Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA201703160194Beam · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS DISCOVERED THAT L2 DOOR BEAM HAD CORROSION. R & R THE BEAM IAW SRM 51-42-11.SDR YENA201703160193Beam · corrodedDURING HEAVY CHECK MAINTENANCE, DISCOVERED THAT AT R2 DOOR BEAM CORRODED FWD SIDE. Y-1292 BETWEEN FRAMES 65-66. R & R THE BEAM IAW SRM 51-42-11.SDR YENA201703160192Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, THERE WAS EVIIDENCE OF CORROSION UNDER DOOR SILL PLATE CENTER SECTION OTBD BETWEEN THRESHOLD AND R2 DOOR SILL. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14. REMOVED AND REPLACED THE DOOR SILL IAW SRM 51-72SDR YENA201703160191Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON INBD SIDE OF OF THE FLOORBEAM AT Y1292 AT FRAME 15. REMOVED AND REPLACED THE FLOORBEAM.SDR YENA201703160190Plate · corrodedDURING HEAVY CHECK MAINTENANCE, THE L2 DOOR AFT WEB PLATE BETWEEN FRAME 69 - 70 WAS SEVERELY CORRODED. REMOVED AND REPLACED WEB PLATE IAW SRM 51-42-11 PARA I.SDR GTIA2017031501836Unknown · odorON DESCENT AND AFTER LANDING FLIGHT ATTENDANTS AND PASSENGERS REPORTED A FOUL ODOR IN THE CABIN, THAT OF A WET DOG, GYM SOCK. IDENTIFICATION OF CAUSE OF CABIN ODORS OR SMOKE WAS PERFORMED IAW TSM 05-50-00-810-831 INSPECTION OF THE ENGINE 2 NO FOUND DAMAGE OR LSDR GTIA2017031501833Cap Seal · damagedSWEATY SOCK SMELL ON DESCENT AT 5000'. COCKPIT/FWD CABIN HAD THE SMELL. PACK 1 ISOLATED THE SMELL PER OPS BULLETIN PROCEDURE. PER TSM 71-00-00 FOUND ENG NR 1 BLIND CAP SEAL LEAKING. R&R IAW AMM 72-51-41. LEAK CHECK GOOD. DECONTAMINATION OF ENVIRONMENTAL SYSTEMSDR YENA201703150186Wire Harness · failedAFTER GEAR RETRACTION, ECAM BRAKES AUTO BRAKE FAULT BRAKES RELEASED. RETURNED TO DEPARTURE. REMOVED AND REPLACED 2M HARNESS IAW AMM 32-11-43 AND PERFORMED OPS CHECK IAW AMM 32-69-00 AND 32-42-00. ALL FUNCTIONS NORMAL. OPENSDR GTIA2017031401832Harness · leakingFIRST OFFICERS O2 MASK INFLATABLE HARNESS LEAKING. R&R FO O2 MASK IAW AMM 35-12-41. OPS TEST GOOD.SDR GTIA2017031401829Packing · damagedFUME EVENT DURING FINAL DESCENT AND APPROACH INTO PBI 28R. FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED. PERFORMED A CLEANING OF THE ECS TO PACK NR 2 IAW AMM 21-00-00, NO CONTAMINATION FOUND, LEAK CHECK GOOD, OPS CHECK GOOD. PRECAUTIONARY FOUND SDR GTIA2017031401828Unknown · odorFA REPORTED THE SMELL OF SMOKE IN AFT GALLEY WHILE PASSING 11,000 FT DURING LANDING. OPERATED PACK 1 & 2 TO HOT. REMOVED AFT COFFEE MAKER. NO SMELL OF SMOKE OR FOUL ODOR DETECTED. REINSTALLED COFFEE MAKER IAW M/M 21-51-00PB501. NOTED STRONG ODOR EMITTING FSDR AALA201703159001Door Frame · dirtyR2 DOOR SLIDE LEVER VERY DIFFICULT TO ARM AND DISARM. CLEARED DEBRIS FROM UNDER DOOR. ARMS & DISARMS SMOOTHLY. GOOD FOR SERVICE.SDR GTIA2017031401816Unknown · odorFA REPORTED THE AN ODOR OF SMOKE IN AFT GALLEY WHILE PASSING 11,000 FT. DURING LANDING, OPERATED NR 1 & 2 PACKS TO HOT. REMOVED AFT COFFEE MAKER. NO ODOR OF SMOKE OR FOUL ODOR DETECTED. REINSTALLED COFFEE MAKER IAW MM 21-51-00PB501. NOTED STRONG ODOR EMSDR AALA201703149011Lens · missingMISSING EMERGENCY LIGHT LENS 1A, IN PASSENGER CABIN. INSTALLED NEW EMERGENCY LIGHT LENS 1ASDR AALA201703149010Lens · missingMISSING EMERGENCY PATH LIGHT LENS 4A, IN PASSENGER CABIN. INSTALLED NEW EMERGENCY LIGHT LENS 4ASDR AALA201703149009Lens · missingMISSING EMERGENCY LIGHT LENS 24A, IN PASSENGER CABIN. INSTALLED NEW EMERGENCY LIGHT LENS 24A.SDR CALA2017031300586Stringer · corrodedAFT CARGO PIT STRINGER 43LT BETWEEN FR56-59 HAS CORROSION. REMOVED AND REPLACED STR43LT FR54-60 IAW SRM 51-42-11.SDR YENA201703130180Power Supply · failedDURING ROUTINE MAINTENANCE, IT WAS DISCOVERED THAT EMERGENCY LIGHTS WERE OUT AT ROWS 25, 21, 17, AND 3. EMERGENCY EXIT SIGN ABOVE THE R2 DOOR WAS INOPERATIVE. EMERGENCY EXIT SIGN ABOVE THE L2 WAS INOPERATIVE. R2 SIDEWALL EMERGENCY LIGHT WAS INOPERATIVE.REPLACESDR YENA201703130178Bottle · low pressureR1 DOOR SLIDE PRESSURE INDICATION AT RED MARK. R & R THE R1 DOOR SLIDE IAW AMM 25-62-44.SDR GTIA2017031201815Unknown · odorF/A REPORTED A BURNING ELECTRICAL ODOR IN AFT GALLEY. NO ODOR IN CABIN. ODOR CONTINUED IN AFT GALLEY. TURNED NR 2 PACK OFF AND ODOR WENT AWAY. PERFORMED INSPECTION OF THE AFT GALLEY, NO ELECTRICAL DAMGE NOTED, NO SHORT CIRCUITS FOUND OR CIRCUIT BREAKERS TSDR GTIA2017031201814Unknown · odorFLT ATTENDANT REPORTED BURNED RUBBER ODOR IN REAR OF CABIN DURING DECENT. ACCOMPLISHED TSM 05-550-00-810-831-A. ISOLATED PACKS ON APU BLEED AS WELL AS NR 1 AND 2 ENGINE BLEEDS. NO ODOR PRESENT. NO LEAKS FOUND DURING WALK AROUND GVI INSPECTION. INSPECTED ALL LSDR GTIA2017031201813Seal · leakingDURING DESCENT, IDLE THRUST OUT OF 9000 FT, A DIRTY SOCK OR MUSTY ODOR MOSTLY IN CABIN AND AFT CABIN. FOUND AN OIL LEAK AT THE NR 1 ENGINE DEOILER SEAL. REPLACED THE NR 1 AND 2 ENGINES DEOILER SEALS.SDR GTIA2017031201812Unknown · fumesCABIN FUMES NOTED DURING FINAL APPROACH. CYCLED BOTH NR 1 AND 2 ENGINE, RAN NR 1 PACK, THEN NR 2 ON SINGLE OPERATION. NO ISSUES NOTED AT THIS TIME IAW TSM 05-50-00-810-831-A, CYCLED BLEEDS FROM NR 1 ENGINE THEN NR 2SDR CALA2017031300585Stringer · corrodedAFT CARGO PIT STR 42LT BETWEEN FR56-FR59 HAS CORROSION. REMOVED AND REPLACED STRINGER 42LT FR53-60 IAW SRM 51-42-11.SDR CALA2017031200583Stringer · corrodedAFT CARGO PIT STRINGER 31RT AT FR65 HAS EXFOLIATED CORROSION. REMOVED AND REPLACED STRINGER 31RT AT FRAMES 64-67 IAW SRM 51-42-11SDR CALA2017031200582Bracket · damagedUPON REMOVAL OF CLIP AT FR65 BETWEEN STR 31-32 FOUND TWO EACH OUT OF ROUND HOLES REMOVED & REPLACED CLIP ON AFT CARGO FR65 STR 31-32R IAW SRM 51-42-11 P 25 PARA 7.SDR YENA201703120179Pin · malfunctionedAIRCRAFT LEFT EMERGENCY EXIT LIGHT NOT ARMED. SLIDE INDICATION MISSING ON ECAM DOOR PAGE. SLIDE INDICATION ON ECAM, OVERWING EXIT NOT ARMED. FOUND THE LT FWD EMERGENCY EXIT HATCH LATCH PIN NOT FULLY ENGAGED. ARMED LATCH PIN AND VERIFIED AFT LT EMERGENCY EXSDR YENA201703110184Thermocouple · failedDURING LANDING, ECAM NR 2 ENG SENSOR FAULT. REMOVED AND REPLACED NR 2 ENG UPPER LEFT AND UPPER RIGHT EGT PROBES IAW AMM 77-21-15.SDR YENA201703110183Probe · failedDURING LANDING, ECAM FOR NR 2 ENGINE SENSOR FAULT. REMOVED AND REPLACED THE NR 2 ENGINE EGT PROBES IAW AMM 77-21-15.SDR AALA201703319051Floor Panel · delaminatedDELAMINATION FOUND ON THE AFT CARGO BAY FLOOR PANEL 151FF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701, REVISION G.SDR AALA201703319049Floor Panel · crackedA CRACK WAS ON THE FORWARD FWD CARGO BAY FLOOR PANEL 131EF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703139004Lens · brokenEMERGENCY EXIT LIGHT LENS BROKEN AT ROW 1. REPLACED THE LENS.SDR CALA2017031000575Pin · out of positionLEFT OVERWING EXIT DOES NOT SHOW ARMED USING RENDER CHECK LIST AND AMM 52-71-00-70-001-A FOUND LT FWD OVER WING EMERGENCY EXIT LATCH PIN OUT OF DETENT. PLACED PIN IN CORRECT POSITION IAW AMM. ALL INDICATIONS NORMAL.SDR YENA201703090210Wire · brokenFT # 6403, JFK-LCQ. DURING HEAVY CHECK MAINTENANCE, CABIN EMRGENCY LIGHTS INOP AT ROWS 1, 15, 19 AND 23; REPAIRED BROKEN WIRES AT SEAT ROWS 1 & 23 ON EEPL CABLES IAW A320 ESPM 20-43-10. REMOVED & REPLACED 11WL & 12WL EPSU'S SYSTEM OPS CHECK GOOD IAW A320 AMM 3SDR YENA201703090177Connector · not seatedDURING HEAVY CHECK MAINTENANCE, RT OVERWING EPSU FAILED EMERGENCY LIGHT TEST AT PTP. RESEATED THE CONNECTOR IAW AMM 33-51-38. OPS CHECKED GOOD.SDR AALA201703109004Arming Lever · obstructedL2 DOOR SLIDE WILL NOT ARM. CLEARED DEBRIS FROM UNDER DOOR ARM ASSEMBLY.SDR YENA201703080176Pressure Panel · crackedDURING HEAVY CHECK MAINTENANCE, FOUND THE LT FUSELAGE FRAMES 35-36, PRESSURE PANEL HAS CRACK INDICATIONS. REPAIRED IAW EC A17-193-01, AND REO L20648.SDR YENA201703080175Box Beam · crackedDURING HEAVY CHECK MAINTENANCE, FOUND THE RIGHT SIDE BOX BEAM UPPER FLANGE AT FRAME 43, HOLE 9 CRACKED IN 6 AND 12 O`CLOCK POSITIONS, HOLE 10 HAS A CRACK IN THE 6 O`CLOCK POSITION, HOLE 11 HAS WAS OUT OF ROUND . THE BOX BEAM WAS REPAIRED IAW EC A320-53-1251-SDR YENA201703080174Box Beam · crackedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT LEFT BOX BEAM UPPER FLANGE AT FRAME 43 HAS A CRACK INDICATION IN HOLE 9 AT THE 6 OCLOCK POSITION. THE BOX BEAM FLANGE WAS REPAIRED ON EC A320-53-1251 CARD 440395-17020.SDR YENA201703080173Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THE L2 DOOR SILL CORRODED. R & R THE DOOR SILL IAW SRM 53-41-14.SDR YENA201703080172Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, FOUND THE L2 DOOR SILL CORRODED. R & R THE DOOR SILL IAW SRM 53-41-14.SDR YENA201703080171Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, FOUND THE FLOORBEAM -Y1732, FRAME 65+12 CORRODED. OUT OF LIMITS. REPLACED IAW SRM 52-00-14-283-002, AND 53-41-14, FIG 15.SDR YENA201703080170Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, FOUND THE FLOORBEAM Y506, FRAME 66 CORRODED. CORROSION BEYOND LIMITS, REPLACED THE FLOORBEAM IAW SRM 53-00-14-283-002.SDR YENA201703080169Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT FLOORBEAM -Y254 FRAME 18, CORRODED. CORROSION BEYOND LIMITS, REPLACED IAW SRM 53-00-14-283-002, AND 51-72-11.SDR YENA201703080168Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT FLOORBEAM Y765, FRAME 16, STRINGER 23L HAD CORROSION. CORROSION BEYOND LIMITS IAW SRM 53-11-14-283-003. REMOVED AND REPLACED IAW SRM 51-72-11.SDR YENA201703080167Door Sill · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT R2 DOOR SILL HAD CORROSION AT FWD GIRT BAR ATTACH PLATE FRAME 66+8. CORROSION BEYOIND LIMITS, REMOVED AND REPLACED R2 DOOR SILL.SDR YENA201703080166Support Channel · corrodedDURING HEAVY CHECK MAINTENANCE, FOUND THE SUPPORT CHANNEL AT FRAMES 69-70, STRINGER 23R CORRODED. REMOVED AND REPLACED THE SUPPORT CHANNEL IAW SRM 51-72-11, AND 52-41-14, FIG 002.SDR YENA201703080165Shear Web · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT AFT CABIN SHEAR WEB FROM FRAMES 69 - 70 AT STRINGER 23R HAD SEVERE CORROSION. REMOVED AND REPLACED THE SHEAR WEB IAW SRM 51-72-11, & 51-42-11.SDR YENA201703080164Dummy Rail · corrodedDURING HEAVY CHECK MAINTENANCE, IT WAS FOUND THAT FWD MAIN CABIN DUMMY RAIL Y503 FRAME 16 STRINGER 23L HAD CORROSION. REMOVED AND REPLACED THE DUMMY RAIL FROM FRAMES 12 TO 16 IAW SRM 51-72-11.SDR YENA201703070186Skin · damagedDURING HEAVY CHECK MAINTENANCE, FOUND THE NR 1 ENG AFT SECTION OF PYLON BOTTOM WING SKIN PANEL NR 3 SYSTEM MOUNTING PLATE AND GREEN HYD LINE DAMAGED. REPAIRED.
Back to Airbus A320-232