitting · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON CENTER FITTING BETWEEN FR16 TO FR20, S23L. REPLACED CENTER FITTING BETWEEN FR16 TO FR20, S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112109.SDR USAA2010120892915Fitting · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON L1 DOOR CORNER FITTING AT FR20, S23L. REPLACED L1 DOOR CORNER FITTING AT FR20, S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112109.SDR USAA2010120292769Seat Track · corrodedMAJOR REPAIR - CORROSION ON SEAT TRACK BETWEEN FR36 TO FR41, Y1292. REPLACED SEAT TRACK BETWEEN FR36 TO FR41 IAW 51-72-11 DRAWING 53371000.SDR USAA2010120192731Floorbeam · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR70, -Y765. REPLACED FLOORBEAM BETWEEN FR66 + 5 INCHES TO FR70, -Y765 IAW A320 SRM 51-72-11.SDR USAA2010121493060Sill · corrodedMAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON LOWER SILL AT FR66 + 2 INCHES, S23L. REMOVED CORROSION FROM LOWER SILL AT FR 66 + 2 INCHES, S23L BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121493059Web · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FUSELAGE FLOOR STRUCTURE WEB AT FR20, -Y1732. REPAIRED FUSELAGE FLOOR STRUCTURE WEB AT FR20, -Y1732 IAW EA 133181.SDR USAA2010121493065Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON LOWER SILL AT FR67 + 18 INCHES, S23L. REMOVED CORROSION FROM LOWER SILL AT FR67 + 18 INCHES, S23L BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121493064Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON LOWER SILL UPPER & LOWER SURFACES AT FR67 + 18 INCHES, S23R. REMOVED CORROSION FROM LOWER SILL UPPER & LOWER SURFACES AT FR67 + 18 INCHES, S23R BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121493061Sill · corrodedSAL - S5 - MAJOR REPAIR - GALVANIC CORROSION ON LOWER SILL AT FR66 + 3 INCHES, S23R. REMOVED CORROSION FROM LOWER SILL AT FR66 + 3 INCHES, S23R BLENDED WITHIN LIMITS IAW EA 133182.SDR USAA2010121292999Shear Plate · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, S23R. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, S23R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53470100.SDR USAA2010121292998Fitting · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON LOWER CORNER FITTING AT FR66, S23R. REPLACED LOWER CORNER FITTING AT FR66, S23R IAW A320 SRM 51-72-11.SDR USAA2010121292996Seat Track · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON UPPER OUTBOARD FLANGE OF SEAT TRACK AT FR34 + 19 INCHES, Y1292. REPAIRED SEAT TRACK AT FR34 + 19 INCHES, Y1292 IAW A320 SRM & AIRBUS DRAWING D53231730.SDR USAA2010121292994Sill · corrodedSAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON SHAPE SILL CENTER FITTING BETWEEN FR66 TO FR68, S23L. REPLACED SHAPE SILL CENTER FITTING BETWEEN FR66 TO FR68, S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53480009 & D53480048.
Back to Airbus A320-214