Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201702139041Support · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON LEFT HAND WING AILERON NR 3 SUPPORT ASSEMBLY. REPLACED AILERON NR 3 SUPPORT ASSEMBLY PER AMM 57-51-31-400-001-A.SDR YENA201701300056Battery Pack · failedFWD EPSU (10WL) FAILED OPS CHECK. R & R THE BATTERY PACK IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. PERFORMED OPS CHECK. OPS CHECK PASSED.SDR YENA201701300055Epsu · failedEMERGENCY LIGHTS BATTERY PACK FOR EPSU 11WL DID NOT ILLUMINATE WITH SWITCH IN THE ARM POSITION. R & R THE EPSU IAW AMM 33-51-38-000-002-A AND 33-51-38-400-002-A. PEFORMED EMERGENCY LIGHT OPS CHECK. OPS CHECK PASSED.SDR YENA201701300054Floor Support · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON LEFT SIDE FLOOR SUPPORT Y1292 AT FRAME 16. R & R FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201701300053Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS DISCOVERED ON LEFT SIDE FLOORBEAM Y1292 AT FRAME 20. R & R THE FLOORBEAM IAW SRM 51-72-11.SDR YENA201701300052Floorbeam · corrodedCORROSION WAS DISCOVERED INSIDE CABIN LEFT SIDE FLOORBEAM Y 503.2 FRAME 16. R & R FLOORBEAM IAW SRM 51-72-11.SDR YENA201701300051Floorbeam · corrodedCORROSION WAS DISCOVERED INSIDE CABIN LEFT SIDE FLOORBEAM 503.2 FRAME 14. R & R THE FLOORBEAM IAW SRM 51-72-11.SDR CALA2017013000221Light · malfunctionedEMERGENCY EXIT LTS ALL ON IN ARMED SWITCH POSITION CYCLED EMERG. LIGHT SWITCH EMERG LIGHTS OPS CHECK NORMAL OK TO CONTINUE.SDR CALA2017013000220Battery Pack · faultyEMERGENCY LIGHT TEST, REF 2 SVC, WILL NOT PASS. FAULTS SHOWS R-H UNIT FAULT. REPLACED EMERGENCY LIGHT BATTERY PACK AT RT EMERGENCY EXIT PER A MM 33-51-38-400-002. OPS CHECK GOOD.SDR CALA2017013000218Battery · faultyAFT LT EEL BATTERY FAILED CAPACITY TEST. REPLACED BATTERY REF AMM 33-51-38-000-002A AND 33-51-38-400-002A . OPS CHECKED OKSDR CALA2017013000219Light · malfunctionedEMERGENCY EXIT LIGHTS ON AT OVERWING AND AISLE LEFT SIDE OF CABIN. RESET SYSTEM AND OPS CKS NORMAL.SDR AALA201701309001Switch · defectiveAIRCRAFT WAS GROUNDED: EMERGENCY LIGHT ARE ON IN ARMED POSITION. REPLACED EMERGENCY LIGHT SWITCH ESPM 20-45-21 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-00.SDR AALA201703159013Hinge Fitting · damagedELONGATED HOLE ON LEFT FORWARD MLG DOOR HINGE ASSEMBLY BEARING. REPLACED HINGE FITTING ASSEMBLY IAW CMM 52-81-18.SDR YENA201701270050Computer · malfunctionedDURING CLIMB, CRUISE AND DESCENT WITH THE AUTOPILOT ON OR OFF, THE AIRCRAFT WAS TURNING LEFT. WITH AUTOPILOT ON L1.4 UNITS OF RUDDER TRIM. UNCOMMANDED JERKS ON RUDDER WITH AUTOPILOT OFF. NO APPARENT FLT CONTROL FAULTS ON FLT CONTROL PAGE OR HYD PAGE. ; PER TSSDR GTIA2017012701765Oxygen Mask · leakingEXPANDING TUBES ON CAPT'S O2 MASK LEAK AIR. R&R CAPTAIN'S O2 FULL FACE MASK IAW AMM 35-12-41 AND PERFORMED OPERATIONAL TEST AS PER AMM 35-12-41 OP'S TEST AND LEAK CHECK OK.SDR GTIA2017012601761Psu · malfunctionedPSU UNIT ROW 28 ABC HANING DOWN ON ONE SIDE. SECURED PSU UNIT IN ROW 28 ABC . FOUND NO DEFECTS ON STORAGE PASSENGER MODULED IAW AMM 35-21-41-420-050-A. ACCOMPLISHED PSU DROP TEST . DROP TESTED GOOD IAW AMM 35-23-00-710-001-A .SDR AALA201701279008Power Supply · failedEMERGENCY LIGHT POWER SUPPLY UNIT EXTERNAL LOAD FAULT ON CIDS. REPAIRED SEAT MOUNTED EMERGENCY LIGHT WIRES AT ROW 7 AND REPLACED 11WL EMERGENCY POWER SUPPLY IAW TSM 33-51-00-810-808-A.SDR AALA201701279006Wire · damagedEMERGENCY LIGHT POWER SUPPLY EXTERNAL LOAD FAULT ON CIDS. REPAIRED SEAT MOUNTED EMERGENCY LIGHT WIRES AT ROW 7 AND REPLACED 11WL EMERGENCY POWER SUPPLY IAW TSM 33-51-00-810-808-A.SDR AALA201703159008Pressure Deck · corrodedCORROSION ON FORWARD CARGO BAY PRESSURE DECK UPPER SURFACE AT -Y765 BETWEEN FRAMES 35 AND 36. REPAIRED THE PRESSURE DECK SURFACE IAW EA 267426.SDR AALA201703039020Floor Panel · delaminatedDELAMINATION ON FORWARD CARGO BAY FLOOR PANEL 131EF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201702139027Floor Panel · delaminatedDELAMINATION ON FORWARD GALLEY FLOOR PANEL 232DF. REPLACED THE FLOOR PANEL IAW SRM 51-72-11 AND DRAWING D53610668 REVISION B.SDR AALA201702139026Floor Panel · delaminatedDELAMINATION ON TOP LAYER OF COCKPIT FLOOR PANEL 212CF. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201702139024Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 231CF. REPLACED FLOOR PANEL IAW SRM 53-02-00.SDR AALA201702169004Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON AFT GALLEY FLOOR PANEL 221PF. REPLACED FLOOR PANEL PER SRM 53-12-00 AND IRM 9701 REVISION G.SDR AALA201702159012Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON FORWARD GALLEY FLOOR PANEL 231 FF. REPLACED FLOOR PANEL 231FF PER SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201702159008Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON FORWARD GALLEY FLOOR PANEL 232FF. REPLACED FLOOR PANEL 232FF PER SRM 53-12-00 AND IRM 9701 REV G.SDR AALA201702139029Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON FORWARD GALLEY FLOOR PANEL 231 BF. REPLACED FLOOR PANEL 231BF PER SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201701289001Floor Panel · damagedMAINTENANCE FOUND SPONGY FLOOR PANEL 231AF. REPLACED THE FLOOR PANEL IAW AMM 53-12-12.SDR GTIA2017012501758Unknown · odorJUST AT TAKE OFF AND LANDING ALL 4 FA TOLD ME WHEN WE ARRIVED IN RSW, THERE WAS A MUSTY, DIRTY FEAT, OR MOLD SMELL THROUGHOUT THE ENTIRE CABIN. THE APU WAS OFF AT THOSE TIMES THEY SMELLED THE ODOR. FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED, OSDR YENA201701250048Switch · failedEMERGENCY EXIT LIGHT DID NOT ILLUMINATE WITH GEAR DOWN AND NO SMOKING SWITCH IN AUTO POSITION RESULTS IN BLUE SIGNS ON ECAM. R & R NO SMOKING TOGGLE SWITCH. ALL FUNCTIONS AND OPS CHECKED NORMAL IAW AMM 33-50-00.SDR CALA2017012300174Battery Pack · malfunctionedEPSU BATTERY RIGHT FAILED A TEST WITH BATTERY FAULT. REMOVED AND REPLACED THE BATTERY PACK, OP CHECKED NORMAL IAW AMM 33-51-38.SDR CALA2017012300173Power Supply · faultedEPSU UNIT AFT L MESSAGE AFTER EMERGENCY LIGHT TEST. PERFORMED A EPSU BITE TEST IAW AMM 33-51-38 SYTEM TESTED OK.SDR CALA2017012300172Power Supply · faultedEPSU UNIT EMERGENCY RT MESSAGE AFTER COMPLETION OF CABIN EMERGENCY LIGHT OPERATIONAL CHECK. REPLACED THE POWER SUPPLY IAW MM 33-51-38, OPS CHECKED GOOD.SDR YENA201701220045Battery Pack · failedEMERGENCY LIGHTS IN AUTO DID NOT ILLUMINATE WHEN POWER DROPPED OFF. R & R THE BATTERY PACK AT 10WL IAW AMM 33-51-00. OPS CHECKED GOOD.SDR AALA201701249011Warning System · false activationAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW RECEIVED AN EMERGENCY EXIT WARNING DURING TAKEOFF ROLL AND ABORTED THE TAKEOFF AT 70 KNOTS. THE FLIGHT ATTENDANTS WENT BACK AND CHECKED THE HANDLE ON THE HATCH, THE LIGHT EXTINGUISHED AND ECAM WARNING WENT AWAY. THE FLIGHSDR AALA201701239009Water Heater · odorAIRCRAFT WAS NOT GROUNDED. FORWARD LAVATORY HOT WATER HEATER SMELLS LIKE IT IS BURNING. MAINTENANCE REPLACED WATER HEATER PER AMM 38-12-16.SDR AALA201703019022Floor Panel · delaminatedDELAMINATION ON TOP LAYER OF PASSENGER CABIN FLOOR PANEL 251RF. REPLACED FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201702219008Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON TOP LAYER OF PASSENGER CABIN FLOOR PANEL 252NF. REPLACED FLOOR PANEL 252NF PER SRM 53-02-00 AND IRM 9701 REVISION G.SDR YENA201701210044Apu · odorFLIGHT ATTENDENTS AND PAX SMELLED A STRONG FOUL ODOR PASSING THROUGH 10,000 FT DURING DESCENT; FOUND APU TO BE THE SOURCE OF THE ODOR. R & R THE APU.SDR AALA201701229004Panel · unsecureAIRCRAFT WAS NOT GROUNDED. FORWARD ENTRY LOWER EXIT LIGHT PANEL NOT SECURED. REINSTALLED PANEL AT L1 ENTRY DOOR AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR YENA201701210043Sensor · failedDURING APPROACH, FLAPS FAILED BETWEEN 1 & 2. CYCLED IAW ECAM. FAILED A SECOND TIME. RECOVERED FLAP AFTER CYCLING TO 0 ON GO AROUND. R & R RIGHT APPU (30CV) SENSOR IAW AMM 27-51-18. PERFORMED SYSTEM OPS CHECK. SYSTEM OPS CHECK PASSED. ALL SELECTED FLAP POSITSDR YENA201701210042Wire · brokenDURING MAINTENANCE, SEAT 18 EMERGENCY LIGHT INOPERATIVE. FOUND A BROKEN WIRE.; R & R SEAT 18 TERMINAL IAW AMM 33-51-08. OPS CHECKED GOOD IAW AMM 33-51-00.SDR YENA201701210041Blower · failedDURING CRUISE, FLIGHT CREW RECEIVED VENT EXTRACT FAULT. CREW ELECTED TO PERFORM AN AIR RETURN, SINCE VENT BLOWER WAS ALREADY ON DEFERRAL. ACFT LANDED UNEVENTFULLY. R & R BLOWER FAN 20 HQ IAW AMM 21-26-51. PERFORMED OPS CHECKED. OPS CHECK PASSED.SDR CALA2017012100149Battery · faultyEMERGENCY LIGHTS CHECK,"EPSU BATTERY AFT L" REPLACED EMERGENCY BATTERY PER MM 33-51-38. EMERGENCY LIGHTS OPS CK GOOD.SDR AALA201701259010Skin · crackedCRACKS ON FUSELAGE SKIN FASTENER HOLES, AFT UPPER HOLE IN FRAME 35 AT STRINGER 30L. REPAIRED THE SKIN IAW EA 266178.SDR AALA201701219003Cover · missingAIRCRAFT WAS NOT GROUNDED. MISSING EMERGENCY EXIT LIGHT COVER AT DOOR 2R. MAINTENANCE INSTALLED NEW LENS COVER PER AMM 25-10-00.SDR GTIA2017012001752A/C Pack · contaminatedON DESCENT PASSING THROUGH 4000FT FAINT FUME OF DIRTY SOCK SMELL IN COCKPT. FA REPORTED OVERPOWERING ODOR IN CABIN. IAW COM PROCEDURE SHUTOFF NR 1 PACK AND CLOSED CROSSBLEED AND ODOR DISSIPATED.. PERFORMED IDENTIFICATION OF CABIN ODOR IAW TSM 05-50-00-810-831-SDR AALA201704179006Box Beam · crackedA CRACK INDICATION ON THE LEFT PASSENGER CABIN SIDE BOX BEAM SECOND FASTENER HOLE, TWO INCHES FORWARD OF FRAME 43 AND Y1650. REPAIRED THE BOX BEAM IAW EO 5315Y066.SDR AALA201704179005Box Beam · crackedA CRACK INDICATION ON RIGHT PASSENGER CABIN SIDE BOX BEAM, ONE INCH FORWARD OF FRAME 43 AND -Y1650. REPAIRED THE BOX BEAM IAW EO 5315Y066.SDR AALA201704179003Box Beam · crackedCRACK INDICATION ON THE LEFT PASSENGER CABIN SIDE BOX BEAM FIRST FASTENER HOLE, FORWARD OF FRAME 43 AND Y1650. REPAIRED THE BOX BEAM IAW EO 5315Y066.
Back to Airbus A320-232