SDR YENA20150213018Socket · faultyDURING MAINTENANCE, FOUND ROW 15 EMERGENCY LIGHT INOPERATIVE. R & R ROW 15 EMERGENCY LIGHT SOCKET. OPS CHECK GOOD IAW AMM 33-51-18.SDR YENA20150212017Fan · failedRETURNED TO DEPARTURE DUE TO STRONG ODOR IN THE CABIN THAT SMELLED LIKE BURNING PLASTIC SHORTLY AFTER TAKEOFF. THE ODOR BEGAN TO DISSIPATE THEN RETURNED. FOUND "FAN" AMBER CAUTION ILLUMINATED ON "COND" PAGE. SELECTED CABIN FANS OFF, CAUTION EXTINGUISHED. RESDR YENA20150212016Epsu · failedDURING THE WEEKLY CHECK, EMERGENCY LIGHT TEST FAILED ON LT EPSU AT FIN 11WL. R & R EMERGENCY LIGHT EPSU AT FIN 11WL IAW AMM 33-51-38. LIGHT CHECKED OK.SDR CALA2015021293129Battery · dischargedEMERGENCY LIGHTS OPERATIONAL TEST FAILED. REPLACED LT EMER BATTERY LOCATED BY EMER EXIT IAW AMM 33-51-38, TESTED OK.SDR CALA2015021293123Door Frame · crackedL2 DOOR CUT OUT FRAME 68 LOWER STOP LOWER INBD HOLE HAS A CRACK INDICATION IN FRAME AT 6 O'CLOCK & 12 O'CLOCK POSITION. REPAIRED IAW SRM 53-41-12 PAR 5 E FIG 204.SDR CALA2015021293122Door Frame · crackedR2 DOOR CUT OUT FRAME 68 LOWER STOP LOWER INBD HOLE HAS A CRACK INDICATION IN FRAME AT 6 O'CLOCK POSITION. REPAIRED IAW SRM 53-41-12 PAR 5 E FIG 204.SDR CALA2015021293121Door Frame · damagedR2 DOOR CUT OUT FRAME 68 SECOND FROM LOWER STOP, OTBD UPPER HOLE HAS AN ELONGATION INDICATION OUT OF LIMITS IN FRAME. REPAIRED IAW SRM 53-41-12 PAR 5 E FIG 204.SDR USAA2015021200005Strap · unsecureSTRAP HANGING OUT BELOW L1 DOOR SLIDE BUSTLE. SECURED LOOSE STRAP AT L1 DOOR. OPERATIONS NORMAL.SDR USAA2015021200004Plunger · disengagedRIGHT OVERWING SLIDE DISARMED DURING PUSHBACK. FOUND FWD RT OVERWING EXIT DOOR ARMING PLUNGER NOT ENGAGED. RESET ARMING PLUNGER. INDICATION NORMAL ON ECAM.SDR USAA2015021000006Cover · brokenEMERGENCY ROW LIGHT COVER BROKEN. INSTALLED COVER.SDR USAA2015021000003Bottle · low pressureL4 DOOR ASSIST PRESS LOW & REQUIRES SERVICE. SERVICED L4 ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR CALA2015021293138Battery · dischargedFAILED EMER LIGHT BATTERY CAP TEST. GRIPES BATTERY CAP AFT LT IAW A CHECK JC 4-2020 STEP 33. REPLACED EPSU BATTERY 13W LT IAW MM 33-51-38-000-002-A & 33-51-38-400-002-A. INSTALLED PN AD-3214-31. CAP TESTED GOOD.SDR CALA2015021293137Battery · dischargedCABIN EMER LIGHT CHECK FAILED. GRIPES EPSU FWD LT IAW A CHECK JC 4-2020 STEP 26. REPLACED ESPU BATTERY 10WL IAW MM 33-51-38-000-002-A & 33-51-38-400-002-A. INSTALLED PN AD -3214-30.SDR CALA2015021093074Stringer · corrodedAFT CARGO COMPARTMENT STRINGER 43L CORRODED AT FRAME 56 - 59, TOP SURFACE & UNDERSIDE AROUND FLANGE. ACCOMPLISHED STRINGER REPAIR ON NR 9710677 IAW SRM 53-00-13 FIG 201 PG 211 DETAIL H. STRINGER REPLACED FROM FRAME 56 - 59.SDR USAA2015020500014Generator · failedWHILE ENROUTE CREW REQUESTED EMER HANDLING FROM ATC WITH THE LOSS OF NR 2 GEN. THE ACFT HAD ONLY 1 GEN SOURCE DUE TO THE NR 1 IDG SYS ON MEL. THE NR 1 IDG WAS REPLACED IAW AMM 24-21-51-401.SDR USAA2015020500008Idg · faultyWHILE ENROUTE CREW REQUESTED EMER HANDLING FROM ATC WITH THE LOSS OF NR 2 GEN. THE ACFT HAD ONLY 1 GEN SOURCE DUE TO THE NR 1 IDG SYS ON MEL. REPLACED NR 2 IDG IAW AMM 24-21-51-401.SDR USAA2015020500006Slider · obstructedFLIGHT ATTENDANT CANNOT DISARM SLIDE AT DOOR R1. REMOVED DEBRIS FROM R1 DOOR ARM SLIDER. OPERATIONS NORMAL.SDR USAA2015020500003Lens · detachedROW 11 RED LIGHT COVER ON THE SEAT BOTTOM BECAME DETACHED. REINSTALLED LENS.SDR CALA2015020693068Slide · defectiveEMERGENCY LIGHTS OPERATIONAL TEST DOES NOT PASS DURING 2 SERVICE CHECK. MESSAGE ATA 33-51-38 EXT LOADS FWD LT. TRIED NEW EPSU, NO HELP IAW TSM31-51-00-810-808A. REPLACED DOOR 1R SLIDE ASSEMBLY IAW AMM-25-62-44-400-006-A. PERFORMED EMER LIGHT TEST, SYS OPERSDR YENA20150203014Power Supply · failedDURING MAINTENANCE, EMERGENCY LIGHT SYSTEM TEST FAILED AS INDICATED AT AFT LIGHT EPSU. R & R AFT LIGHT EPSU BATTERY IAW AMM 33-51-38. SYS TEST AND OPS CHECK GOOD.SDR GTIA2015020201494Oxygen Mask · brokenF/O OXYGEN MASK BROKEN. R & R THE OXYGEN MASK IAW AMM 35-12-41, PB 401. OPS CHECKED GOOD.SDR CALA2015020393064Eec · malfunctionedCREW REPORT ENG 2 SENSOR FAULT & ENG 2 STALL MSG ON ECAM. HELD AT FL 160 & PERFORMED QRH PROCEDURES, NO STALL OBSERVED. CREW ELECTED TO RETURN. R & R NR 2 EEC IAW AMM 73-22-34-400-010-A13. COMPLIED WITH STEPS 3 THRU 5D.SDR USAA2015020200009Line · missingTWO OVERWING LIFE LINES MISSING. REPLACED TWO OVERWING LIFE LINES AS REQUIRED.SDR CALA2015020293050Skin · saturatedRIGHT ELEVATOR UPPER SKIN HAD 2 WATER FINDINGS FROM THERMOGRAPHY INSPECTION. 102.5 INCHES FROM INBD END & 4 INCHES FROM TE. 74 INCHES FROM INBD END & 4.5 INCHES FROM TE. BOTH AREAS REPAIRED IAW SRM 55-21-11 REPAIR PGS 234 - 236 FIG 205. REPAIR AREAS WERE BSDR USAA2015020200022Shear Pin · corrodedNUMBER 1 ENG AFT MOUNT INBD UPPER INNER SHEAR PIN HAS SLIGHT PITTING ALONG FULL LENGTH OF PIN APPROX 60 DEGREES OF RADIUS. REPLACED NR 1 AFT MOUNT INBD UPPER INNER SHEAR PIN IAW AMM 71-22-11-200-804-A.SDR CALA2015020293061Skin · damagedRIGHT WING TANK ACCESS PLATE 640PB HAS DAMAGED FASTENER HOLE ON LANDING. HOLE WAS REPAIRED IAW HAECO REO-L187 08 & CONSIDERED CAT B REPAIR IAW -B RDAS 80022401-003-2015. HOLE WAS OVERSIZED & BUSHING WAS INSTALLED. IAW CRA THRESHOLD SUPPLEMENTAL INSPECTIONS TSDR YENA20150130012Power Supply · faultedDURING MAINTENANCE, EPSU EMERGENCY EXIT AT LT POSITION FAULTED. R & R EPSU AT LT EMERGENCY EXIT, IAW AMM 33-51-38. OPS CHECK AND TEST OK.SDR USAA2015020200007Connector · defectiveSEAT 22C LED FLOOR PROXIMITY LIGHT INOPERATIVE. REPINNED EMER LIGHT CONNECTOR AT SEAT 22C. OPERATIONS CHECKED GOOD IAW AMM 33-50-00.SDR CALA2015020293054Skin · damagedRIGHT FUEL TANK ACCESS LANDING, TWO EACH HOLES HAS ELONGATION 640HB. R & R BUSHING HOLE 565 & INSTALLED BUS HINGE HOLE 562 IAW A320. SRM 57-21-11 PG 210-216 PAR B.SDR YENA20150129013Switch · malfunctionedEMERGENCY EXIT LIGHTING COMES ON/OFF INTERMITTENTLY INFLIGHT. SIGNS & FLOOR LIGHTING AS WELL. R & R EMERGENCY LIGHTS SELECTOR SWITCH 4WL ESPM 20-45-21. OPS CK GOOD.SDR USAA2015013000006Escape Rope · missingFLIGHT ATTENDANT REPORTS LIFE LINE OVERWING EXIT A/C LT MISSING, NOT WOUND CORRECTLY. REPLACED LT OVERWING LIFE LINE.SDR USAA2015013000004Switch · faultyEMERGENCY EXIT LIGHTS TURN ON WHEN SWITCH IS IN THE OFF POSITION. REPLACED EMER LIGHT SWITCH IAW SWPM CH 20. SYS OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-001A.SDR YENA20150128011Power Supply · failedDURING MAINTENANCE CHECK, FOUND EMERGENCY AISLE LIGHTS AT SEATS 15C ,19C, 23C INOPERATIVE. R & R EPSU AND BATTERY PACK. FIN 11 WL WORKED IAW 33-51-38, OPS CHK GOOD.SDR CALA2015012893034Strut · defectiveLANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. RETURNED TO FIELD. FAULTS WITH PROXIMITY SENSORS 21GA & 23GA. STRUT IS SHOWING A 250 PSI DIFFERENCE BETWEEN UPPER & LOWER CHAMBERS, 25 PSI IS GENERAL DIFFERENCE LIMIT. ADJUSTED PROXIMITY SENSOR. PERFORMED FULLSDR GTIA2015012601488Oxygen Mask · inoperativeOBS JUMPSEAT, OXYGEN MASK INOPERATIVE. R & R THE OXYGEN MASK STOWAGE BOX IAW AMM 35-12-41, PB 401. OPS AND LEAK CHECKED GOOD.SDR CALA2015012793033Door Sill · corrodedR2 DOOR SILL BEAM HAS CORROSION ON PREVIOUS REPAIR & FRAME 68, JUST FWD OF THE AFT GIRT BAR FITTING PLATE. R & R DOOR SILL IAW SRM 51-42-11.SDR CALA2015012793030Battery · dischargedEMERGENCY LIGHTS, OPERATIONAL TEST FAILED, BATTERY FWD LT DISPLAYED. REPLACED NR 1 BATTERY FWD LT. LIGHTS CHECKED GOOD IAW AMM 33-51-38-400-02.SDR CALA2015012793026Plate · corrodedNUMBER 2 RT AFT DOOR SILL PLATE HEAVY CORROSION. NR 2 RT AFT DOOR SILL PLATE REPLACED IAW SRM 51-72-11.SDR CALA2015012793024Engine · vibrationAT CLIMB POWER ENG 2 N1 VIB 2.7 WITH ENG 1 AT 0.4. ALSO ENG 2 EGT 570 DEGREES & ENG 1 AT 519 DEGREES. ACCOMPLISHED ON SHOT TRIM BALANCE IAW MT71-010, MM 72-31-11 & MM 71-00-00. TESTED NR 8. ALL INDICATIONS NORMAL, MAX N1 VIBE WAS 0.4 AT 85%.SDR USAA2015012600013Lens · missingEMERGENCY EXIT LIGHT ROW 9D RED LENS MISSING. INSTALLED RED LENS SEAT 9D EXIT LIGHT.SDR CALA2015012393010Fitting · corrodedR2 DOOR AFT SHAPE SILL CORNER FITTING FOUND CORROSION DURING REMOVAL. R & R CORNER FITTING IAW SRM 51-44-11 & 51-75-12.SDR CALA2015012393009Door Sill · corrodedR2 DOOR SHAPE SILL HAS CORROSION AROUND FASTENERS. REPLACED DOOR SHAPE SILL IAW SRM 51-73-11.SDR CALA2015012393007Battery · dischargedEMERGENCY LIGHT BATTERY CAPACITY TEST FAILED, EPSU BATTERY CAPACITY AFT LT. REPLACED AFT LT BATTERY 13WL. PN AD-3214-31. BATTERY CAPACITY TESTED OK.SDR YENA20150122010Power Supply · failedON MAINTENANCE CHECK, FOUND RT INTERIOR AND EXTERIOR EMERGENCY LIGHTS SHOWING FAULTS ON THE POWER SUPPLY. R & R EPSU IAW 33-51-38. OPS CHECK GOOD.SDR CALA2015012393017Epsu · faultedEMERGENCY LIGHT FAILED TEST, FAULTS CTR LT EPSU. REPLACED CTR LT EPSU & BATTERY IAW AMM 33-51-38, TESTED OK.SDR CALA2015012393020Charger · inoperativeD1L EMER EXIT LIGHT CHARGER INOPERATIVE, CICS. CHANGED CHARGER & BATTERY IAW MM33-51-38-401. OPERATIONS CHECKED GOOD.SDR USAA2015012200004Lens · detachedROW 1 LT EXIT LIGHT LENS CAME OFF. REINSTALLED EMER EXIT LIGHT LENS AT ROW 1 LT.SDR USAA2015012200003Battery · dischargedNUMEROUS CABIN EMER LIGHTS INOPERATIVE. REPLACED AFT EMER LIGHT BATTERY UNIT IAW AMM 33-51-38-400-002-A.SDR CALA2015012393019Stringer · corrodedSTRINGER 31R AT FRAME 65 BELOW OUTFLOW VLV IS CORRODED. REPLACED FACTORY SECTION OF STRINGER IAW SRM 51-72-11.SDR GTIA2015012001487Bottle · low pressureL1 DOOR ASSIST ACCUMULATOR LOW PSI. SERVICED L1 DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00-614-001-A. OK FOR SERVICE.
Back to Airbus A320-232