Airbus A320-214
Service difficulty reports · 10,616
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320214' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202311301958Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 12WL FAILED FUNCTIONAL TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 12WL PER AMM 33-51-38.SDR AALA202311308841Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 11WL FAILED FUNCTIONAL TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 11WL PER AMM 33-51-38.SDR AALA202311307732Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 10WL FAILED FUNCTIONAL TEST. REPLACED EMERGENCY POWER SUPPLY UNIT 10WL PER AMM 33-51-38.SDR AALA202311309320Battery · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 13WL BATTERY FAILED FUNCTIONAL TEST. REPLACED BATTERY PER AMM 33-51-38.SDR AALA202311306562Battery · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 12WL BATTERY FAILED FUNCTIONAL TEST. REPLACED BATTERY PER AMM 33-51-38.SDR AALA202311304006Battery · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 11WL BATTERY FAILED FUNCTIONAL TEST. REPLACED BATTERY PER AMM 33-51-38.SDR AALA202311303839Battery · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 10WL BATTERY FAILED FUNCTIONAL TEST. REPLACED BATTERY PER AMM 33-51-38.SDR WX0A2023112731898Megaphone · unknownFWD MEGAPHONE BROKEN / REMOVED AND REPLACED THE FWD MEGAPHONE REF A320 LOPA EMERGENCY EQUIPMENT LAYOUT A2250006L03. OPS CHECK NORMAL."SDR AALA202312182338Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN SEAT TRACK BETWEEN FR 24 AND FR 27 AT -Y765. MAINTENANCE REPLACED SEAT TRACK PER SRM 51-42-11-801.SDR AALA202312148212Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION CABIN FLOOR SEAT TRACK BETWEEN FR 24 AND FR 27 AT -Y1292. REPLACED SEAT TRACK PER SRM 51-42-11.SDR AALA202311273699Damper · no testAIRCRAFT IN BASE MAINTENANCE: PASSENGER / CREW DOOR 832 DAMPER AND EMERGENCY OPERATION CYLINDER FAILED DAMPING FUNCTIONAL TEST. REPLACED DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-13-14 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202311275118Power Supply · no testAIRCRAFT WAS NOT GROUNDED: MULTIPLE EMERGENCY LIGHTS INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNITS 11WL (AALA202311273564) AND 12WL (AALA202311275118) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202311273564Power Supply · no testAIRCRAFT WAS NOT GROUNDED: MULTIPLE EMERGENCY LIGHTS INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNITS 11WL (AALA202311273564) AND 12WL (AALA202311275118) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202311249437Slide Raft · deformedAIRCRAFT IN BASE MAINTENANCE: L1 DOOR SLIDE RAFT IS DEFORMED. REPLACED SLIDE RAFT ASSEMBLY PER TASK CARD 26C83152008.SDR AALA202312076246Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SEAT TRACK BETWEEN FR 12 AND FR 24 AT -Y76. REPLACED SEAT TRACK PER SRM 51-42-11-801.SDR WX0A2023112231897Epsu · unknownEPSU (11WL) FAULTED / PERFORMED TSM 33-51-00-810-858-A REMOVED AND REPLACED EPSU (11WL) IAW A320 AMM 33-51-38-000-001 AND 33-51-38-400-001. OPERATIONAL TESTS PASS."SDR WX0A2023112031894Epsu · unknownEPSU (11WL) FAULTED / PERFORMED TSM 33-51-00-810-858-A REMOVED AND REPLACED EPSU (11WL) IAW A320 AMM 33-51-38-000-001 AND 33-51-38-400-001. OPERATIONAL TESTS PASS."SDR ASAA2023111949223Static Port · corrodedLH F/O AND LH CAPT STATIC PORTS WITH SIGNS OF CORROSION AROUND THE HOLES GROUNDED - YES. REMOVED AND REPLACED LH STATIC PORT REINFORCEMENT IAW A320-SRM-51-72-11, AIRBUS DWG: D53113482. OPS CHECK GOOD IAW A320-AMM-30-31-00-210-001-A. PROTECTIVE COATINGS WILL BESDR WX0A1900010031910Unknown · unknown(MAJOR REPAIR) ON R1 DOOR SILL BEAM UNDER AFT GIRT BAR MOUNTING PLATE, CORROSION FOUND AROUND FASTENERS (QTY.2) (FWD INBD AND AFT OUTBD) / R1 DOOR SILL BEAM AFT GIRT BAR MOUNTING PLATE, FWD INBD AND AFT OUTBD HOLES PERMANENTLY REPAIRED PER SRM 53-11-14-283-005SDR AALA202311205371Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 13WL INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNIT 13WL PER AMM 33-51-38 AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202311202024Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 12WL INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNIT 12WL PER AMM 33-51-38 AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202311203405Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 11WL INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNIT 11WL PER AMM 33-51-38 AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202311206472Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 10WL INOPERATIVE. REPLACED EMERGENCY POWER SUPPLY UNIT 10WL PER AMM 33-51-38 AND A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR WX0A1900010031903Unknown · unknown(MAJOR REPAIR) CORROSION FOUND ON BULK CARGO LOWER SILL BEAM FASTENER HOLES / ON BULK CARGO LOWER SILL BEAM, FASTENERS HOLES PERMANENTLY REPAIRED AS PER SRM 53-41-49-300-003 REV. 146, REPAIR CATEGORY B, WITH REPEAT INSPECTION REQUIREMENT LISTED SRI53-41-49-205SDR AALA202311208483Handle · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK LEFT HAND SLIDING WINDOW HANDLE CRACKED. REPLACED HANDLE PER CMM 56-12-12.SDR SOKF2023F00339Unknown · unknownDURING THE CLIMB OF AIRCRAFT N689TA ON FLIGHT AV632 ON NOV 15, 2023 ROUTE FROM SJO TO MEX, IT RETURNED TO SJO DUE TO SUSPICION OF POSSIBLE BIRD STRIKE OR DRONE IMPACT ON THE AIRCRAFT, AS INDICATED BY THE CAPTAIN IN THE LOGBOOK. NO OVERWEIGHT LANDING IS PRESENTSDR ANCF20231411034Control Unit · faultedBRAKES ALTN L RELEASED. INOP SYS ALTN L BRK. IAW TSM TASK 32-43-00-810-824-A REV.66 / DATE 01-NOV-2023, RESET OF BSCU WAS PERFROMED SATISFACTORILY. APTLSDR AALA202311202962Skin Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING TOP SKIN PANEL TRAILING EDGE LOWER SURFACE AT RIB 14. REPAIRED SKIN PANEL PER EA 347929.SDR AALA202311201981Skin Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING TOP SKIN PANEL TRAILING EDGE LOWER SURFACE AT RIB 7. REPAIRED SKIN PANEL PER EA 347929.SDR AALA202311206161Skin Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING TOP SKIN PANEL TRAILING EDGE UPPER SURFACE BETWEEN RIBS 14 AND 15. REPAIRED SKIN PANEL PER EA 347929.SDR 2023F00329Control Unit · inoperativeAFTER TAKE OFF, LGCIU 2 FAULT INDICATION WAS SHOWN. ATB PROCUEDURE TO BOGOTA STATION DUE TO BY MEL MANUAL, BOTH REVERSIBLES SHOULD BE OPERATIVE TO APROACH IN SANTA MARTA STATION// AS PER TSM 32-31-00-810-819-A FAULT INSOLATION LGCIU 2 WAS REMOVED AND REPLACEDSDR AALA202311157509Battery · no testAIRCRAFT WAS GROUNDED: EMERGENCY POWER SUPPLY UNIT 13WL FAULT DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 13WL (AALA202311158595) AND BATTERY (AALA202311157509) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISSDR AALA202311158595Power Supply · no testAIRCRAFT WAS GROUNDED: EMERGENCY POWER SUPPLY UNIT 13WL FAULT DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 13WL (AALA202311158595) AND BATTERY (AALA202311157509) PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISSDR AALA202311145791Stop Fitting · out of adjustAIRCRAFT IN BASE MAINTENANCE: FLIGHT CREW REPORTED THAT DURING THE POST CHECK FUNCTIONAL CHECK FLIGHT THE R1 DOOR HAS VIBRATION AT THE TOP FORWARD AREA THAT BEGINS AT 21500 AND CONTINUES TO CRUISE. MAINTENANCE ADJUSTED THE R1 DOOR STOPS PER AMM 52-11-00-820-00SDR WX0A1900010031893Unknown · unknown(MAJOR REPAIR) R/H ELEVATOR, OUTBOARD SERVO ATTACH FITTING, ANTI-ROTATION LUG GOUGED / RH ELEVATOR OUTBOARD SERVO ATTACH FITTING ANTI-ROTATION LUG AREA PERMANENTLY REPAIRED PERFORMED AS PER SRM 55-26-47-300-001 REV 146. REPAIR CLASSIFIED MAJOR CATEGORY A WITH SDR AALA202311145295Damper · low pressureAIRCRAFT IN BASE MAINTENANCE: AFT RIGHT DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. MAINTENANCE SERVICED DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202311200500Skin Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING TOP SKIN PANEL TRAILING EDGE UPPER SURFACE AT RIB 24. REPAIRED SKIN PANEL PER EA 347929.SDR AALA202311133071Damper · no testAIRCRAFT IN BASE MAINTENANCE: PASSEMGER / CREW DOOR 842 DAMPER AND EMERGENCY OPERATION CYLINDER FAILED THE DAMPING FUNCTIONAL CHECK. REPLACED DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-13-14. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR WX0A2023111331889Epsu · unknownFWD, EMERGENCY EXIT ROW LEFT AND RIGHT, AND AFT EPSU BATTERIES REQUIRE REPLACING / REMOVED AND REPLACED FWD EPSU BATTERY, EMERGENCY EXIT ROW LEFT AND RIGHT EPSU BATTERIES, AND AFT EPSU BATTERY IAW AMM 33-51-38-400-001-A"SDR WX0A2023111331888Epsu · unknown10WL EPSU BATTERY PACK FAILED. / REMOVED AND REPLACED 10WL EPSU BATTERY PACK IAW AMM 33-51-38-000-002A AND AMM 33-51-38-400-002A. OPS CHECK GOOD.A.C OK FOR SERVICE."SDR AALA202311137763Life Vest · missingAIRCRAFT WAS NOT GROUNDED: CLEANER REPORTED MISSING LIFE VEST ON SEAT 6F. INSTALLED LIFE VEST AT SEAT 6F AS REQUIRED.SDR AALA202311131201Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND MAIN LANDING GEAR DOOR FORWARD RETRACTION ACTUATOR ATTACHMENT FITTINGS CRACKED. REPLACED MAIN LANDING GEAR DOOR ASSEMBLY WHICH CONTAINED NEW FITINGS INSTALLED PER AMM 32-12-11.SDR ASAA2023110946850Stringer · corrodedLH STR 32L BETWEEN FR63 AND FR62 HAS SEVERAL SPOTS OF CORROSION GROUNDED - YES. EVALUATED CORROSION ON S32L AT FR 62-FR 63, ORIGINAL MATERIAL 0.071", REMOVED 0.045",REMAINING MATERIAL 0.026" FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN A320 SRM MAJOSDR ANCF20230911033Lgciu · warning messageLGCIU 2 FAULT AFTER TAKE OFF AS PER TSM 32-31-00-810-819-A FAULT INSOLATION LGCIU 2 WAS REMOVED AND REPLACED TEST OK. DUE TO LGCIU 2 REPLACED AND SOFTWARE CONFIGURATION, THE LGCIU1 WAS REPLACED TEST OKSDR AALA202311134640Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME FASTENER HOLE C AT THE DOUBLE JOGGLE AREA LOCATED AT FR 16 AND S14R. REPAIRED FRAME PER EA 347551.SDR AALA202311101057Wire Harness · inoperativeAIRCRAFT WAS NOT GROUNDED: 20 ABC EMERGENCY LIGHT INOP. REMOVED AND REPLACED SEAT HARNESS.SDR ASAA2023110846851Stringer · corrodedLH STR 36L BETWEEN FR63 AND FR64 HAS SURFACE CORROSION IS SEVERAL SPOTS GROUNDED - YES. LH STR 36L CORRODED. CORROSION FOUND TO BE OUT OF LIMITS. CORROSION REMOVED. RFTS GENERATED AND REPAIR ACCOMPLISHED IAW A320-53EA-01997. ORIGINAL THICKNESS=.080" REMOVED=.0SDR ASAA2023110846614Stringer · corrodedLH STR 30L BETWEEN FR64 AND FR63 HAS SURFACE CORROSION GROUNDED - YES. NO LIMITS FOUND FOR AREA. LOCATED, DRILLED AND DEBURRED MATERIAL DAN50B13P.O. 1074939.1 AND A53986219DAN2001T79511 P.O. 1074961.1 IAW A320 SRM51-44-11 AND A320 SRM 53-00-13. BHFEC OPEN HOSDR AALA202311136427Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD RIGHT HAND FRAMING CENTER POST LOWER ATTACHMENT AT FR 2 AND Y0. REPAIRED FRAME PER EA 347615.SDR AALA202311135487Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD LEFT HAND FRAMING CENTER POST LOWER ATTACHMENT AT FR 2 AND Y0. REPAIRED FRAME PER EA 347615.
Back to Airbus A320-214