Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201705109024Pin · crackedCRACK IN LEFT MAIN LANDING GEAR REAR PINTLE PIN. REPLACED THE PINTLE PIN.SDR GTIA2017041401873Oxygen Mask · damagedCAPTAIN`S OXYGEN MASK HOSE TO MASK APPEARS BROKEN, IT LEAKS OXYGEN WHEN HOSE IS MOVED AROUND AND IS NOT SEATED FULLY TO AGAINST THE MASK. R & R THE OBSERVER OXYGNE MASK IAW AMM 35-12-41. LEAK CHECKED GOOD. OPS CHECKED GOOD.SDR CALA2017041400984Unknown · smokeBEHIND FIRST CLASS SEATS 3AB. A PUFF OF SMOKE NOTED IN CABIN VISUALLY WITH ELECT SMELL PERFORMED FORM 46-6020 AND INSPECTION AND CHECK IAW 05-51-10-200 -801C1. INSPECTED AREA AND FOUND NO ELECTRICAL ISSUES WITH ANY OF THE SEAT ELEC UNITS. CHECK ALL CONNECTIONSDR CALA2017041400971Strut · faultyFLAPS LOCKED - ALIGNMENT FAULT DISPLAYED ON UPPER ECAM SCREEN. EMERGENCY DECLARED. REF LOG PG 4359813 LINK ASSY BUSHING RR, REF LOG PG 4359903 RT I /B AND O/B ROLLERS RR, REF LOG PG 4359750 LT I/B O/B ROLLERS RR, REF LOG 4360620 LT INTERCONNECTING STRUT RR, RESDR CALA2017041400990Cover · looseL FWD EMERG COVER FELL OFF AGAIN. REMOVED LT EMERGENCY EXIT HATCH COVER FLAP IAW AMM 52 -21-11-000-001-A. REINSTALLED LT EMERGENCY EXIT HATCH COVER FLAP IAW AMM PERFORMED PULL TEST IN LT EMERGENCY EXIT HATCH COVER FLAP IAW AMM 52-21-11-400-001-A PULL TEST GOODSDR CALA2017041400986Cover · missingROW 20ABC EXIT COVER ON SIDEWALL IS MISSING. REPLACED THE COVER AND BULBS. SIGN SECURED AND LIGHT CHECKS NORMAL.SDR CALA2017041400992Battery · inoperativeFLT DECK EMER FLASHLIGHT NOT BLINKING. REPLACED BATTERY IN EMER FLASHLIGHT @ FLT DECK AND APPLIED NEW SEAL. OPS GOOD.SDR CALA2017041400991Flashlight · unsecureAFT CABIN FLASHLIGHT AFT CABIN WAS PULLED OUT OF HOLDER. INDICATOR LIGHT NOT FLASHING REPLACED BATTERY AT AFT OTBD EMER FLASHLIGHT AND RESEALED. OPS GOOD.SDR AALA201704199003Floor Panel · delaminatedDELAMINATED RIGHT SIDE SLOPING FLOOR PANEL 132FF IN FORWARD CARGO BAY. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701, REVISION G.SDR YENA201704120284Power Supply · no testDURING THE PERFORMANCE OF AN OPS CHECK FOR THE EMERGENCY LIGHTS, THE FWD LT EPSU FAILED. TRIED NUMEROUS TIMES TO RESET FAULT STILL PRESENT. R & R THE EPSU & BATTERY IAW AMM 33-51-38. OPS CHECKED GOOD IAW AMM.SDR AALA201704139012Connector · disconnectedEMERGENCY LIGHT AT SEAT ROW 11ABC INOPERATIVE. FOUND CONNECTOR IN SEAT DISCONNECTED, RECONNECTED IN SEAT CONNECTOR.SDR CALA2017041000951Director · malfunctionedEMERGENCY EXIT LIGHTS COME ON. RESET CIDS 2 DIRECTOR EMERGENCY LIGHTS. OPS CHECK GOOD REF MM 33-51-00.SDR CALA2017041000944Fitting · crackedREMOVED CRACKED CROSSBEAM CONNECTING FITTING. REMOVED CRACKED CROSS BEAM CONNECTING FITTING IAW SRM 51-72 -11. REPLACED FR68 CROSSBEAM CONNECTING FITTING WITH NEW PART IAW SRM 51-72-11.SDR CALA2017041000943Skin · dentedDENT NOTED ON LOWER FUSELAGE 2" AFT OF FR24 BETWEEN STR 41L AND STR 42L. DENT MEASURES 7.5"L X 4.5"W X 0.425"D. FABRICATED REPAIR DOUBLER/FILLER, ALODINED AND PRIMED. INSTALLED REPAIR IAW 5854 REV B STEP 9. REPAIR WAS ACCOMPLISHER PER ECRA 5321-01943.SDR YENA201704100251Power Supply · failedDURING ROUTINE MAINTENANCE, EMERGENCY LIGHTS AT ROWS 15, 19, & 23 INOPERATIVE. R & R THE POWER SUPPLY IAW AMM 33-51-38. OPS CHECKED GOOD.SDR CALA2017040800925Plate · corrodedCORROSION AT LAV E XHAUST VENT OUTLET CUTOUT. REMOVED CORRODED LAV EXHAUST VENT OUTTER REINFORCEMENT PLATE IAW SRM 51-72-11. INSTALLED NEW LAV EXHAUST VENT OUTLET REINFOR CEMENT PLATE IAW SRM 51-72-11.SDR AALA201705119029Floor Panel · brokenBROKEN FLOOR PANEL 151GF IN AFT CARGO BAY. REPLACED THE FLOOR PANEL IAW SRM A320 53-02-00 AND IRM 9701 REVISION G.SDR CALA2017040700907Battery · dischargedEMERGENCY EXIT DOOR LIGHT BATTERIES FAILED CAPACITANCE TEST AT FWD AND AFT POSITIONS REF JC JE18-2428-1-6192. CHANGE EMERGENCY EXIT DOOR LIGHT BATTERIES AT LOCATION FWD AND AFT REF AMM 33-51-38. TEST PASSED.SDR CALA2017040700906Connector · unsecureDURING THE PAX DOOR ESCAPE RELEASE OPS CHECK, FOUND THE L2 DOOR SLIDE ARM LIGHT ON WHILE HANDLE IN UNARMED. DISCOVERED A CONNECTOR IMPROPERLY CONNECTED. CONNECTED THE CONNECTOR PROPERLY IAW AMM 52-13-00-710-001.SDR CALA2017040700905Switch · brokenFT ATTENDANTS PANEL EMERGENCY LIGHT SWITCH IS BROKEN . REMOVED AND REPLACED THE PANEL IAW AMM 23-73-13-000- 001-A, AND AMM 23-73-13-400-001-A, OP TESTED GOOD IAW AMM 23 -73-00-740-005-A.SDR CALA2017040700904Strap · looseR2 DOOR DISARMED IN FLIGHT, HANDLE POPPED OUT OF ARMED POSITION. FOUND TH SLIDE COVER LOWER STRAPS LOOSE AND HANGING DOWN UNDER THE GIRT BAR, SECURED THE STRAPS. PERFORMED AMM 52-10-00-860-001-A, AMM 52-10-00-720-005-A, AND AMM 52-73-00-710-001-A, OPS CHECSDR CALA2017040700868Door Sill · corrodedAFT CARGO DOOR INBD SILL CORRODED, FRAMES 53 - 56. REMOVED AND REPLACED THE CARGO DOOR SILL IAW SRM 51-42-11, PG 9, & SRM 51-72-11.SDR YENA201704070246Battery Pack · no testDURING ROUTINE MAINTENANCE, EMERGENCY LIGHTS FAILED TO TEST. R & R THE EPSU BATTERY AT 10WL,11WL,AND 13WL. CHECKED GOOD IAW AMM 33-51-38.SDR YENA201704070245Battery Pack · no testDURING ROUTINE MAINTENANCE, EMERGENCY LIGHTS FAILED TO TEST. R & R THE EPSU BATTERY AT 10WL,11WL,AND 13WL. CHECKED GOOD IAW AMM 33-51-38.SDR YENA201704070244Battery Pack · no testDURING ROUTINE MAINTENANCE, EMERGENCY LIGHTS FAILED TO TEST. R & R EPSU BATTERY AT 10WL,11WL,AND 13WL CHECKED GOOD IAW AMM 33-51-38.SDR GTIA2017040601866A/C Pack · odorRA REPORTED ODOR IN AFT CABIN DURING CLIMB WENT AWAY AFTER 5 MIN. ODOR RETURNED ON DESCENT APPROACH. TURNED OFF PACK 1 ODOR WENT AWAY. PERFORMED PACK 1 BURNOUT IAW AMM 21-00-00-615-002-A.NO NOTED DEFECTS. THIS CLEARS DMI 2177810-1. PLACARD REMOVED.SDR GTIA2017040601865Unknown · odorCREW REPORTED ODOR EVENT IN CABIN & COCKPIT ON DECENT. PERFORMED LEAK TEST OF NR 1 & NR 2 ENG IAW AMM 71-00-00. NO LEAKS NOTED, NO SMELL NOTED ON EITHER BLEED 1 BLEED 2 OR PACK 1 OR 2. PERFORMED INSPECTION OF APU IAW AMM 49-11-11. NO LEAKS NOTED (REF TSM 21-0SDR YENA201704060248Battery Pack · failedDURING PRE DEPARTURE CHECKLIST, FOUND EMERGENCY LIGHTS INOPERATIVE AT OVERWING EXIT ROW SEATS. REMOVED & REPLACED ESPU & BATTERY AT 13WL.SDR YENA201704060247Power Supply · failedPRE DEPARTURE CHECKLIST FOUND EMERGENCY LIGHTS INOPERATIVE AT THE OVERWING EXIT ROWS, & SEATS. REMOVED & REPLACED THE ESPU & BATTERY AT 13WL & 12WL.SDR CALA2017040700887Frame · corrodedAFT CARGO BAY AT FRAME 58 BETWEEN STRINGERS 42 - 43L HAS CORROSION. REPAIRED IAW SRM 51-72-11, PARA 5.A.SDR AALA201704069018Thermocouple · faultyAIRCRAFT WAS GROUNDED. ON DESCENT ENGINE 1 IDLE AT 41 % FF 1200 ENGINE 2 IDLE 28 % FF 700. REMOVED & REPLACED NR 1 ENGINE FUEL TEMP SENSOR.SDR YENA201704040249Engine · leakingDURING DESCENT AND CLIMB,STRONG ODOR, INDICATING OIL IN THE AIR CON DUCT. R & R THE NR 1 ENGINE . ALL CHECKED GOOD AND NO ODOR.SDR CALA2017040700885Stringer · corrodedSTRINGER 31R, 6 INCHES FORWARD OF FRAME 66, BELOW THE OUTFLOW VALVE, FOUND CORRODED. REMOVED AND REPLACED THE STRINGER IAW SRM 51- 44-11, TABLES 3 AND 5, 51-42-11 PARA 6 AND 7.SDR YENA201704040243Filter · odorODOR DURING DESCENT FROM PACKS, STRONGER ODOR WITH APU BLEED. R & R THE NR 1 & 2 PACKS OZONE FILTERS IAW AMM 21-51-41. PERFORMED HIGH POWER RUN ASSURANCE CHECK, ISOLATED PACKS, NO ODOR PRESENT. OK FOR SERVICE.SDR YENA201704040242Filter · odorODOR DURING DESCENT FROM PACKS, STRONGER ODOR WITH APU BLEED. R & R THE NR 1 & 2 PACKS OZONE FILTERS IAW AMM 21-51-41. PERFORMED HIGH POWER RUN ASSURANCE CHECK, ISOLATED PACKS, NO ODOR PRESENT. OK FOR SERVICE.SDR CALA2017040400851Power Supply · faultyFOUND CABIN EEL LIGHTS INOP DURING 2 SERVICE CHECK. REPLACED 1 EACH POWER SUPPLY AND 4 EA BATTERIES.SDR CALA2017040400849Battery · faultyBATTERY EMER R FAULT APPEARED ON CIDS PANEL AFTER PERFORMING EMERGENCY LIGHTS TEST. REPLACED BATTERY EMER R. OPS CHECKS GOOD. REF AMM 33-51-38.SDR CALA2017040400807Coffeemaker · inoperativeFA REPORTS FWD COFFEEMAKER INOP. NO CB POP BUT REPORTED POSSIBLE ELEC SMELL PRIOR . REPLACED COFFEEMAKER.SDR CALA2017040400806Oven · inoperativeGALLEY OVEN INOP AT R42 OVEN R42 IN AFT GALLEY TRIPPED BREAKER R42. PLASTIC BURN SMELL ASSOC BUT DISSIPATED. REPLACED R42 GALLEY OVEN, OPS CHK GOOD.SDR AALA201704059031Packing · leakingODOR REPORTED BY FLIGHT ATTENDANT IN CABIN. FOUND CAUSE TO BE APU OIL LEAK. REMOVED AND REPLACED APU NR 4 CAVITY VENT TUBE PACKINGS. CHECKED GOOD.SDR AALA201704049009Pump · inoperativeCENTER FUEL PUMP NR 1 INOPERATIVE. REMOVED AND REPLACED THE NR 1 FUEL PUMP.SDR GTIA2017040201856Apu · malfunctionedDIRTY SOCK SMELL DURING T/O AND DURING DECENT. REMOVED AND REPLACED APU IAW AMM 49-11-11.SDR AALA201704039004Power Supply · inoperativeEMERGENCY LIGHT EPSU AFT LEFT INOPERATIVE. REPLACED THE EPSU.SDR AALA201704039003Cover · brokenEMERGENCY LIGHT COVER BROKEN. REPLACED THE COVER.SDR YENA201704020238Battery Pack · no testDURING AN EMERGENCY LIGHT TEST, THE EPSU BATTERIES FOR FWD AND AFT, FAULTED. R & R THE FWD AND AFT EPSU BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD.SDR YENA201704020237Battery Pack · no testDURING EMERGENCY LIGHT TEST, THE EPSU BATTERIES FOR FWD AND AFT, FAULTED. R & R FWD AND AFT EPSU BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD.SDR YENA201704020235Skin · corrodedDURING HEAVY CHECK, CORROSION WAS DISCOVERED ON UPPER SKIN OF THE RIGHT WING RIB 12 & 16.5, STRINGER 11. THE SKIN WAS BLENDED IAW SRM 51-74-00, AND EC A17-284-01. MAJOR REPAIR.SDR YENA201704020234Battery Pack · no testDURING A HEAVY CHECK, AFT CABIN EMERGENCY LIGHTS FAILED TO ILLUMINATE WITH THE SWITCH IN ARM AND THE 1WEL AND 2WL CIRCUIT BREAKERS PULLED. R & R THE BATTERY PACK 13WL IAW AMM 33-51-38-000-002-A, AND 33-51-38-400-002-A. OPS CHECKED GOOD IAW AMM 33-51-00-710-0SDR YENA201704020233Skin · dentedDURING HEAVY CHECK, A DENT WAS DISCOVERED ON FUSELAGE SKIN AT FRAME 69+15, STRINGER 20R. CUTOUT THE DAMAGED AREA AND FABRICATED A REPAIR DOUBLER AND INSTALLED IAW SRM 53-41-11-300-018.SDR GTIA2017040101854Unknown · odorOUT OF ABOUT FL 180 HAD A VOMIT OR DIRTY SOCK SMELL AFT AND FWD ABOUT 30 SECS AND THEN WENT AWAY. AFTER PULLING TO THE GATE AND SHUTDOWN ALL WAS NORMAL PERFORMED TSM 71-00-00-810-801-A. NO SMELL OR ODOR NOTED. COULD NOT DUPLICATE AT THIS TIME. A/C OK FOR SERVI
Back to Airbus A320-232