SDR YENA201612311121Battery · no testWHILE PERFORMING TASK CARD A320-33-51-00-710-003, FOUND EPSU BATTERY CAPACITY FOR THE EMERGENCY LIGHTS NEEDS REPLACEMENT. R & R THE ESPU IAW AMM 33-51-38. OPS CHECK PASSED.SDR AALA201701039010Pump · faultedCENTER FUEL TANK PUMP 1 FAULT. PERFORMED TSM 28-21-00-810-813-A, NO ECAM FAULTS NOTED FUNCTIONAL TEST CENTER TANK FUEL PUMP NR 1 OPERATIONAL CHECKED GOOD. CENTER TANK FUEL PUMP GFI OPERATIONAL CHECKED GOOD PER AMM 28-18-00-710-801-A. AS A PRECAUTION, REPLACED SDR AALA201701019004Damper · low pressureL1 DOOR DAMPER INDICATES BELOW THE LIMIT. SERVICED THE DOOR DAMPER IAW AMM 52-40-00.SDR YENA201612301120Bypass Valve · failedFLT 778, LAS-BOS, AIR RETURN BACK TO LAS. FLIGHT CREW RECEIVED THE FOLLOWING MESSAGE ON ECAM, HYD G ENG 1 PUMP LO PR AND HYD G SYS LO PR. CREW ELECTED TO PERFORM AIR TURNBACK. R & R MLG BYPASS VALVE IAW AMM 32-31-13. PERFORMED OPS CHECK AND LEAK CHECK. OPS CHESDR CALA2016123001201Battery Pack · no testEMERGENCY LIGHT BATTERY AT 3L FAILED CAPACITY CHECK. REPLACED BATTERY IAW MM 33-51-38-400-002-ASDR CALA2016123001200Battery Pack · no testBATTERY PACK AT EMERGENCY EXIT RIGHT FAILED CAPACITY TEST. REPLACED THE BATTERY PACK IAW MM 33-51-38-400-002-ASDR CALA2016123001188Outflow Valve · faultyEXCESS CABIN ALTITUDE DISPLAYED ON UPPER ECAM SCREEN.. EMERGENCY DECLARED. REPLACED OUTFLOW VALVE AND #1 CABIM PRESSURE CONTROLER REF AMM 2 1-31-51 AND AMM 21-31-34 OPS CHECK GOOD REF AMM 21-31-51,21-31- 00,TASK 05-53-00,AMM 21-31-00-710-0032-ASDR YENA201612301119Power Supply · no testCABIN EMERGENCY LIGHTS TEST FAILED IN POSITIONS 42WL, 53WL. R & R THE EPSU (12WL) IAW AMM 33-51-38. PERFORMED OPS CHECK. OPS CHECK PASSED. ACFT OK FOR SERVICE.SDR GTIA2016123001722Oxygen Mask · inoperativePRIMARY OBSERVER`S OXYGEN MASK INOPERATIVE. R & R OXYGEN MASK, OPS & LEAK TESTED GOOD. IAW AMM 35-12-41.SDR AALA201701039008Line · leakingFLIGHT CREW REPORTED THEY LOST THE YELLOW HYDRAULIC SYSTEM ENROUTE. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED AND LANDED SAFELY WITHOUT FURTHER INCIDENT. AIRCRAFT WAS GROUNDED. MAINTENANCE REPLACED THE NR 2 ENGINE HYDRAULIC LINE IAW AMM 29-11-51.SDR AALA201612309010Gasket · leakingAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED A LOSS OF GREEN HYDRAULIC SYSTEM PRESSURE AND DIVERTED TO ORD WHERE THE AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE RIGHT SPOILER SERVO VALVE GASKET SEAL PER AMM 27-64-51.SDR AALA201612299011Latch · dirtyAIRCRAFT WAS NOT GROUNDED. 1L ENTRY DOOR SLIDE ARMED INDICATION BLINKS ON-OFF. CLEANED 1L DOOR SLIDE GIRT BAR LATCHES. DOOR ECAM SLIDE INDICATION CHECK GOOD PER TSM TASK 52-11-00-810-806-A& AMM 25-62-00.SDR GTIA2016122801721Coffeemaker · inoperativeA PLUME OF SMOKE AND A BURNING RUBBER ODOR IN AFT GALLEY REPORTED BY FLT ATTENDANT. INSPECTED THE ACFT IAW TSM 05-50-00-810-831A, REMOVED, INSPECTED AND INSTALLED AFT GALLEY COFFEEMAKER, PERFORMED OPS TEST OF HOT PLATE , WORKED NORMAL, OPENED AND INSPECTED ASDR AALA201612299008Lens · missingAIRCRAFT WAS NOT GROUNDED. MISSING SEAT MOUNTED EMERGENCY LIGHT LENS AT ROW 3L. REPLACED LENS PER AMM 33-51-18.SDR CALA2016122701182Flashlight · inoperativeFIRST OFFICER`S FLASHLIGHT INOPERATIVE. REPLACED THE FLASHLIGHT ASSY.SDR YENA201612271109Smoke Warning · activatedECAM DISPLAYED SMOKE LAV. F/A ADVISED THERE WAS WHITE SMOKE IN LAV E. FLIGHT CREW COMPLIED WITH QRH PROCEDURE, SMOKE LAVATORY SMOKE (S3) WHICH DROVE CREW TO PERFORM SMOKE, FUMES, AND AVIONICS SMOKE PROCEDURE (S7). BASED ON THAT PROCEDURE, CREW ELECTED TO DIVERSDR YENA201612261118Light · malfunctionedDURING TAXI OUT, WITH BOTH ENGINES RUNNING, THE CABIN EMERGENCY LIGHT SYSTEM ACTIVATED ; RESET ALL POWER EMERGENCY EXIT LIGHTS. OPS CHECK NORMAL IAW AMM 24-38-00.SDR AALA201612279013Manifold · leakingON ARRIVAL, CAPTAIN ADVISED DISPATCH THAT YELLOW HYDRAULIC RESERVOIR LOW LEVEL ILLUMINATED AND CONFIRMED INDICATION. EMERGENCY DECLARED, LANDED WITHOUT INCIDENT.AIRCRAFT WAS GROUNDED. MAINTENANCE FOUND LOOSE NUT ON YELLOW HYDRAULIC POWER MANIFOLD. THIGHTENED SDR GTIA2016122601718Oxygen Box · inoperativePRESS TO TEST OXYGEN MASK INOPERATIVE. R & R CAPTAIN`S OXYGEN BOX ASSY IAW AMM 32-12-41-000-001-A\400-001-A, OPS & LEAK CHECKED GOOD.SDR CALA2016122601172Wire · brokenFLOOR PROXIMITY EMERGENCY LIGHT AT SEAT 38C WIRES BROKE FROM LIGHT ASSY ON SEAT BUMPER PANELS. REPLACED EEL PATH LIGHT HARNESS. OPS CHECKED NORMAL.SDR YENA201612241108Idg · failedFLIGHT CREW PERFORMED AN AIR RETURN, DUE TO RECEIVING ELECTRIC IDG 1 OIL LOW PRESSURE ON ECAM. R & R ENGINE NR 1 IDG IAW 24-31-50. PERFOMED OPS CHECK. OPS CHECKED PASSED.SDR GTIA2016122401716Unknown · odorODOR EVENT DURING DECENT WHILE PASSING THROUGH CLOUDS. MUSTY DRY ODOR, ONLY NOTICED IN COCKPIT, ODOR WENT AWAY AFTER TURNING OFF PACK 1. TROUBLESHOOT THE CAUSE OF COCKPIT ODOR IAW TSM 05-50-00-810-831-A. OPERATED PACK 1. NO ODOR DETECTED. OPS CHECK GOOD.SDR CALA2017010496075Door Sill · corrodedCORROSION ON LT DOOR SILL AFT CORNER FITTING AT L2 DOOR. REMOVED & REPLACED IAW SRM 51-42-11.SDR GTIA2016122301712Oxygen Mask · unwanted deployOXYGEN MASK OVER 5ABC DROPPED. SECURED THE OXYGEN MASK IAW AMM 35021-43.SDR CALA2017010496074Stringer · corrodedEVIDENCE OF CORROSION ON STRINGER 43R , BETWEEN FRAMES 32 AND 33. REMOVED & REPLACED THE STRINGER IAW SRM 51-42-11.SDR CALA2017010496073Shear Tie · corrodedFWD CARGO BAY AT FRAME 30, BETWEEN STRINGERS 42-43R SHEAR TIE HAS CORROSION. REMOVED & REPLACED THE SHEAR TIE IAW SRM 51-42-11.SDR CALA2017010496072Shear Tie · corrodedSHEAR TIE AT FRAME 31, BETWEEN STRINGERS 41-42L HAS CORROSION. REMOVED & REPLACED THE SHEAR TIE IAW SRM 51-42-11.SDR CALA2017010496071Shear Tie · corrodedFWD CARGO BAY AT FRAME 32 BETWEEN STRINGERS 42-43R SHEAR TIE HAS CORROSION. REMOVED & REPLACED THE SHEAR TIE IAW SRM 51-42-11.SDR YENA201612221105Switch · failedEMERGENCY LIGHTS REMAIN ILLUMINATED AFTER ENGINE START. R & R THE EMERGENCY LIGHT SWITCH IAW 31-51-08. PERFORMED OPS CHECK. OPS CHECKED PASSED.SDR CALA2016122201159Wire · brokenEMERGENCY LIGHT SYS TEST FAILED ON 2SVC SYS TEST DOOR 1L ESCAPE SLIDE LIGHTING IS INOP BROKEN WIRE BETWEEN CON N 2871VC PIN B AND 2819VC PIN K, OF DOOR 1L WIRE HARENESS. 2871V C IS BEHIND DOOR SLIDE AND 2819VC IS BEHIND FWD LAV. REPAIRED BROKEN GROUND WIRE AT SDR CALA2016122201158Power Supply · faultyFAILED EMERGENCY EXIT LIGHT TEST. FOUND EPSU FAULTED. LT OVERWING 11WL. REPLACED THE EPSU AND BATTERY IAW AMM 33-51-38. OPS CHECKED GOOD.SDR CALA2016122201157Battery · dischargedFLASHLIGHT BATTERY INOPERATIVE IN THE COCKPIT. REPLACED THE BATTERY IAW AMM 25-65-98-910-001-ASDR CALA2016122101148Battery Pack · failedAFT CABIN EEL BATTERY PACK FAILS CAPACITY CHECK. REPLACED BATTERY PACK REF AMM 33-51-38-000-002A AND 33-51-400- 002A. OPS CHECKED OK.SDR AALA201612219003Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON FLOORBEAM AT FR 66 AND -Y765. REPLACED FLOORBEAM PER SRM 51-42-11.SDR AALA201612219001Skin · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON UPPER SURFACE OF RIGHT ELEVATOR 37 INCHES FROM INBOARD END AND 12 INCHES FROM TRAILING EDGE. REPAIRED ELEVATOR PER SRM 55-21-11.SDR CALA2016122101142Power Supply · inoperativeTHE PTP EMERGENCY LIGHT TEST FAILED FOR EPSU UNIT EMR R, AFT L. REPLACED FWD LT POWER SUPPLY UNIT AND BATTERY PN 31-3350-9-9001 PN 3214-54-10 SN 1373 RESET EMERG LIGHT CBS. SYSTEM CKS OK.SDR CALA2016122101141Power Supply · inoperativeTHE PTP EMERGENCY LIGHT TEST FAILED FOR EPSU EXT LOAD FWD L. REPLACED RT OVERWING EPSU AND BATTERY.SDR CALA2016122101140Power Supply · faultedLT OVERWING EXIT EMERGENCY POWER SUPPLY UNIT IS FAULTING DURING EEL TEST. REPLACED EPSU REF AMM 33-51-38-000-001A AND 33-51-38-400-001A. OPS CHECKED OK.SDR YENA201612201117Angle · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT FLOOR ENTRANCE AREA ANGLE AFT PORTION BETWEEN FRAME 68-69 ; R & R THE ANGLE IAW SRM 51-72-11 REV. 117 & SRM 51-42-11 REV 117.SDR YENA201612201116Shear Plate · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT RT SHEAR PLATE BETWEEN FRAMES 69-70. R & R THE SHEAR PLATE IAW SRM 51-72-11 REV. 117.SDR YENA201612201115Shear Plate · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT LT SHEAR PLATE BETWEEN FRAMES 69-70. R & R THE SHEAR PLATE IAW SRM 51-72-11 REV. 117.SDR YENA201612201114Seat Track · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON THE FWD SEAT TRACK AT FRAME 19 Y-765. R & R THE SEAT TRACK IAW SRM 51-72-11 REV. 117.SDR YENA201612201113Seat Track · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON SEAT TRACK FRAMES 12-16 Y-503.2. R & R THE SEAT TRACK IAW SRM 51-72-11 REV. 117.SDR YENA201612201112Floor Support · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT FLOOR SUPPORT AT FRAMES 68-69. R & R THE FLOOR SUPPORT IAW SRM 51-72-11 REV. 117.SDR YENA201612201111Floor Support · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT FLOOR SUPPORT Y765. R & R THE FLOOR SUPPORT IAW SRM 51-72-11.SDR YENA201612201110Floor Support · corrodedDURING HEAVY CHECK MAINTENANCE, CORROSION WAS FOUND ON AFT FLOOR SUPPORT. R & R THE FLOOR SUPPORT IAW SRM 51-72-11 REV. 117.SDR CALA2017010496070Stringer · corrodedFWD CARGO BAY STRINGER 41R HAS CORROSION BETWEEN FRAMES 32 AND 33. REMOVED AND REPLACED THE STRINGER IAW SRM 51-42-11.SDR CALA2017010496069Shear Tie · corrodedFWD CARGO BAY SHEAR TIE AT FRAME 31 BETWEEN STRINGERS 42 AND 43R HAS CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-44-11.SDR CALA2017010496068Shear Tie · corrodedFWD CARGO BAY FRAME 32 BETWEEN STRINGERS 41-42R SHEAR TIE HAS CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-44-11.SDR CALA2017010496067Shear Tie · corrodedFWD CARGO BAY SHEAR TIE AT FRAME 31 BETWEEN STRINGERS 42-43R HAS CORROSION. REMOVED AND REPLACED SHEAR TIE IAW SRM 51-44-11
Back to Airbus A320-232