Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2018062192706Unknown · odorDETECTED FUMES ON FINAL APPROACH. THE ODOR OF VOMIT AND DIRTY SOCKS THROUGHOUT THE CABIN. CABIN, LAVATORIES, CARPETS AND CARGO BAYS WERE INSPECTED, NO EVIDENCE OF DAMAGE OR LEAKAGE IAW AMM 05-50-00-810-801-A. ENGINES WERE INSPECTED NO EVIDENCE OF LEAKAGE ISDR AALA201806209003Lens · missingEMERGENCY LIGHT LENS MISSING, ROW 1. REPLACED THE LENS.SDR CALA2018062211495Stringer · corrodedDURING INSPECTION OF THE AFT CARGO STRINGER 43L, FOUND CORROSION BETWEEN FRAMES 58 - 59. REMOVED AND REPLACED THE STRINGER IAW SRM 51-42-11-001.SDR GTIA2018062182704Seal · leakingCABIN ODOR OF DIRTY SOCKS OR MUST. PERFORMED TSM 05-50-00-810-831-A. FOUND THE APU TO BE SOURCE OF THE ODOR. COMPLIED WITH DECONTAMINATION OF THE ECS IAW AMM 21-00-00. R & R THE RECIRCULATION FILTERS IAW AMM 21-21-41. NO FURTHER ODOR NOTED AT THIS TIME. SDR YENA201806180252Battery Pack · failedCABIN EMERGENCY LIGHTS FAILED A BITE TEST. REMOVED AND REPLACED THE POWER SUPPLY BATTERIES AT 10WL, 11WL, AND 13WL, IAW AMM 33-51-38. EMERGENCY LIGHTS CHECKED GOOD.SDR YENA201806180251Battery Pack · failedCABIN EMERGENCY LIGHTS FAILED A BITE TEST. REMOVED AND REPLACED THE POWER SUPPLY BATTERIES AT 10WL, 11WL, AND 13WL, IAW AMM 33-51-38. EMERGENCY LIGHTS CHECKED GOOD.SDR YENA201806180250Battery Pack · no testCABIN EMERGENCY LIGHTS FAILED A BITE TEST. REMOVED AND REPLACED THE POWER SUPPLY BATTERIES AT LOCATION FIN 10WL,11WL AND 13WL IAW AMM 33-51-38. EMERGENCY CABIN LIGHTS CHECKED GOOD.SDR CALA2018062211489Profile · crackedRIGHT AFT EMERGENCY EXIT HATCH WAS CRACKED, FOUND ON BOTH LT & RT LOAD TRANSMITTING PROFILES. REMOVED AND REPLACED IAW SRM 51-72-11-911-001.SDR CALA2018062901528Feeder Cable · meltedNR 2 ENGINE UPPER FWD PYLON ATTACH SHACKLE FEEDER WIRE ARRAY BUNDLE IN CONTACT WITH SHACKLE, MELTED THREE WIRES . REPAIRED IAW ECRA 57620-03014.SDR YENA201806186254Connector · looseLEFT WINDSCREEN EMERGENCY LIGHT INOPERATIVE. SECURED A LOOSE CONNECTOR IAW 33-50-00. OPS OK.SDR YENA2018061860253Connector · looseROW 1 ABC SEAT MOUNTED EMERGENCY LIGHT WAS INOPERATIVE. SECURED A LOOSE CONNECTOR IAW 33-50-00, OPS OK.SDR AALA2018061989012Wire · brokenROW 22L EMERGENCY LIGHTS INOPERATIVE. TERMINATED THE WIRES ON THE CIRCUIT PANEL. SYSTEMS OPS CHECKED GOOD IAW AMM 33-51-00-710-001A.SDR YENA2018061850257Lens · missingEMERGENCY LIGHT LENS MISSING. INSTALLED THE LENS IAW AMM 25-65-00.SDR YENA201806185255Power Supply · failedPOWER SUPPLY 10WL FAULTED. REMOVED & REPLACED THE POWER SUPPLY IAW AMM 33-51-38.SDR AALA201806159004Entertain Sys · malfunctionedTHE AIRCRAFT WAS GROUNDED. FLIGHT ATTENDANT REPORTED ELECTRIC SMELL AT ROW 19 WITH HUMMING SOUND. FOUND NO ODOR FROM ENGINES OR APU. FOUND ACRID ODOR COMING FROM WIRELESS ENTERTAINMENT IN CEILING PER J/C 26L00021001. REPLACED KANDU (UNIT, KU BAND) PER LAPTOP. SDR YENA2018061840256Fan · failedSTRONG BURNING ELECTRICAL ODOR REPORTED NEAR ROWS 1, 2, & 3. ODOR STOPPED AND DISSIPATED QUICKLY. PERFORMED A CABIN ODOR INSPECTION IAW AMM 05-50-810-831-A. FOUND THE AVIONICS BLOWER FAN TO BE SOURCE OF THE ODOR. R & R THE BLOWER FAN. RESET THE CIRCUIT BRSDR YENA201806140247Wire Harness · damagedROW 13C SEAT MOUNTED EMERGENCY LIGHT WAS INOPERATIVE. FOUND THE HARNESS UNDER THE SEAT DAMAGED. R & R THE WIRE HARNESS AND OPS TESTED GOOD IAW AMM 33-51-19.SDR GTIA2018061402697Bottle · low pressureR1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00SDR CALA2018062101471Door Sill · corroded(A3NB-53-3-6222) L2 DOOR SILL IS CORRODED IN MULTIPLE SPOTS BETW EEN FR66 AND FR68. REFER TO AAR N/R: 9607599. CLEANED SEALANT AND DINOL/PAINT DEBRIS FROM (2EA) AFT GIRT BAR P LATE FASTNOR HEADS PER A320 SRM'S 51-78-00-001 AND 51-74-00-001 1.D. NO CORROSION FSDR CALA2018062101473Cover Plate · crackedL1 DOOR COVER PLATE CRACKED ON UPPER RIGHT CORNER. REMOVED AND REPLACED L1 DOOR UPPER COVER PLATE IAW SRM 5 1-42-11. INSTALLED NEW RUB STRIPS IAW AMM 52-11-18-300-002-A.SDR CALA2018062101472Stringer · corrodedCORROSION FOUND ON STRINGER 41R, BETWEEN FRAMES 26 AND 27 IN THE CARGO BILGE AREA UNDER ENTRANCE CAVITY. REMOVED THE CORROSION AND PERFORMED REPAIR ON THE STRINGER IAW 240518-4655-2501782-08, AND EC/RA 5311-01955.SDR YENA201806143248Lens · detachedEXIT ROW EMERGENCY LIGHT AT 1C, LENS DETACHED. SECURED THE LENS IAW AMM 33-51-19.SDR YENA201806143246Control Unit · failedAT 18,000 FT, ECAM DATALINK ATSU FAULT WITH STRONG ELECTRICAL ODOR IN THE COCKPIT. PULLED CIRCUIT BREAKERS L-15 & 16 AND THE ODOR DISSIPATED SLOWLY. ACCOMPLISHED TSM 24-00-00-810-803-A, IDENTIFIED ATSU COMPUTER TO HAVE THE BURNING ODOR INTERNALLY. NO DEFESDR YENA2018100820526Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y-765 FR66 STR 23R; REMOVED AND REPLACED FLOORBEAM Y-765 FR66 STR23R IAW SRM 53-00-14-283-002, 53-41-15 FIG 001 WORK ACCOMPLISHED PER SERVICE ORDER NUMBER 440484-26658SDR YENA2018100820525Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE RT WEB PANEL AT FR20; BLENDED FOUND MATERIAL LOSS OUT OF LIMITS REMOVED AND REPLACED CABIN FLOOR STRUCTURE RT WEB PANEL AT FR20 STR 23 IAW SRM 51-42-11 PAE2 AND 51-74-00 WORK ACCOMPLISSDR YENA2018100820524Seat Track · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y-254 FR 18 +6" STR 23R; REMOVED CORROSION ON CABIN SEAT TRACK Y-254 FR 18 +6 STR 23R VERIFIED BEYOND LIMITS REMOVED AND REPLACED IAW SRM 53-11-14-283-004 AND 51-72-11. WORKSDR YENA2018100820523Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE FLOORBEAM Y1292 FR 68 STR 23L; REMOVED CORROSION ON CABIN FLOORBEAM Y1292 FR 68 STR 23L VERIFIED BEYOND LIMITS REMOVED AND REPLACED IAW SRM 53-00-14-283-002 AND 51-72-11. ALL WORK ACCOSDR YENA2018100820522Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 PAX DOOR SILL FR 66 STR 23R OB SIDE 2EA HASTENER HOLES; R2 DOOR SILL OUT OF LIMITS IAW SRM 53-41-14-213-002, REMOVED AND REPLACED R2 SILL IAW 51-72-11, 51-42-11, AND 53-41-14 FIG 021. ALL WORK ACCOMPLISHSDR YENA2018100820521Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765B FLOORBEAM FRAME 66 STR 23L; REMOVED AND REPLACED AFT CABIN Y765 FLOORBEAM FRAME 66 STR 23L IAW SRM 51-42-11 PARA D. ALL WORK ACCOMPLISHED UNDER NR 440484/26665SDR YENA2018100820520Seat Track · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y1292 FR 20 STR 23R; REMOVED CORROSION ON CABIN SEAT TRACK Y1292 FR 20STR 23R VERIFIED BEYOND LIMITS REMOVED AND REPLACED IAW SRM 53-11-14-283-004 AND 51-72-11. ALL WORK ACCSDR YENA2018100820519Seat Track · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE SEAT TRACK Y765 FR 16 STR 23L; REMOVED CORROSION ON CABIN SEAT TRACK Y765 FR 16 STR 23L VERIFIED BEYOND LIMITS. REMOVED AND REPLACED IAW SRM 53-11-14-283-004 AND 51-72-11. ALL WORK ACCSDR YENA2018100820518Dummy Rail · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN DUMMY RAIL O/O OF Y254 FRAME 66 STR 23R; REMOVED CORROSION ON AFT CABIN DUMMY RAIL O/B Y254 FRAME 66 STR23R, VERIFIED BEYOND LIMITS, REMOVED AND REPLACED IAW SRM 53-00-14-283-002 AND 51-72-11. ALLSDR YENA2018100820517Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y464 FLOORBEAM FRAME 68 STR 23R; REMOVED AND REPLACED AFT CABIN FLOORBEAM FRAME 68 STR 23R IAW SRM 51-72-11/51-74-00 STEP 3. ALL WORK ACCOMPLISHED ON NR 440484/26661SDR YENA2018100820516Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765 FLOORBEAM FRAME 68 STR 23L; REMOVED AND REPLACED AFT CABIN Y765 FLOORBEAM FRAME 68 STR 23L IAW SRM 51-72-11/51-42-11. ALL WORLK ACCOMPLISHED ON NR 440484/26666/902984SDR YENA2018100820515Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y765 FLOORBEAM FRAME 68 STR 23R; REMOVED AND REPLACED AFT CABIN FLOORBEAM Y765 FR68 STR 23R IAW SRM 53-00-14-283-002, 53-41-14 FIG001. ALL WORK ACCOMPLISHED UNDER NR 440484/26660/902984SDR YENA2018100820514Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN Y464 FLOORBEAM FRAME 64+11 STR 23L; REMOVED AND REPLACED AFT CABIN Y464 FLOORBEAM IAW SRM 51-42-11/51-72-11 AT FR64+11 THRU 68+6 STR23L. ALL WORK ACCOMPLISHED ON NR 444484/26664/902984SDR YENA2018100820513Dummy Rail · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON CABIN FLOOR STRUCTURE DUMMY RAIL Y-189 AT FR20+3; REMOVED AND REPLACED DUMMY RAIL AT Y189 FR20=3 IAW 51-42-11/51-74-00, ALL WORK ACCOMPLISHED UNDER NR 440484/26701SDR YENA2018100820512Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BULK DOOR SILL FRAME 62 STR 38R; REMOVED CORROSION ON BULK CARGO DOOR FR 62 STR 38R VERIFIED BEYOND LIMITS IAW SRM 53-41-49-283-001 BULK SILL REPLACED ON NR 440484-26590. WORK ACCOMPLISHED PER PRODUCTION NUSDR YENA2018100820511Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN -Y1292 FLOORBEAM FRAME 68 STR 23R; BLENDED AND CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14-283-002 FIG 001 REMOVED AND REPLACED IAW SRM 51-42-11 AT AFT CABIN -Y1292 FLOORBEAM FRAME SDR YENA2018100820510Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN - Y1292 FLOORBEAM FRAME 68 STR 23R; BLENDED AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14-283-002 FIG 001, REMOVED AND REPLACED IAW A320 SRM 51-42-11 AT AFT CABIN - Y1292 FLOORBEAMSDR YENA2018100820509Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 DOOR SILL FR 66NSTRN23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 PAX DOOR SILL FR 66 STR 23R VERIFIED BEYOND LIMITS IAW SRM 53-41-14-283-002 R2 DOOR SILL REPLACED ON NR 440484/26654. ALL WORK ACCSDR YENA2018100820508Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 DOOR SILL FR 66NSTRN23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 PAX DOOR SILL FR 66 STR 23R VERIFIED BEYOND LIMITS IAW SRM 53-41-14-283-002-R2 DOOR SILL REPLACED ON NR 440484/26654. ALL WORK ACCSDR YENA2018100820507Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON R2 PAX DOOR SILL FR 66 STR 23R HAS 3 EA FASTENER HOLES; REMOVED CORROSION ON R2 DOOR SILL FR 66 STR 23R VERIFIED BEYOND LIMITS IAW SRM 53-41-14-283-002 R2 DOOR SILL REPLACED ON NR 440484/26654. ALL WORK ACCSDR YENA2018100820506Door Sill · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON L2 PAX DOOR SILL FR 68 STR 23L HAS 4 EA FITTING HOLES; REMOVED CORROSION L2 PAX DOOR SILL FR 68 STR 23L VERIFIED BEYOND LIMITS IAW SRM 53-41-14-283-002 REMOVED AND REPLACED L2 DOOR SILL IAW A320 SRM 53-41-1SDR CALA2018062101469Frame · crackedA CRACK INDICATION DURING ROTO PROBE AT FRAME 35, STRINGER 30L, ACCOMPLISHED A PERMANENT REPAIR IAW ECRA 5331-02230, PART 3.SDR CALA2018062101468Slide · delaminatedLEFT OVERWING SLIDE HAS COMPOSITE DELAMINATION ON FWD EDGE. REMOVED AND REPLACED THE SLIDE.SDR CALA2018062101467Lens · missingLAVATORY D, AFT EMERGENCY LIGHT LENS WAS MISSING, REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33 -51-19-000-002-A, AND 33-51-19-400-002-A. PERFORMED CHECK OF CABIN LIGHTS AND SIGNS IAW AMM 33-51-00-710-009-A. NO DEFECTS NOTED.SDR CALA2018062101466Stringer · corrodedCORROSION FOUND ON STRINGER BETWEEN FR 31-32. REPAIRED, HFEC,ROTOPROBE , UT AND RESTORED IAW SRM 21-74-00-001, AND SRM 53-21-13-300-002.SDR AALA201806209001Bolt · wornACTUATOR BOLT FOUND WORN ON THE NR 4 SPOILER. REPLACED THE STOP BOLT IAW SRM 57-70-00.SDR YENA2018061420244Hinge · damagedDURING HEAVY MAINTENANCE, THE NR 3 RUDDER HINGE HAD ONE ELONGATED HOLE. REPLACED THE RUDDER HINGE IAW SRM 51-42-11, 51-72-12, 51-44-11, AND 55-36-42.
Back to Airbus A320-232