Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA20150921427Servo Valve · faultyAIR RETURNED, AFTER TAKEOFF RECEIVED ECAM MESSAGE NOSE WHEEL STEERING FAULT. TROUBLESHOOT TO STEERING SERVO VALVE. R & R SERVO VALVE, 6GC, IAW AMM 32-51-51. LEAK AND OPS CHECK GOOD.SDR YENA20150921426Motor · seizedDIVERTED DUE TO ELECTRICAL ODOR AND VIBRATION OCCURRENCE. PERFORMED AMM INSPECTIONS 21-00-00-810-804-A ISOLATION OF AC SYSTEM NOISE AND AMM 24-00-00-810-823-A ISOLATION OF ELECTRICAL BURNING ODOR. FOUND ODOR FROM AVEC SYS BLOWER MOTOR 20HQ HAD SEIZED. R & RSDR YENA20150921425Battery Pack · failedDURING MAINTENANCE AND COMPLETING TASK CARD A320-33-51-00-710-003, UNABLE TO PERFORM TEST DUE TO EPSU BATTERY FWD LT FAULTED. CEILING PANEL 221BC, REMOVED FOR MAINTENANCE. REPLACED FWD LEFT BATTERY ON EPSU IAW AMM 33-51-38. OPS TESTED GOOD. CEILING PANEL 221SDR GTIA2015092001634Container · openOXYGEN MASK COMPARTMENT, ROW 18 ABC OPEN. STOWED MASK COMPARTMENT AT ROW 18 ABC IAW AMM 35-21-43. PERFORMED OPS DROP CHECK OF PASSENGERS MASKS IAW AMM 35-23-00. OPS CHECK GOOD.SDR CALA2015092194381Light · no testREFERENCE 2 SERVICE, EMER LIGHT SYS TEST FAILS. RESET EMER EXIT LIGHT BREAKERS H5, H6 & H7. ACCOMPLISHED EMER EXIT LIGHT TEST IAW 31-51-00-7 10-001. OPERATIONS CHECKED OK.SDR CALA2015092194380Battery · dischargedREFERENCE 2 SERVICE, EMER LIGHTS FAIL TEST. R & R LT FWD EPSU BATTERY, BATTERY ONLY, IAW AMM 33-51-38-000-002A & 33-51-38-400-002A. OPERATIONS CHECKED OK.SDR YENA20150919431Seat Track · corrodedDURING HEAVY MAINTENANCE, AFT WET AREA LT SIDE DUMMY BEAM FOUND CORRODED AROUND THE F/A SEAT TIE DOWN AT FRAME 66. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. R & R LT AFT WET AREA DUMMY BEAM AT FRAME 66 IAW SRM 51-54-11. ITEM WAS RE-EVALUATED AND NSDR YENA20150919423Floorbeam · corrodedDURING HEAVY MAINTENANCE, FLOORBEAM Y503 HAD CORROSION AT ZONE 221, FRAME 16. REMOVED CORROSION ON FLOORBEAM Y503 FOUND TO BE OUT OF LIMITS ORIGINAL MATERIAL. 149" MATERIAL LOSS .065" REMOVED MATERIAL .084" LENGTH 2" X 2" IAW SRM 53-11-14, PG 125. REMOVED CSDR CALA2015092194378Brace · corrodedAT FRAME 66, STRINGER 25 BRACE, FROM FRAME TO STRINGER CORRODED. R & R SECTION OF STRINGER 25R & INSTALLED BETWEEN FRAME 66.5 - 67.5 IAW SRM 53-00-13. ACCOMPLISHED AT LCQ C4.SDR GTIA2015091501365Slide · inoperativeL1 DOOR SLIDE INOPERATIVE. SLIDE REMOVED. GIRT BAR AND COVER LT ONBOARD ACFT. (DMI) INSTALLED ESCAPE-SLIDE RAFT PACK, ASSEMBLY IN L1 DOOR IAW AMM 25-62-44.SDR CALA2015091694362Beam · crackedLEFT SIDE BOX BEAM, UPPER FLANGE AT FRAME 43, HAS CRACK INDICATION AT HOLE NR 10, AFT SIDE OF HOLE, 6 O'CLOCK, FROM TOP SURFACE OF FLANGE TO A DEPTH OF .110". REPAIRED ON EA 5331-01704 OPS 3 - 12.SDR CALA2015091694361Beam · crackedLEFT SIDE BOX BEAM, UPPER FLANGE AT FRAME 43, HAS CRACK INDICATION AT AFT HOLE NR 9, FWD & AFT SIDES OF HOLE, 6 O'CLOCK & 12 O'CLOCK, FROM TOP SURFACE OF FLANGE TO A DEPTH OF .230". REPAIRED ON EA 5331-01704 OPS 3 - 12.SDR CALA2015091694360Stringer · corrodedFUSELAGE STRUCTURE, BENEATH OUTFLOW VLV, FRAME 66, STRINGER 31R, CORROSION. R & R STRINGER 31R, FROM FRAME 64 - 66 IAW SRM 51-42-11 PGS 25 - 26.SDR AALA201509169011Beam · crackedCRACK INDICATION IN AFT FASTENER HOLE OF RT SIDE BOX BEAM FLANGE AT FRAME 43 & -Y1650. REPAIRED IAW EA 254399 & EO 5315Y066.SDR YENA20150914422Proximity Sensor · out of rigFLIGHT DIVERTED, ON APPROACH CALLING FLAPS 1 ECAM FCTL FLAPS LOCKED; TS IAW TSM 27-51-00, FOUND PROXIMITY SENSOR 37CV X DIMENSION TO BE OUT OF RIG AND SENSOR CONDUIT CHAFED. R & R SENSOR AND SDJ IAW AMM 27-51-44, OPS CHECK GOOD.SDR CALA2015091694359Slide · defectiveEMERGENCY LIGHT FAILED TEST, FAULT LT FWD EXT LIGHTS. REPLACED SLIDE PACK DOOR 1 LT IAW AMM 25-62-44. EMER LIGHT TESTED OK.SDR CALA2015091694357Stringer · corrodedAT FRAME 66, STRINGER 32R CORRODED UNDER & BEHIND FRAME. R & R STRINGER 32R AT FRAME 66 IAW SRM 51-42-11 PARA 7.SDR CALA2015091694356Stringer · corrodedSTRINGER 26R FWD & AFT OF FRAME 66 HAS CORROSION. R & R STRINGER IAW SRM 51-42-11 PGS 25 - 27.SDR CALA2015091694355Cleat · corrodedAT FRAME 66, STRINGER 28R CLEAT, AFT OF FRAME CORRODED. R & R CLEAT IAW SRM 51-42-11 PG 25 PARAGRAPH 7.SDR CALA2015091494349Light · inoperativeEMERGENCY LIGHT FAILS TEST, FAULT LT FWD EXTERIOR LIGHTS. TROUBLE SHOT TO DOOR 1L SLIDE PACK. HAS OPEN IN ONE BULB, WILL NEED TO HAVE SLIDE PACK REPLACED.SDR CALA2015091494348Battery · dischargedEMERGENCY LIGHTS FAILED TEST IAW 2 SVC. REPLACED BATTERY IAW AMM 33-5 1-38. TESTED OK.SDR AALA201509149009Cover · looseFLIGHT 574 NOTIFIED DISPATCH THAT THEY BEGAN TO LOSE OIL QTY WHILE EN-ROUTE. THEY STATED THAT IT WAS OK TO CONTINUE & RECEIVED NO ECAM MSGS RELATED. ON APPROACH, THE CREW ASKED FOR NO UNDUE DELAYS DUE TO OIL QTY BEING LOW. ATC DECLARED AN EMER FOR THE FLIGHSDR CALA2015091494346Cleat · damagedTWO EACH ENLARGED LOCK FASTENER HOLES ON CLEAT, BY FRAME 65 & STRINGER 31R. R & R CLEAT IAW GPM 07-35-0 & SRM 51-42-11 PARA 6 & 7.SDR AALA201509139006Pump · defectiveDIRTY SOCK ODOR IN CABIN ON DECENT. REPLACED THE OIL PUMP IAW AMM 49-91-45-0401.SDR YENA20150911421Unknown · malfunctionedDURING CLIMB, GROSS NAVIGATION ERROR AFTER DEPARTURE. 85-90 MILE DISCREPANCY BETWEEN MAP AND CURRENT IDENTIFIED POSITION; RESET IRS NR 1,2,3 IAW AMM 34-13-00, RESET GPS IAW 34-36-00. OPS CHECK IS NORMAL.SDR AALA201509129004Lens · looseAFT LT EMER LIGHT COVER LOOSE. COVER SECURED.SDR YENA20150910417Battery Pack · inoperativeDURING MAINTENANCE FOUND AISLE EMERGENCY LIGHTS OUT ROW 25, 21, 17 AND 13. R & R EMERGENCY LIGHT POWER SUPPLY AND BATTERY IAW AMM 3351-38. OPS CHECKS OK.SDR CALA2015091194295Relay · faultyCREW REPORT ENG 1 N1 IS OPERATING IN THE UNRATED MODE, IAD EFS AMT'S. REPLACED RELAY BOX IAW AMM 71-51-49 401. ACCOMPLISHED 2 EACH AUTO STARTS, EPR INDICATION NORMAL, PFR'S CLEAN, ALSO ACCOMPLISHED CAT III CHECK IAW AMM 22-97-00.SDR CALA2015091194292Light · failedEMERGENCY LIGHT TEST FAILED IAW NR 2 SVC. EPSU BATTERY EMER LT. OPERATIONS TESTED IAW AMM 33-51-0 0-710-001-A.SDR YENA20150909415Battery Pack · inoperativeDURING HEAVY MAINTENANCE, FOUND EMERGENCY LIGHTS FAIL EPSU BATTERY FWD LT. R & R 10WL EPSU BATTERY. OPS CHECK NORMAL REF AMM 33-51-38 PB 401.SDR AALA201509129013Check Valve · leakingEMERGENCY LANDING, AS FLIGHT 507 WAS EN-ROUTE,, THE CREW NOTED LOW PRESS ON THE GREEN HYD SYS. AN PHONE PATCH WAS ESTABLISHED WITH DISPATCH & TECH OPS. IT WAS DEEMED PRUDENT TO CONTINUE ON, DUE TO LONG RNWYS, RESCUE EQUIPMENT & MX FACILITIES. THE FLIGHT CRESDR CALA2015091194293Skin · saturatedRIGHT ELEV UPPER SKIN PANEL HAS TRAPPED WATER INDICATION IN 3 LOCATIONS, 133" FROM INBD END, 16" FROM TE 2" DIAMETER, NEXT 131" FROM INBD END, 10" FROM TE 2" X 3"DIAMETER, NEXT 117" FROM INBD END, 12" FROM TE .250" DIAMETER, CARRIED FROM 12 13 14. CUT OUT TSDR CALA2015091194289Beam · crackedLEFT SIDE BOX BEAM UPPER FLANGE AT FRAME 43 HAS CRACK INDICATION AT HOLE NR 9 AT 11 O`CLOCK POSITION. CRACK IS INSIDE AREA A. HOLE DIAMETER START AT .248 AT LOWER SURFACE OF BOX BEAM UPPER FLANGE TO .252 AT UPPER SURFACE OF PRESS PLATE FITTING. REPAIRED IAWSDR AALA201509099007Power Supply · intermittentEMERGENCY EXIT LIGHTS ON INTERMITTENTLY. R & R EMER POWER SUPPLY LT AFT 13WL & BATTERY PACK 33-51-38. NO FAULTS NOTED ON GND AT THIS TIME.SDR AALA201509129002Fan · leakingCABIN ODOR AFTER APU BLEED ON. FOUND OIL IN THE APU INLET & REPLACED THE APU OIL COOLER FAN. ACCOMPLISHED A SATISFACTORY LEAK & OPERATIONAL CHECK IAW AMM 49-52-51.SDR CALA2015091094287Sliding Window · crackedAIR RETURN DUE TO FIRST OFFICER SLIDING WINDOW CRACKED. EMER DECLARED, FIRST OFFICERS WINDOW SHATTERED. REPLACED WINDOW IAW 56-12-11-400-002A. OPERATIONS CHECKED GOOD.SDR CALA2015091094285Regulator Valve · faultyAFTER TAKEOFF CREW LOST BOTH ENG BLEEDS & CROSS BLEED VLV, STARTED APU FOR BLEED, DIVERTED. ACCOMPLISHED BMC BITE CHECKS OK. ACCOMPLISH FAULT CHECK OF CROSS BLEED VLV POSITION CONTROL OK. REPLACED PRESS REGULATOR VLV. OPERATIONS CHECKED GOOD.SDR AALA201509119005Skin · saturatedC11 CHECK, LT ELEVATOR UPPER SURFACE SKIN HAS EVIDENCE OF WATER INGRESS IN SEVERAL LOCATIONS. REPLACED LT ELEVATOR IAW AMM 27-34-41-0401. OPERATIONS CHECKED & RIGGED CHECKED OK.SDR AALA201509079005Lens · missingEMERGENCY LIGHT AT SEAT ROW 11L IS MISSING THE LENS CAP. REPLACED EMER LIGHT IAW AMM 33-51-18.SDR AALA201509119011Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 5, HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR AALA201509119010Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 3, HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR AALA201509119009Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 6, HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR AALA201509119008Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 4 HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR AALA201509119007Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 2 HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR AALA201509119006Hinge Fitting · wornC11 CHECK, LT ELEVATOR NR 1 HINGE FITTING BEARING WORN. REPLACED HINGE FITTING IAW AMM 55-16-42.SDR CALA2015090894272Door Sill · corrodedR2 DOOR SILL HAS CORROSION IN MULTIPLE LOCATIONS & CORROSION MIGRATING GIRT BAR PLATES. R & R R2 DOOR SILL IAW SRM 51-72-11.SDR YENA20150904407Pump · failedRETURNED TO DEPARTURE HYD Y RESERVOIR OVERHEAT: REFERENCED QRH, OVERHEAT MESSAGE EXTINGUISHED ON BASE TO FINAL. LANDED WITHOUT FURTHER INCIDENT. BRAKES TEMP, HIGHEST 340. NO HARD LANDING. FOUND YELLOW PUMP COOLING FAN DAMAGED. R & R YELLOW SYSTEM CHECK VALVSDR AALA201509089004Bottle · defectiveCIDS CAUTION LIGHT ILLUMINATED, DUE TO LT OVERWING SLIDE BOTTLE PRESS INDICATION INOPERATIVE. REPLACED THE LT OVERWING SLIDE BOTTLE IAW AM 25-62-46.SDR AALA201509049001Battery · dischargedFORWARD FLIGHT ATTENDANT FLASHLIGHT, OTBD POSITION, NOT CHARGING. REPLACED BATTERY.SDR CALA2015090394267Smoke Detector · false activationSMOKE DET FAULT ECAM. CYCLED ACFT POWER, NO MSG DISPLAYED. ACCOMPLISHED CFDS SMOKE DETECTOR TEST, NO FAULTS. SYS CHECKED OK.
Back to Airbus A320-232