SDR USAA2013080700005Lens · detachedFLOOR LEVEL EXIT LIGHT FACEPLATE AT 9-D DETACHED. REPLACED EMERGENCY LIGHT LENS AT ROW 9, RT AND LT.SDR USAA2013080700004Battery · inoperativeAFT FLASHLIGHT INOPERATIVE. REPLACED BATTERY IN FLASHLIGHT.SDR CALA2013080790230Light · burned outEMERGENCY LIGHT BURNED OUT AT ROW 10 REPLACED EMERGENCY LIGHT, CHECKED OK.SDR CALA2013080690179Jack · missingF/O BOOM MICROPHONE RECEPTACLE MISSING. SECURED F/O MICROPHONE JACK ASSY, CHECKED OK.SDR YENA20130805169Valve · failedAIR RETURN DUE TO VENT AVNCS SYS FAULT AFTER TAKEOFF. R & R AVIONICS SKIN AIR INLET VALVE IAW AMM 21-26-52. OPS CHECK GOOD.SDR YENA20130805168Actuator · rupturedCREW DECLARED AN EMERGENCY DUE TO HYD GREEN NR 1 ENGINE PUMP LOW PRESSURE AND HYD G SYS LOW LEVEL. ACCOMPLISHED AMM TASK 29-00-00-280-006, FOUND FLEX LINE ON LT MLG DOOR EXT/RETRACT ACTUATOR RUPTURED. R & R BOTH FLEX LINES AND JOINT SWIVEL ASSY IAW AMM 32-31SDR CALA2013080790229Control Panel · looseEMERGENCY LIGHT PANEL AT L1 DOOR LOOSE, STICKING OUT INTO DOOR WAY. SECURED LOOSE EMERGENCY LIGHT PANEL.SDR CALA2013080590163Sensor · looseAFT CABIN TEMP UNCONTROLABLE WITH FULL HOT- HOT AIR SELECTOR AT 2.60 DRG. PAC 1 OUTLET WAS ACP CFDS CAB TEMP TEST AND OPS CHECK NORMAL, RAN PACK 1 AND TEMP FOLLOWED AND RESPONDED TO COCKPIT INPUT, REMOVED AND INSPECTED AFT CABIN TEMP SENSOR AND FOUND CLEAN. FOSDR CALA2013080590162O-Ring · leakingCREW REPORTED LOST YELLOW SYSTEM QTY AND PRESSURE IN FLIGHT. UPON ARRIVAL FOUND HYD FLUID COMING FROM PTU MANIFOLD CHECK VALVE 3094GM. O-RING FOUND DAMAGED. REPLACED O-RING, SERVICED YELLOW HYD. RAN BOTH ELECT YELLOW AND RAN NR 2 ENG YELLOW PUMP. NO LEAKS ANSDR CALA2013080590156Skin · dentedDENT FOUND FWD OF L1 DOOR AT FRAME 12 APPROX .046 DEEP. REMOVED FASTENERS CUT OUT FUSELAGE SKIN AT FRAME 12 IAW SRM 53-00-11, FIG 213, FABRICATED REPAIR DOUBLER & INSTALLED IAW SRM 53-00-11, FIG 213.SDR CALA2013080590147Bracket · crackedDURING MX, FOUND NR 1 ENGINE RT GUSSET BRACKET FOR THRUST REVERSER OPEN ACTUATOR LINE CRACKED. R & R GUSSET BRACKET IN REF WITH SRM 51-42-11.SDR CALA2013080790225Battery · inoperativeRIGHT EMERGENCY EPSU BATTERY FAULT LIGHT. REPLACED EPSU BATTERY IAW AMM.SDR GTIA20130803409Bottle · low pressureR2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED IAW AMM.SDR CALA2013080590128Unknown · vibrationAT DEPARTURE, FLT CREW REPORTED VIBRATION IN AFT GALLEY.SDR CALA2013080590122Radome · burnedRADOME HAS A BURN 11 O'CLOCK .25 DIA. DAMAGE AREA WITHIN LIMITS. REPLACED RADOME.SDR GTIA20130802922Engine · stalledECAM ENG 2 STALL ON DESCENT. FELT HEAVY ENGINE STALL. PERFORMING COM 3.70.39 RESULTING IN ENGINE 2 SHUTDOWN. PERFORMED COM ENG 2 SHUTDOWN AND PROVISION 3.70.36.TIME OF ENG STALL 1123Z, OIL PRESSURE OBSERVED NORMAL. ALTITUDE APPROX FL250 WEATHER WAS CLEAR,SDR CALA2013080790227Sliding Window · out of adjustCAP COCKPIT ESCAPE WINDOW DOES NOT OPEN PROPERLY, STICKS. DIFFICULT TO OPERATE. CHECKED HANDLE WITH DYNAMOMETER, WENT WELL PAST 50FT .LBS, WINDOW DID NOT RELEASE. ADJUSTED SLIDING WINDOW.SDR CALA2013080590150Window · stickingCAPTAIN`S COCKPIT ESCAPE WINDOW DOES NOT OPEN PROPERLY, STICKS, DIFFICULT TO OPERATE. CHECKED HANDLE WITH DYNAMOMETER, WENT WELL PAST 50 FT LBS, WINDOW DID NOT RELEASE. ADJUSTED WINDOW IAW MM.SDR CALA2013080590129Actuator · leakingRAMP REPORTED FUEL LEAKING FROM NR 2 ENGINE ON TAXI IN. MOTORING ENGINE RUNNING, LEAKING OF FUEL FROM DRAIN MASK CORE DRAIN. REPLACED NR 2 ENGINE LPC BLEED SLAVE ACTUATOR, OPS CHECKED GOOD. NO FAULTS, NO LEAKS.SDR CALA2013080590126Liner · damagedSMALL PIECES OF ATTRITION LINER MISSING AT 4, 5, 10, 11 O'CLOCK POSITIONS, LOOKING FROM REAR OF ENGINE. MISSING LINER LESS THAN 20 PERCENT OF LINER SEGMENTS.SDR USAA2013080500007Lens · missingR2 DOOR EMERGENCY LIGHT LENS MISSING. REPLACED LENS.SDR CALA2013080690178Servo Valve · faultyR B ELEV SERVO VALVE ISSUE. DUE TO CONTINUED HIT OF R B ELEV SERVO VALVE 34CE4 ACP TSM 27-30-00-810-828-A, SERVO VALVE 644-9014. R & R ELEVATOR SERVO CONTROL ACTUATOR SERVO VALVE. ON VALVE 34CE4. OPS CHECKED GOOD. NO FAULTS NOTED.SDR CALA2013080590148Unknown · unknownLOUD HUMMING NOISE COMING FROM R2 DOOR IN CLIMB.SDR CALA2013080590123Switch · brokenPUSH TO TALK ON F/O SIDESTICK IS BROKEN OFF. REPLACED SIDE STICK IAW MM. OPS CHECKED IAW MM, OPS CHECKED GOOD.SDR CALA2013080290118Skin · damagedLEFT WING SKIN FUEL LANDING FOR ACCESS PANEL 540RB HAS 1 DAMAGED SCREW HOLE. HOLE WAS REPAIRED IAW ECRA 5720-0243 5 AND REO-L01409, REV 1R.SDR CALA2013080290112Engine · leakingAFTER ENG 1 START, LIQUID LEAKING OUT OF ENG 1. SMELLED LIKE FUEL.SDR CALA2013080290108Unknown · vibrationMILD VIBRATION IN FLOOR BY EXIT ROWS ROW 20, FL370, .78M SMOOTH AIR.SDR YENA20130731166Proximity Sensor · failedCREW DECLARED AN EMERGENCY DUE TO INTERMITTENT NOSE GEAR UNSAFE INDICATION FROM ONE OF THE LGCIU'S. R & R PROX SENSOR 18GA IAW AMM 32-13-73. ADJUSTED 18GA SENSOR AND TARGET IAW AMM 32-31-73 PERFORMED SATISFACTORY GEAR SWING IAW 32-31-00.SDR CALA2013073190101Skin · dentedDENT ON FUSELAGE, LT NOSE NEAR NOSE UNDER LT SIDE STBY STATIC AREA. DENT IS AT FRAME 5, STR 31LT 1FT AFT OF THE FWD LWR EE DR. MEAS 2 AND 1-2" BY 1 AND 3-4TH .015" DEEP. ACCOMPLISHED VISUAL INSPECTION IAW SRM 53-11-11, DIG 103 PGS 137-138 NO CRACKS NOTED. RESDR CALA2013080590121Duct · splitVIBRATION FELT IN FLOORBOARD AT ROW 22, RT BY THE SIDEWALL WHEN PACKS OR RECIRCULATION FANS ARE OPERATING. REMOVED FLOORBOARD AND FOUND BAD DUCT, SEAM SPLIT. REPLACED DUCT IAW 21-20-00-410-001A.SDR CALA2013073090077Computer · faultyELAC 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. - F-CTL. REMOVED AND REPLACED NR 1 ELAC COMPUTER. PERFORMED OPS TEST PER AMM. ALL CHECKED GOOD. ACFT REMAINS AUTOLAND LIMIT CAT 3 SINGLE AS PER PLA SFR 4730 DUE TO NR 3 IRS ON PLACARD.SDR CALA2013073090075Transceiver · faultyRADAR ERRATIC & UNRELIABLE, SHOWS DIFFERENT ECHOES WITH EACH SWEEP, FALSE ECHOES. REPLACED WEATHER TRANSCEIVER IAW AMM.SDR YENA20130729164Servo Control · failedCREW REPORTED NOSE WHEEL STEERING FAULT AFTER LANDING AND UNABLE TO RESET. ACCOMPLISHED TROUBLESHOOTING IAW TSM 32-51-00-810. R & R NOSE WHEEL STEERING SERVO CONTROL IAW AMM 32-51-51.SDR CALA2013080290110Engine · overheatedECAM ENG 2 EGT OVER LIMIT DURING APPROACH ABOUT 1500 FT.SDR CALA2013080290109Engine · stalledAHM INDICATES ENG 2 STALL ECAM IN CRUISE. CREW REPORTED AUDIBLE STALL AND AND YAW, REDUCED THROTTLE IAW FM. ENGINE STALLED AGAIN ON THROTTLE ADVANCEMENT.SDR CALA2013073090086Battery Pack · malfunctionedEMERGENCY LIGHTING TEST HAS FAILURE MESSAGE FOR BATTERY. REMOVED AND REINSTALLED SAME BATTERY PACK. FAULT CLEARED AND TESTED OK.SDR CALA2013073090078Unknown · vibrationLOUD METALLIC VIBRATION SOUND HEARD AT L2 DOOR. CAN BE FELT WHEN HAND IS PLACED ON DOOR. DUE TO HISTORY OF NOISE AND VIBRATION AND CREW REPORT OF NOISE INTERFERRING WITH CREW COMMUNICATION MUST CHECK DOOR COVER PLATE, SEALS , FRAME AREA, AND PRESSURIZE TO ISSDR YENA20130728163Wire Harness · damagedDURING MX CHECK, FOUND FLOOR EMERGENCY LIGHT AT SEAT 15 C INOPERATIVE. R & R EMERGENCY LIGHT HARNESS ASSY AT SEAT 15C IAW AMM 33-51-21. OPS CHECK OK.SDR CALA2013072990021Girt Bar · dirtyARMING LEVER BINDING WHEN TRYING TO CLOSE 1L. CLEANED AND REMOVED DEBRIS FROM GIRT BAR AREA, DOOR OPENS AND CLOSED NORMALLY. ACFT OK FOR SERVICE.SDR CALA2013072990018Solenoid · faultedNR 1 ENG EGT OVERTEMP, RTFL AT 685 DEGREES DURING TAKEOFF. ENG EGT MAX READING 644 DEGREES RECORDED, INSPECTED AND LUBED ALL NORMAL, PERFORMED BLEED SOLENOID CHECK IAW JIC 4-2275, FOUND 10 STAGE SOLENOID FAULT. REPLACED SOLENOID. PERFORMED HIGH POWER ASSURASDR CALA2013072990017Sensor · faultyENG 1 SENSOR FAULT.SDR CALA2013072990015Microphone · inoperativeCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. AMU IAW MM 23-51-34 AND CF DS TEST OK AND BOTH MASKS FUNCTION NORMAL.SDR USAA2013072900006Lens · missingEXIT LENS AT ROW 10F MISSING. REPLACED LENS AT ROW 10F.SDR USAA2013072900004Power Supply · inoperativeEMERGENCY CEILING LIGHTS AT ROW 4 AND 15 INOPERATIVE. R & R EPSU, OPS CHECK GOOD IAW AMM 31-51-38-PB0401-001A.SDR GTIA20130727404Bottle · low pressureR1 DOOR LOW AIR PRESSURE. SERVICED R1 DOOR ASSIST ACCUM 14W IAW ACFT MM TO CORRECT PRESSURE.SDR GTIA20130727403Knob · damagedAFT GALLEY R2 DOOR MEGAPHONE MISSING VOLUME KNOB AND CAP SCREWS WORN. R & R AFT GALLEY R2 DOOR MEGAPHONE.SDR GTIA20130727402Knob · damagedFWD GALLEY L1 DOOR MEGAPHONE MISSING VOLUME KNOB & CAP SCREWS WORN. R & R FWD GALLEY L1 DOOR MEGAPHONE.SDR YENA20130727162Engine · failedACFT ON 10 MILE FINAL, OBSERVED ECAM ENG 1 COMPRESSOR VANE FAULT AND EGT WAS AT 725 DEGREES , DELARED AN EMERGENCY. R & R ENGINE NR 1 IAW AMM 71-00-20-000-04A. OPS CHECK AND LEAKS OK.SDR YENA20130727160Battery Pack · no testDURING MX BATTERY EPSU CAPACITY TEST. BATTERY FAILED TEST. R & R EPSU 12WL IAW AMM 33-51-38. OPS CHECKED GOOD.SDR CALA2013072990041Indicator · leakingDRIPLESS STICK L5 LEAKS WHEN EXTENDED. TO REPLACE ROD 482-0114 PULL ALL THE WAY OUT, SLIDE IN NEW ROD IAW AMM 28-43-22. VERIFIED NO LEAKS WHEN STOWED. DEFERRED IAW MEL, INSTALLED DEFERRED STICKER ADJ TO LOWER ECAM.
Back to Airbus A320-232